Detex EAX-500 User manual

101321 Page 1
9V Battery
P/N: PP-5567 (or equivalent)
Battery retainer
P/N: 102606
Circuit board kit
P/N: 102656-1 (Standard)
P/N: 102656-2 (Weatherized)
Cam assembly kit
P/N: 102655
Magnet locator
P/N: 102607
Switch guard
P/N: 102613
03 Rim cylinder plate
P/N: 102638
(not used on wall
mounted devices)
#8-32 Truss HD screw
P/N: 102627-15
Cover lock,
nut, and 2 keys
P/N: PP-5572
Cylinder nut
P/N: 100783
Parts breakdown depiction
(Mortise cylinder required)
Locate this component
for Step 6
INSTALLATION INSTRUCTIONS FOR THE EAX-500 EXIT ALARM
(EAX-500 / 500W / 500SK)
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045
(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711
E-MAIL: detex@detex.com INTERNET: www.detex.com
101321 September 26, 2011
U.S. PATENT NUMBERS:
20050257389
20050231363
20050223764
Magnet Kit
P/N: 102665
Hardware Kit
P/N: 102633
(includes Keystop
P/N: 102688)
Backplate
P/N: 102603
Mortise Cylinder with
standard Yale cam
required
.715"
.313"
Mag switch
(surface mount)
P/N: MS-1039S
(EAX-500SK only)
The Detex EAX-500 is designed for applications that require an alarmed exit device on secured doors. The alarm, with
approximately 100dB, will sound when someone attempts an unauthorized exit. The EAX-500, with it's smaller size
makes it the choice for quick and easy installations on emergency exit and restricted doors.
OPTIONAL:
Cylinder nut socket
P/N: 103779
Drawing # 102600
Device will vary based on
configuration and order options.

STEPS 1-5: PREP DEVICE
Remove cam assembly
from cover
1Install mortise cylinder with cylinder nut provided
Cam orientation as shown
with key removed
2
Mortise cylinder
NOTE: For "Key Stop", See Step 9
Unfasten
(2) screws
Set OKC cam
as shown
3 4
AUTO
REARM
(OFF)
Set selector switch functions (See Table A)
Re-install
cam assembly
CORRECT
WRONG
Connect 9-volt battery
and install as shown
5
Table A: Selector Switch Functions
STATUS
INDICATOR
OFF* No indication that device is armed or disarmed.
ON
AUTO
REARM
OFF*
Alarm will automatically rearm 2 minutes after alarm has been activated and door closed.
Custom settings can be programmed by DETEX.
Non-Extended (Timed) Bypass (see OPERATIONS page)
ON
Key required to reset the alarm after it has been activated.
Extended Bypass (see OPERATIONS page)
( *Default settings; **Will shorten battery life)
ARMED - red LED blinks approximately every 3 seconds.**
DISARMED - green LED blinks approximately every 3 seconds.**
(Default settings shown)
Collar required if distance
is greater than 5/16".
Optional collar can be ordered
from Detex (p/n: ECL-1595)
If 7-pin cylinder is used -
OBSERVE
STATUS
INDICATOR
(OFF)
101321 Page 2

Mark/drill backplate and magnet holes
on door and frame/mullion
DOOR
ASSEMBLE
Install magnet with (2)
#4-40 or #4 screws
Install backplate with (2)
#1/4-20 or #14 screws
FRAME/MULLION
DOOR
LHR installation shown
for reference only
OKC
Backplate
Drill #7 for #1/4-20
machine screws
Drill 7/32" or 3/16" for
#14 sheetmetal screws
Magnet
Drill #43 for #4-40
machine screws
Drill #44 for
#4 sheetmetal
screws
Backplate
Drill #7 for #1/4-20
machine screws
Drill 7/32" or 3/16" for #14 sheetmetal screws
3/4"
1-3/8"
Dia
DOOR
TAILPIECE PROVIDED
Where applicable,
mark TOP hole center &
drill 1/4" dia. pilot hole
through door
See OKC INSTALLATION
Drill 1-1/4" hole
through outside
door face
Drill 1-3/8" hole
through inside
door face
Cylinder Side:
Device Side:
1-1/4"
Dia
IMPORTANT!
Outside Key Control (OKC) Installation
(if required)
(all models except SK)
Rim cylinder - Detex P/N: ECL-445K-X
STEP 6: For all models except SK
DOOR PREP & BACKPLATE / MAGNET MOUNTING
Install magnet, backplate and cover
Skip to Step 8 to continue non SK installation
NOTE: Remove locator and backplate prior to drilling mounting holes
101321 Page 3

Install backplate with (2)
#1/4-20 or #14 screws
STEP 6: For SK models
BACKPLATE MOUNTING
1-1/2
Flex walls outward to remove guard
& board
1"
Drill 7/8 dia
(1) place
Recommended hole size
Common
Terminal
P/N: PP-5107
Closed Mag
Switch 1
Switch 2
Mag
Diagram shown typical for two door magnetic switches:
MS-1039S & MS-1059S wire in series.
MS-2049 (Red wire not used)
Weatherized not available for SK installations
Closed contact when door is closed
NOTES:
1. If wire runs longer than
10 feet, must use twisted pair
2. 1/16" slotted jeweler
screwdriver required.
3. If internal contact is used
DO NOT cut jumper (JP1)
Disconnect power &
cut (JP1) jumper
(see note 3 below)
STEP 7: Multi-door & SK function wiring connection (if required)
(Recommended installation)
7a 7b 7c
7d Screw wires to (P1) terminal block
(18ga Max wire dia) (not available on weatherized)
Reassembly:
Fitting or nut NOT included
Common
Closed
101321 Page 4

CORRECT
"ON" position
(Key can be removed)
"OFF" position
(Key cannot be removed)
.050" Hex Wrench
(NOT PROVIDED)
Rotate key to this
position before reinstalling
cam assembly
Mortise cam orientation
as shown
Key stop
installed
WRONG
Back View
Front View
KEY STOP POSITIONS
STEP 9: KEY STOP INSTALLATION (Key stop included in hardware kit)
Top surface of Key Stop should
NOT protrude beyond highest
point on plastic cam
Install key stop
P/N: 102688
Cam orientation
for Key Stop option
Key and cams
shown in "OFF"
position
Key and cams
shown in 90°
stop "ON"
position
STEP 8: INSTALL DEVICE
Install device onto backplate
Turn key CW
to lock cover
Hook at bottom, then tilt
cover over backplate
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
101321 Page 5

OPERATIONS
SPECIAL NOTES and DEFINITIONS:
1. The door needs to be closed to test the unit.
2. When operating the ON/OFF switch, there is a slight delay.
3. The key is inserted and removed only in the vertical position (home position).
4. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed
5. Outside Key Control (OKC)
The bottom left hand switch is only used when the outside key control function is used. This allows
entry from outside. It bypasses the alarm & rearms in 15 seconds after the door closes. The OKC
will not arm or completely disarm the alarm as the inside key does. When in Extended Bypass mode
(Auto Rearm switch OFF) the unit will not rearm until 15 seconds after the door closes. The door can
remain open if desired. When in the Timed Bypass mode (Auto Rearm switch ON) the unit will arm
after 15 seconds & go into alarm if the door remains open.
6. If re-handing is necessary, momentarily short across the Mag Rst (orTest) jumper contacts,
remove battery and follow the handing steps below.
MAGNET HANDING PROCEDURE:
Magnet handing is where the device determines if
the left, right or an external reed switch will be used to indicate if the door is opened or closed.
When the battery is initially installed, the device simultaneously flashes the LEDs and chirps the
siren a total of five times.
This indicates that the device is in the magnet handing process:
Step 1: Turn the key CW to the 'OFF' position and connect the battery.
Step 2: With the door open, install the device on the door.
Step 3: Turn the key CCW to the 'ON' position. The red LED blinks twice.
Step 4: Close the door or bring the external magnet into position on the desired side of the device.
The siren chirps and the LED flashes on the selected side of the device (red LED flashes
for the left side or external; green LED flashes for right side).
The device will now operate normally, and the selected reed switch side is stored in memory so
changing the battery does not require re-handing.
RE-HANDING:
If re-handing is necessary, remove the unit
from the door and momentarily short the Mag Rst (orTest)
jumper contacts, remove the battery and repeat the steps above.
OPERATIONS:
To arm the system, close the door and turn the key CCW to the 'ON' position.
The red LED will blink twice followed by the green LED flashing for the remainder of the arming
time (default 15 seconds). After the arming time, the green light will turn off and the siren chirps/
red LED flashes three times. The device is now armed and if the door is opened the alarm will
sound and the red LED turns on.
DISARMING:
To turn off the alarm or disarm the system, turn the key CW to the 2 o'clock position.
AUTO REARM:
With the Auto Rearm switch 'ON', alarm shuts off two minutes after closing the door.
EXTENDED/NON-EXTENDED (TIMED) BYPASS:
With the Auto Rearm switch in the 'OFF' position, the unit operates
in the extended bypass mode. This mode prevents the unit from arming while the door is open. Converslely, with the Auto Rearm
switch in the 'ON' position, the unit operates in the non-extended (timed) bypass mode. This mode allows the unit to arm regardless
of the doors position. If the door is not closed at the end of the arming delay, the unit will go into alarm.
"ON"
position
"OFF"
position
"ON"
position
Key orientation
without Key Stop
installed
Key orientation
with Key Stop
installed
"OFF"
position
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Mag Rst (orTest)
jumper contacts.
101321 Page 6

LV Opt jumper
behind cover
(under AUTO
REARM switch)
LOW BATTERY ALERT: Simultaneous siren chirps and red LED flashes occur at 45 second
intervals when the battery reaches approximately 7 volts. The LV Opt jumper must be in place for
this feature (default).
STATUS INDICATOR: With the Status Indicator switch 'ON', red LED flashes every three seconds
when armed; green LED flashes every three seconds when disarmed.
AUTO REARM: With the Auto Rearm switch 'ON', alarm shuts off two minutes after closing the door.
ACTIVATE / DEACTIVATE SILENT ARMING: NOTE: Device must be magnet handed.
1. Turn the key CW to disarm and remove the unit from the door if installed.
2. Remove the battery.
3. Turn the key CCW to the 'ON' position. Hold the OKC switch lever (see Step 3) closed and install
the battery. The unit chirps twice when silent arming is turned 'ON', and chirps once when silent
arming is turned 'OFF'.
4. Release the OKC lever and turn the key CW. Reinstall the unit on the door.
OPERATIONS (con't)
Probable Cause
Problem Action
Device is not powering up 1) Battery not properly installed.
2) Cylinder microswitch lever broken.
3) Cylinder installed incorrectly.
1) Remove battery and firmly reinstall.
2) Microswitch needs to be replaced.
Remove PCB and return to Detex repair.
3) Check cylinder installation. Make sure
key is turned counter-clockwise all the
way to ON.
Device not arming.
Auto Rearm -OFF
1) Magnet not aligned correctly.
2) Battery is dead.
1) Use magnet locator to install magnet.
See magnet handing.
2) Replace battery.
Technical Support 1-800-729-3839
Chirp every 45 seconds Install new battery.
Low Battery.
No status indicator Slide Status Indicator slide switch to the
ON position.
Status indicator is OFF.
Unit is not Auto Rearming Slide Auto Rearm slide switch to the ON
position.
Auto Rearm is OFF.
External magnet not working Slide MagRst to ON then OFF, listen for
three chirps. Disconnect battery, turn
JP1 to the OFF position, install battery.
2) Use MS-2049 black and white wires
to green connector.
1) Device is not set for external
magnet.
2) MS-2049 not wired correctly.
One side does not work. Rehanding needs to occur.
Unit is handed on the wrong side.
The alarm sounds after
the time delay
1) Close door and rearm door.
2) Use magnet locator to install magnet.
Shim as needed.
1) Door not closed.
2) magnet not aligned.
Chirps 5 times when battery
is plugged in.
See magnet handing procedure
1) Device needs to be handed.
TROUBLESHOOTING
101321 Page 7

Optional Accessories
Cylinder Nut Tool
P/N: 103779
Inswing Door Kit
P/N: 102644
101321 Page 8
This manual suits for next models
2
Table of contents
Other Detex Security System manuals