Detex VALUE SERIES V40 x EB User manual

FV40 / V40 x EB, EH, EHxR, EX
P/N: 100482
P/N: 100088
Mortise
Strike Shim
98 Strike *, P/N: 100855-1
P/N: 100480
P/N: 100234-1
Mortise Strike
Strike Shield
P/N: 101899
P/N: 100212
2" Narrow Stile
Plastic Template
P/N: 100481
101275 Page 1
Fillerplate SubAssembly (EX x CD)
Owner's Copy
P/N: 104356-1 (3-0)
P/N: 100783
Hex Nut
P/N: 101815-X (4-0)
P/N: 101810-X (3-0)
Pushpad Wrap
Fillerplate SubAssembly
RIM
99 Strike *, P/N: 100855-2
P/N: 101805-1
Centercase Cover
Mounting plate
Subassembly
P/N: 100696-1
Strike ShimNon-Roller Strike
Standard
Plastic Template
P/N: 104350-X
Plastic Template
Centercase/Pushpad SubAssembly
Use for ease of installation
Parts Check List
Fillerplate SubAssembly (EX x HD)
(Electrified Models)
Fillerplate Subassembly (EX x LD)
Fillerplate SubAssembly
P/N: 104358-X
P/N: 104357-1 (3-0)
P/N: 104355-1 (3-0)
P/N: 100783
P/N: PP-5567
Hex Nut
9V Battery
Hex Key
P/N: 100450
Endcap Bracket
U.S. PATENT NUMBERS:
6009732
6205825B1
6532777B2
INTERNATIONAL PATENT NUMBER:
PCT6009732
P/N: 101844
P/N: 101822
Endcap
P/N: 101821
INSTALLATION INSTRUCTIONS FOR DETEX VALUE SERIES® V40 RIM PANIC HARDWARE,
FV40 RIM FIRE EXIT HARDWARE AND "H" MODELS (HURRICANE)
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045
(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711
E-MAIL: detex@detex.com INTERNET: www.detex.com
101275 November 09, 2007
-GlassBeadKit
-SexNuts
-TamperKit
- Double Door Strike Kit
-KeyStopKit
- Narrow Stile Kit
See
Optional Accessories
For:
Mortise cylinder not included with device.
Standard Yale type cam required.
Note: Parts listed above will vary
according to product configuration.
*Narrow Stile "NS" option
Latchbolt Monitoring
Centercase Assembly
P/N: 104354
P/N: 104357-3 (4-0)
P/N: 104355-3 (4-0)
P/N: 104356-3 (4-0)
L9 = Less 9v Battery
SI = Status Indicator "ON"

frame engages at
Minimum door stile 2" (51mm)
RHR Door
Inside Face
C
L
Floor
Finished
40"
101275 Page 2
RHR Door
Reference
Stop Face
Horizontal
LHR Door
Inside Face
LHR Door
Face
Mullion
Door Must Not Bind
NOTE: 750mm MAXIMUM DOOR WIDTH OPENING FOR EUROPE FOR 36" DEVICE
(1000mm MAXIMUM DOOR WIDTH OPENING FOR EUROPE FOR 48" DEVICE)
THE SAFETY FEATURES OF THIS PRODUCT ARE ESSENTIAL TO ITS COMPLIANCE WITH EN 1125.
NO MODIFICATION OF ANY KIND, OTHER THAN THOSE DESCRIBED IN THESE INSTRUCTIONS ARE PERMITTED.
X
Door Must Swing Freely Door Must Not be Warped
Surface strike possible
Mortise strike recommended
least (3) screw
threads.
Door Must Not Sag
X
Door Skin
X
Blind Rivet Nut
X
Doors and frames with walls having a structural thickness (metal skin
plus reinforcement, or solid wood) to engage less than (3) full
screw threads, are considered unreinforced for hardware.
!!!CHECK BEFORE STARTING!!!
Unreinforced Doors: Use Sex Nuts and Bolts
Fasteners for unreinforced openings are not supplied by Detex.
Unreinforced Frames: Use Blind Rivet Nuts (see sketch)
Minimum door stile 4-1/2" (114 mm)
Wide Stile (Surface Strike)
Template drawings provide door and frame
door and frame preparation.
structural and dimensional specifications for
Narrow Stile
Reinforced door or Reinforcement

(2) Mortise Cylinder NOT Provided.
Note: (1) Fastener selection will vary per catalog configuration and kits ordered.
PPH
PPH
PFH
PFH
PFH
PPH
PFH
Screw Driver
Safety Glasses
Level
Sex Nut
#1/4-20
#10-32
Power Drill
Sheetmetal Screws
#1/4-20 x 1"
#6 x 1"
#10 x 1"
#1/4-20 x 1/4"
#10-24 x 5/8"
#6-32 x 3/8"
#14 x 1"
Center Punch
101275 Page 3
Tape Measure
Hammer
Hack Saw
Used on Strike, Mounting plate, and Endcap Mounting Holes
Used on Strike, Mounting plate, and Endcap Mounting Holes
Recommended on Fire Rated Wood and
9/32" Interior Door Face -----
----
13/64" Interior Door Face
5/16" Exterior Door Face
3/8" Exterior Door Face
-----
-----
-----
Pencil
Tools Required
----
----
----
Used on Strike Hook Mounting Holes
Unreinforced Hollow Metal Doors
Unreinforced Hollow Metal Doors
Recommended on Fire Rated Wood and
Used on Mounting plate and Endcap Mounting Holes
#7 or 13/64"
9/64"
-----
#25 or 9/64"
-----
-----
-----
-----
-----
#10-24 Tap
#1/4-20 Tap
-----
Metal Applications
Used on 99 Strike Center Mounting Hole
Used to Mount Centercase Cover and Endcap
Used to Fasten Centercase Unit onto Mounting plate
Used on 99 Strike Center Mounting Hole
Used on 98 Strike Shield Mounting Holes
PFH
#6-32 x 5/8"
Machine Screws
Fastener Table
Drill Bit Tap Wrench
#36 or 7/64 #6-32 Tap
Comments
Use Either Machine Screws, Sheetmetal Screws,
Used on 98 Strike Shield Mounting Holes
or Sex Nuts
Self-drilling Screws
No pilot hole necessary for
self-drilling screws

101275 Page 4
Strike holes (2)
For 1/4-20 machine screws
drill #7 holes
No pilot hole necessary
for #14 self-drilling screws
(see fastener table)
screws or #14
Fasten tightly with
1/4-20x1" machine
lockwashers and
self-drilling screws
Mark centerline
finished floor
40 inches above
for unit
two 1/4-20x1" machine
screws or #14
self-drilling screws
Fasten loosely with
6
label temporarily
if necessary.
(see outside
trim instructions)
Trim input hole
5
Slide99strikelocator
into mounting plate.
(ifusinga98strike,see
98 STRIKE INSTALLATION page)
1
holes
Mounting plate holes (2)
For 1/4-20 machine screws drill #7 holes.
For #14 self-drilling screws no pilot holes
necessary.
For sex nuts drill 3/8" holes.
(see fastener table)
and strike holes
Mark mounting plate
4
Punch marked
Mounting plate Hole
Strike holes
to mark trim hole
2
Mounting plate
hole
If necessary, remove
3
RECOMMENDED

101275 Page 5
When using Pushpad Wrap with text
(LHR handing shown)
verify handing before installing wrap.
Peel off backing
to expose tape.
IMPORTANT:
Install Pushpad Wrap.
by snapping in place.
Verify wrap is secured
3
Position cam as shown
Insert centercase into slots
of centercase mounting plate,
depress pushpad, rotate
toward door.
1
MUST BE INSTALLED!
to mounting plate
Fasten rim device
with 1/4-20 x 1/4" PPH
2
DOOR

2
1
101275 Page 6
(Call factory at (800) 729-3839 for assistance)
(Cut-Off procedure if required)
CHECKING FOR DEVICE CLEARANCE
onto extrusion
Slide endcap assembly
Secure
Protect wires
during cutting
Place battery in endcap.
Battery should not contact
circuit board.
Battery
4" 10"
Max. Cut-Off
Length (L) inches
beyond edge of cut fillerplate.
Reassemble electronics
Electronics may extend
36" Unit
after cutting.
48" Unit
longer than the standard
REMOVE battery clip
for CUT-OFF lengths
Procedures for Maximum Cut Down Lengths
REMOVE electronics
prior to cut down
34
Caution Required-Special Handling
1
with
tape
Align fillerplate
FLUSH to extrusion
prior to cutting
CAUTION:
Check for device & door
frame clearance. If no
cut-off needed, proceed to
MORTISE CYLINDER INSTALLATION
Cut fillerplate & extrusion to
desired length*
Install battery
(where required)
3
EX
Electrified
model
Cut fillerplate & extrusion to
desired length*
Protect wires
during cutting
6in
2in
12 in
8in
Secure
with
tape
2
36" Unit
Type 48" Unit
Length
Align fillerplate
prior to cutting
FLUSH to extrusion
5
cut-off length

101275 Page 7
cylinder with
Install mortise
hex nut provided
the fillerplate
subassembly
Slide/remove
NOTE:
installing slide in fillerplate.
(2) Turn key max CCW before
(3)Useacylindercollarwheninstalling
(4) Reinstall fillerplate subassembly
(1) All cylinder spacers must be used.
a 7-pin mortise cylinder.
and cylinder collar (not included)
length with spacers (provided)
Adjust for LONGER cylinder
Be careful when installing fillerplate assembly not to damage cable
MORTISE CYLINDER INSTALLATION
PRECAUTIONARY NOTE:
See View A
1
Longer cylinder
Cylinder collar optional
(see note 3)
(Detex p/n: ECL-1595)
2
CAUTION:
Tighten with hand
tools only. Do not
overtighten
View A
Install cable assembly
For Latch Bolt Monitoring (LBM) units only
Refer to switch options pages

101275 Page 8
for added security
Slide and mount endcap
to endcap bracket with two
1/4-20x1" PPH machine screws
or #14 self-drilling screws.
DO NOT OVERTIGHTEN
5
Slide fillerplate & endcap bracket into
extrusion & level pushpad assembly.
Note: Endcap Bracket must bottom-out
on extrusion. DO NOT REMOVE
NYLON SPACER ON BACK OF
BRACKET!
see HARDWIRE TRANSFER OPTIONS page
For 1/4-20 machine screws drill #7 holes.
For #14 self-drilling screws no pilot holes
necessary.
For sex nuts drill 3/8" holes.
Install (2) 6-32 FH Screws
IMPORTANT:
4
With pushpad assembly level,
secure the endcap bracket to door
by tightening the factory installed
self-drilling screw.
3
12

101275 Page 9
extend its life.
Care and Maintenance:
The Detex Value Series® devices are designed to provide many years of maintenance
free service under normal usage. Periodically inspect and lubricate the unit to with hand tools only.
Install cover with 6-32
machine screws. Tighten
4
Fasten rim device to mounting
plate and door with 1/4-20x1"
machine screws(drill #7 holes)
or #14 self-drilling screws
center screw.
strike engagement BEFORE
Align the 99 strike with
Firmly tighten screws
the latchbolt.
marking and drilling for
Check device function and
(use shim if necessary)
3
Note:
2
Mark and drill center hole.
9/64" for 10-24 machine
screws.
No pilot hole necessary
for #10 self-drilling screws.
(see fastener table)
Secure the 99 strike.
Deadlatch
99 strike
For Hurricane Models
(see Hurricane kit)
1

4
N.O. contactViolet
BrownPin 1 Common Pin 4
Contacts rated at 1.0A @ 30VDC or 0.5A @ 125VAC
Pin 5
Pin 6
Normally Closed
Yellow
Gray-Green
Pin 2
Pin 3
Normally Open N.O. contact
101275 Page 10
Violet
---- ----
Figure 3
P1 detail
1
25
36
P1 (see Fig. 3)
Figure 2
Battery Connector
(Standard)
(P1 wire usage)
Wiring Detail
Remote Signal
Table 5
(EHxR)
Bypass/Remote Signal
P2
J2
Remote Bypass
The device flashes one red LED and one beep about every 45 seconds
The Device gives no indication of battery being low.
On
Off (factory set)
J1
Protect wires
Switch selections must be made before applying power or installing battery (See Figure 1)
Table 2
See
See Table 1
Alarm sounds until turned off with key.
Unit sounds alarm as long as door is open.
Extended bypass is enabled.
Alarm turns off 2 minutes after door is closed
Auto Rearming Feature Setting
Status Description
Note: AC power must be applied
Table 3 (EH models only)
Disable Auto rearm
On (factory set)
Off
Disable Low Battery
Table 2
Status Description
The Device gives no indication of armed or disarmed status.
Status Indicator
On
Off (factory set)
SWITCH OPTIONS
Table 1
Disable
AUTOREARM
DisLo Bat
ON
ON
ON
INDICATOR
STATUS
Brown Common
Open
Closed
Yellow
Gray-Green
Install armored cable kit (if required)
V40 x EX Wiring Assembly
Fillerplate subassembly
Wire Color Connection
Endcap bracket
Endcap
(see Table 5)
Figure 1
See Table 3
(jumper w/L9)
TheDeviceflashesredorgreenLEDevery3seconds.
Red indicates armed status and green indicates disarmed.
12/24V AC/DC External Supply
(black wire)

L9SI SWITCH OPTIONS
L9 = Less 9v battery
SI = Status indicator
12/24V AC/DC External Supply
(black wire)
Alarm sounds until turned off with key.
The Device flashes red or green LED every 3 seconds.
Disable Auto Alarm
Switch selections must be made before applying power.
EH wiring detail
Figure 2
101275 Page 11
Disable Low Battery
Disable Auto rearm
Status Indicator
(No battery or leads on device)
Jumper
On
L9SI factory presets
On
J1
Protect wires
P1
Figure 1
STATUS
INDICATOR
Status
ON
AUTO REARM
ON
Disable
Dis Lo Bat
Dis Lo Bat

101275 Page 12
Order by finish
p/n: FCV
p/n: EWH8-X
Electric Hinge
Value Series Flex
Conduit/End Cap Kit
Note: For high traffic areas an electric through-wire hinge or power transfer is recommended.
Note: For high traffic areas an electric through-wire hinge or power transfer is recommended.
VALUESERIESFLEXCONDUITINSTALLATION
hand-tight
Fasten until
3
Drill 7/8" hole
through center guide
1
1/2" Hole through the
inside door face
Adjust for handing
4
2
(LHR shown)
1/2" Hole through the
inside door face
HARDWIRE TRANSFER OPTIONS
(EH and EHxR models)
Power Transfer
Wire chase through door
Electric Hinge Endcap Prep
p/n: PT-5
PowerTransferEndcapPrep
Wire chase through door
(Requirements: Minimum 6 Conductor Wires, Maximum 12 Conductor Wires)

ALARM OPERATIONS
Refer to SWITCH OPTIONS pages
Device features
For LBM models only:
push and hold deadlatch while
performing unit arming test.
Deadlatch detail
Deadlatch
Figure 2
Figure 1
Mortise
Cylinder Green LED
=On
=Off
PushPad
(LHR shown)
Siren
Red LED
101275 Page 13
SPECIAL NOTES and DEFINITIONS
1. The door needs to be closed to test the unit.
2. When operating the ON/OFF switch, there is a slight delay.
3. The key is inserted and removed only in the horizontal position (home position).
4. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed.
5. Arming delay mode and auto rearm timers vary by order.
6. The power needs to be removed to register changes in the slide switches.
a. Status Indicator (This will affect battery life)
b. Disable Auto Rearm
c. Dis Lo Bat INDicator (EH units only)
UNIT ARMING TEST:
1. Turn key counterclockwise (CCW) (key is removable after rotating back to horizontal position).
2. Red LED will flash twice, then green LED will illuminate for the 15 second delay time, then turn off.
The siren will sound three short beeps indicating the unit is armed.
3. Depress Pushpad (Siren will sound and red LED will illuminate)
4. Turn key clockwise (CW). Turns alarm off.
LOW BATTERY ALERT:
1. Siren will beep and red LED will blink at approximately 45 second intervals when battery is low.
DOGGING FEATURE: (non-fire rated units only)
1. Depress Pushpad.
2. While holding Pushpad depressed, turn key clockwise (CW). Pushpad should remain depressed.
(Key is removable after rotating back to horizontal position)
3. Unit is now disarmed.
STATUS INDICATOR
1. Slide the switch to ON and apply power.
2. If the unit is armed, the red LED will blink every 3 seconds.
3. If the unit is disarmed, the green LED will blink every 3 seconds.
Disable AUTO REARM
1. When the unit is in full alarm and the door closes, the alarm will shut off after 2 minutes.
Care and Maintenance:
The Detex Value Series® devices are designed to provide many years of maintenance free service
under normal usage. Periodically inspect and lubricate the unit to extend its life.

V40 EB/EH and LBM Troubleshooting Tips for Default Setting
No LED activity when key is
turned CCW to armed position
When the unit is armed, red LED
flashes twice, green LED is on
for 15 seconds, but the unit does
give three beeps after the green
LED goes off. The unit will not
sound when opened.
LED'sdonotflashtoindicate
armed or disarmed status
Give low battery alert.
When the unit is armed, red LED
flashes twice, green LED is on
for 15 seconds, but the unit does
give three beeps after the green
LED goes off. The unit will not
sound when opened.
Battery connector missing
Dead or weak battery.
Battery not secured to connector
correctly.
Slide switches not in default mode.
Outside trim not correctly installed.
Actuator is sticking to microswitch
Status indication switch is in off
position.
Dead or weak battery.
Dead latch not in proper position.
1/4-20 screws not installed.
L9 option ordered
Install new battery, LED's should flash and the
siren beep once.
Secure battery correctly.
Setswitchtodefalutandreconnectpower.
Check outside trim (if applicable). See trim
instructions.
Lubricate spring
Remove battery power from unit. Slide status
indicator switch to the ON position.
Reinstall battery.
Install new battery, LED's should flash and the siren
beep once.
Close door.
Door not fully closed. Press dead latch manually as
showninFig2onpg13.
If unit operates properly, check unit's backset and
adjust unit or add shims to strike as needed.
See page 5, bubble #2.
Battery connector not supplied with L9 option
EB/EH (Bar Monitoring)
PROBLEMS PROBABLE CAUSE ACTION
Technical Support 1-800-729-3839
101275 Page 14
LBM (Latchbolt Monitoring)
PROBLEMS PROBABLE CAUSE ACTION

101275 Page 15
#10 Sheetmetal screw
10-24 Machine screw
#25 or 9/64"
tap 10-24
#22 or 5/32"
pilot hole
Cutout per
(Caution: This installation is required on fire rated door openings with removable mullion.)
Door
Door frame
98 Strike
98 Strike locator
Mark and drill holes as necessary.
#7 for 1/4-20 machine screws,
For #14 self-drilling screws, no pilot
hole necessary
7/64" for 6-32 machine screws,
9/64" for #6 sheetemtal screws
(see fastener table)
99 strike
For mounting hole locations use Strike Locator (Template) provided.
DRILL CHART
Strike hook
Mullion post
STRIKE HOOK INSTALLATION
Door
Door
Shield (if necessary)
Shim (if necessary)
98 Strike
98 STRIKE INSTALLATION Align the strike with
the latchbolt.
Firmly tighten screws
(when required)

101275 Page 16
(4) Included
p/n: 101616-X
Catalog No: SN1 Brushed Chrome BHMA 626 Finish
Catalog No: SN1 Brushed Brass BHMA 606 Finish
Catalog No: SN1 Oil Rubbed Bronze BHMA 613 Finish
Catalog No: SN1 Stainless Steel BHMA 630 Finish
Dogging Lever Assembly
(shown for reference ONLY)
The #1/4-20 kit is available in (4) finishes:
Security Pin TORX
p/n: 101233
Key Stop Screw
p/n: 101867
Key Stop Kit
(Momentary Shunt)
Catalog No: KS
Security Screws
R
Catalog No: SN2 Oil Rubbed Bronze BHMA 613 Finish
Catalog No: SN2 Brushed Chrome BHMA 626 Finish
Catalog No: SN2 Brushed Brass BHMA 606 Finish
Catalog No: SN2 Stainless Steel BHMA 630 Finish
The #10-32 kit is available in (4) finishes:
p/n: 101617-X
Catalog No: SSK3
Tamper Kit
(Security Kit)
Sex Nut
Catalog No: 94 Security screws
p/n: 102212-1
Catalog No: 95 - Standard screws
p/n: 102212-2
Double Door Strike Kit
Narrow Stile Door Kit
Optional Accessories
CatalogNo:GB2-GlassBeadKit,40series
p/n: 101644
Glass Bead Kit
#1/4-20 X 1-1/2" Screw
bits provided
(SpliceKitmaybeusedwitheither3-0or4-0units)
Catalog No: NSK1
p/n: 101879-1 (628 Finish, Clear)
p/n: 101189-2 (711 Finish, Black)
The following Models in the series were evaluated by UL: Controlled Exit Panic Devices; Model V40. These devices may
be suffixed with 01, 02, 03, 08, 09, or 14 followed by A, AN, BN, CN, DN, DNT, DNU, MN, P, PN or WS, followed by BP2
orBP8followedby6
05, 606, 611, 612, 613, 625, 626, 628, 629, 630, or 711 followed by the RHR or LHR, followed by EB,
EH or EHxR, which may be followed by LD or CD, followed by 628 or 711, followed by 98 or 99, followed by 36 or 48.
This manual suits for next models
4
Table of contents
Other Detex Security System manuals
Popular Security System manuals by other brands

eTIGER
eTIGER secual box user manual

Omntec
Omntec Proteus Delivery Defender Series installation guide

Elektrotechnik Schabus
Elektrotechnik Schabus GX-C3 operating instructions

Visonic
Visonic SR-720B PG2 installation instructions

Vacron
Vacron VDH-NK360 Hardware manual

VSN Mobil
VSN Mobil V.ALRT quick start guide