DH Lifelabs Sciaire Pro + HEPA User manual

Sciaire Pro + HEPA
INSTRUCTION MANUAL
Created by nature.
Engineered by science.

All the things you
need to know are here.
Safety Instructions ...................1
Product Overview ...................3
How It Works.......................4
Unpacking and Setup ................4
Getting Started .....................5
Connectivity .......................5
Control Panel.......................6
Air Quality Indicator .................6
Filter Replacement ..................7
Cleaning and Maintenance ............7
Device Specications ................8
Troubleshooting ....................9
Product Warranty ..................10
FCC Statement ....................11
Thank you for your purchase.
Now you can breathe easy.
Sciaire Pro + HEPA incorporates a 2-in-1 high
efciency particulate air (HEPA) lter, an activated
carbon lter with a plasma generator to efciently
lter indoor air, removing particulate matter with a
diameter of less than 2.5 microns (PM2.5). It can also
absorb harmful chemicals such as formaldehyde,
smoke, volatile organic compounds (VOCs) and other
harmful gases with an activated carbon lter. It is a
comprehensive solution to remove the contaminants
from the air you breathe.

12Copyright © 2022 Dernier & Hamlyn Inc. All rights reserved.
!DO NOT allow foreign objects to enter
ventilation or exhaust opening as this
may cause electric shock or damage to
the device.
!DO NOT block air outlets or intakes.
!Locate the device near an outlet and
avoid using an extension cord or power
strip.
!Do not handle any part of the plug with
wet hands.
!This appliance has a three-pronged
polarized plug. If the plug does
not t fully in the outlet, please
nd a compatible power supply.
DO NOT attempt to defeat this safety
feature.
!Ensure the electrical outlet used with
the machine is not loose or damaged. A
poor electrical connection can result in
electric shock, overheating or damage to
the power cord and device. If the outlet
needs to be serviced, do not use the
outlet and contact a licensed electrician
for repairs.
!Do not use any electrical appliance that
has a damaged power cord or plug.
!To disconnect the unit, make sure it is
powered OFF then grip the plug and pull
it from the wall outlet. NEVER pull the
cord to unplug it.
!Do not use any electrical product that
you believe may be faulty product, or
that has been dropped or damaged in
any way.
!Keep the power cord away from hot
surfaces.
!Do not route the power cord under
carpet or cover it with carpet. Route the
power cord to minimize the possibility
that someone could trip over it.
!Do not expose the device to excessive
moisture. Avoid operating it where it
might come in contact with water, such
as bathrooms, laundry rooms or other
damp places.
!Disconnect the power before cleaning or
servicing the device.
!This device complies with the maximum
allowable concentration of ozone of
0.050 parts per million by volume (ppmv)
in a 24 hour period.
!Place the unit where it is unlikely to be
bumped or overturned.
!DO NOT sit, stand, or place heavy
objects on the unit.
!The unit must only be used in the upright
position.
!Do not cover the machine while in use.
!Do not use the machine on a soft or
unstable surface. Always place the
machine on a rm, at, level surface.
!Do not move the device when operating.
!Do not use the device outdoors.
!NEVER place liquid containers, including
drinks on top of the unit. Spilling liquids
into the unit can damage the machine
and potentially cause a shock or re
hazard.
!Children should not use this equipment
alone. Keep small children and pets
away from the device.
!This device is not intended for use
by persons with reduced physical,
sensory or reasoning capabilites or lack
of experience or knowledge unless
they have been given supervision or
instruction concerning the use of the
device by a person responsible for their
safety.
!NEVER use the device unless it is fully
assembled.
!This product can only be used with the
supplied accessories. !
Read all safety
instructions in the
instruction manual,
and on device.
Your safety is important to us.
Read all safety instructions before
you use the device.
WARNING! TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR INJURY PLEASE ADHERE
TO THE FOLLOWING:
!

13
1. Main Body
2. Control Panel with IAQ Light Ring
3. PlasmaShield™ Technology (inside)
4. 2-in-1 HEPA Filters (2)
Activated Carbon Filters (2)
5. Side Panel
6. Door Handle and Lock
7. Casters
8. Key and Hook
Product Overview
1
2
3
4
56
7
8
4Copyright © 2022 Dernier & Hamlyn Inc. All rights reserved.
How It Works
Sciaire Pro + HEPA incorporates a 4-stage cleaning system to help clean the air. A fan
forces air through the unit from bottom to top. There are four stages to the unit:
Stage 1: Pre-lter. Captures large particulate matter including dust, pollen, hair and pet
dander.
Stage 2: HEPA Filter. The true High Efciency Particulate Air (HEPA) lter captures up to
99.97% of particles down to 0.3 microns in diameter.
Stage 3: Activated Carbon Filter. The true High Efciency Particulate Air (HEPA) lter
captures up to 99.97% of particles down to 0.3 microns in diameter.
Stage 4: Active Plasma Set . The active plasma set generates positive ions and negative
ions that are diffused into the air. These ions keep killing bacteria and viruses in the room.
As the room is lled with negative oxygen ions, you will enjoy a fresh smell - like the
forest after a rain shower. The ozone generated is well within US EPA safety limits and the
optimum concentration (less than 0.05ppm).
Unpacking and Setup
1. Remove the device from the box and make sure all the items shown in the product
overview are included. It is a good idea to retain the packaging for storing the unit
or in the event it must be shipped back for service.
2. The device is shipped with the lters sealed inside a protective plastic bags. Open
the door with the key and remove the plastic, then replace them inside and close
the door.
3. Place the unit on a at, solid surface in proximity to an AC electrical outlet.
4. Connect the AC adapter to the unit, and route the power cord to the outlet, but
do not plug it in yet. Make sure that the power cord is out of the way and does not
pose a tripping hazard, and is out of reach of children and pets.

On/Off
Powers the unit on
and off
Auto Mode
Blue: Air Quality Good
Yellow: Air Quality Moderate
Red: Air Quality Poor
Fan Speed
(1/2/3) Three fan speeds
Timer (4H/8H/12H)
Set the timer to have the
device turn off automatically
Wi-Fi Indicator
Flashing amber: Attempting to connect
Steady amber: Connection successful
Steady red: Not connected
Connect/disconnect: Short press
Filter Replacement
Indicator & Reset
It will remind to change new lters
(1#2-in-1 HEPA lter, 2# Activated
Carbon Filter). Press for 3s to reset the
lter lifetime counting.
Safety Lock
Prevent misuse or
accidental touch
6Copyright © 2022 Dernier & Hamlyn Inc. All rights reserved.5
Unlock by the key
and open the door.
Close the door. Plug
in and press the power
button to turn on.
Remove all protective
plastic from the HEPA
and activated carbon
lters, then reinstall.
123
Getting Started
Connectivity
Sciaire Pro + HEPA can connect with your smartphone
when you download the DH Lifelabs App. Follow the
steps in the app or steps below.
DH Lifelabs App
GET IT ON
GET IT ON
1. Download the DH Lifelabs and enable Bluetooth and Network settings.
2. Turn on the Sciaire Pro + HEPA.
3. Open DH Lifelabs app and click "+" to connect the device.
4. When the app indicates, press and hold the Wi-Fi Indicator for 3 seconds.
5. The app should connect to the device over your Wi-Fi network and the Wi-Fi
Indicator will illuminate amber. To disconnect from the network, press the Wi-Fi
Status Indicator/Button. The unit will beep and the indicator will ash red.
Control Panel
Air Quality Indicator
Good Moderate Poor

Copyright © 2022 Dernier & Hamlyn Inc. All rights reserved.
Cleaning and Maintenance
When the device is not used for an extended time, store it in a cool dry place. Do not
store the device where it might be exposed to excess moisture or direct sunlight. The
device may not operate effectively in very low temperatures. The device can be damaged
when exposed to sub-freezing temperatures. Use a dry cloth to clean the exterior of the
device. Do not use any chemicals or cleaners.
87
Filter Replacement
2-in-1 HEPA Filter Replacement
The lter should be replaced every 12 months or whenever indicated by the Filter
Replacement Indicator/Button on the Control Panel. However this interval is intended as
a guideline only. In environments with a high concentration of contaminants such as dust,
pet dander, or cigarette/cigar smoke you may need to replace the lter more frequently.
Activated Carbon Filter Replacement
The lter should be replaced every 6 months or whenever indicated by the Filter
Replacement Indicator/Button on the Control Panel.
1. Make sure the Purier is OFF and unplugged.
2. Open the side panel with the key.
3. Remove and replace the replacement 2-in-1 HEPA lter/ Activated Carbon lter,
then close the door and lock it with the key.
NOTE: Ensure that the pull tabs are facing outward to facilitate lter
removal later.
4. Turn on the Purier. After replacing the lter, press and hold Filter Reset Button for 3
seconds to reset the lter life countdown.
NOTE: Both HEPA lter and activated carbon lter is not washable. DO NOT
immerse it in water.
Device Specifications
Power Consumption 230 Watts
Input Voltage 120VAC 60Hz
Fan Speed 3 levels (1/2/3)
Noise Max. 59 dB
CADR (clean air delivery rate)
Smoke 665.1CFM
Pollen 703.04CFM
Dust 674.85CFM
Timer 4H/8H/12H
Material & Finish Glossy White, Stainless Steel Accents
Recommended Room Size 1937 square feet
Reminder Filter Replacement Reminder:
2-in-1 HEPA lter, Activated Carbon Filter
Dimensions (Machine) 36.5 X 23.6 X 14.6 inches (927*600*370mm)
Net Weight 69.45 lbs (31.5 kg)

Symptom Probable Cause/Solution
Purier does not operate.
Power cord not securely plugged into outlet. Make
sure plug is securely inserted.
No AC power. Check fuse or circuit breaker. Replace
fuse with a time delay type or reset the circuit
breaker.
Purier is starting to make
noise and the air output
is low.
2-in-1 HEPA lter/Carbon lter may be dirty or
obstructed. Replace lter.
Air coming from Purier
has a bad odor.
The rst time you use the Purier, you might perceive
a plastic or paint smell. This is normal, but it should
disappear quickly. If the smell persists or if you sense
a burning smell, please disconnect the unit and
contact Customer Support.
Air quality does not
improve as the Purier
operates.
Windows or doors are open. Constant introduction
of dirty air from outside the room can reduce the
effectiveness of the Purier. Close all exterior doors
and windows.
Fan does not operate.
Side panel is not securely fastened/in place. Ensure
side panel is closed and locked. If fan still does not
work, contact Customer Support.
Fan speed does not
change after selecting a
new fan speed.
The fan speed will decrease or increase gradually,
this is normal. If fan speed does not change after a
prolonged period of time after changing the setting
contact Customer Support.
The appliance is very loud.
Ensure that there are no obstacles near the appliance
and that it has a minimum of 12 inches (30 cm) of
clearance around it for optimal operation.
The app does not
operate properly or it
is not possible to sync
the purier with the DH
Lifelabs smartphone app.
APP only applies to CAHP-180WH10CPro Wi-Fi
enabled model. If the device is the Wi-Fi enabled
model but still not work, contact Customer Support.
Troubleshooting
Copyright © 2022 Dernier & Hamlyn Inc. All rights reserved. 10
Product Warranty
This 2 year limited warranty applies to repair or replacement of product found to be
defective in material or workmanship. This warranty does not apply to damage resulting
from commercial, abusive, unreasonable use or supplemental damage. Defects that are
the result of normal wear and tear will not be considered manufacturing defects under
this warranty.
DH Lifelabs IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF
ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE
DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential
damages or limitations on how long an implied warranty lasts, so the above limitations
or exclusions may not apply to you. This warranty gives you specic legal rights, and
you also may have other rights which vary from jurisdiction to jurisdiction. This warranty
applies only to the original purchaser of this product from the original date of purchase
At its option, DH Lifelabs will repair or replace this product if it is found to be defective
in material or workmanship. This warranty does not cover damage resulting from any
unauthorized attempts to repair or from any use not in accordance with the instruction
manual. This warranty does not cover the lter except for material or workmanship
defects.
9

FCC Statement
Supplier's Declaration of Comformity:
Trade Name: DH Lifelabs
Models: CAHP-180WH10Pro, CAHP-180WH10CPro
Responsible Party: Dernier & Hamlyn Inc.
Address: Dernier & Hamlyn Inc., 720 Northgate Parkway, Wheeling, IL 60090
Telephone Number: 1-877-548-9722
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Caution: The user is cautioned that changes or modications not expressly approved
by the party responsible for compliance could void the user’s authority to operate
the equipment. Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
• receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
11 Copyright © 2022 Dernier & Hamlyn Inc. All rights reserved. 12

EPA EST. NO. 99117-CHN-1
MADE IN CHINA
*The Sciaire + HEPA uses Plasma Technology.
**Dispose used products according to local regulations.
Apple and the Apple logo are trademarks of Apple Inc.,
registered in the U.S. and other countries. App Store is a
service mark of Apple Inc., registered in the U.S. and other
countries.
Need Help?
1-877-548-9722
9 AM–6 PM, CST, Monday–Friday
Dernier & Hamlyn Inc.
720 Northgate Parkway
Wheeling, IL 60090
Other manuals for Sciaire Pro + HEPA
1
This manual suits for next models
2
Table of contents
Other DH Lifelabs Air Cleaner manuals

DH Lifelabs
DH Lifelabs Sciaire Portable User manual

DH Lifelabs
DH Lifelabs Sciaire+HEPA User manual

DH Lifelabs
DH Lifelabs Sciaire Mini + HEPA User manual

DH Lifelabs
DH Lifelabs Sciaire Mini + HEPA User manual

DH Lifelabs
DH Lifelabs Sciaire Pro + HEPA User manual

DH Lifelabs
DH Lifelabs Aaira Mini User manual

DH Lifelabs
DH Lifelabs Sciaire + HEPA User manual

DH Lifelabs
DH Lifelabs Sciaire Mini + HEPA User manual

DH Lifelabs
DH Lifelabs Sciaire Mini CAHP-20WC01C User manual

DH Lifelabs
DH Lifelabs AQUASOLVO AAHE-50WC04C User manual