208433
© di-soric | Subject to modifications | 07/07/14 | Page 1 (2)
SLB2-1505
Safety light curtain
di-soricGmbH & Co. KGSteinbeisstraße 6DE-73660 Urbach
Fon + 49 (0) 71 81 / 98 79 - 0
F
ax + 49 (0) 71 81 / 98 79 - 179
[email protected]www
.di-soric.com
TECHNICAL INFORMATION (typ.)+20°C, 24 V DC
Safety levelT ype 2: IEC/TS 61496-2 SIL 2-SILCL 2 IEC 61508-IEC 62061 PL
d-Kat. 2 ISO 13849-1
Security levelBody protection
T otal height (A)1.563 mm
Protective field height (B)1.510 mm
mBasic
MountingT-shaped slot (Backside), / Holder SFB E 180 (optional)
Number of beams40
Emitted lightInfrared, 950 nm
Safey outputPNP (2x), 400 mA / 24 V DC
Service voltage19,2 ... 28,8 V DC
Operating distance4 m (Low Range) / 12 m (High Range)
Resolution50 mm
Inverse polarity protectionY es
DisplayLEDs for light curtain´s status and diagnostic
Start / restartAutomatic
Short-circuit protectionyes
Reaction time11,5 ms
Readiness delay< 2 s
Self diagnosticEvery 500 ms (2 Hz)
Ambient temperature-10 … +55 °C
Protection classIP 65, IP 67
Protection degreeIII, operation on protective low voltage
0 V DC
BU
3PE
GY
5
RANGE 0
WH
2
24 V DC
BN
1
RANGE 1
BK
4
24 V DC
BN
PE
GY
0 V DC
BU
OSSD1
WH
OSSD2
BK
1
2
3
4
5
Sender 5-polig
Emitter 5 poles
Empfänger 5-polig
Receiver 5 poles
Safety instructions
All the installation, connection and safety regulations, as per our technical
information, have to be strictly adhered to.
The set-up of the products have to be made by skilled staff, only .
Repair exclusively made by di-soric.
Attractive priced solution for safety level 2
Resolution for body protection and presence control
Protection area until end of profile
Parameterisation via connecting cable
Easy and fast startup
Automatic Start/Restart
For Modular Safety Controller / safety relays
Unshielded connecting cables to 100 m
High protection class