Digiplex & DigiplexNE - 11 - Modules Programming Guide
Outdoor High-Security Digital Motion Detector Modules
OPERATIONAL MODE
Digigard DG85 can function in two operational modes (see Table 4 below): DGP2 Mode or Relay Mode. When set to Relay Mode, DG85 functions as would
any standard motion detector by communicating its alarm and tamper signals via relays. When set to DGP2 Mode, DG85 functions like a DGP2 motion
detector module by communicating alarm signals, tamper signals, data and detector settings via the combus. In DGP2 Mode, both section programming and
manual programming can be used to program the settings. In Relay Mode, only manual programming can be used to program the settings (see Table 4
below). Refer to DG85’s connection drawing on page 33 for the location of the DIP switches.
DIP Switch 1:OFF = Relay Mode (default)
ON = DGP2 Mode
SETTINGS
Refer to DG85’s connection drawing on page 33 for the location of the DIP switches and Trimpot.
Table 4: DG85 Settings
UDefault Setting
1When in DGP2 Mode only (see Operational Mode above).
2When in DGP2 Mode or Relay Mode (see Operational Mode above).
3This feature is always enabled in Relay Mode.
4To set the sensitivity manually, remove the front cover and, using a screwdriver, turn the trimpot clockwise to increase the detector’s sensitivity or
counter-clockwise to decrease it. You can turn the trimpot 360° in both directions. To determine the sensitivity setting, remove the cover and view how
many times the LED flashes. The number of times the LED flashes corresponds to the sensitivity setting. Thus if the sensitivity is set to 6, the LED will flash
6 times.
In instances where a particular setting can be set either manually or through section programming, a discrepancy may exist between the
setting of the DIP switches and the setting in the appropriate sections. In such cases, the last change that is made will dictate the setting.
For example, if you disable the LED from within section programming, the DIP switch will still show that it is enabled, however the LED is
actually disabled.
Feature Setting
Programming
Section Programming1Manual Settings2
Signal Processing Mode
Single [001]J[1] = OFF DIP switch 2 = OFF
Dual U[001]J[1] = ON DIP switch 2 = ON
LED
Disabled [001]J[2] = OFF DIP switch 3 = OFF
Enabled U[001]J[2] = ON DIP switch 3 = ON
Movement Signal Indication
Disabled [001]J[3] = OFF
Enabled when DIP switch 3 = ON
Enabled U[001]J[3] = ON
Tamper Recognition3Disabled U[001]J[5] = OFF N/A
Enabled [001]J[5] = ON N/A
Sensitivity U= 10 seconds [002]J001-010 TrimpotJ0-104
DG85
Digiplex & DigiplexNE - 29 - Modules Programming Guide
Module Connection Drawings
MODULE CONNECTION OVERVIEW
Digiplex & DigiplexNE - 33 - Modules Programming Guide
OUTDOOR HIGH-SECURITY DIGITAL MOTION DETECTOR MODULE (DG85)
PRINTED IN CANADA 05/2003 MODULES-EP05

Popular Security Sensor manuals by other brands

Risco BWareBus RK515DTBGL quick start guide

Risco

Risco BWareBus RK515DTBGL quick start guide

Bentel Security RAY60 quick start guide

Bentel Security

Bentel Security RAY60 quick start guide

AltumView AVG20WF5 user manual

AltumView

AltumView AVG20WF5 user manual

Titan TP200 manual

Titan

Titan TP200 manual

CPAT FLEX DRV3 user manual

CPAT

CPAT FLEX DRV3 user manual

UTC Fire and Security interlogix VE1120 Series Installation sheet

UTC Fire and Security

UTC Fire and Security interlogix VE1120 Series Installation sheet

DOLD Safemaster W UH 6900 user manual

DOLD

DOLD Safemaster W UH 6900 user manual

Neostar Twin Solar Security Spotlight instruction manual

Neostar

Neostar Twin Solar Security Spotlight instruction manual

Takex PA-6614E instruction manual

Takex

Takex PA-6614E instruction manual

Leica LASER ALIGNMENT DIGICAT 100 user manual

Leica

Leica LASER ALIGNMENT DIGICAT 100 user manual

Tractel Blocfor B10 AES Operating and maintenance instructions

Tractel

Tractel Blocfor B10 AES Operating and maintenance instructions

B.E.G. Luxomat PD2-DIM Series Installation and operating instructions

B.E.G.

B.E.G. Luxomat PD2-DIM Series Installation and operating instructions

WATERGUARD Home Operation and setup guide

WATERGUARD

WATERGUARD Home Operation and setup guide

Velleman PIR416 user manual

Velleman

Velleman PIR416 user manual

Permalert FluidWatch FW25-50 Product data

Permalert

Permalert FluidWatch FW25-50 Product data

Scott Safety PAK-ALERT Operation and maintenance instruction manual

Scott Safety

Scott Safety PAK-ALERT Operation and maintenance instruction manual

Renkforce 1362991 operating instructions

Renkforce

Renkforce 1362991 operating instructions

System Sensor ECO1002 Installation and maintenance instructions

System Sensor

System Sensor ECO1002 Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.