Dino lift Dino 95T User manual

DINO 95
T
OPERATING INSTRUCTIONS
®
Raikkolantie 145
FI-32210 LOIMAA
T. +358 2 762 5900
F. +358 2 762 7160
www.dinolift.com
Manufacturer:
Dealer:

DINO 95T
2

DINO 95T
3
ORIGINAL OPERATING INSTRUCTIONS
Valid from serial number 95003

DINO 95T
4
TABLE OF CONTENTS
1EU DECLARATION OF CONFORMITY ............................................................................6
2REACH DIAGRAM.................................................................................................................7
3DIMENSION DRAWING........................................................................................................8
4TECHNICAL SPECIFICATION............................................................................................9
4.1 EXAMPLE OF THE MACHINE’S NAMEPLATE............................................................................9
4.2 GENERAL DESCRIPTION OF THE MACHINE............................................................................10
4.3 DESCRIPTION OF THE MACHINE’S INTENDED USE.................................................................10
5GENERAL SAFETY REGULATIONS................................................................................11
5.1 !! INSTRUCTIONS FOR SAFE OPERATION!..............................................................................13
6INSPECTIONS........................................................................................................................14
7WORKSITE INSPECTION...................................................................................................15
8OPERATION OF SAFETY DEVICES ................................................................................16
9OPERATING CONTROLS...................................................................................................17
9.1 OPERATING CONTROLS ON CHASSIS CONTROL PANEL ......................................17
9.2 OPERATING CONTROLS FOR OUTRIGGERS.............................................................18
9.3 OPERATING CONTROLS ON THE PLATFORM..........................................................19
10 MEASURES TO BE TAKEN IN CASE OF EMERGENCY/AT RISK OF LOSING
THE STABILITY..........................................................................................................................21
11 START-UP ...........................................................................................................................22
11.1 OPERATING THE LIFT FROM THE CHASSIS PANEL.............................................25
11.2 OPERATING THE LIFT FROM THE PLATFORM PANEL........................................26
12 EMERGENCY DESCENT SYSTEM................................................................................30
13 DRIVING DEVICE (OPTION)..........................................................................................31
14 DRIVING DEVICE (OPTION)..........................................................................................32
15 SPECIAL INSTRUCTIONS FOR WINTER USE...........................................................33
16 MEASURES TO BE TAKEN AT THE END OF THE WORKING DAY....................34
17 PREPARING THE LIFT FOR TRANSPORT.................................................................35
18 INSTRUCTIONS FOR SERVICE AND MAINTENANCE ...........................................37
18.1 GENERAL SERVICE INSTRUCTIONS.......................................................................37
18.2 SERVICE AND INSPECTION INSTRUCTIONS.........................................................38
18.3 LUBRICATION PLAN ..................................................................................................39
18.4 LONG-TERM STORAGE..............................................................................................40
18.5 LOAD HOLDING AND LOAD REGULATION VALVES..........................................41
18.6 WHEEL BRAKES AND BEARINGS............................................................................43

DINO 95T
5
18.7 LEVELLING SYSTEM OF THE PLATFORM .............................................................45
18.8 REGULAR SERVICING................................................................................................46
19 INSPECTION INSTRUCTIONS.......................................................................................52
19.1 FIRST INSPECTION......................................................................................................52
19.1.1 SAMPLE OF INSPECTION PROTOCOL FOR THE ACCESS PLATFORM...53
19.2 DAILY INSPECTION (START-UP INSPECTION) .....................................................55
19.3 MONTHLY INSPECTION (MAINTENANCE INSPECTION)....................................56
19.4 ANNUAL INSPECTION (REGULAR INSPECTION) .................................................57
19.5 EXTRAORDINARY INSPECTION..............................................................................60
19.6 TEST LOADING INSTRUCTIONS FOR REGULAR INSPECTION..........................61
20 FAULT FINDING ...............................................................................................................62
21 GENERAL INFORMATION OF HYDRAULICS ..........................................................68
22 ELECTRIC COMPONENTS.............................................................................................70
22.1 CHASSIS CONTROL CENTRE (LCB), RELAYS........................................................70
22.2 CHASSIS CONTROL CENTRE (LCB), SWITCHES...................................................70
22.3 CHASSIS CONTROL CENTRE (LCB), OTHER ITEMS.............................................71
22.4 PLATFORM CONTROL CENTRE (UCB), SWITCHES..............................................71
22.5 PLATFORM CONTROL CENTRE (UCB), OTHER ITEMS........................................72
22.6 LIMIT SWITCHES.........................................................................................................72
22.7 OTHER MARKINGS.....................................................................................................72
23 ELECTRIC COMPONENTS 95T 95001 -> .....................................................................73
24 ELECTRIC DIAGRAM 95T 95001 ->..............................................................................75
25 HYDRAULIC COMPONENTS 95001 -> .........................................................................86
26 HYDRAULIC DIAGRAM 95001->...................................................................................87

DINO 95T
6
1 EU Declaration of Conformity
EU Declaration of Conformity
Dinolift Oy
Raikkolantie 145
FI-32210 Loimaa,
which has authorised the Chief Engineer Mr. Seppo Kopu to draw up the Technical
Construction File
declares that
DINO 95T Access Platform no YGC 0D95T X X XXXXXX
complies with the provisions of the Machine Directive 2006/42/EC and its
amendments as well as the national decree, through which they have been
brought into effect as well as the regulations of the Low Voltage Directive
2000/14/EC and the EMC Directive 2004/108/EC.
Notified body nr. 0044,
TÜV NORD CERT GmbH
Langemarckstrasse 20
DE-45141 ESSEN,
has granted the certificate No. 44 205 378348
In designing the machine, the following harmonized standards have been
applied:
EN 280/A1+A2; DIN EN 60204-1/A1
Loimaa 12.04.2010
(place) (date)
-----------------------------------------
(signature)
Seppo Kopu
Chief Engineer
(name in block letters, position)

DINO 95T
7
2 REACH DIAGRAM

DINO 95T
8
3 DIMENSION DRAWING

DINO 95T
9
4 TECHNICAL SPECIFICATION
Max. working height 9.7 m
Max. platform height 7.7 m
Max. outreach 5.6 m
Boom rotation continuous
Turn area refer to reach diagram
Support width 3,60 m / 3,90 m
Transport width 1.72 m
Transport length 5.52 m
Transport height 1.96 m
Weight 1,160 kg
Max. allowed load on platform 200 kg
Max. number of persons + additional load 1 person + 120 kg
Max. allowed sideways load (caused by persons) 200 N
Max. lateral inclination (chassis) ±0,3°
Max. wind speed during operation 12,5 m/s
Min. ambient temperature when working -20 °C
Max. support force on the outriggers 9,500 N
Platform size Ø 0,85 m
Gradeability using the driving device (optional) 25%
Power supply:
-mains current: 230V / 50Hz / 10A
-Sound pressure level Under 70 dB
-internal combustion engine (optional) 4.8 kW (6.5 hp)/ 3600 r/min
-Sound pressure level 92 dB
Socket outlets on the platform 230V / 50Hz / 10A
4.1 Example of the machine’s nameplate

DINO 95T
10
4.2 General description of the machine
The denominations of the machine’s essential parts and concepts, which are used later in these
instructions, are described on this page.
4.3 Description of the machine’s intended use
The Access Platform is exclusively intended for transferring people and tools and acting as a
work platform to the limit of its load-bearing capacity and reach (refer to the table of
Technical Specifications and Reach Diagram).
The intended use also covers:
-Following all the instructions in the Operating Instructions
-Performance of the inspections and maintenance operations

DINO 95T
11
5 GENERAL SAFETY REGULATIONS
Make yourself familiar with these operation instructions before using the lift!
-Keep these operating instructions in the place reserved for them.
-Make sure that all users of the lift are familiar with these instructions.
-Advice the new users and strictly follow all instructions given by the manufacturer.
-Make sure you clearly understand all instructions relating to the operational safety of the lift.
Always use chocks under the wheels when disconnecting the lift from the car.
Only specially trained personnel with authorisation in writing from the employer who are
well familiarised with the device and at least 18-years old are allowed to operate the lift
-The max. allowed load on the platform is one (1) person and at maximum hudred twenty (120)
kg of additional load, however, the total load must not exceed one two hundred (200) kg.
-The platform may only be operated when the chassis is well supported and the wheels are off
the ground.
-The load-bearing capacity and the gradient of the base must be taken into account when
supporting the chassis.
-Additional support plates of adequate size must be used under the outriggers when working on
soft ground. Only use such additional support plates on which the metallic outriggers will not
slide.
The lift may only be moved in the transport position. No persons or load are allowed on the
platform during the transportation.
The weather conditions, such as wind, visibility and rain, must always be taken into account so
that these factors will not adversely affect the safe performance of the lifting operations.
The use of the lift is prohibited if
-the temperature drops under - 20 °C or
-the wind speed exceeds 12.5 m/s
PROTECT YOUR HEARING WHILE USING THE POWER UNIT (OPTIONAL) 92 dB
USE THE SAFETY HARNESS
Connecting points
for the safety
harness.
1 person/lug

DINO 95T
12
Do not use ladders, steps or other similar equipment on the platform.
Never throw any objects from the platform.
The lift must not be used for transferring goods or persons between different floors or working
levels.
Always make sure before lowering the platform that the area on the underside is clear of any
obstructions.
Avoid damaging the platform by lowering it on the ground or bringing it in contact with any
structures.
When working in busy areas the operating range of the lift must be clearly marked either by using
warning lights or fencing.
Also observe the regulations of the Road Traffic Act.
Beware of the live aerial power lines in the area - observe the minimum safety distances:
Keep the lift clean of any dirt which may impair the safe operation and impede the inspection of
the structures
The device must be serviced and inspected regularly.
Only skilled persons who are familiar with the service and reparation instructions are allowed to
carry out the service and reparation work.
It is strictly prohibited to use a lift which is out of order.
The operator must be given instructions and consent from the manufacturer
for all such specific work methods or conditions, which the manufacturer has
not explicitly defined
The device must neither be altered without the manufacturer’s consent nor be used under
conditions which do not meet the requirements set by the manufacturer.
Voltage Min. distance below
(m) Min. distance at the
side (m)
100 – 400 V hanging spiral
cable 0,5 0,5
100 – 400 V open-wire cable 2 2
6 – 45 kV 2 3
110 kV 3 5
220 kV 4 5
400 kV 5 5

DINO 95T
13
5.1 !! Instructions for safe operation!
-Use a safety harness while on the platform.
-Use hearing protectors when operating the power unit (optional) from the chassis panel.
Sound pressure level 92 dB.
-Never load the platform while in the upper position.
-The lift must not be used when the temperature is below -20°C and the wind speed
exceeds 12.5 m/s.
-Beware of live power lines within the work area.
-The lift MUST NOT be used as a crane.
-Always ensure the load-bearing capacity of the standing surface.
-Ensure the unobstructed range of movement before operating the outriggers.
-While in the support position, ensure that the wheels are off the ground.
-Always verify the horizontal position of the machine.
-Ensure that the outriggers cannot slide while on a gradient.
-Always ensure that the work area is clear of outsiders. Danger of getting squeezed
between rotating and fixed structures.
-Stepping on or off the platform in motion is prohibited.
-The maximum-allowed gradient during transfers is 5°. During transfer in rough terrain,
try to stay above the machine.
-While operating the boom from the control panel on the turning device, beware of
getting pressed against the outriggers or other structures that do not turn with the boom.
-When the boom is in its lowest positions, make sure it cannot clash during rotation with
structures that do not turn with the boom.
-Before operating, always ensure that the safety devices and the emergency descent
system are in working order.
-Do not take tools/material of large surface area onto the platform. The increase in wind
load may jeopardize the stability of the device.
-Always keep the lift free from dirt, snow and ice.
-Ensure that the lift is inspected and serviced, before use.
-Never use a defective lift.

DINO 95T
14
-Never use a lift alone. Make sure, there is always someone on the ground, who can call
for help in case of an emergency.
6 INSPECTIONS
A thorough inspection of the lift must be carried out at least once every twelve (12) months.
The inspection shall be carried out by a technically trained person who is familiar with the
operation and structure of the lift.
Draw up a protocol of the inspections and keep it always with the unit stored in the space reserved
for it.
Carry out the inspections on regular basis throughout the service life of the lift.
The inspection must be carried out within twelve (12) months from the first or the previous
inspection.
If the lift is used under extreme conditions, intervals between the inspections shall be reduced.
The overall operating condition of the lift as well as the condition of the safety-related control
devices shall be established in the regular inspections. Particular attention shall be paid to changes
which affect the operational safety.
In connection with the regular inspection, it shall be established to what extent the lessons and
practical experience gained from the previous inspection can be implemented for even better
safety.
NOTE! Primarily the national legislation must be followed!
Regular inspections and service measures are described more thoroughly in the chapter "Service-
and maintenance".

DINO 95T
15
7 WORKSITE INSPECTION
1. General information
-Is the lift suited for the intended job?
-Is the performance of the lift sufficient for the job? (reach, loadability etc.)
-Is the position of the lift safe?
-Is the lighting on the worksite sufficient?
2. Documents
-Are the Operation and Service Instructions for this lift present? (Manufacturer´s
instructions)
-Are inspections and servicing carried out in accordance with the instructions and have the
defects affecting the safety been checked as repaired?
(Inspection protocols)
3. Structure (Visual inspection and operational test)
-General condition of the lift
-Operation and protection of the controls
-Emergency stop, signal horn and limit switches
-Electrical appliances and wiring
-Oil leaks
-Load markings and signs
4. Operator
-Is the operator old enough?
-Has the operator received the required training?
5. Special issues on the work site
-Are there any additional regulations relevant to the worksite or the work?

DINO 95T
16
8 OPERATION OF SAFETY
DEVICES
1. Support outriggers
The safety limit switch RK3 prevents the
operation of the outriggers and the driving device
when the boom does not rest on the transport
support. The switch is located on the tow-bar at
the transport support.
2. Lifting of the boom
All the lift’s support outriggers must be in the
support position before the boom is lifted. Make
sure that the wheels are off the ground. The safety
limit switches RK11, RK12, RK13 ja RK14 are
located on the support outriggers.
3. As the emergency stop button is depressed all movements stop and the power unit is
turned off. The emergency stop pushbutton must be pulled up before the power unit can be

DINO 95T
17
restarted (buttons 5 and 20)
Check operation of the safety devices.
9 OPERATING CONTROLS
9.1 OPERATING CONTROLS ON CHASSIS CONTROL PANEL
1. Selector switch
1a - ignition off
1b -outriggers, hydraulic drive and operating the boom from the
chassis panel
1c -controlling the boom from the platform panel
2. Start button
3. Stop button
4. I/ II - speed (is used simultaneously with the control levers for the boom and the
driving device)
5. Emergency stop button
6. Lever for turning
7. Lever for boom system
8. Lever for telescope movement
9. Lever for platform inclination
10F. Drive to the front
10B. Drive to the rear
10F. Drive to the right (forward)
10F. Drive to the left (forward)
10B 44Ah Drive to the right (backward)
10B+10L Drive to the left (backward)
11. Signal light for the outrigger
limit switches
12. Automatic fuse for socket
outlets
13. Voltage meter
14. Hour meter

DINO 95T
18
9.2 OPERATING CONTROLS FOR OUTRIGGERS
22. Rear outrigger, right
23. Rear outrigger, left
24. Front outrigger, left
25. Front outrigger, right
26. Position indicator of chassis

DINO 95T
19
9.3 OPERATING CONTROLS ON THE PLATFORM
Close the cover of the chassis control panel before operating the platform controls.
15. Control lever
TELESCOPE IN
TELESCOPE OUT
16. Control lever
BOOM UP
BOOM TO THE LEFT
BOOM TO THE RIGHT
BOOM DOWN

DINO 95T
20
17. I/ II - speed (is used simultaneously with the control levers for the boom and the levelling of
the platform)
18. Control lever for levelling of the platform
19. Sound signal
20. Emergency stop button
21. Socket outlet 230VAC/ (2 pcs.)
Table of contents
Other Dino lift Scissor Lift manuals
Popular Scissor Lift manuals by other brands

BERG
BERG BENOMIC S 350 Technical handbook

Hy-Brid Lifts
Hy-Brid Lifts SERIES II MAINTENANCE & TROUBLESHOOTING MANUAL

WERTHER INTERNATIONAL
WERTHER INTERNATIONAL SATURNUS 50R Original instructions

JLG
JLG AM Series Service and maintenance manual

Vestil
Vestil EHLTX-Series instruction manual

GMG
GMG 1230i Operator's manual