Temperature and humidity controller
for seasoning-maturing cabinets
XLH360
XLH360XLH360
XLH360
C
CC
COOL
OOL OOL
OOL M
MM
MATE
ATEATE
ATE
Operating Instructions

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 2/16
C
CC
COOL
OOLOOL
OOLM
MM
MATE
ATE ATE
ATE
XLH3
XLH3XLH3
XLH360
6060
60
INDICE
1. GENERAL WARNING__________________________________________________________ 3
2. GENERAL DESCRI TION ______________________________________________________ 3
3. TEM ERATURE REGULATION __________________________________________________ 3
4. HUMIDITY REGULATION_______________________________________________________ 3
5. FA NS ______________________________________________________________________ 4
6. EXTRACTOR FAN ____________________________________________________________ 4
7. MATURING CYCLE WITH DRI ING, RUNNING AND STO ING HASE. _______________ 4
8. THE DIS LAY ________________________________________________________________ 6
9. ARAMETER LIST ____________________________________________________________ 8
10. DIGITAL IN UT______________________________________________________________ 10
11. INSTALLATION AND MOUNTING _______________________________________________ 11
12. DIMENSIONS _______________________________________________________________ 13
13. ELECTRICAL CONNECTIONS__________________________________________________ 13
14. HOW TO USE THE HOT KEY __________________________________________________ 13
15. ALARM SIGNALLING _________________________________________________________ 14
10. TECHNICAL DATA ___________________________________________________________ 14
16. XLH360 WIRING CONNECTIONS _______________________________________________ 15
17. DEFAULT SETTING VALUES __________________________________________________ 15

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 3/16
1. GENE AL WA NING
1.1 PLEASE EAD BEFO E USING THIS MANUAL
•This manual is part of the product and should be kept near the instrument for easy and quick reference.
•The instrument shall not be used for purposes different from those described hereunder. It cannot be used as a safety device.
•Check the application limits before proceeding.
1.2 SAFETY P ECAUTIONS
•Check the supply voltage is correct before connecting the instrument.
•Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high
atmospheric humidity to prevent formation of condensation
•Warning: disconnect all electrical connections before any kind of maintenance.
•Fit the probe where it is not accessible by the End User. The instrument must not be opened.
•In case of failure or faulty operation send the instrument back to the distributor or to “Dixell s.r.l.” (see address) with a detailed description of the
fault.
•Consider the maximum current which can be applied to each relay (see Technical Data).
•Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.
•In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with inductive loads could be useful.
2. GENE AL DESC IPTION
The XLH360 is microprocessor controller, suitable for applications on medium or low temperature refrigerating units. It has 6 output relays to control
compressor, heating elements, defrost/extractor fan, fan, de-humidifier/light and humidifier. It has 2 NTC inputs one for thermostat the other one for
defrost. It’s also present a 4÷20mA input for humidity. There is one digital input (free contact) configurable by parameter. An output allows the user
to program the parameter list with the “Hot Key”.
3. TEMPE ATU E EGULATION
The temperature regulation is performed through neutral zone using compressor and heater output relays.
Set point
OFF
ON
• Heating output: CUT IN is “SET TEM -dbt”, CUT OUT is when the temperature reaches the set point.
• Compressor output CUT IN is “ SET TEM +dbt”, CUT OUT is when the temperature reaches the set point.
3.1 DEF OST
During defrost the temperature control is disabled.
If the second relay is configured as defrost: oA2=dEF then two defrost modes are available through the “tdF” parameter: defrost with electrical
heater (tdF=rE) or hot gas (tdF= in). The defrost interval is control by means of parameter “EdF”: (EdF=in) the defrost is made every “IdF” time,
(EdF=Sd) the interval “IdF” is calculate through Smart Defrost algorithm (only when the compressor is ON). At the end of defrost dripping time is
started, set by “Fdt” parameter. To disable the defrost set the MdF parameter to zero
If oA2 is different from dEF, defrost is made only by stopping compressor (tdF=rE).
To disable defrosts set MdF=0.
Humidity regulation during defrost depends on the Hud parameter.
With Hud=no humidity regulation is disabled.
Con Hud=yES humidity regulation is performed also during defrost.
4. HUMIDITY EGULATION
The humidity regulation is performed through neutral zone, by humidifying dehumidifying actions.
Humidity control can be disabled setting the SET % H to “nu” value. In this case only the temperature control is perform.
4.1 HUMIDIFYING ACTION
The humidifying action is done enabling the humidifier relay when the humidity is lower than the “SET %RH-dbH” value.
The relay is switch off when humidity reaches the set values.

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 4/16
4.2 DEHUMIDIFYING ACTION WITHOUT DEHUMIDIFIE ELAY, OA1 DIFFE ENT F OM DEH
In this case the dehumidifying action is performed by setting the following parameters in this way:
tHu = c-H kind of dehumidifying by means of heating and compressor relays
oA1 different from dEH:
The heating and compressor outputs are activated together when humidity is higher than SET %RH+dbH value. Outputs are disabled when humidity
comes back to the SET %RH value.
4.2.1 Relation between cooling, heating and dehumidifying
1. If is simultaneously present a request of cooling (temp>SET TEM +dbt) and dehumidifying (RH > SET %RH+dbH): the cooling action has the
priority over the dehumidifying action: only the compressor relay is energised till the SET TEM is reached at this point also the heating relay
is enabled.
2. If is simultaneously present a request of heating (temp< SET TEM -dbt) and dehumidifying (RH > SET %RH+dbH): the dehumidifying action
has the priority over the heating action: both the compressor and the heating relays are energised till the humidity set is reached at this point
only the heating relay is enabled.
4.3 DEHUMIDIFYING ACTION WITH DEHUMIDIFIE ELAY, OA1 = DEH
The configurable relay is used, setting the parameter oA1 =dEH.
NOTE: the LIGHT button is not more available; Two kinds of de-humidifying are available:
4.3.1 Dehumidifying action with ONLY de-humidifier relay
By setting the parameter tHu = db the de-humidifying action is performed by enabling the de-humidifier relay when the humidity is higher than SET
%RH + dbH.
The relay is switch off when humidity comes back to the SET %RH value.
4.3.2 Dehumidifying action with de-humidifier and compressor relays
By setting the parameter tHu = cHu the de-humidifying action is performed by enabling the de-humidifier and compressor relays together. when the
humidity is higher than SET %RH + dbH. The relays are switched off when humidity comes back to the SET %RH value.
If is simultaneously present a request of cooling (temp>SET TEM +dbt) and dehumidifying (RH > SET %RH+dbH): the cooling action has the priority
over the dehumidifying action: only the compressor relay is energised till the SET TEM is reached at this point also the de-humidifier is enabled.
5. FA NS
The fan control mode is selected by means of the “FnC” parameter:
FnC=C-n fans will switch ON and OFF with the compressor and not run during defrost:;
FnC= O-n fans will run continuously, but not during defrost
FnC=C-y fans will switch ON and OFF with the compressor and run during defrost;
FnC=O-y fans will run continuously also during defrost
6. EXT ACTO FAN
6.1 EXT ACTO FAN CYCLES
The second relay is configured as extractor fan, oA2= ESt, then it is possible to make extraction cycles, both manually and automatically.
Extraction cycle can be activated both manually by pushing the U key for 3s, and automatically by the internal time rFi. Cycle duration is set by the
rFd parameter. The cycle can be stopped also by key.
If rFI = 0 only manual cycle can be activated.
If rFd = 0 the cycle is stopped only by pushing the key.
7. MATU ING CYCLE WITH D IPPING, UNNING AND STOPPING PHASE.
Dripping Running Stopping
Running
Stopping

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 5/16
The diagrams displays a typical maturing cycle with the starting dripping phase.
D IPPING PHASE lasts for the “dri” time, without humidity control, temperature set is SETG
UNNING PHASE lasts for the “on” time, both temperature and humidity are controlled.
STOPPING PHASE lasts for the “off” time, without any control of temperature and humidity.
The end of the stopping phase is signalled by the internal buzzer and by the “End” message on the display.
After the STOPPING PHASE the behaviour of the controller depends on the parameter trc, according to the following settings:
trc = co controller maintains the set points of the running phase
trc = in controller stop the regulation at all.
trc = cL controller performs the running and stopping phase till is stopped manually.
trc = cLE as (trc = cL) plus at the end of each cycle the End label is displayed and the buzzer is switched on.
7.1 HOW TO SET THE DU ATION OF THE D IPPING, UNNING AND STOPPING PHASES
1. ush the CLOCK key, the display shows on the bottom display the “dri” message, while the “hourglass” start flashing.
2. ush again the CLOCK the duration of the dipping phase is shown, hh:mm.
3. To set the duration push the UP and DOWN keys.
4. ush again the CLOCK to confirm the time and pass to the setting of the running phase: the “on” message is displayed.
5. ush the CLOCK key to see its duration and use the UP and DOWN keys to set it.
6. ush again the CLOCK to confirm the time and pass to the setting of the stopping phase: the “oFF” message is displayed.
7. ush the CLOCK key to see its duration and use the UP and DOWN keys to set it.
8. Confirm the value by pushing again the CLOCK key and pass to the humidity display.
7.2 HOW TO SET THE TA GET HUMIDITY OF THE UNNING CYCLE
1. ush the SET % H key, the display shows on the bottom display the “SH1” message, while the “set” icon starts flashing.
2. ush again the SET % H the humidity set point of the running phase is shown. Set it using the UP and DOWN keys. To disable the humidity
control during the freezing phase set it to “nu”.
3. ush again the SET % H to confirm the value and pass to the humidity display.
7.3 HOW TO SET THE TA GET TEMPE ATU E OF THE D IPPING AND UNNING PHASES
1. ush the SET TEMP key, the display shows on the upper display the “StG” message, while the “set ” icon starts flashing.
2. ush again the SET TEMP the temperature set point of the running phase is shown. Set it using the UP and DOWN keys.
3. ush again the SET TEMP to confirm the value and pass to the setting of the dripping phase: the “St1” message is displayed.
4. ush the SET TEMP key to see its value and use the UP and DOWN keys to set it.
7.4 HOW TO STA T THE CYCLE
ush and release STA T key: the led will be turned ON.
The led flashes during the proving phase
7.5 END OF THE CYCLE
When the timer has expired, the buzzer starts sounding and the bottom display shows the “End” message.
To mute the buzzer push a key: The display come back to show the humidity and the LED of the START key is turned off.
7.6 HOW TO STOP THE CYCLE MANUALLY
To stop the cycle manually push the ON/OFF key .
7.7 HOW TO MODIFY THE SETTING OF THE CU ENT CYCLE WHILE IT’S UNNING
To modify the setting of the running cycle temperature (SET TEM ), humidity (SET %RH) or remaining time (CLOCK):
1. ush twice the corespondent key: the setting value of the current phase (dripping or running) will be displayed.
2. Modify it using the UP and DOWN keys
3. Confirm the value using the corespondent key: temperature (SET TEM ), humidity (SET %RH) or remaining time (CLOCK).
NOTE: the changes made will be memorised. So the next cycle will start with the new values.

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 6/16
8. THE DISPLAY
C
F
SET SET
%RH
To display and modify target temperature set point. (SET TEMP) for the running (St1)and
the dripping (StG) phase.
To display and modify target humidity set point (SET % H) of the running (SH1) phase; in
programming mode it selects a parameter or confirm an operation.
In programming mode it browses the parameter codes or increases the displayed value.
If oA2=ESt hold it pressed for 3s to start a extraction cycle
To start a manual defrost: hold it pressed for at least 3s.
In programming mode it browses the parameter codes or decreases the displayed value.
Switch ON and OFF the light, if present (oA1=lig)
Start: to start the cycle
Clock: to set the duration of the dripping (dri), running (on) and stopping (off) phases
Switch ON and OFF the instrument.
KEY COMBINATIONS
+
To lock and unlock the keyboard
+
To enter the programming mode.
+ To exit the programming mode.
8.1 ICONS AND SYMBOLS
Each LED function is described in the following table.
LED MODE FUNCTION
ON - Instrument in stand by.
- In “ r2” indicates that the parameter is also present in “ r1”.
°C ON °C

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 7/16
LED MODE FUNCTION
°C FLASHING If measurement unit is °C, it flashing on programming mode
°F ON °F
°F FLASHING If measurement unit is °F, it flashing on programming mode
ON The compressor is running
FLASHING - Anti-short cycle delay enabled
ON The defrost is enabled
ON Heating enabled
FLASHING Temperature Set programming phase
ON - ALARM signal
ON Fan is running
ON RH%
ON Dehumidifying enabled
ON Humidifying enabled
(umid) FLASHING Humidity Set programming phase
ON Running phase is in progress
FLASHING Dripping or stopping phase is in progress
FLASHING Setting of the duration of the cycle
8.2 HOW TO SEE AND MODIFY THE SET POINT (TEMPE ATU E AND HUMIDITY)
Or
1. ush and immediately release the SET key: the display will show the Set point
valueand the correspondant set icon starts flashing;
2. To change the Set value push the o
o o
o or n
nn
n arrows within 10s.
3. To memorise the new set point value push the SET key again or wait 10s.
8.3 TO STA T A MANUAL DEF OST
1. ush the DEF key for more than 2 seconds and a manual defrost will start.
8.4 TO STA T A EXT ACTION CYCLE MANUALLY
Hold pushed the U key for more than 2 sec.
To stop manually the cycle: when the cycle is running, hold pushed the U key for more
than 2 sec.
8.5 TO ENTE IN PA AMETE S LIST “P 1”
To enter the parameter list “ r1” (user accessible parameters) operate as follows:
+
1. Enter the rogramming mode by pressing the SET % H+ n
n n
n for few
seconds. (°C or °F start flashing)
2. The instrument will show the first parameter present in “ r1”
8.6 TO ENTE IN PA AMETE S LIST “P 2”
To access parameters in “Pr2”:
1. Enter the “ r1” level.
2. Select “ r2” parameter and press the “ SET % H ” key.
3. The “ AS” flashing message is displayed, shortly followed by “0 - -” with a flashing zero.
4. Use o
oo
o or n
nn
n to input the security code in the flashing digit; confirm the figure by pressing “ SET % H ”.
The security code is “321“.
5. If the security code is correct the access to “ r2” is enabled by pressing “ SET % H ” on the last digit.
Another possibility is the following: after switching ON the instrument the user can push SET % H + n
nn
n keys within 30 seconds.

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 8/16
NOTE: each parameter in “ r2” can be removed or put into “ r1” (user level) by pressing SET % H + n
nn
n. When a parameter is present in “ r1”
icon is on.
8.7 TO CHANGE PA AMETE VALUES
1. Enter the rogramming mode.
2. Select the required parameter with o
oo
o or n
nn
n.
3. ress the “ SET % H ” key to display its value (°C or °F icon start blinking).
4. Use o
oo
o or n
nn
n to change its value.
5. ress “ SET % H ” to store the new value and move to the following parameter.
To exit: ress SET % H + UP or wait 15s without pressing a key.
NOTE: the new programming is stored even when the procedure is exited by waiting the time-out.
8.8 HOW TO LOCK THE KEYBOA D
1. Keep the o
oo
o and n
nn
n keys pressed together for more than 3 s the o
oo
o and n
nn
n keys.
2. The “POF” message will be displayed and the keyboard is locked. At this point it is
only possible the viewing of the set point or the MAX o Min temperature stored and
to switch ON and OFF the light, the auxiliary output and the instrument.
TO UNLOCK THE KEYBOA D
Keep the o
oo
o and n
nn
n keys pressed together for more than 3s.
8.9 ON/OFF FUNCTION
By pushing the ON/OFF key, the instrument shows “OFF” for 5 sec. and the ON/OFF LED
is switched ON.
During the OFF status, all the relays are switched OFF and the regulations are stopped;
N.B. During the OFF status the icon is lighted.
9. PA AMETE LIST
EGULATION
dbt half dead band width for temperature: (0,1÷25,5°C; 1÷45°F) this band is place below and above the temperature set point (SET TEM ).
The compressor is enabled when the temperature increases and reaches the SET TEM + dbt value. It is turned off when it comes back to
the SET TEM . The heating output is enabled when temperature is less than SET TEM -dbt value and disabled when the SET TEM is
reached.
dbH half dead band width for humidity: (0,5÷25,5RH) this band is place below and above the humidity set point (SET %RH). The
dehumidifying action is enabled when the humidity increases and reaches the SET %RH + dbH value. It is stopped when it comes back to
the SET %RH. The humidifying output is enabled when humidity is less than SET %RH -dbH value and disabled when the SET %RH is
reached.
LS Minimum temperature set point limit: (-50,0°C÷
÷÷
÷SET; -58°F÷SET) Sets the minimum acceptable value for the set point.
US Maximum temperature set point limit: (SET÷
÷÷
÷110°C; SET÷230°F) Set the maximum acceptable value for set point.
OdS Outputs activation delay at start up: (0÷255 min) This function is enabled at the initial start up of the instrument and inhibits any output
activation for the period of time set in the parameter. (Light can work)
AC Anti-short cycle delay: (0÷30 min) interval between the compressor stop and the following restart.
tHu Kind of de-humidifying: db: only with de-humidifier relay (oA1= dEH); cHu with de-humidifier and compressor relay (oA1= dEH); c-H:
without de-humidifier relay, by means of compressor and heating relays (oA1≠ dEH).
LSH Minimum humidity set point limit: (Lci ÷ Set H) Sets the minimum acceptable value for the humidity set point.
uSH Maximum humidity set point limit: (Set H ÷ uci) Set the maximum acceptable value for humidity set point.
DISPLAY AND KIND OF EGULATION
CF Measurement unit: °C= Celsius; °F= Fahrenheit
rES esolution (for °C): allows decimal point display. dE = 0,1°C; in = 1 °C
rEH esolution for H%: in = integer; Hd= half digit.
trC Kind of behaviour after the end of the cycle
trC=co the controller goes on working, and maintains the temperature and humidity of the running phase, till the controller is stopped.
trC=in at the end of the stopping phase the controller gives the “End” message, the buzzer is turned on, and the regulation is stopped.
trC=cL at the end of the stopping phase the controller gives the “End” message, the buzzer is turned on, and the regulation restarts from the
running phase
trC=cLE at the end of the stopping phase the regulation restarts from the running phase.
DEF OST

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 9/16
tdF Defrost type: rE = electrical heater (Compressor OFF); in = hot gas (Compressor and defrost relays ON)
EdF Defrost mode: in = interval mode. The defrost starts when the time “Idf” is expired; Sd=Smartfrost mode. The IdF time (interval
between defrosts) is increased only when the compressor is running (even non consecutively).
SdF Set point for SMA TF OST: (-30÷30 °C/ -22÷86 °F) evaporator temperature which allows the IdF counting (interval between defrosts) in
SMARTFROST mode.
dtE Defrost termination temperature: (-50,0÷110,0°C; -58÷230°F) (Enabled only when the evaporator probe is present) sets the temperature
measured by the evaporator probe which causes the end of defrost.
IdF Interval between defrosts: (1÷120h) Determines the time interval between the beginning of two defrost cycles.
MdF Duration of defrost: (0÷255 min) When P2P = n, no evaporator probe, it sets the defrost duration, when P2P = y, defrost end based on
temperature, it sets the maximum length for defrost.
dFd Display during defrost: rt = real temperature; it = temperature reading at the defrost start;
Set set point; dEF = “dEF” label; dEG = “dEG” label;
dAd Defrost display time out: (0÷255 min) Sets the maximum time between the end of defrost and the restarting of the real room temperature
display.
Fdt Drain down time: (0÷60 min.) time interval between reaching defrost termination temperature and the restoring of the control’s normal
operation. This time allows the evaporator to eliminate water drops that might have formed due to defrost.
dPO First defrost after start-up: y = Immediately; n = after the IdF time
Hud Humidity control during defrost: no: the humidity control is stopped during the defrost; yES the humidity control works also during the
defrost.
FANS
FnC Fan operating mode: C-n = running when a load is on, OFF during the defrost; C-y = running when a load is on, ON during the defrost; O-n
= continuous mode, OFF during the defrost; O-y = continuous mode, ON during the defrost;
EXT ACTO FANS
rFi Interval between 2 cycles of change of air (0÷120 ore; 0 = only manual starting)
rFd Duration of change of air cycle (0÷250min; 0 = only manual stopping)
TEMPE ATU E ALA MS
ALC Temperature alarm configuration: rE = High and Low alarms related to Set oint; Ab = High and low alarms related to the absolute
temperature.
ALL Low temperature alarm setting: ALC = rE , 0 ÷
÷÷
÷ 50 °C or 90°F; ALC = Ab , - 50°C or -58°F ÷
÷÷
÷ ALU; when this temperature is reached
and after the ALd delay time, the LA alarm is enabled,.
ALU High temperature alarm setting: ALC= rE, 0 ÷
÷÷
÷ 50°C or 90°F; ALC= Ab, ALL ÷ 110°C or 230°F; when this temperature is reached and
after the ALd delay time the HA alarm is enabled.
ALH Temperature alarm recovery differential: (0,1÷25,5°C; 1÷45°F) Intervention differential for recovery of temperature alarm.
ALd Temperature alarm delay: (0÷255 min) time interval between the detection of an alarm condition and the corresponding alarm signalling.
dAO Delay of temperature alarm at start-up: (0min÷23h 50min) time interval between the detection of the temperature alarm condition after the
instrument power on and the alarm signalling.
EdA Alarm delay at the end of defrost: (0÷255 min) Time interval between the detection of the temperature alarm condition at the end of defrost
and the alarm signalling.
dot Delay of temperature alarm after closing the door : (0÷255 min) Time delay to signal the temperature alarm condition after closing the
door.
HUMIDITY ALA MS
AHC Humidity alarm configuration: rE = High and Low alarms related to humidity Set oint ; Ab= High and low alarms related to the “absolute”
humidity.
AHL Low humidity alarm setting: (with AHC = rE: 0 ÷ 50. With AHC = Ab: Lci ÷ AHu)
when this humidity is reached and after the AHd delay time, the HLA alarm is enabled,.
AHu High humidity alarm setting: (with AHC = rE: 0÷50°C. with AHC = Ab: AHL ÷ uci
when this humidity is reached and after the AHd delay time the HHA alarm is enabled.
AHH Humidity alarm recovery differential: (0.5÷20.0) Intervention differential for recovery of humidity alarm.
AHd Humidity alarm delay: (0÷255 min) time interval between the detection of an alarm condition and the corresponding alarm signalling.
dHo Delay of humidity alarm at start-up: (0min÷23h 50min) time interval between the detection of the humidity alarm condition after the
instrument power on and the alarm signalling.
doH Alarm delay at the end of defrost: (0÷255 min) Time interval between the detection of the humidity alarm condition at the end of defrost
and the alarm signalling.
doA Open door alarm delay:(0÷255 min) delay between the detection of the open door condition and its alarm signalling: the flashing message
“dA” is displayed.
tbA Alarm relay status after pushing a key: on= the relay remains on; off= the relay is switched off.
nPS Pressure switch number: (0 ÷15) Number of activation of the pressure switch, during the “did” interval, before signalling the alarm event
(I1F= AL). If the nPS activation in the “did” time is reached, switch off and on the instrument to restart normal regulation.
P OBE INPUTS
Ot Thermostat probe calibration: (-12.0÷
÷÷
÷12.0°C/ -21÷
÷÷
÷21°F) allows to adjust possible offset of the thermostat probe.

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 10/16
OE Evaporator probe calibration: (-12.0÷
÷÷
÷12.0°C/ -21÷
÷÷
÷21°F) allows to adjust possible offsets of the evaporator probe.
O3 Humidity probe calibration: (-10÷
÷÷
÷10 RH) allows to adjust possible offsets of the humidity probe.
P2P Evaporator probe presence: n= not present: the defrost stops only by time; y= present: the defrost stops by temperature and time.
P3P Humidity probe presence: n= not present; y= present.
LCI eadout with 4 mA : (-999 ÷ 999). Adjustment of read out corresponding to 4mA signal.
UCI eadout with 20 mA : (-999 ÷ 999). Adjustment of read out corresponding to 20mA signal.
DIGITAL INPUTS
i1P Configurable digital input polarity: CL : the digital input is activated by closing the contact; OP : the digital input is activated by
opening the contact;
i1P Door switch digital input polarity: CL : the digital input is activated by closing the contact; OP : the digital input is activated by opening
the contact
i1F Digital input operating mode: configure the digital input function: EAL = generic alarm; bAL = serious alarm mode; PAL = ressure
switch; Ht = heating relay safety; dor = door switch
odc Outputs status when open door: on = normal; Fan = Fan OFF; oFF = all the loads off
rrd Outputs restarting after doA alarm: no = outputs not affected by the doA alarm; yES = outputs restart with the doA alarm;
did Time interval/delay for digital input alarm:(0÷255 min.) Time interval to calculate the number of the pressure switch activation when
I1F= AL. If I1F=EAL or bAL (external alarms), “did” parameter defines the time delay between the detection and the successive signalling of
alarms.
OTHE
oA1 Light relay configuration: ALr = alarm; dEH = dehumidifier; onF = on/off relay: close with instrument on, open with instrument off; Lig =
light, ESt, dEF not select
oA2 Configuration of the defrost / extractor fans relay dEH = not select; onF = on/off relay: close with instrument on; open with instrument
on; Lig =Light , ESt = extractor fan; dEF = defrost relay.
Adt S485 serial address for temperature loads (0÷247) identifies the instrument within a control or supervising system.
AdH S485 serial address for humidity loads (0÷247) identifies the instrument within a control or supervising system.
Ptb Parameter table: (read only) it shows the original code of the dIXEL parameter map.
rEL Software release: (read only) Software version of the microprocessor.
Prd Probes display: (read only) display the temperature values of the evaporator probe b2.
Pr2 Access to the protected parameter list (read only).
10. DIGITAL INPUT
One digital input is present configurable by user by means of the i1F parameter according to the following descriptions.
10.1 DOO SWITCH (I1F = dor)
It signals the door status and the corresponding relay output status through the “odc” parameter: no = normal (any change); Fan = Fan OFF; oFF =
all the loads are switched off.
Since the door is opened, after the delay time set through parameter “dOA”, the alarm output is enabled and the display shows the message “dA”.
The status of loads depends on the “rrd” parameter:
with rrd=no outputs are not affected by the doA alarm;
with rrd=yES = outputs restart with the doA alarm;
The alarm stops as soon as the external digital input is disabled again. During this time and then for the delay “dot” and “doH” after closing the door,
the temperature and humidity alarms are disabled.
10.2 GENE IC ALA M (I1F = EAL)
As soon as the digital input is activated the unit will wait for “did” time delay before signalling the “EAL” alarm message. The outputs status don’t
change. The alarm stops just after the digital input is de-activated.
10.3 SE IOUS ALA M MODE (I1F = BAL)
When the digital input is activated, the unit will wait for “did” delay before signalling the “bAL” alarm message. The relay outputs are switched OFF.
The alarm will stop as soon as the digital input is de-activated.
10.4 P ESSU E SWITCH (I1F = PAL)
If during the interval time set by “did” parameter, the pressure switch has reached the number of activation of the “nPS” parameter, the “PAL”
pressure alarm message will be displayed. The compressor and the regulation are stopped. When the digital input is ON the compressor is always
OFF.
If the nPS activation in the did time is reached, switch off and on the instrument to restart normal regulation.
10.5 HEATING ELAY SAFETY (i1F=Ht)
With i1F=Ht as soon as the digital input is activated for “did” time heating relay is disabled.
The alarm will stop as soon as the digital input is de-activated.

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 11/16
10.6 DIGITAL INPUTS POLA ITY
The digital input polarity depends on the “i1P” parameters. CL : the digital input is activated by closing the contact; OP : the digital input is activated
by opening the contact
11. INSTALLATION AND MOUNTING
The temperature range allowed for correct operation is 0 - 60 °C. Avoid places subject to strong vibrations, corrosive gases, excessive dirt or
humidity. The same recommendations apply to probes. Let the air circulate by the cooling holes.
Thanks to the case XLH360. See the following instructions for details.
A B
C
D
E
G
F
FIG. 1
A
B
C
G
F
D
FIG. 2
87
230
MAX 37
210
130
120
M
A
X
2
8
H
I
FIG. 3

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 12/16
A
Fig. 6
2
0
0
6
1
0
0
172
106.44°
190
18
Fig. 4
2
0
0
1
9
2
.
5
1
8
5
61
12
6
0
0
4
11
14.5
22.5
29.5
160.55
167.5
175.5
179
186
190
R
5
8.5
8
.
5
1
0
6
.
4
4
°
R
5
Fig. 5
11.1 WALL MOUNTING
1. Unscrew the 4 frontal screws (Fig. 1, A, B, F, G) and remove the cover (Fig. 1, C).
2. Unscrew the 2 screws (Fig. 1, D, E) that keep connected the frontal and lower parts of Cool Mate and separate the 2 parts.
3. Make the proper holes for cablepresses or pipepresses using the centres signed in the bottom cover of the Cool Mate, (Fig. 3, H, I, ). Then
make 3 holes in the wall, as indicated in (Fig. 3, L, M, N), to fix the Cool Mate
4. Fix the cablepresses and the pipepresses..
5. Insert the wall-nugs, contained in the kit, into the holes made in the wall. Then use the o-rings and fix the back part of the Cool Mate (Fig. 3, L,
M, N) by means of the 3 screws to the wall itself.
6. Insert the wiring cables in cablepresses or in the pipepresses.
7. Mount the frontal part using the previous 4 screws Fig. 1, D, E, F, G. (do not press excessively in order to avoid plastic deformation).
8. After connecting the wires to the terminal blocks close the cover (Fig. 2, c) and fix it by the screws.

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 13/16
11.2 PANEL MOUNTING
1. Make a hole in the panel with dimensions described in Fig. 4 (simplified) or Fig. 5 (completed)
2. Unscrew the 4 frontal screws (Fig. 1, A, B, F, G) and remove the cover (Fig. 1, C).
3. Unscrew the 2 screws (Fig. 1, D, E) that keep connected the frontal and lower parts of Cool Mate and separate the 2 parts.
4. Cut from the back part of the Cool Mate the teeth indicated in Fig. 6, A.
5. Make the proper holes for cablepresses or pipepresses using the centres signed in the bottom cover of the Cool Mate, (Fig. 3, H, I, ).
6. Fix the cablepresses and the pipepresses..
7. Insert the wiring cables in cablepresses or in the pipepresses.
8. Join the back and frontal parts, with the panel in the middle, and fix them screwing the 4 screws taken previously away (dimensions 4x35
mm), in the holes of Fig. 1, A, B, D, E. Maximum panel thickness: 6mm.
9. After connecting the wires to the terminal blocks close the cover (Fig. 2, c) and fix it by the screws.
12. DIMENSIONS
210
87
2
3
0
13. ELECT ICAL CONNECTIONS
The instruments are provided with screw terminal block to connect cables with a cross section up to 2,5 mm2. Heat-resistant cables have to be used.
Before connecting cables make sure the power supply complies with the instrument’s requirements. Separate the probe cables from the power
supply cables, from the outputs and the power connections. Do not exceed the maximum current allowed on each relay, in case of heavier loads use
a suitable external relay.
13.1 P OBE CONNECTIONS
The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid infiltration. It is recommended to place the thermostat
probe away from air streams to correctly measure the average room temperature.
14. HOW TO USE THE HOT KEY
14.1 HOW TO P OG AM A HOT KEY F OM THE INST UMENT (UPLOAD)
1. rogram one controller with the front keypad.
2. When the controller is ON, insert the “Hot key” and push o
oo
o key; the "uPL" message appears followed a by flashing “End”
3. ush “SET” key and the End will stop flashing.
4. Turn OFF the instrument remove the “Hot Key”, then turn it ON again.
NOTE: the “Err” message is displayed for failed programming. In this case push again o
oo
o key if you want to restart the upload again or remove the
“Hot key” to abort the operation.
14.2 HOW TO P OG AM AN INST UMENT USING A HOT KEY (DOWNLOAD)
1. Turn OFF the instrument.
2. Insert a programmed “Hot Key” into the 5 PIN receptacle and then turn the Controller ON.
3. Automatically the parameter list of the “Hot Key” is downloaded into the Controller memory, the “doL” message is blinking followed a by
flashing “End”.
4. After 10 seconds the instrument will restart working with the new parameters.
5. Remove the “Hot Key”..

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 14/16
NOTE the message “Err” is displayed for failed programming. In this case turn the unit off and then on if you want to restart the download again or
remove the “Hot key” to abort the operation.
15. ALA M SIGNALLING
Message
Cause Outputs
“ 1” Thermostat probe failure Compressor and heating outputs off
“ 2” Evaporator probe failure Defrost and by time
“ 3” Humidity probe failure Humidity regulation off
“HA” High temperature alarm Outputs unchanged
“LA” Low temperature alarm Outputs unchanged
“HHA” High humidity alarm Outputs unchanged
“HLA” Low humidity alarm Outputs unchanged
“dA” Door switch alarm Outputs depending on the odC parameter
“EAL” External alarm Other outputs unchanged
“BAL” Serious external alarm Outputs OFF
“ AL” ressure switch alarm Outputs OFF
The alarm message is displayed until the alarm condition recoveries.
All the alarm messages are showed alternating with the room temperature except for the “P1” which is flashing. To reset the “EE” alarm and restart
the normal functioning press any key, the “rSt” message is displayed for about 3s.
15.1 SILENCING BUZZE
Once the alarm signal is detected the buzzer, if present, can be silenced by pressing any key.
15.2 ALA M ECOVE Y
Probe alarms : “P1” (probe1 faulty), “P2”, “P3”; they automatically stop 10s after the probe restarts normal operation. Check connections before
replacing the probe.
Temperature alarms “HA” and “LA” automatically stop as soon as the thermostat temperature returns to normal values or when the defrost starts.
Humidity alarms “HHA” and “LHA” automatically stop as soon as the humidity returns to normal values.
Door switch alarm “dA” stop as soon as the door is closed.
External alarms “EAL”, “BAL” stop as soon as the external digital input is disabled
Pressure switch alarm “PAL” alarm is recovered by switching OFF the instrument.
10. TECHNICAL DATA
Housing: self extinguishing ABS; Case: frontal 210x230 mm; depth 87mm; Mounting: See par. 11; Protection: I 65
Connections: Screw terminal block ≤ 2,5 mm2 wiring.
Power supply: 230Vac 50/60Hz ± 10% or 110Vac 50/60Hz ± 10%; Power absorption: 10VA max.
Display:3 digits, red LED, 30.5 mm high. 3 digits, yellow LED low.
Inputs: 2 NTC, 1 input 4 ÷ 20mA;
Digital inputs : Door switch and configurable, free voltage. Max. distance 10m;
elay outputs:
compressor: relay S ST 20(8) A, 250Vac;
defrost or extraction fans: relay S DT 16(3) A, 250Vac
fans: relay S ST 8(3) A, 250Vac;
heater control: relay S DT 20 A, 250Vac;
Humidifying: relay S ST 8 A, 250Vac
Light / De- humidifying: relay S ST 16 A, 250Vac
Other output :
Alarm buzzer (Standard)
Direct S485 (optional)
Serial output : TTL standard
Communication protocol: Modbus - RTU
Data storing: on the non-volatile memory (EE ROM).
Internal clock back-up: 24 hours
Kind of action: 1B; Pollution grade: normal; Software class: A.
Operating temperature: 0÷60 °C.
Storage temperature: -25÷60 °C.
elative humidity: 20÷85% (no condensing)
Measuring and regulation range: NTC probe: -40÷110°C (-58÷230°F)
esolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 15/16
16. XLH360 WI ING CONNECTIONS
1 2 3 4 5 6 7 8 9 101 1 12 13 14 151 6 17 18 19 20 21 222 3 24 2526 2728 29 30 31 33 34
Conf. Do or
Room
Evap.
HO T KEY
16A
250V~16A
250V~8 A
250V~
20A 250V
16 FLA(96L RA)
20A 250V
16FLA(96L RA)
8A
250V~
Supply
120/230V~
NLine
NC
Fa n
35 36
In
12V§gnd
Input
4÷20mA
NC
Def
Extr.
Hea ter Hum
L ight D e-
Hum
Comp
RS 48 5
110 Vac Power Supply: connect to 33-34 terminals
17. DEFAULT SETTING VALUES
Set temperature Set humidity Duration
Dripping hase 5.0 °C - - 5.00 h
Running hase 5.0 °C 50.0 RH% 5.00 h
Stopping hase - - 5.00 h
Label Value Menu Description ange
dbt 2.0 Pr1 Half dead band width for temperature 0.1°C o 1°F ÷ 25°C o 77°F
dbH 5.0 Pr1 Half dead band width for humidity 0.5 ÷ 50
LS -40.0 Pr2 Minimum temperature set point limit -50.0°C o –58°F ÷ Set T
uS 110 Pr2 Maximum temperature set point limit Set T ÷ 110°C o 230°F
odS 1 Pr2 Outputs activation delay at start up 0 ÷ 250 min
Ac 1 Pr1 Anti-short cycle delay 0 ÷ 30 min
tHu c-H Pr2 Humidity regulation db = dehumidifier relay.; cHu = dehum+
compr.; c-H= without dehum. relay
LSH 0.0 Pr2 Minimum humidity set point limit Lci ÷ Set H
uSH 100 Pr2 Maximum humidity set point limit Set H ÷ uci
cF °C Pr2 Measurement unit °C ÷°F
rES dE Pr2 Resolution (for °C): in = integer / dE = decimal
rEH Hd Pr2 Resolution for RH%: in = integer / Hd = half digit
trC co Pr2 Instrument behaviour at the end of the cycle
co=start holding, in=stop regulation,
cL=restart the first phase+End message; cLE
= restart the first phase
tdF rE Pr2 Defrost type rE, rT, in
EdF in Pr2 Defrost mode In, Sd
SdF 0.0 Pr2 Set point for SMART DEFROST -30 ÷ +30°C / -22÷+86°F
dtE 8.0 Pr2 Defrost termination temperature -50,0÷110°C/ -58÷230°F
idF 6 Pr1 Interval between defrosts 1 ÷ 120 h
MdF 20 Pr1 Duration of defrost 0 ÷ 250 min
dFd it Pr2 Display during defrost rt / it / SEt / dEF / dEG
dAd 30 Pr2 Defrost display time out 0 ÷ 250 min
Fdt 0 Pr2 Draining time 0÷60 min.
dPo no Pr2 First defrost after start up n ÷ y
Hud no Pr2 Humidity control during defrost no; yES
Fnc c-n Pr2 Fan operating mode c-n / c-Y / o-n / o-Y
rFi 0 Pr2 Interval between 2 cycles of change of air 1 ÷ 120 h (0 = manual start)
rFd 0 Pr2 Duration of cycle of change of air 1 ÷ 250 min (0 = manual stop)
ALc Ab Pr2 Temperature alarm configuration rE = relative / Ab = absolute
ALL -40.0 Pr1 Low temperature alarm setting 0°C ÷ 50.0°C / -50.0°C ÷ ALu
ALu 110 Pr1 High temperature alarm setting 0°C ÷ 50.0°C / ALL ÷ 110°C
ALH 1.0 Pr2 Temperature alarm recovery differential 0.1°C o 1°F ÷ 25°C o 77°F
ALd 15 Pr2 Temperature alarm delay 0 ÷ 250 min
dAo 1.3 Pr2 Delay of temperature alarm at start-up 0.0 ÷ 23.5 h
EdA 20 Pr2 Alarm delay at the end of defrost 0 ÷ 250 min

dIXEL
dIXELdIXEL
dIXEL
Operating Instructions cod.
cod. cod.
cod. 1592017410
15920174101592017410
1592017410
1592017410 XLH360 GB r1.0 15.04.2005.doc XLH360 16/16
Label Value Menu Description ange
dot 20 Pr2 Delay of temperature alarm after closing the door 0 ÷ 250 min
AHc Ab Pr2 Humidity alarm configuration rE = relative / Ab = absolute
AHL 0.0 Pr1 Low humidity alarm setting 0 ÷ 50 / Lci ÷ AHu
AHu 100 Pr1 High humidity alarm setting 0 ÷ 50 / AHL ÷ uci
AHH 2.0 Pr2 Humidity alarm recovery differential 0.5 ÷ 25
AHd 15 Pr2 Humidity alarm delay 0 ÷ 250 min
dHo 1.3 Pr2 Delay of humidity alarm at start-up 0.0 ÷ 23.5 h
doH 20 Pr2 Alarm delay at the end of defrost 0 ÷ 250 min
doA 20 Pr2 Open door alarm delay 0 ÷ 250 min ( 250 = nu )
tbA oFF Pr2 Relay status after pushing a key on÷oFF
nPS 15 Pr2 ressure switch number 0÷15
ot 0.0 Pr1 Thermostat probe calibration -12.0 ÷ 12.0
oE 0.0 Pr2 Evaporator probe calibration -12.0 ÷ 12.0
o3 0.0 Pr1 Humidity probe calibration -10 ÷ 10
P2P YES Pr2 Evaporator probe presence no = absent / YES = present
P3P YES Pr2 Humidity probe presence no = absent / YES = present
Lci 0.0 Pr2 Readout with 4 mA -999 ÷ 999
uci 100 Pr2 Readout with 20 mA -999 ÷ 999
i1P cL Pr2 Configurable digital input polarity cL =open / o = close
i2P cL Pr2 Door switch digital input polarity cL =open / o = close
i1F dor Pr2 Digital input configuration dor / AL / EAL / bAL / Ht
odc FAn Pr2 Outputs status when open door on / Fan / oFF
rrd YES Pr2 Outputs restarting after doA alarm no = no / YES = yes
did 0 Pr2 Digital input alarm delay 0÷255 min.
oA1 LiG Pr2 Light relay configuration 1 ALr = alarm; dEH = dehumidifier; onF =
on/off; Lig = light, ESt, dEF not select
oA2 ESt Pr2 Light relay configuration 2 ALr = alarm; dEH = not use; onF = on/off; Lig
= light, ESt= extractor, dEF =defrost
Adt 1 r2 Serial address for temperature 0÷247 num
AdH 1 r2 Serial address for humidity 0÷247 num
Ptb - - - r2 arameter table - - -
rEL - - - r2 Software release - - -
Prd - - - r2 robes display b1÷ b3
Pr2 - - - r1 Access to the protected parameter list - - -
This manual suits for next models
1