Carbon Monoxide Detector Manual
First Equipment Characteristics:
The detector adopt natural spreading method to detect the gas, sensitivity elements adopt
high sensitivity electric chemical sensor, it has the characteristics like high sensitivity, long
working life, low power consumption and excellent repetitiveness, convenient to use and
maintain, extremely meeting the requirements of industry field safety monitor to
reliability of equipment.
Second Technical Index:
CO detection range: 0-1000PPM
CO Low Alarm: 50
CO High Alarm: 150
Resolution: 1PPM
Displays error (different according to installed sensor):
±5PPM or ±10% of reading,
Working environment:
Temperature: -20℃~50℃; humidity: <95%RH(no condensation)
Indicating method: displays real time data, LED, sound, indication alarm, failure and lack
voltage
Response time: T<30s
Supply power: CR2 3V
Explode proof marks: Ex ib IIB T3 Gb
Explode proof certificate number: CNEX18.0175X
Size: 65*65*21mm
Weight: 60g
Third Operating Methods:
(1) Enter into menu: press middle button to enter into main menu interface.
Function
Instruction
F—1
Zero Point Setting
F—2
Gas Calibration Setting
F—3
Level I Alarm Value Setting
F—4
Level II Alarm Value Setting
F—5
Save Setting
F—6
Restore Setting
F—7
User Calibration
(2) Button performance: Press the “▲” button then number upward turn, Press the “▼”
button then number downward turn. Long-press the “▼” button, then number increase
one-digit, long-press the “▲” button, then number reduce one-digit. Press the “ ” button
then save the setting. Long-press the “ ” button then cancel the setting.
(3) The setting mode will return to the monitoring interface if there is no operation for 8
seconds.
1. F—1 Zero Point Setting (FOR INDUSTRIAL USE ONLY)
2. F—2 Gas Calibration Setting (FOR INDUSTRIAL USE ONLY)
3. F—3 Level I Alarm Value Setting (CO Low Alarm Setting)
Press the “ ” button, the screen displays F—1. Press the “▲” button or “▼” button until
the screen shows F—3. Press the “ ” button; enter into the level I alarm value setting.
The screen displays the current level I alarm value. Press the “▲” or “▼”
button to reset the number if need modifies the value. Press the “▲” button
or “▼” button to process number selection. Pressing and holding on the “▼”
button, then it shows as two-digit numbers; long-press the “▲” button,
goes back to a one-digit number. Press the “ ” button to save the Level I
Alarm Value setting number after confirmed the modified value. The screen
displays SUCC and the device will beep twice. Long-press the “ ” button,
cancel the setting, and return to up one level menu.
4. F—4 Level II Alarm Value Setting (CO High Alarm Setting)
Press the “ ” button, the screen displays F—1. Press the “▲” button or “▼”
button until the screen shows F—4. Press the “ ” button; enter into the
level II alarm value setting. The screen displays the current level II alarm
value. Press the “▲” button or “▼” button to reset the number if need
modifies the value. Press the “▲” button or “▼” button to process number
selection. Pressing and holding on the “▼” button, then it shows as two-digit
numbers; long-press the “▲” button, goes back to a one-digit number.
Press the “ ” button to save the Level II Alarm Value setting number after
confirmed the modified value. The screen displays SUCC and the device will
beep twice. Long-press the “ ” button, cancel the setting, and return to up
one level menu.
5. F—5 Save Setting
Press the “ ” button, the screen displays F—1. Press the “▲” button or “▼”
button until the screen shows F—5. Press the “ ” button; enter into Saving
Setting interface. Occur 0 flashing after displays SUCC, need input
password. Press the “▲” button or “▼” button to process number selection.
Pressing and holding on the “▼” button, then it shows as two-digit numbers;
long-press the “▲” button, goes back to a one-digit number. Input password
and press the “ ” button, the screen displays SUCC and the device will
beep twice. The Save Setting is updated. Long-press the “ ” button, cancel
the setting, and return to up one level menu.
6. F—6 Restore Setting
Press the “ ” button, the screen displays F—1. Press the “▲” button or “▼”
button until the screen shows F—6. Press the “ ” button; enter into
Restore Setting interface. Press the “ ” button, the screen displays SUCC
and the device will beep twice, save Restore Setting successfully.
Long-press the “ ” button, cancel the setting, and return to up one level
menu.
Note:
(1) If you change the settings and NOT Save them in “F—5 Save Setting”,
then the device will restore the Factory Default Setting.
(2) If you change the settings and save them in “F—5 Save Setting”, then
the device will restore the latest saved value of Save Setting.
7. F—7 User Calibration
A user may perform a user calibration when the CO reading is inconsistent with the actual
CO concentration.
Press the “ ” button, the screen displays F-1. Press the “▲” button or “▼” button until
the screen shows F—7. Press the “ ” button, enter into User Calibration. The screen
displays the current CO reading. Press the “ ” button after CO reading is stabled, input
correct CO concentration. Press the “▲” button or “▼” button to process number selection,
long-press the “▼” button, then number increase one-digit; long-press the “▲” button,
then number reduce one-digit. Press the “ ” button to save the Calibration setting
number after confirmed the modified value. The screen displays SUCC and the device will
beep twice. Long-press the “ ” button, cancel the setting and return to up one level
menu.
Fourth Common Failure:
1. Can’t start the device and should check whether batteries are normal, whether socket
sheets have oxidized appearance, or please contact the purchaser to seek help.
2. If the instrument no action then maybe the sensor is damaged or the electric circuit
damaged, please contact the distributor or manufacturer for repair.
3. Instrument sensitivity comes to below, maybe it has been high potency shocking, or
harmed by halogen, silicide, these caused sensor poisoning and damage. Need renewal
sensor.
Fifth Notices:
1. Prevent this device fallen from a high place or seriously vibrated. The instrument can’t
be soaked into the water during operation;
2. Maybe unable to normally use this device when existing high potency gas;
3. Please strictly follow the manual to operate and use, otherwise it may be caused
incorrect detect result or damage this device.
Maintain Guarantee Card
Product Name: Carbon Monoxide Detector
Product Model: CO-3
According to stipulates of the national
“New three guarantee”, the whole set
maintains a guarantee of one year (from
the day of purchase). Please safety keeps
this card to be as maintain guarantee
certificate.
Qualified Certificate
Product Name: Carbon Monoxide Detector
Product Model: CO-3
This product qualified after detected, in
accordance with the related stipulates,
approve to leave the factory.
DOEATOOW provides full after-sales service to all customers. If you have any questions or
concerns, please email us via [email protected] and we will answer you within 24
hours.
Carbon Monoxide Detector
(CO Alarm device)
Operation Manual

Popular Gas Detector manuals by other brands

Evikon PluraSens E2608 Series user manual

Evikon

Evikon PluraSens E2608 Series user manual

Tecnogas LINEASICURA CD98E quick start guide

Tecnogas

Tecnogas LINEASICURA CD98E quick start guide

BRUEL & KJAER 1306 instruction manual

BRUEL & KJAER

BRUEL & KJAER 1306 instruction manual

New Cosmos Electric NV-100C instruction manual

New Cosmos Electric

New Cosmos Electric NV-100C instruction manual

AVE Domusair RG1/CO2 quick start guide

AVE

AVE Domusair RG1/CO2 quick start guide

BEINAT CHECKER-24 instruction manual

BEINAT

BEINAT CHECKER-24 instruction manual

mumbi m-GM100 user manual

mumbi

mumbi m-GM100 user manual

STATUS SCIENTIFIC CONTROLS FGD10A Installation, Commissioning & Routine Gas Testing Manual

STATUS SCIENTIFIC CONTROLS

STATUS SCIENTIFIC CONTROLS FGD10A Installation, Commissioning & Routine Gas Testing Manual

S+S Regeltechnik AERASGARD AC02-SD-TYR2 Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik AERASGARD AC02-SD-TYR2 Operating Instructions, Mounting & Installation

Bühler technologies GAS 222.35 AMEX Brief instructions

Bühler technologies

Bühler technologies GAS 222.35 AMEX Brief instructions

S&S Northern Merlin GDP4 Installation operation & maintenance

S&S Northern

S&S Northern Merlin GDP4 Installation operation & maintenance

Sona WCOB-SN-1 Installation and user guide

Sona

Sona WCOB-SN-1 Installation and user guide

Danfoss GDA installation guide

Danfoss

Danfoss GDA installation guide

Herth+Buss ELPARTS SelectH2 mini operating instructions

Herth+Buss

Herth+Buss ELPARTS SelectH2 mini operating instructions

brennenstuhl BCN 1221 Directions for use

brennenstuhl

brennenstuhl BCN 1221 Directions for use

Accuro 64 00 000 Instructions for use

Accuro

Accuro 64 00 000 Instructions for use

Trolex Sentro 1 user manual

Trolex

Trolex Sentro 1 user manual

GASTRON GTD-2000Ex instruction manual

GASTRON

GASTRON GTD-2000Ex instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.