V E N T I L A T I O N
SVC100 Range
Shuttered Axial Wall/Window Fans
Installation Instructions
LAB538R (Issue 2) April 2018 Page 1
SVC 100 Range Window/Wall Fan
These high quality extractor fans are designed to give effective ventilation and in order to achieve this, please read these instructions
carefully BEFORE installing the fan unit. Failure to comply with these instructions could reduce the life of the product and may
invalidate the warranty.
This product is suitable for use with up to 1 metre of ducting.
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
WIRING INSTALLATION
FAN
WALL
GRILLE
FALL TO
OUTSIDE
CONDENSATION
TRAP
FAN
FAN
WALL
GRILLE
FALL TO
OUTSIDE
FITTING WALL FAN
1. Select a suitable position for the fan
in relation to outside walls, ceilings
and roofs, keeping the ducting as
short as possible – see Ducting.
2. Cut a hole in the wall or ceiling to
take rear spigot of fan plus ducting
if fitted.
3. Remove the front cover from the
fan by undoing the retaining screw
at the bottom edge of front cover.
Position the fan chassis and mark the
retaining screw positions.
4. Remove the appropriate cable
entry knock-out position from the
fan chassis and thread power cable
through before fixing the fan to the
wall.
Note:
Fans fitted with pull cord switches
are not suitable for ceiling mounting.
DUCTING
1. Bring the ducting to the chosen
locations and trim its ends flush to
the surfaces.
2. Note that there are 3 basic types of
installation and that condensation
drainage should be provided as
shown. Ceiling location makes
drainage provision essential.
3. A small condensation trap should
be made at the lowest point of the
ducting as shown, it is advisable to
lag ducting.
Note:
All the ancillary items can be
obtained through Domus stockists.
call +44 (0) 3443 715 523
to find your nearest stockists.
SVC100 RANGE
Standard
With Pull Cord
With Humidistat, Timer and Pull Cord
With Timer
With Humidistat and Timer
SVC100B
SVC100PB
SVC100HTBPC
SVC100TB
SVC100HTB
IF IN DOUBT, PLEASE CONSULT A QUALIFIED ELECTRICIAN
WARNING : ISOLATE ELECTRICITY
SUPPLY BEFORE STARTING WORK
DO NOT INSTALL IN SHOWER CUBICLES
Maximum Room Temperature 40ºC
It is recommended that the fans be connected into the lighting
circuit, with double pole (3mm) isolation provided before the
room light switch and suitably fused, in accordance with IEE
Regulations.
Window fans should be connected to power supply using a
flexible cord with conductors of between 0.75mm2 and 1.5mm2
only.
Wall and ceiling mounted fans for fixed wiring should be
connected to the power supply via a cable with solid conductors
of 1mm2 to 1.5mm2 only.
CAUTION: Fans incorporating electronic control systems
may be damaged if used in conjunction with
fluorescent lamps. If in doubt, we recommend
you contact Domus Ventilation customer
services on 03443 715 523
MODELS
SVC100TB
SVC100HTB
SVC100HTBPC
MODELS
SVC100B
MODELS
SVC100PB
To access terminals
on these models,
lift off control cover
S/L N L N L N L
S/L N L N L N L
Operating
Switch
Isolator
Switch
Isolator
Switch
L = LIVE N = NEUTRAL S/L = SWITCH LIVE
Operating
Switch
Isolator
Switch