Doorentryonline SR2-X User manual

SR2-X
Proximity, Wiegand & Mifare Card
Reader with Remote Control
User Manual

INTRODUCTION
The SR2-X is a compact, weather resistant multi-function card reader that can be used as a standalone
programmable access control card reader as well as a Wiegand output card reader providing proximity entry
for up to 1000 users, (987 common users, 2 panic users, 10 visitor users & 1 x Authorized user) PIN access is
also possible via the remote control unit for the Administrator and all user data can be transferred from one
unit to another within 3 minutes (Maximum connection is 9 units)
It reads both EM 125KHz & Mifare Classic 13.56MHz card or key fob. It uses Atmel micro controller to ensure
maximum performance in any environment, and the low-power circuit makes its service life prolonged
The SR2-X’s unique feature is simple in design, easy to operate/program, and high reliability
Features
Weather resistant to IP66
Reads 125KHz EM & 13.56MHz Mifare card or key fob
One programmable relay operation
Pulse mode, Latch mode relay operation
Remote infrared programmer
Master Add/Delete card
1000 users (987 common users, 2 panic users, 10 visitor users & 1 x Authorized user)
User data can be transferred from one unit to another
Wiegand 26-44 bit input & output
Card block enrolment
Tri-colour LED status display
Built in light dependent resistor (LDR) for anti tamper
Buzzer for audible or silent mode
Low temperature resistance (-40℃)
Specifications:
User Capacity
Card/key fob
1000
EM card and Mifare card
Operating Voltage
Idle Current
12-18V DC
<
35mA
Proximity Card Reader
Radio Technology
Read Range
EM & Mifare
125KHz & 13.56MHz
Proximity Card 2-6cm
Wiring Connections
Relay Output, Exit Button
Relay
Adjustable Relay Output Time
Lock Output Load
One (NO, NC, Common)
1-99 Seconds (5 seconds default)
2 Amp Maximum
Environment
Operating Temperature
Operating Humidity
Meets IP66
-40℃ - 60℃
20%RH-98%RH
Physical
Colour
Dimensions
Unit Weight
Shipping Weight
ABS Shell
Black
H:102 W:48 D:20mm
150g
250g

Package Contents
SR2-X Card Reader Infrared Remote Control
Master Add/Delete card & 10 x EM-RFID user cards or key
fobs
Diode IN4004 (For relay circuit protection)
Self Tapping Screws: 3*25mm
Wall Anchors
Screw Driver

INSTALLATION
Remove the back cover from the unit
Drill 2 holes (A,C) on the wall for the screws and one hole for the cable
Knock the supplied rubber bungs to the screw holes (A,C)
Fix the back cover firmly on the wall with 4 flat head screws
Thread the cable through the cable hole(B)
Attach the unit to the back cover
Wiring cable
Wire Insulation Colour
Function
Notes
Red
Power
12-18 Volts DC Power input
Black
GND
Ground
Blue
NO
Normally open relay output
Purple
COM
Common connection for relay output
Orange
NC
Normally closed relay output
Yellow
OPEN
Request to exit input (REX)
Green
Data 0
Wiegand output Data 0
White
Data 1
Wiegand output Data 1
Grey
Alarm output
Negative output for alarm
Brown
Contact input
Door/gate input (Normally closed)

Connection Diagram Examples
Common power supply for magnetic lock (Fail open – power to lock)
Common power supply for lock release (Fail secure – power to unlock)
Common power supply for auto gate controller (using Normally Open contact)

PROGRAMMING
Programming will vary depending on your access configuration. Please follow the instructions according to
your access configuration
General Programming Information – Two ways
1) Remote Control: Please use the Infrared Remote Control to program the Reader. The infrared
receiver head is near the LED, so when you program the reader, please direct the Remote Control to
the LED (Factory default code: *123456#)
User ID number: Assign a User ID to the access card/key fob in order to easily delete it via the remote
control in the event it becomes lost
The common user ID number can be any number from 0-986. IMPORTANT: User ID’s do not have to be
proceeded with any leading zeros, Recording of User ID’s is crucial. Modifications to the user requires
the User ID to be available
2) Master Add/Delete Card to add or delete any:
Proximity Card: 125KHz industry standard EM-RFID or 13.56MHz Mifare proximity card or key fob
Sound and Light indications
Operation Status
Led Colour
Buzzer
Stand by
Red light bright
-
Enter into programming mode Red light shines One bleep
In the programming mode
Orange light bright
One bleep
Operation error
-
Three bleeps
Exit from the programming mode
Red light bright
One bleep
Open lock
Green light bright
One bleep
Alarm **
Red light Shines quickly
Continual bleeps
** Please see Reset Procedure for ALARM (Page 12)
Easy way
Add cards/key fobs by using the Master Add/Delete Card
Programming Step
Action
1. Present the Master Add/Delete Card
once
Present the user card/key fob to be added
Re-present the Master Add/Delete Card to confirm
Delete cards by using the Master Add/Delete Card
Programming Step
Action
1. Present the Master Add/Delete Card
twice
Present the user card/key fob to be deleted
Present the Master Add/Delete Card to confirm

Connection to a 3rd party Wiegand controller or our PC access control system AC8001/2
Set Operation Mode – Stand-alone or
Wiegand (Default is stand-alone)
Programming Step
Remote Control Operation
1. Enter Program Mode
2. Stand-alone Operation
3. Wiegand Reader Operation
* (Master Code) #
77 # is factory default for stand-alone
78 #
4. Exit Program Mode
*
User data transfer connection (1 x power supply and 9 x SR2-X units)
Set User Data Transfer
Programming Step
Remote Control Operation
1. Enter Program Mode
2. Set Transfer Data on the first SR2-X
For all 1000 users, this will take 3 minutes
* (Master Code) #
98 #
Within 3 minutes the green LED will shine, after 1 x bleep
the LED will turn red to confirm data transfer
3. Exit Program Mode
*

Enter and Exit Program Mode Via the Remote Control
Programming Step
Remote Control Operation
1. Enter Program Mode * (Master Code) #
Factory default is 123456
2. Exit Program Mode
*
Set New Master Code Via the Remote Control
Programming Step
Remote Control Operation
1. Enter Program Mode
2. Enter New Master Code
* (Master Code) #
0 (New Master Code) # (Repeat new Master Code)
#
Must be a 6 digit number
3. Exit Program Mode
*

Add User Cards Via the Remote Control
Programming Step
Remote Control Operation
1. Enter Program Mode
* (Master Code) #
2. Add Card: Using Auto ID number
(Allows the SR2-X to assign Card to
next available User ID number)
OR
3. Add Card: Select Specific ID number
(Allows manager to define a specific User ID
to associate the card to)
OR
4. Add Card: by Card Number
OR
5. Add Card: Block Enrolment
(Allows the master card to add up to 986
cards in a single step – this takes 2-3
minutes)
1 (Present Card) #
Repeat Step 2 for additional user cards
1 (User ID) # (Present Card) #
The user ID is any number from 0-986
1 (Input the 8/10 digit Card number) #
1 (User ID) # (Card Quantity) # (The first card
number) #
Card or fob number MUST be consecutive
6. Exit Program Mode
*
Add User PIN Code via the Remote Control
Programming Step
Remote Control Operation
1. Enter Program Mode
* (Master Code) #
2. Add PIN: Via remote controller
OR
1 (Enter PIN number, 4-6 digits) #
3. Add PIN to define a specific User ID
number
1 (User ID) # (Enter PIN number, 4-6 digits) #
The user ID is any number from 0-986
4.
Exit Program Mode
*
Add Authorized User Via the Remote Control
Adding an Authorized User PIN code or user card will block all other users from access. Re-enter or
present the Authorized PIN code or card will re-allow user access. The USER ID number must be 987
for this function to operate
1. Enter Program Mode
* (Master Code) #
2. Add PIN: Via remote controller
OR
3. Add Card
1 (Enter User ID 987) # (Enter PIN number, 4-6
digits) #
1 (Enter User ID 987) # (Present Card) #
4. Exit Program Mode
*

Add Visitor Users via the Remote Control
Up to 10 Visitor Users can be added and allowed no more than ten times of usage until they are
automatically invalid. The USER ID numbers must be 990-999 for this function to operate
Programming Step
Remote Control Operation
1. Enter Program Mode
* (Master Code) #
2. Add PIN
OR
1 (User ID) # (0-9) # (Enter PIN number, 4-6 digits)
#
3. Add Card 1 (User ID) # (0-9) # (Present Card) #
The user ID numbers must be from 990-999
(0-9) Means the number of usage times – 0=10 times
4. Exit Program Mode
*
Delete User Cards or PIN code Via the Remote Control
Programming Step
Remote Control Operation
1. Enter Program Mode
* (Master Code) #
2. Delete Card/PIN: By read card
OR
3. Delete Card: By User ID
number
OR
4. Delete Card: By Card Number
OR
5. Delete all users
2 (Present Card/Or enter Pin code) #
Repeat step 2 for additional user cards before pressing the
#
2 (Enter user ID number) #
The user ID is any number from 0-986
2 (Input the 8/10 digits Card number) #
2 (Master Code) #
6. Exit Program Mode
*
Set Relay Configuration Via the Remote Control
The relay configuration sets the behavior of the output relay on activation
Programming Step
Remote Control Operation
1. Enter Program Mode
2. Pulse Mode
OR
3. Latch Mode
* (Master Code) #
3 (1-99) #
The relay time is 1-99 seconds. (1=50ms) Default is 5
seconds
30 # Sets the relay to ON/OFF Latch mode
4. Exit Program Mode
*

Set Strike-out Alarm
The strike-our alarm will sound after 10 failed card attempts (Default setting is OFF). It can be set to deny
access for 10 minutes after engaging or disengage only after entering a valid card/PIN or Master Code/Card
Programming Step
Remote Control Operation
1. Enter Program Mode
* (Master Code) #
2. Strike-Out OFF
OR
3. Strike-Out ON
OR
4. Strike-Out ON (Alarm) Set alarm time
60# (Factory default is OFF)
61# Access is denied for 10 minutes
62#, 5 (0-3) # (Factory default is 1 minute) Enter Master Code
# or
present the Master Card or enter valid user card/PIN to silence
5. Exit Program Mode
*
Set Audible and Visual Response Via the Remote Control
Programming Step
Remote Control Operation
1. Enter Program Mode
2. Control tone sounds
* (Master Code) #
OFF = 70 # ON = 71 #
OR
3. Control LED’s
OFF = 72 # ON = 73 #
(Factory default is ON)
4. Exit Program Mode
*
Reset Procedure
Reset Alarm:
The alarm will sound for 3 minutes. To reset, present a valid user card or enter * (Master Code) # via the
remote control
Reset to Factory Default:
To reset to factory default, power off, press the Exit Button or short circuit the Black (GND) and Yellow (Open)
wires, and then power on, there will be two bleeps, and the LED light will turn orange, keep this condition until
you hear a long bleep after 10 seconds. The LED will turn red to confirm factory default is successful
Note: Reset to factory default, the user’s card/key fob information is still retained
Reset to Factory Default to add a new Master Card:
To reset to factory default, power off, press the Exit Button, or short circuit the Black (GND) and Yellow (Open)
wires, and then power on, there will be two bleeps, and the LED light will turn orange
Release the exit button or the Black (GND) and Yellow (Open) wires, then present any 125KHz EM or 13.56MHz
card or key fob and the LED will turn red to confirm factory default is successful
Note: Reset to factory default, the user’s card/key fob information is still retained

The SR2-X’s alarm trigger is activated by an LDR (Light Dependent Resistor) which is located to the rear left
side of the unit as illustrated below
The alarm function is designed as an ‘Anti-Theft’ facility which cannot be disabled but it can be stopped by
presenting a valid card or key fob to the reader or entering the Master Code followed by the # sign via the
remote
Alternatively, you can prevent the alarm from activating by covering the LDR with a non-light absorbent
substance. Black paint or a small amount of ‘Blu-Tack’ will work perfectly fine
This is the LDR (Light
Dependent Resistor).
The LDR is the SR2’s
Alarm Trigger Sensor
and activated by light
Table of contents
Other Doorentryonline Card Reader manuals