Dover Hillphoenix Coolgenix Configuration guide

Coolgenix™ Case Cleaning Checklist
Pre-Cleaning Check List
Identify the cases that need to be cleaned (Note: Multiple cases usually run on the same
refrigeration circuit, so plan on cleaning all cases on that circuit at one time)
Post safety signs in the area of the cases that are going to be cleaned
Remove the product from the cases and relocate to a refrigerated storage area
Turn off the refrigeration to the cases, there are several options:
Turn off at the power supply
If your case is equipped with a clean switch button, push the button. The push button allows
for a 90 minute delay and will automatically turn back on after 90 minutes
If your case is equipped with a cleaning toggle switch, flip the manual toggle off to clean and
manually flip back on when case is cleaned
If you are unable to turn the refrigeration off to the case by the above methods, put the case
in a manual defrost through the Dixell Controller -
Push the DOWN key for more than 2 seconds and a manual defrost will start on
the Dixell Controller. The controller must be turned back on when finished
cleaning.
If your case is equipped by a different type of controller, refer to the controller manual for
putting the case into manual defrost for case cleaning
Turn off the electrical circuits to the case at the power supply
Wait until the Coolgenix deck pans are room temperature before removing - the center pan will
have a sensor attached on the bottom of the deck pan, detach the
sensor before removing the pan
Visually inspect the cases for debris and ice
Check the drain to make sure it is not clogged
Gather all necessary cleaning materials
Mild cleaning solution
Sanitizer
! !CAUTION
Do not perform these procedures until you have been properly trained by store personnel to clean
the cases or watched the Hillphoenix Case Cleaning Guidelines video. Make sure you follow safety
procedures outlined by your organization and abide by any state and local codes that may apply.
Location of pan sensor found on the
bottom of the center deck pan in the
display case.

Clean towels or paper towels
Soap and hot water (Cleaning tank only)
Non-abrasive cleaning pads
Glass cleaner
Case Cleaning Check List
1. Clean the top sill
Spray the top sill with a mild cleaning solution and wipe it down with a clean cloth or paper towel
Spray the top sill with sanitizer and allow it to air dry
2. Clean the rear doors and tracks (if applicable)
Remove the rear doors from the tracks
Use a mild glass cleaner and a clean paper towel or cloth and wipe down the doors
Spray the doors with sanitizer and allow them to air dry
Spray the door tracks with a mild cleaning solution and wipe them down with a clean cloth or
paper towel
A bottle brush may be used for cleaning the grooves in the door track
When cleaning the rear door tracks, be sure to clean the debris to the outside of the door
track where there is a “wipe-out” groove machined into the track.
Replace the rear doors into the tracks
3. Clean the Coolgenix display pans and interior components
Depending on the case design, the front glass will lift or swingout to access the Coolgenix pans
Make sure the surface of the pan is room temperature before cleaning
If you have not done so already, remove the pan sensor located on the bottom of the center pan
in the case
If the case is equipped with quick connects, disconnect the coolant hoses from the pans using
the quick connects on the hoses. Don’t worry – it is normal for a
few drops of the secondary fluid to escape when disconnecting the
pans. It is a food grade solution that will not harm you or the case.
Coolgenix shelving and step deck applications will have the quick connects for ease of removal
for cleaning
If the case is not equipped with quick disconnects, carefully lift the pans and lean against the
front of the case until the case tank is cleaned
Remove the pan spanner bars and rear pan support bars
Quick connect hoses. Push the gray button to
disconnect the hoses to remove the Coolgenix
deck pan.

Spray the Coolgenix deck pans, spanner bars and rear pan support bars with a mild cleaning
solution and wipe them down with a clean cloth or paper towel
DO NOT put the deck pans in the dishwasher. Elevated temperatures can cause them to distort
and leak with the increase in internal temperature
Spray the deck pans, spanner and rear pan support bars with sanitizer and allow them to air dry
4. Clean the tank
Thoroughly spray the tank with soap and hot water or a cleaning solution and let stand for 5
minutes
Do not spray cleaning solution or water directly on electrical connections
Scrub any heavily soiled areas with a non-abrasive cleaning pad
Rinse the case interior using warm to hot water
Apply sanitizer solution to the tank
Dry interior glass with clean, dry paper towels or cloth
Allow the remainder of the case to air dry
5. Clean the front glass
For standard glass, use a mild glass cleaner and a clean paper towel or cloth to wipe the glass
For non-glare glass, refer to special cleaning instructions contained on the CD or in the case
installation manual
6. Clean prep areas
Remove cutting board
Spray the cutting board with a mild cleaning solution and wipe it down with a paper towels or a
clean cloth
Spray the cutting board with sanitizer and allow it to air dry
Spray the rear sill with a mild cleaning solution and wipe it down with paper towels or clean cloth
Spray the rear sill with sanitizer and allow it to air dry
Replace the cutting board
7. Clean the exterior
Spray the exterior panels with a mild cleaning solution and wipe them down with a paper towel or
clean cloth
Spray the exterior panels with sanitizer and allow the panels to air dry
Post Cleaning Check List
Make sure that the drain is free of debris that could have accumulated during cleaning
Clean up any spills on the floor
Make sure that all components have completely air dried

Turn on the electrical circuit and verify operation of electrical components
Turn on the refrigeration to the cases either at the power supply, through the controller or it will
automatically turn back on after 90 minutes if the push button cleaning switch is installed on the
display case
Re-install the Coolgenix deck pans, spanner bars, and rear pan support bars back into the case.
It is essential to insure the spanner bars are set back in place to
prevent the pans from warping
If you have Coolgenix deck pans with disconnects, reconnect the pan to the quick connect hose
Reconnect the sensor to the center pan and insure proper contact - The sensor is essential for
the case to PROPERLY FUNCTION AND MAINTAIN PROPER PRODUCT TEMPERATURES.
Once proper temperature is established in the case, restock the case according to the store plan-
o-gram
Location of pan sensor found on the
bottom of the center deck pan in the
display case.
Adjustable rear pan support is shown at top arrow.
Spanner bar is located between pans to prevent
pans from warping.