manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DRAKE
  6. •
  7. Media Converter
  8. •
  9. DRAKE TUM714 T User manual

DRAKE TUM714 T User manual

AUDIO
VMM600
VIDEO
PWR
A/V
RF
CH
#
AUDIO
DMM806
VIDEO
PWR
A/V
RF
CH
#
POWER
TUM714
AUDIO
VMM600
VIDEO
PWR
A/V
RF
CH
#
AUDIO
DMM806
VIDEO
PWR
A/V
RF
CH
#
POWER
TUM714
AUDIO
VMM600
VIDEO
PWR
A/V
RF
CH
#
AUDIO
DMM806
VIDEO
PWR
A/V
RF
CH
#
POWER
TUM714
AUDIO
VMM600
VIDEO
PWR
A/V
RF
CH
#
AUDIO
DMM806
VIDEO
PWR
A/V
RF
CH
#
PSM 121 POWER SUPPLY
POWER
TUM714
THREE YEAR LIMITED WARRANTYTHREE YEAR LIMITED WARRANTY
THREE YEAR LIMITED WARRANTYTHREE YEAR LIMITED WARRANTY
THREE YEAR LIMITED WARRANTY
R.L. DRAKE COMPANY warrants to the original purchaser this product shall be free from defects in material or workmanship for three (3)
years from the date of original purchase.
During the warranty period the R.L. DRAKE COMPANY or an authorized Drake service facility will provide, free of charge, both parts and
labor necessary to correct defects in material and workmanship. At its option, R.L. DRAKE COMPANY may replace a defective unit.
To obtain such warranty service, the original purchaser must:
(1)(1)
(1)(1)
(1) Retain invoice or original proof of purchase to establish the start of the warranty period.
(2)(2)
(2)(2)
(2) Notify the R.L. DRAKE COMPANY or the nearest authorized service facility, as soon as possible after discovery of a possible defect,
of:
(a) the model and serial number,
(b) the identity of the seller and the approximate date of purchase; and
(c) A detailed description of the problem, including details on the electrical connection to associated equipment and the list of such
equipment.
(3)(3)
(3)(3)
(3) Deliver the product to the R.L. DRAKE COMPANY or the nearest authorized service facility, or ship the same in its original container
or equivalent, fully insured and shipping charges prepaid.
Correctmaintenance,repair,andusearenecessarytoobtainproperperformancefromthisproduct. ThereforecarefullyreadtheInstruction
Manual. This warranty does not apply to any defect that R.L. DRAKE COMPANY determines is due to:
(1)(1)
(1)(1)
(1) Improper maintenance or repair, including the installation of parts or accessories that do not conform to the quality and specifications
of the original parts.
(2)(2)
(2)(2)
(2) Misuse, abuse, neglect or improper installation.
(3)(3)
(3)(3)
(3) Accidental or intentional damage.
All implied warranties, if any, including warranties of merchantability and fitness for a particular purpose, terminate three (3) years from the
date of the original purchase.
The foregoing constitutes R.L. DRAKE COMPANY’S entire obligation with respect to this product, and the original purchaser shallhave no
other remedy and no claim for incidental or consequential damages, losses or expenses. Some states do not allow limitations on how long
an implied warranty lasts or do not allow the exclusions or limitation of incidental or consequential damages, so the above limitation and
exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This warranty shall be
construed under the laws of Ohio.
®
TUM714T CHANNEL UP-CONVERTER 1
4
WARRANTY AND SPECIFICATIONS
R.L. DRAKE COMPANY
230 INDUSTRIAL DRIVE
FRANKLIN, OHIO 45005 U.S.A.
CUSTOMER SERVICE AND PARTS TELEPHONE: +1 (937) 746-6990
TELEFAX: +1 (937) 743-4576
WORLD WIDE WEB SITE: http://www.rldrake.com
®
POWER
TUM714
AUDIO
DMM806
VIDEO
PWR
A/V
RF
CH
#
POWER
TUM714
AUDIO
DMM806
VIDEO
PWR
A/V
RF
CH
#
12 POSITION RACK MOUNT POWER SUPPLY
® is a registered trademark of the R.L.Drake Company
© Copyright 2002 R.L. Drake Company P/N: 3852343A-6-2002 Printed in U.S.A.
4 POSITION
RACK MOUNT
POWER SUPPLY
OR
TUM714
DESCRIPTION
The R.L. Drake model TUM714 is a "T" channel
block up-converter packaged in a one unit wide
mini-rack package. This unit is compatible with
the Drake 12 position and 4 position rack
mounting frames for use in a 19" wide rack.
There are twelve one unit wide slots, in addition
to space for the power supply (in the 12 position
rack unit).
The up-converter accepts inputs in the "T"
channel range of 5 through 54 MHz and
up-converts an input signal to an output that is
168.25 MHz higher in frequency than the input.
Thus, "T" channels T7 through T14 are
converted to outputs at standard EIA CATV
channels 7 through 13 and channel 23.
Typically, the TUM714 will be used in
conjunction with a demodulator to derive NTSC
video and audio from a "T" channel signal. The
maximum input signal level that can be
accepted by the TUM714 without significant
distortion is +30 dBmV. The TUM714 has
approximately unity gain. The unit may also be
used to translate digital QPSK, QAM, or USB
signals as well as analog NTSC signals.
DEMODULATOR
POWER
TUM714
2
FRONT PANEL INDICATOR / REAR PANEL CONNECTIONS
F1
Figure 1
F1 - POWER Indicator
Lights when the unit is connected to the
required source of DC power via the rear panel
DC INPUT connector.
INSTALLATION / SPECIFICATIONS 3
R1
R2
R3
R1 - RF OUTPUT Connector
This is the RF output to a demodulator.
R2 - DC INPUT Connector
This 3-pin connector (Male) accepts the
appropriate mating DC power cable. Observe
proper orientation and wiring.
R3 - RF INPUT Connector
This is the RF input and accepts inputs from
5 to 54 MHz.
Figure 2
+5V
+12V
GND
VIDEO OUT RF OUT
AUDIO OUT
RF IN RF IN
DC INPUT
+5V
+12V
GND
VIDEO OUT
AUDIO OUT
RF IN
DC INPUT
+5V
+12V
GND
VIDEO OUT
AUDIO OUT
RF IN
DC INPUT
+5V
+12V
GND
VIDEO OUT
AUDIO OUT
RF IN
DC INPUT
+5V
+12V
GND
RF OUT
RF IN
RF OUT
RF IN
RF OUT
RF IN
20 37
119
+5 VDC
(4.5A Max):
Pins 1,4, 7,
12, 15, 18,
21, 24, 27,
30, 33, 36.
+12 VDC
(3A Max):
Pins 2,3, 5,
6, 8, 9, 11,
13, 14, 16,
17, 19.
GND:
Pins 10, 20,
22, 23, 25,
26, 28, 29,
31, 32, 34,
35, 37.
100-240 V
50/60 Hz
75 WATTS
Connect the output from the TUM714 to the
demodulator input or to other desired
equipment.
Figure 3
FROM SUB-BAND
SIGNAL SOURCE TO
TUM714 "RF IN"
("T" CHANNEL INPUT)
DC POWER CABLES
"RF OUT" OF TUM714 TO "RF IN" OF
DEMODULATOR OR OTHER EQUIPMENT
SPECIFICATIONS Input Frequency Range:
Input Impedance:
Output Frequency Range:
Output Impedance:
Gain:
Noise Figure:
L.O. Frequency:
Input Level:
Third Order Input Intercept Point:
Power Requirement (from PSM121):
Operating Temperature Range:
Size:
Weight
5 MHz to 54 MHz.
75 Ohms, return loss >14 dB.
173 MHz to 223 MHz.
75 Ohms, return loss >14 dB.
0 dB, ±2 dB.
<10 dB.
168.25 MHz, ±2 kHz.
+30 dBmV maximum for
-60 dB harmonics and intermods.
>+60 dBmV.
+12 V @ 75 mA.
+5 V @ 10 mA.
00to +500C, ambient.
1” W x 3.5” H x 8.75” D. (2.5 cm) W x (8.9 cm) H x
(22.2 cm) D.
10.2 oz. (0.3 Kg).
Specifications subject to change without notice or obligation.
INSTALLATION
Mount the TUM714 in the 12 position rack
frame. Connect a power cable from the power
supply to the power connector on the TUM714.
Connect the "T" channel input as indicated in
Figure 3.
POWER SUPPLY

This manual suits for next models

1

Other DRAKE Media Converter manuals

DRAKE 1002613A User manual

DRAKE

DRAKE 1002613A User manual

DRAKE SDM1000 User manual

DRAKE

DRAKE SDM1000 User manual

DRAKE ENCODER HOST EH244 User manual

DRAKE

DRAKE ENCODER HOST EH244 User manual

DRAKE DUC864 User manual

DRAKE

DRAKE DUC864 User manual

DRAKE DAV860 User manual

DRAKE

DRAKE DAV860 User manual

DRAKE DSE24A User manual

DRAKE

DRAKE DSE24A User manual

DRAKE DSE24 User manual

DRAKE

DRAKE DSE24 User manual

DRAKE HDE24 User manual

DRAKE

DRAKE HDE24 User manual

DRAKE DAD860 User manual

DRAKE

DRAKE DAD860 User manual

DRAKE 1002606 User manual

DRAKE

DRAKE 1002606 User manual

DRAKE HDE24A User manual

DRAKE

DRAKE HDE24A User manual

DRAKE PEG PLUS User manual

DRAKE

DRAKE PEG PLUS User manual

DRAKE EH24A User manual

DRAKE

DRAKE EH24A User manual

DRAKE ENCODER HOST EH244 User manual

DRAKE

DRAKE ENCODER HOST EH244 User manual

DRAKE HDE24 User manual

DRAKE

DRAKE HDE24 User manual

DRAKE MMTS20 User manual

DRAKE

DRAKE MMTS20 User manual

DRAKE EH24 User manual

DRAKE

DRAKE EH24 User manual

DRAKE ND-24-IP User manual

DRAKE

DRAKE ND-24-IP User manual

DRAKE ND-24-IP User manual

DRAKE

DRAKE ND-24-IP User manual

DRAKE DSE24A User manual

DRAKE

DRAKE DSE24A User manual

DRAKE PEG-NE24-IP-C User manual

DRAKE

DRAKE PEG-NE24-IP-C User manual

DRAKE DDC864A User manual

DRAKE

DRAKE DDC864A User manual

DRAKE SDI24A User manual

DRAKE

DRAKE SDI24A User manual

DRAKE PEG-NE24-IP User manual

DRAKE

DRAKE PEG-NE24-IP User manual

Popular Media Converter manuals by other brands

B&R 5COSD4.1002-00 user manual

B&R

B&R 5COSD4.1002-00 user manual

LDT LS-DEC-CFL-F Operating	 instruction

LDT

LDT LS-DEC-CFL-F Operating instruction

Nexans XPLORER Series instructions

Nexans

Nexans XPLORER Series instructions

Allied Telesis AT-MMC6005 installation guide

Allied Telesis

Allied Telesis AT-MMC6005 installation guide

Blackbird 43876 user manual

Blackbird

Blackbird 43876 user manual

TP-Link MC110CS user guide

TP-Link

TP-Link MC110CS user guide

Lika ROTACOD AMR58 Series manual

Lika

Lika ROTACOD AMR58 Series manual

Mutec MC-4 operating manual

Mutec

Mutec MC-4 operating manual

ADF Web HD67E58-A1 user manual

ADF Web

ADF Web HD67E58-A1 user manual

Lynx C DA 5010 Reference manual

Lynx

Lynx C DA 5010 Reference manual

Teradek T-RAX user guide

Teradek

Teradek T-RAX user guide

Elatec TCP3 3.0.3.1 Technical manual

Elatec

Elatec TCP3 3.0.3.1 Technical manual

Labgear MRX700 quick start guide

Labgear

Labgear MRX700 quick start guide

CAKEWALK UM-1G owner's manual

CAKEWALK

CAKEWALK UM-1G owner's manual

Baumer Hubner Berlin POG 9 + FSL Mounting and operating instructions

Baumer

Baumer Hubner Berlin POG 9 + FSL Mounting and operating instructions

Korenix JetCon 2301 V2 Series Quick installation guide

Korenix

Korenix JetCon 2301 V2 Series Quick installation guide

MRC 0001905 quick start guide

MRC

MRC 0001905 quick start guide

Teradek 600 Series reference guide

Teradek

Teradek 600 Series reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.