Duronic BPM450 User manual

Creative Consumer Electronics
Blood Pressure Monitor BPM450
PLEASE READ ALL THE INSTRUCTIONS BEFORE USE

2

3
English Manual
Manuel d’utilisation en français
Gebrauchsanleitung auf Deutsch
Manual de Instrucciones en Español
Manuale D’istruzioni In Italiano
5
29
53
77
101
Contents

4

5
English Manual

6
Contents
INTRODUCTION
Safety Information
LCD Display Signal
Monitor Components
BEFORE YOU START
The choice of power supply
Installing and replacing the batteries
Setting date, time and measurement unit
MEASUREMENT
Tie the cuff
Start a measurement
THE OPERATION OF RECALLING RECORDS
Recall the records
Delete the records
INFORMATION FOR USER
Tips for operation
Maintenance
ABOUT BLOOD PRESSURE
What are systolic pressure and diastolic pressure?
What is the standard blood pressure classication?
Why does my blood pressure uctuate throughout the day?
Why do I get a different blood pressure at home compared to the hospital?
Is the result the same if measuring both arms?
TROUBLESHOOTING
SPECIFICATIONS
AUTHORIZED COMPONENT
CONTACT INFORMATION
COMPILED EUROPEAN STANDARDS LIST
EMC GUIDANCE
7
9
10
11
11
12
14
15
16
17
18
19
20
20
21
21
21
22
23
24
25
24

7
Safety Information
SN
Thank you for selecting SHINEMART arm type blood pressure monitor. The
monitor features blood pressure measurement, pulse rate measurement and
auto-save the result. The design provides you with two years of reliable
service. Readings taken by the blood pressure monitor are equivalent to those
obtained by a trained observer using the cuff and stethoscope auscultation
method. This manual contains important safety and care information, and
provides step by step instruction for using the product. Read the manual
thoroughly before using the product.
Features:
148mm×29mm Digital LCD display
Touch sensor key
Maximum 60 records per user
Measuring during ination technology
The below signs might be in the user manual, labeling or other component.
They are the requirement of standard and using.
THE OPERATION GUIDE
MUST BE READ
CE Mark: conforms to essential
requirements of the Medical
Device Directive 93/42/EEC.
Type BF Applied Parts
DISPOSAL: Do not dispose this product
as unsorted municipal waste. Collection of
such waste separately for special treatment
is necessary.
Authorized Representative in the European
Community
Direct Current
Manufacturer
Manufacture Date
Species Serial Number EC REP

8
This device is intended for adult use only.
This device is intended for non-invasive measuring and monitoring of arterial blood pressure.
It is not intended for use on extremities other than the arm or for functions other than obtaining a
blood pressure measurement.
Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood
pressure.Do not begin or end medical treatment without asking a physician for treatment advice.
If you are taking medication,consult your physician to determine the most appropriate time to
measure your blood pressure. Never change a prescribed medication without consulting your
Physician.
When the device was used to measure patients who have common arrhythmias such as atrial or
ventricular premature beats or atrial brillation, the results may deviate. Please consult your
physician about the result.
If the cuff pressure exceeds 40 kPa (300 mmHg), the unit will automatically deate. Should the
cuff not deate when pressures exceeds 40 kPa (300 mmHg), detach the cuff from the armand
press the START/STOP button to stop ination.
The equipment is not AP/APG equipment and not suitable for use in the presence of a ammable
anesthetic mixture with air of with oxygen or nitrous oxide.
The operator should not touch the batteries /adapter and the patient simultaneously.
To avoid measurement errors, please avoid the condition of strong electromagnetic eld radiated
interference signal or electrical fast transient/burst signal.
The user must check that the equipment functions safely and see that it is in proper working
condition before being used.
This device is contraindicated for any female who may be, or is pregnant. Besides providing
inaccurate readings, the effects of this device on the fetus are unknown. Manufacturer will make
available on request circuit diagrams, component parts list etc.
This unit is not suitable for continuous monitoring during medical emergencies or operations. It
could cause the patient’s arm to become red and swollen due to the blood supply being cut off.
Please use the device under the environment which was provided in the user manual. Otherwise,
the performance and lifetime of the device will be impacted and reduced.
During use, the patient will be in contact with the cuff. The materials of the cuff have been tested
and found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010. It will not
cause any potential sensization or irritation reaction.
Please use ACCESSORIES and detachable partes specied/ authorised by MANUFACTURE.
Otherwise, it may cause damage to the unit or danger to the user/patients.
The device does not need to be calibrated within two years of reliable service.
Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according to the
local guidelines.
If you have any problems with this device, such as setting up, maintaining or using, please
contact the SERVICE PERSONNEL of SHINEMART. Do not open or repair the device by
yourself. Please report to SHINEMART if any unexpected operation or events occur.
Please use the soft cloth to clean the whole unit. Do not use any abrasive or volatile cleaners.
CAUTION

9
Average The average of blood pressure
Recalling The records will be shown
Arrhythmia Irregular heartbeat
Grade The grade of the blood pressure.
LCD display signal
SYS
DIA
Pul/min
8:59
mmHg
kPa
Symbol Description Explanation
Systolic blood pressure High pressure result
Low pressure result
Pulse/minute
CUFF air is exhausting
of deating
Measurement Unit of the
blood pressure
Measurement Unit of the blood
pressure (1kPa=7.5mmHg)
Batteries are low and
need to be replaced
Shocking will result in
inaccurate
Currently time
If “M” shows, the displayed measurement
values is from the memory.
Diastolic blood pressure
Pulse
Deating
Time (hour:minute)
Memory
mmHg
kPa
Low battery
Shocking remaining

10
Monitor Components
List
Air Hose
Cuff
DC Power
Socket
Set/Up Button
Start/Off Button
Mem/Down Button
LCD Display
Air Connector Plug
Battery Compartment
Component list of
pressure measuring system
1 Cuff
2 Air pipe
3 PCBA
4 Pump
5 Valve
1. Blood Pressure Monitor 2. Cuff (22-42cm) 3. 4*AAA Alkaline Batteries
4. User Manual

11
The Choice of Battery
The Installment And Replacement Of Battery
1.Battery powered mode:
6VDC 4*AAA batteries
2.AC adaptor powered mode:
(Can be supplied by AC adaptor model
UE08WCP-060100SPA only!)(Not Included)
Right picture is the socket for power
adapter.
Caution
In order to get the best results and protect your
monitor, please use the right battery and special
power adapter.
Caution
Remove batteries if the device is not likely to be used for some time.
The old batteries are harmful to the environment, do not dispose with other daily trash.
Remove the old batteries from the device and follow your local recycling guidelines.
Do not dispose of batteries in re. Batteries may explode or leak.
1. Slide off the battery cover.
2. Install the batteries by matching
the correct polarity, as shown.
3. Replace the cover.
Replace the batteries whenever the
following happens:
The shows
The display dims
The display does not light up

12
Setting the date, time and measurement unit
It is important to set the clock before using your blood pressure monitor,
so that a time stamp can be assigned to each record that is stored in the
memory. (year :2000—2050,time:24 H)
1. When the unit is off,
press and hold “SET”
for 3 seconds to enter
the mode for year
setting.
2.Press the “MEM” to
change the [YEAR].
3.When you get the
right year, press
“SET” to select and
turn to next step
automatically.

13
4. Repeat steps 2 and 3 to set the [MONTH] and [DAY].
5. Repeat steps 2 and 3 to set the [HOUR] and [MINUTE].
6. Repeat steps 2 and 3 to set the [UNIT].
7. After the unit is set,the right picture
will show,then it turn off automatically.

14
Tie The Cuff
1. Tie the cuff on your upper arm,
then position the tube off-center
toward the inner side of arm in
line with the little nger.
2. The cuff should be snug but not
too tight. You should be able to
insert one nger between the
cuff and your arm.
3. Sit comfortably with your left
arm resting on a at surface.
Rest for 5 minutes before
measuring.
Wait at least 3 minutes between
measurements. This allows your
blood circulation to recover.
For a meaningful comparison,
try to measure under similar
conditions. For example, take daily
measurements at approximately
the same time, on the same arm,
or as directed by a physician.

15
Start The Measurement
1. Press the “START/STOP” to turn on
the monitor, and it will nish the whole
measurement automatically.
LCD display
Adjust to zero
automatically.
Inating and
measuring
automatically.
Display and save the
results automatically.
2.Press the “START/STOP” to
power off, otherwise it will turn
off automatically within 1 minute.

16
Recalling the records
1. When the BPM is
off, please press the
“MEM” to show the
average of the
records.
The sign of “AVG”
will show in the right
corner.
2. Press the “MEM”
or “SET” to get the
record you want.
Caution
The most recent record (1) is shown rst. Each new
measurement is assigned to the rst (1) record. All other records
are pushed back one digit (e.g., 2 becomes 3, and so on), and the
last record (60) is dropped from the list.
The order of
the record,date,
time will display
alternately.

17
Deleting a measurement record from memory
1.Press and hold
“MEM” for 3
seconds ,the ash
display will show.
2.Press “SET” to
conrm deleting and
the monitor will turn
off automatically.
3.If you do not want to delete the
records, press “START/STOP” to
escape.
4. If there is no record.
the right display will
show.
If you did not get the correct measurement, you can delete all results by
following steps below.

18
Tips For Measurement
Measurements may be inaccurate if taken in the following circumstances.
Wait at least 1 hour after
dinner or drinking
Wait at least 20 minutes
after taking a bath
In a very cold environment
When talking or moving
your ngers
When you need the toilet
Immediate measurement
after tea, coffee, smoking

19
Maintenance
In order to get the best performance, please follow the below instructions.
Store in a dry place and
avoid direct sunlight
Avoid intense shaking
and collision
Use a wet cloth to remove
the dirt
Avoid the dusty and unstable
temperature environment
Avoid washing the cuff
Avoid touching water

20
What are systolic pressure and diastolic pressure?
When ventricles contract and pump blood
out of the heart, blood pressure reaches its
maximum value, the highest pressure in the
cycle is known as systolic pressure. When the
heart relaxes between heartbeats, the lowest
blood pressure is diastolic pressure.
What is the standard blood pressure
classication?
Irregular Heartbeat Detector
Below illustrates the blood pressure
classication mode by World Health Organization
(WHO) and International Society of Hypertension
(ISH) in 1999.
An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is
measuring the systolic and diastolic blood pressure. During each measurement,
this equipment records the heartbeat intervals and works out the standard deviation.
If the calculated value is larger than or equal to 15,the irregular heartbeat symbol
appears on the symbol when the measurement results are displayed.
Caution: Only a physician can tell you your normal blood pressure range and the
point at which you are at risk. Consult your physician to obtain these values.
If the measurements taken with these products fall outside the range.
Table of contents
Languages:
Other Duronic Blood Pressure Monitor manuals