DVS EC User manual

DVS®EC CLIMATE CONTROLLED
HUMIDITY SENSITIVE (MY20)
USER GUIDE
ENJOY A HEALTHIER, MORE COMFORTABLE HOME
0800 387 387 www.dvs.co.nz

Displayed on the home screen
Optional features, if
in operation, appear
here.
Fan symbol, spinning
if fan is running.
Menu / On / O
Supply air temperature
at the fan unit.
House temperature at
the keypad.
Set Temperature.
Filter change indication
(if it is due) appears here.
Humidity Sensor.
Turning the system ON or OFF: Press and
hold MENU to turn the system On or O.
Set Temperature: Press the arrows to
adjust. This is the temperature the system will
try to achieve.
Set and Forget or Customise. You can,
for example set this to 21oC. A typically
ecient setting to provide good 'year round'
performance, or you can adjust seasonally if
you wish.
In Summer, if you select a Set Temperature
of 18oC for example, the house will reach this
temperature quickly. The system will turn o,
preventing warm air being introduced. The
system starts again when the air supply is
cooler than 18oC.
In Winter, You could select a higher Set
Temperature of 23oC for example. When, or if,
there is heat available from the air supply, the
system will be in Heat Recovery mode and will
try to reach 23oC in the home more quickly.
Note: The system will continue to operate
even if the roof space is cooler than the house.
The system will reduce the air supply rate to a
programmed minimum requirement when the
air supply is cooler. The air ow rate can reduce
further if you have Heat Retention activated,
however this may aect the performance of
the system.
Standard Features:
To access the standard features: Press the
MENU button. (This changes the screen to the
rst menu). Then move the highlight by using
to select the desired function and press
to enter that function. Press the MENU
Button at any time to return to the previous
screen.
Note: If there are optional features tted they
will be included on the rst menu page.
Fan Settings
Access settings for Fan Speed, Heat Retention,
Heat Recovery and Humidity Sensitivity.
Heat Retention. This automatically adjusts
the fan speed (air supply rate) down in cold
conditions if the air supply is cooler than the
air inside the home.
Standard setting = 'OFF'.
If you experience cooling from the system you
are able to activate this feature. We suggest
making small changes of one segment at a
time, then assessing the need to increase it.
Note: Altering the above Heat Retention
Setting will alter the behavior of your system.
If performance is reduced, adjust this setting
back to where it was originally set. If unsure
please contact our service department before
you alter any of the settings.
Heat Recovery. This automatically increases
the fan speed (air supply rate) when there
is enough heat to recover from the ceiling,
and the house is not yet at, or above the Set
Temperature (measured at the keypad).
Standard setting = 'ON' 7 segments.
Note: Heat Recovery and Heat Retention
settings automatically adjust fans speeds
once they are set. They can also be adjusted
at any time.
Hum. Settings. For adjusting the sensitivity
of the system to an air supply which is more
humid than the air inside the home.
Hum. Settings - Hum. Sens. Sets the level
of sensitivity of the system to the supply air
being more humid than the air inside the home.
Ranging from OFF, LOW, MED, Hi (high), V Hi
(very high).
Standard setting = 'Hi'.
Hum. Settings - Hum. Time. Sets the time the
system will allow supply air to be more humid
than the inside air. So; this setting creates
a delayed reaction, ranging from Instant, V
Hi (15mins), Hi (30mins), Med (45mins), Low
(60mins).
Standard setting = 'Instant'.
Note: Altering the Humidity Settings will alter
the behavior of your system. If performance is
reduced, adjust this setting back to where it
was originally set. If unsure please contact our
service department.
Fan Boost. When in Fan Boost, the system
will operate at maximum speed (max air supply
rate) for a set amount of time, and then it will
revert back to condensation control speed.
Utilities
For access to: Setting the System Clock,
turning the Backlight On/O, setting the
System Timer, Resetting the Filter Timer,
viewing Temperature and Humidity graphs and
System Diagnositics.
Optional Features
These includes the Tempervent Air warmer.
To access the optional features (if tted):
Press the MENU button. (This changes the
screen to the rst menu) Then move the
highlight by using the arrows to select
the desired option and press to select that
option.
Mode: The way you want the optional feature
to be activated. (Follow the prompts at the
bottom of each screen to help you set these.)
Recommended Settings
Air Warmer:
Cooler months = 'ON - Mode = Temp (8oC) +
Timer (ON 2100 / OFF 0700).
Fan Speed = (MED).
Note: This limits the time on and the air supply
temperature below which the feature will
operate.
Warmer months = 'OFF'.
Fan Speed: The Fan Speed the optional feature
will run at when it is on.
Remember: Where you leave the highlight is
the mode in which the feature will switch on. If
a feature is currently active, it will show on the
home screen in red.
Other Settings
You are able to choose alternative modes of
operation for the above optional feature. If
system performance reduces, please revert to
the recommended settings.
For further assistance please call DVS®on 0800 387 387 For further assistance please call DVS®on 0800 387 387

For further assistance please call DVS®on 0800 387 387 or visit www.dvs.co.nz
DVS® System Installed on: Invoice Number:
Installed by:
F6 Carbon MERV12Filter(s) type and number: F7 MERV13
Useful Tips
System Performance
Your DVS® will help to provide a healthier,
drier living environment.
Ventilation, heating (in cooler months) and
cooling (in warmer months) are all keys
to providing a drier, healthier and more
comfortable living environment.
Winter: (or cooler months). Your DVS® is
programmed to supply enough ventilation for
your home based on the size of your home. If
the home is now drier, you may wish to reduce
the level of ventilation using the Fan Speed
adjustment (see page one). The ideal being to
have the minimum level of ventilation while
retaining a drier, healthier home.
If the home is not yet drier, you can increase
the Fan Speed adjustment to ventilate at a
higher level.
Summer: (or warmer months). Experience has
found that increasing the Fan Speed setting
to higher levels provides better ventilation in
warmer months.
Note: Also see Set Temperature on page one.
If you feel you have system performance
issues e.g. wet windows, turn the system o
and call DVS® so that we can assist.
Filter(s).
Maintenance of the equipment, including
replacement of the air lter(s) with genuine
DVS® lter(s), is required to ensure the
durability and performance of the system
for the warranty period and beyond. As the
serviceable life of the DVS® lter(s) will vary
with location and environmental factors
outside of the control of the Company, Proven
Systems Limited recommends replacing the
lter(s) with a genuine DVS® lter(s) annually.
A message will show on the controller when
your lter(s) are due to be changed
Contact DVS® to purchase lters or
arrange for one of our service technicians
to come and change your lter for you.
Five Year Warranty
DVS® Manufactured and branded products
carry a 5 year on site parts and labour
warranty. The warranty is dated (begins) on
the day of installation and/or supply of the
goods. Non DVS® manufactured and branded
products carry the warranty provided by the
specic product manufacturer.
The warranty covers manufacturing faults in
the product (equipment) and product failure
caused by incorrect installation.
Popular Temperature Controllers manuals by other brands

Ropex
Ropex RESISTRON RES-5027 operating instructions

Hobo
Hobo S-THB-M002 manual

REGLOPLAS
REGLOPLAS 300L operating instructions

Binder
Binder KBF P 240 translation of original operation manual

MAXA
MAXA HCN Series Installation, Use and Technical Manual

ClimateMaster
ClimateMaster DOAS CM3500 Operating & maintenance instructions