INSTALLATION INSTRUCTIONS FOR EMERGENCY LIGHTING FIXTURES
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed including the following:
SAVE THESE INSTRUCTIONS!
ELECTRICAL CONNECTIONS
WALL MOUNTING
CEILING MOUNTING WITH SURFACE CONDUIT FEED
1. To avoid the possibility of electric shock, turn off power supply before
installation or servicing.
2. Review the diagrams thoroughly before installation.
3. All electrical connections must be in accordance with the NEC and local codes.
A qualified electrician should do all the work.
4. Do not let power supply cords touch hot surfaces.
5. Do not mount near gas or electric heaters.
6. Equipment should be mounted in locations where it will not be readily subject to tampering by unauthorized personnel.
7. The use of accessory equipment not recommended by the original manufacturer may cause an unsafe condition.
8. Do not use this equipment for other than intended use.
9. All servicing should be performed by qualified personnel only.
1. Verify the power is off before installation.
2. Connect ground (Green) lead to suitable ground.
3. Connect fixture Neutral (White) lead to supply neutral (White) lead.
4. Determine supply voltage for fixture. Connect hot lead (Black for 120V or Red or Orange for 277V) to supply hot lead.
Cap unused fixture lead with wire nut.
1. Separate front cover from back plate with a flat blade screwdriver. Open from top slot first and then from side slots gently.
(See Figure1)
2. Remove knock out hole in the center of the back plate. Remove knock out slots on the back plate that correspond
to the size of the junction Box.
3. Feed AC supply leads through the center hole in the back plate. Then make the proper electrical connections. See electrical
connections section for proper instructions. Cap off unused hot lead.
4. Mount back plate to junction box with provided #8-32×0.875” screws. (See Figure 2 or Figure 4)
5. Attach battery connector and power connector.
6. Attach front cover to back plate. (Should snap right in)
7. Supply power and test the unit.
1. Separate front cover from back plate with a flat blade screwdriver. Open from top slot first and then from side slots gently.
(See Figure1)
2. Unscrew the pipe plug from top of back plate.
3. Secure back plate screw on the conduit. (See Figure 3 or Figure 5)
4. Make the proper supply lead connections. See Electrical connections section for proper instructions. Cap off unused hot lead.
5. Attach battery connector and power connector.
6. Attach front cover to back plate.
7. Supply power and test the unit.
NOTE: Allow battery to charge for 24 hours before first use.
OPENING FRONT COVER
Figure 1
Flat blade
screwdriver
Open from top slot first then side slot
Side slot
Top slot
Pa
g
e 1 of 4
NOTICE-Use flat blade screwdriver to open. Insert screwdriver in the
slot (one on the top, two on the sides) and gently pry off the cover.
WALL MOUNTING:
Figure 2
Figure 3
WIRING DIAGRAMS:
CEILING MOUNTING WITH SURFACE MOUNTED CONDUIT
Screw (#8-32*0.875")
Back plate
Black (for 120V)
Junction Box (Not Provided)
120VAC
0V NEUTRAL
277VAC
Green (Ground wire)
Transformer power
Connector (female)
White (Neutral)
Red or Orange (for 277V)
Printed
Circuit Board
Transformer power Connector
(male)
Battery
Connector
Front cover assembly
Frame
Black (for 120V)
White (Neutral)
Red or Orange (for 277V)
Screw (#8-32*0.875")
Transformer power Connector
(male)
Back plate
120VAC
0V NEUTRAL
277VAC
GROUND (GREEN)
Green
(Ground wire)
Pa
g
e 2 of 4
PCBA
BAT
Transformer
Power Connector
Transformer
LED
Front Cover
LED Module
LENS
Front Cover
LED Module
LENS
WALL MOUNTING:
COLD WEATHER OPTION ONLY
WIRING DIAGRAMS:
Figure 5
Figure 4
CEILING MOUNTING WITH SURFACE
MOUNTED CONDUIT
Transformer power Connector
(male)
Black (for 120V)
Junction Box (Not Provided)
Page 3 of 4
Green (Ground wire)
Back plate
Screw (#8-32*0.875")
Heater power connector
(male)
White (Neutral)
Red or Orange (for 277V)
120VAC
0V NEUTRAL
277VAC
Transformer power
Connector (female)
Frame
Battery
Connector
Heater connector
(female)
120VAC
0V NEUTRAL
277VAC
GROUND (GREEN)
Green
(Ground wire)
Black (for 120V)
White (Neutral)
Red or Orange (for 277V)
Screw (#8-32*0.875")
Heater power connector
(male)
Transformer power
Connector (male)
Back plate
JUMPER
Heater power
connector (female)
Printed
Circuit Board
*Note :
1. 2pcs short circuit connector in the accessory bag.
2. For 120Vac input connection, short circuit connector
insert in female connector marked JUMPER in slots
1 and 2.
3. For 277Vac input connection, short circuit connector
insert in female connector marked JUMPER in slots
2 and 3.
1
1
2
2
3
3
Black(120Vac)
Red(277Vac)
PCBA
BAT
Transformer
Power Connector
Transformer
LED
Heater
Power Connector
Jumper (See *Note)
Heater
Temperature Sensor
Front Cover
LED Module
LENS
Front Cover
LED Module
LENS
Page 4 of 4
INSTRUCTIONS FOR SELF-DIAGNOSTICTEST:
Once the unit is properly installed according to the installation instruction sheet and AC power supplied,
the dual color LED indicator will come ON and the self-diagnostic test function will automatically initiate.
The LED indicates the unit’s status. A STEADY GREEN LED indicates normal service; FLASHING
GREEN indicates the unit is testing; GREEN/RED FLASHING indicates the battery is charging; RED (in
different combinations) would indicate a service alert. Refer to the SERVICE INDICATION chart below for
more details. The LED would be OFF when the unit is in emergency mode.
SELF-DIAGNOSTIC SERVICE
The self-diagnostic function is factory preset and performs the following:
a. Monitoring of battery, battery charger, and lamps.
b. Self-testing and a 30-second or longer discharge once every 30 days, after AC power has been
supplied for a minimum of 24 hrs.
c. Self-testing and a 30-minute or longer discharge once every 180 days, after AC power has been
supplied for a minimum of 24 hrs.
d. Self-testing and a 90-minute discharge once every 365 days, after AC power has been supplied for
a minimum of 24 hrs.
SERVICE INDICATION
MANUAL TESTING
WARNING:
The unit also provides for manual testing by pushing the test button in a specific pattern.
noitacidnIDEL&noitcaeRnoitcA
Push test button Once (within 2 seconds) 30-second test: FLASHING Green
Push test button Twice (within 2 seconds) 30-minute test: Green FLASHING twice
Push test button Three times (within 2
seconds)
90-minute test: Green FLASHING three times
Push test button and hold for 3 seconds (In
test mode)
Cancels test. If self-test is cancelled it is recommended that a
manual test of the same duration be performed at a more
convenient time to ensure compliance
Push test button and hold for 6 seconds (In
test mode)
System reset
a) Make sure that power is OFF before making any electrical connections.
b) Unused wires must be capped using enclosed wire nuts.
sutatSrotacidnIDEL
scinortceleecalpeRderhsalfenO
yrettabecalpeRderhsalfowT
Four flash red
Replace lamp head board
Steady red
Battery disconnected
Solid green
Trickle charge
Flashing green
In test
Red/Green flashing
Hi charge

Other e-conolight Light Fixture manuals

e-conolight E-XML1RCW User manual

e-conolight

e-conolight E-XML1RCW User manual

e-conolight E-KCN Series User manual

e-conolight

e-conolight E-KCN Series User manual

e-conolight C-LITE C-AR-B-DD Series User manual

e-conolight

e-conolight C-LITE C-AR-B-DD Series User manual

e-conolight E-WPA Series User manual

e-conolight

e-conolight E-WPA Series User manual

e-conolight E-APE Series User manual

e-conolight

e-conolight E-APE Series User manual

Popular Light Fixture manuals by other brands

Eterna vnanobh installation instructions

Eterna

Eterna vnanobh installation instructions

MaxLite PhotonMax Series operating instructions

MaxLite

MaxLite PhotonMax Series operating instructions

RUTEC VARDAflex 3inONE-60 quick start guide

RUTEC

RUTEC VARDAflex 3inONE-60 quick start guide

Lightolier ALETTA AL2T8 specification

Lightolier

Lightolier ALETTA AL2T8 specification

Lightolier Soli 48022ALU specification

Lightolier

Lightolier Soli 48022ALU specification

Lightolier ProSpec 26383W specification

Lightolier

Lightolier ProSpec 26383W specification

Cooper Lighting SSRxx installation instructions

Cooper Lighting

Cooper Lighting SSRxx installation instructions

Vari Lite VL2402 user manual

Vari Lite

Vari Lite VL2402 user manual

Seto Combat Series Instructions for use

Seto

Seto Combat Series Instructions for use

DIVA Light TWP Series Installation instruction

DIVA Light

DIVA Light TWP Series Installation instruction

Paradise Datacom GL38682 quick start guide

Paradise Datacom

Paradise Datacom GL38682 quick start guide

Cooper Lighting AMETRIX Fixture Doors Supplementary instructions

Cooper Lighting

Cooper Lighting AMETRIX Fixture Doors Supplementary instructions

Pinnacle EDGE EX44 Nstallation instructions

Pinnacle

Pinnacle EDGE EX44 Nstallation instructions

Blizzard Lighting Puck RGBAW manual 

Blizzard Lighting

Blizzard Lighting Puck RGBAW manual 

PR Lighting XR440 BWS user manual

PR Lighting

PR Lighting XR440 BWS user manual

Lightolier 8279EN specification

Lightolier

Lightolier 8279EN specification

Lightolier Calculite 8081 specification

Lightolier

Lightolier Calculite 8081 specification

Triarch 30021 Assembly and installation instructions

Triarch

Triarch 30021 Assembly and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.