E2S GNE L2 Series User manual

INSTRUCTION MANUAL (ATEX)
GNExL2 and GNExL1 Flameproof Loudspeakers
1) Introduction
The GNExL2 and GNExL1 are second generation flameproof
loudspeakers which are certified to meet the requirements of
the ATEX directive 94/9/EC and the IECEx scheme. The
loudspeakers can be used in hazardous areas where
potentially flammable atmospheres may be present. There are
four versions of each loudspeaker, 8 ohm or 16 ohm and
70V/100V Line transformer. On 70V/100V line transformer
units there are four output tappings for each size of
loudspeaker. The GNExL2 unit produces output levels in the
117dB(A) range and the GNExL1 unit produces output levels
in the 112dB(A) range.
The loudspeakers are Group II, EPL (equipment protection
level) Gb. Dependant on unit type and ambient temperature
the equipment is certified ‘Ex d IIC Gb’ and as such may be
used in Zones 1 and 2 with flammable gases and vapours with
apparatus groups IIA, IIB & IIC and temperature Classifications
of T1, T2, T3 and T4 dependant on ambient temperature, see
marking codes insection 2.
The equipment is also certified ‘Ex d IIB Gb’ and as such may
be used in Zones 1 and 2 with flammable gases and vapours
with apparatus groups IIA & IIB and temperature
Classifications of T1, T2, T3, T4, T5 and T6 dependant on
ambient temperature, see marking codes in section 2.
2) Marking
All units have a rating label, which carries the following
important information:-
Unit Type No. GNExL2 or GNExL1
Impedance: 8 ohm or 16ohm
70V Line or 100V Line
Codes: GNExL1 Ex d IIC T4 Gb for Ta –60°C to +50°C
Ex d IIC T3 Gb for Ta –60°C to +70°C
Ex d IIB T6 Gb for Ta –60°C to +50°C
Ex d IIB T5 Gb for Ta –60°C to +65°C
Ex d IIB T4 Gb for Ta –60°C to +70°C
Codes: GNExL2 Ex d IIC T4 Gb for Ta –60°C to +50°C
Ex d IIC T3 Gb for Ta –60°C to +65°C
Ex d IIB T6 Gb for Ta –60°C to +50°C
Ex d IIB T5 Gb for Ta –60°C to +65°C
Certificate No. SIRA 13ATEX1139X
IECEx SIR 13.0029X
Certificate No. SIRA 13ATEXXXXXXX
“Warnings”
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE
PRESENT
ELECTROSTATIC HAZARD - CLEANONLY WITH A DAMP CLOTH
IF TEMPERATURE EXCEEDS 70ºC AT ENTRY OR 80ºC AT
BRANCHING POINT USE SUITABLY RATED CABLE AND CABLE
GLANDS
Year of Construction /
Serial No. i.e. 13 / 1GL25000001
3) Type Approval Standards
The loudspeakers have an EC Type examination certificate
issued by SIRA and have been approved to the following
standards:-
EN60079-0:2012 IEC60079-0:2011 (Ed6) GeneralRequirements
EN60079-1:2007 IEC60079-1:2007 (Ed6) Flameproof Enclosure ‘d’
4) Installation Requirements
The loudspeakers must be installed in accordance with the
latest issues of the relevant parts of the EN60079 standards or
the equivalent IEC standards – Selection, Installation and
maintenance of electrical apparatus for use in potentially
explosive atmospheres (other than mining applications or
explosive processing and manufacture):-
EN60079-14:2008 Electrical Installations in Hazardous
IEC60079-14:2007 (Ed4) Areas (other than mines)
EN60079-10-1:2009 Classification of Areas, Gas
Atmosphere
IEC60079-10:2008 (Ed1)
The installation of the units must also be in accordance with
any local codes that may apply and should only be carried out
by a competentelectrical engineer who has had the necessary
training.
5) Zones, Gas Group, Category and Temperature
Classification
The GNExL2 and GNExL1 sounders have been certified Ex d
IIC T4 , T3 and Ex d IIB T6 , T5 ,T4 dependant on ambient
temperature for full marking see section2. This means that the
units can be installed in locations with the following conditions:-
0518
II 2G
Epsilon x:
Equipment Group
and Category:
CE Marking:
NotifiedBody No.

__________________________________________________________________________________________________________________________________
Area Classification:
Zone 1
Explosive gas air mixture likely to occur in
normaloperation.
Zone 2
Explosive gas air mixture not likely to occur,
and if itdoes, it will only existfor a short time.
Gas Groupings:
Group IIA
Propane
Group IIB
Ethylene
Group
IIC
Hydrogen and Acetylene
Equipment Category: 2G
Temperature Classification:
T1
400
o
C
T2
300
o
C
T3
200
o
C
T4
135
o
C
T5
100
o
C
T6
85
o
C
Ambient Temperature Range:
GNExL1 - For range see Marking Codes Section 2
GNExL2 - For range see Marking Codes Section2
6) Loudspeaker Location and Mounting
The location of the loudspeakers should be made with due
regard to the area over which the unit must be audible. The
loudspeakers should only be fixed to services that can carry
the weight of the unit.
The loudspeakers should be securely bolted to a suitable
surface using the 7mm diameter boltholes in the stainless steel
U shaped mounting bracket (see figure 1). The angle can then
be adjusted in the direction that the sound is primarily required
to cover. This can be achieved by loosening the two large
bracket screws in the side of the unit, which allow adjustment
in steps of 18°. On completion of the installation the two large
bracket adjustment screws on the side of the unit must be fully
tightened to ensure that the unit cannot move inservice.
7) SafetyWarning (Electrostatic Hazard)
The acoustic horn section is made of ABS Plastic, therefore to
avoid a possible ELECTROSTACTIC CHARGE the unit must
only be cleaned with a damp cloth.
8) Access to the Flameproof Enclosure
In order to connect the electrical supply cables to the
sounder it is necessary to remove the flameproof cover to
gain access to the flameproof chamber. To achieve by
loosening the M3 Grub Screw within the flameproof cover,
and then unscrew the flameproof cover, taking extreme
care not to damage the flameproof joints in the process.
On completion of the cable wiring installation the flameproof
joints should be inspected to ensure that they are clean and
that they have not been damaged during installation. Also
check that the ‘O’ ring seal is in place. When replacing the
flameproof cover ensure that it is tighten fully with tool
provided.
9) Power Amplifier Selection
It is important that the loudspeakers are connected to power
amplifiers that have outputs that are compatible to the type of
loudspeaker being used. Loudspeakers with a 70V or 100V
line matching transformer fitted must be connected to a power
amplifier with a 70V or 100V line output. Low impedance 8
ohm or 16 ohm loudspeakers must be connected to amplifiers
with a suitable low impedance output. When selecting the
cable size consideration mustbe given to the current that each
unit draws, the number of loudspeakers on the line and the
length of the cable run.
The following table shows the range of loudspeakers:-
Unit Type Input Wattage Max.
I/P Volts
GNExL2 100V Line 25W 100V
GNExL2 70V line 25W 70V
GNExL2 8 ohm 25W 14.14V
GNExL2 16 ohm 25W 20V
GNExL1 100V Line 15W 100V
GNExL1 70V Line 15W 70V
GNExL1 8 ohm 15W 10.95V
GNExL1 16 ohm 15W 15.49V
Figure 1
Flameproof
Chamber
Flameproof
Cover
S/S Mounting
Bracket
Plastic Acoustic Horn
Please seeSafety Warning
in Section7 of this manual
Figure 2

__________________________________________________________________________________________________________________________________
The above table also shows the maximum AC signal voltages
atwhich the loudspeakerscanbe operated.
The current levels taken by the each loudspeaker will depend
on which output tapping has been selected (see section 13 of
this instruction manual). GNExL2 70V and 100V Line units
have output levels of 25W, 12.5W, 6W and 2W; GNExL1 70V
and 100V Line units have output levels of 15W,7.5W, 3W and
1W.
10) Cable Selection
When selecting the cable size consideration must be given to
the input current that each unit draws (see table 2 of 4), the
number of loudspeakers on the line and the length of the cable
runs. The cable size selected must have the necessary
capacity to provide the input current to all of the loudspeakers
connected to the line.
SAFETY WARNING: If temperature exceeds 70ºC at entry or
80ºC at branching point use suitably rated cable and cable
glands.
11) Earthing
Both AC and DC loudspeaker units must be connected to a
good quality earth. The units are provided with external
earthing terminals which are both located on the terminal
chamber section of the unit (see figures 2 and 3).
When using the external earth terminal a cable crimp lug must
be used. The cable lug should be located between the two M4
stainless steelflat washers. The M4 stainless steel spring
washermust be fixed between the outer flat washer and the
M4 stainless steel nut to ensure that the cable lug is secured
against loosening and twisting.
12) Cable Glands
The GNExL2 and GNExL1 sounders have dual cable gland
entries which have an M20 x1.5 entry thread as standard. Only
cable glands approved for Ex ‘d’ applications can be used,
which must be suitable for the type of cable being used and
also meet the requirements of the Ex ‘d’ flameproof installation
standards EN 60079-14:2008 / IEC60079-14:2007.
SAFETY WARNING: If temperature exceeds 70ºC at entry or
80ºC at branching point use suitably rated cable and cable
glands.
If a high IP (Ingress Protection) rating is required then a
suitable sealing washer must be fitted under the cable gland.
When only one cable entry is used the other one must be
closed with an Ex ‘d’ flameproof blanking plug, which must be
suitablyapproved forthe installation requirements.
13) Cable Connections
The cable connections are made into the terminal blocks on
the pcb assembly located in the flameproof enclosure. See
section 8 of this manual for access to the flameproof
enclosure. The 70V and 100V Line loudspeakers arefitted with
a five way terminal block. Terminal A is common and one of
the other terminals B, C, D or E should be selected depending
onwhat output level is required (see table below).
Terminals GNExL2 (25W) GNExL1 (15W)
A -B 25W 15W
A -C 12.5W 7.5W
A -D 6W 3W
A -E 2W 1W
A single wire with a cross sectional area of up to 4mm² can be
connected to each terminal way or if an input and output wire
is required two 2.5mm² wires can be connected to each
terminal way. When connecting wires to the terminals great
care should be taken to dress the wire so that when the cover
is inserted into the chamber the wires do not exert excess
pressure on the terminal blocks. This is particularly important
when using cables with large cross sectional areas such as
2.5mm² and above.
The unit will be set as standard to 100V line. But can be easily
altered to 70V line by moving the red selection cable from the
100V line terminal to the 70V line terminal (see figure 4 for
position).
Figure 4
GNExL2 and GNExL1 70V and 100VLine Loudspeakers
Figur
e 3
Power Setting
Terminals A - E
70/100V Line
SettingTerminal

GNExL2 and GNExL1 8 ohm and 16 ohm low impedance
loudspeakers have dual input terminals on the pcb assembly
for input and output wiring. A cable of up to 2.5mm² can be
connected to each terminal. If dc line monitoring is used cut
the link on the board (see figure 5 and section 14 of this
manual).
14) End of Line DC Monitoring
OnGNExL2 and GNExL1 loudspeakers, dc line monitoring can
be used if required. Both the 70V and 100V Line units and the
Low Impedance units have blocking capacitors fitted. It should
be noted that each loudspeaker has a 1M ohm bleed resistor
connected across the blocking capacitor and this should be
taken into account when selecting the value of the end of line
monitoring resistance.
The end of line monitoring resistor can be connected across
the terminals on the end of line unit. On the low impedance
units care must be taken with the polarity of the monitoring
voltage.
On 100V and 70V line units the end of line resistor used must
have a minimum resistance value of 4k7 ohms and a minimum
wattage of 2.5 watts
On low impedance units the end of line resistor used must
have a minimum resistance value of 2k ohms and a minimum
wattage of 0.5 watts or a minimum resistance value of 500
ohms and a minimum wattage of 2 watts. On the low
impedance units care must be taken with the polarity of the
monitoring voltage. If an end of line resistor is fitted to a unit
the links on the printed circuit boards of all loudspeakers in the
line must be cutfor the dc blocking capacitors to be in circuitin
order todc monitor the line (see figure 5).
Figure 5
GNExL2 and GNExL1 8 ohm and 16 ohm Loudspeakers
-
-
++
Link
This manual suits for next models