EAE SW104 User manual

Order%Number:%48002%
!
EAE!KNX!Switch!Actuator!
Product!Manual!SW104!and!SW108!
!
!
!
!
!
!
!
%
%

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!1!/!22!
Content&
1! General!............................................................................................................................................!2!
2! Device!Technology!..........................................................................................................................!3!
2.1!Connection!Diagram!................................................................................................................!3!
2.2!Technical!Data!.........................................................................................................................!5!
3! Communication!Object!Table!..........................................................................................................!6!
4! Parameters!......................................................................................................................................!7!
4.1!Main!General!...........................................................................................................................!7!
4.2!Scene!.....................................................................................................................................!10!
4.3!Channel!General!....................................................................................................................!11!
4.4!Function!.................................................................................................................................!13!
4.4.1!Staircase!Function!.........................................................................................................!14!
4.4.2!External!Logic!Function!.................................................................................................!16!
4.4.3!Internal!Logic!Function!..................................................................................................!17!
4.4.4!Priority!Function!............................................................................................................!17!
4.4.5!Threshold!Function!........................................................................................................!18!
4.4.6! Operating!Hour!Function!...............................................................................................!20!
4.4.7!Sweep!Function!.............................................................................................................!21!
5! Process!Priority!Table!....................................................................................................................!22!
!
! !

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!2!/!22!
1 General&&
EAE!KNX!Switch!Actuator!has!eight!channels!which!can!be!configured!with!ETS3/ETS4!or!higher!
version.!Each!channel!is!independent!of!another.!It!has!a!separate!bistable!switching!relay.!SW108!/!
SW104!has!been!designed!especially!for!loads!with!high!surge!currents.!It!has!16A/20AX!(C-Load)!
relays!inside!channels.!C-Load!feature!enables!a!convenient!control!of!fluorescent!lambs.!Also!device!
has!a!manual!operating!feature.!The!relay!can!be!switched!on!or!off!with!slide!switches.!!
!
The!following!function!list!provides;!
• Staircase!
• External!logic!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
• Internal!logic!
• Priority!
• Threshold!
• Operating!hour!!
• Sweep!
Each!channel!of!devices!can!choose!any!of!these!functions.!The!outputs!are!parameterized!
individually!via!ETS3/4.!After!bus!voltage!failure!or!voltage!return!the!relay!position!is!selected!on!
dependence!on!the!parameterization.!In!“ETS!reset”,!device!parameters!are!return!download!
configuration.!!
NOTE:%Each%channel%is%uniform.%Device%factory%default%physical%address%is%15.15.255.!!
!
!
!
!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!3!/!22!
2 Device&Technology&
2.1 Connection&Diagram&
!
!
!"##$%&'"#()'*+,*-(

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!4!/!22!
!
!
1. Physical!Address!Label!
2. Programming!Button!
3. Red!Programming!LED!
4. KNX!Connection!Terminal!
5. Switch!Position!Display!and!ON/OFF!Manual!Actuation!
!
!
!
!
!
!
!
!
!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!5!/!22!
2.2 Technical&Data&
!
Type%of%protection%
IP!20!
EN!60!529!
Safety%class%
II!
EN!61!140!
Power%supply%:%
-!Voltage!
21V…!30V!DC,!SELV!
%
-!Current!consumption!!
!<!10!mA!
External%supply%
---!
!
Connections%
-!Screw!terminals!
!
-!Max!tightening!torque!
0,5…4!!mm²!solid!and!stranded!wire!!
0,5…2,5mm²!stranded!wire!with!ferrule!
0.8!Nm!
%
-!KNX!
Bus!connect!terminal!
Output%
-!Number!
4!output!–!SW104!
8!output!–!SW108!
%
-!Switching!voltage!!
277/440V!AC;!50/60!Hz!
%
-!Switching!capacity!277!V!AC!
16A!/!AC!1!
%
-!Fluorescent!lighting!load!to!EN!60!
669-1!
16!AX/250!VAC!
Output%life%
-!Mechanical!life!
>!3!x!106!
Type%of%contact%%
-!potential-free,!bistable!
!
Installation%
-!35mm!mounting!rail!
EN!60!715!
Operating%elements%
-!LED!(red)!and!button!
For!physical!address!
Temperature%range%
-!Ambient!
-5°!C!!!+!45°!C!
%
-!Storage!
-25°!C!!!+!55°!C!
%
-!Transport!
-25°!C!!!+!70°!C! !
Humidity%
-!max.!air!humidity!
95!%!no!moisture!condensation!
Dimensions%
SW108!-!65,5!x!143!x!89mm!
SW104!–!65,5!x!72!x!89!mm!
!
Weight%
SW108!0.45!kg!
SW104!0.15!kg!
!
Box%
Plastic,!polycarbonate,!colour!grey!
!
CE%
In!accordance!with!the!EMC!
guideline!and!low!voltage!
!
Application%program%
Communications!
objects!
Number!of!addresses(max)!
Number!of!
assignments(max)!
%
122!
253!
253!
!
NOTE:%Device!default!physical!address!is!15.15.255.!In!order!to!configure!switch!actuator,!ETS!
application!file!“.knxprod”!is!needed.!It’s!possible!to!download!the!file!on!EAE!website.!ETS!is!
required!for!programming!the!device.!Parameter!settings!and!related!group!addresses!can!be!
changed!by!ETS.!Learn!more!by!reading!ETS!help!file.!%
!
!
!
!
!
!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!6!/!22!
3 Communication&Object&Table&
The!following!122!communication!objects!are!available!in!the!SW108!and!SW104.!!
No%
Object%name%
Function%
DTP%Type%
Number%
of%bits%
Flags%
0!
General,!In!operation!
true!/!false!
DTP_Bool!1.002!
1!bit!
CWT!
1!
General!Scene!8-bit!
recall!/!save!
DPT_Scene!18.001!
1!byte!
CW!
2,!17,!32,!47,!
62,!77,!92,!107!
Output!1,!Switch!
on!/!off!
DPT_Switch!1.001!
1!bit!
CW!
3,!18,!33,!48!
63,!78,!93,!108!
Output!1,Status!Switch!
on!/!off!
DPT_Switch!1.001!
1!bit!
CRT!
4,!19,!34,!49,!
64,!79,!94,!109!
Output!1,Enable!staircase!
function!
enable!/!disable!
DPT_Enable!1.003!
1!bit!
CRW!
5,!20,!35,!50,!
65,!80,!95,!110!
Output!1,Staircase!lighting!
duration!
0h!…!65535h!
DPT_TimePeriodHrs!
7.007!
2!byte!
CRW!
6,!21,!36,!51,!
66,!81,!96,!111!
Output!1,Permanent!ON!
on!/!off!
DPT_Switch!1.001!
1!bit!
CW!
7,!22,!37,!52,!
67,!82,!97,!112!
Output!1,External!logic!
input!
on!/!off!
DPT_Switch!1.001!
1!bit!
CW!
8,!23,!38,!53,!
68,!83,!98,!113!
Output!1,Forced!positioning!
on!/!off!
DPT_Switch_Control!
2.001!
2!bit!
CW!
9,!24,!39,!54,!
69,!84,!99,!114!
Output!1,Start!value!of!
operating!hour!
0h!…!65535!hour!
DPT_TimePeriodHrs!
7.007!
2!byte!
CW!
Output!1,Limit!value!of!
operating!hour!
0h!…!65535!hour!
DPT_TimePeriodHrs!
7.007!
2!byte!
CW!
10,!25,!40,!55,!
70,!85,!100,!
115!
Output!1,Counter!reset!of!
opr.!hour!
No!action/reset!
trig!
DPT_Reset!1.015!
1!bit!
CW!
11,!26,!41,!56,!!
71,!86,!101,!
116!
Output!1,Current!value!of!
opr.!hour!
0h!…!65535h!
DPT_TimePeriodHrs!
7.007!
2!byte!
CR(T)!
12,!27,!42,!57,!
72,!87,!102,!
117!
Output!1,Operating!hour!
runout!
true!/!false!
DPT_Bool!1.002!
1!bit!!
CT!
13,!28,!43,!58,!
73,!88,!103,!
118!
Output!1,Threshold!input!
Value!0…65535!
DPT_Value_2Ucount!
7.001!
2!byte!
CW!
Output!1,Threshold!input!
Value!0…255!
DPT_Value_1Ucount!
5.010!
1!byte!
CW!
14,!29,!44,!59,!
74,!89,!104,!
119!
Output!1,Threshold!value!
Value!0…65535!
DPT_Value_2Ucount!
7.001!
2!byte!
CW!
Output!1,Threshold!value!
Value!0…255!
DPT_Value_1Ucount!
5.010!
1!byte!
CW!
15,!30,!45,!60,!
75,!90,!105,!
120!
Output!1,Threshold!status!
true!/!false!
DTP_Bool!1.002!
1!bit!
CRT!
16,!31,!46,!61,!
76,!91,!106,!
121!
Output!1,Sweep!
trigger!
DPT_Trigger!1.017!
1!bit!
CW!
!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!7!/!22!
4 Parameters&
4.1 Main&General&
!
(((((((((.$#$,*/(0*,*-$&$,1(
Enable'manual'Operation'
*yes'
((#"'
The!switch!actuator!can!be!switched!on!or!off!with!slide!switches.!This!parameter!determines!the!
position!of!relays!can!be!modified!manually!or!not.!
§ Set!the!parameter!to!“yes”.!
Each!relay!can!be!operated!manually.!!
§ Set!the!parameter!to!“no”.!
It!is!still!possible!to!change!relays!position!but!relay!return!its!old!position!in!a!maximum!of!
16!seconds.!
Device'alive'operation'active'
((2$1(
3no'
This!object!is!used!to!report!that!device!is!still!alive!and!connected!the!KNX!line.!Telegram!value!can!
be!selected!ON/OFF.!If!a!telegram!is!not!received,!device!may!be!defective!or!KNX!cable!can!be!
disconnected.!If!the!parameter!selected!yes;! !

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!8!/!22!
In'operation'value'
3send'value'‘0’(
((1$#4(5*/6$(789'
Telegram!data!can!be!selected.!
Operation'send'interval'[min]'''''''''''''''''''''''
8:315:;<<'
Here!the!time!interval!which!in!operation!communication!object!cyclically!sends!to!KNX!line.!
Activate'scene'
((2$1(
*no'
If!the!parameter!select!‘yes’,!scene!screen!open!on!the!main!window.!You!can!find!scene!information!
under!the!scene!function!title.!
Overwrite'threshold'value'with'download'
3yes(
''#"'
During!storage!of!a!threshold,!the!threshold!values!are!stored!permanently!in!the!device.!As!an!
alternative,!the!original!values!can!be!reloaded!into!the!device!during!each!programming!run!of!the!
ETS.!!
§ Set!the!parameter!to!“yes”!
User!threshold!values!store!in!the!device.!This!means!threshold!communication!object!will!be!
overwrite!threshold!values!but!ETS!download!can’t!write!on!it.!!
§ Set!the!parameter!to!“no”!
Threshold!values!stored!in!the!device!with!a!storage!function!will!be!maintained.!If!no!threshold!
values!have!been!stored,!the!threshold!values!last!programmed!in!the!ETS!remain!valid.!
Overwrite'scene'values'with'download'
3yes(
''#"'
During!storage!of!a!scene,!the!scene!values!are!stored!permanently!in!the!device.!As!an!alternative,!
the!original!values!can!be!reloaded!into!the!device!during!each!programming!run!of!the!ETS.!!
§ Set!the!parameter!to!“yes”!
Scenes!values!stored!in!the!device.!This!means!scene!communication!object!will!be!overwrite!
scene!values!but!ETS!download!can’t!write!on!it.!!
§ Set!the!parameter!to!“no”!
Scene!values!stored!in!the!device!with!a!storage!function!will!be!maintained.!If!no!scene!values!
have!been!stored,!the!scene!values!last!programmed!in!the!ETS!remain!valid.!
Overwrite'operating'hour'values'with'
download'
3yes(
''#"'
During!storage!of!an!operating!hour,!the!operating!hour!values!are!stored!permanently!in!the!device.!
As!an!alternative,!the!original!values!can!be!reloaded!into!the!device!during!each!programming!run!of!
the!ETS.!!
!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!9!/!22!
§ Set!the!parameter!to!“yes”!
Operating!hour!values!stored!in!the!device.!This!means!operating!hour!communication!object!
will!be!overwrite!operating!hour!values!but!ETS!download!can’t!write!on!it.!!
§ Set!the!parameter!to!“no”!
Operating!hour!values!stored!in!the!device!with!a!storage!function!will!be!maintained.!If!no!
operating!hour!values!have!been!stored,!the!operating!hour!values!last!programmed!in!the!ETS!
remain!valid.!
Transmission'delay'[2…255s]'after'bus'
voltage'recovery'
32:;<<(
'''
The!parameter!defines!the!behaviour!of!the!switch!actuator!at!a!bus!power!return.!The!transmission!
delay!time!determines!the!period!between!bus!voltage!recovery!and!the!point!after!which!telegrams!
can!be!sent.!
Telegram'limit'active'
((2$1(
3no'
Parameter!selects!“yes”;!
Telegram'limit'period'
50ms…*10s…1min%
The!limit!period!can!be!adjusted!via!this!parameter.!!
Max.'number'of'transmitted'telegrams'
within'a'period'
1…20…255%
Max!number!of!telegrams!per!period,!can!be!sent!freely.!
! !

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!10!/!22!
4.2 Scene&
!
((((((((((=%$#$(0*,*-$&$,1(
The!scene!function!of!the!switch!actuator!has!an!8!bit!scene!object.!It!is!possible!to!define!for!each!
64!scene!with!parameter!window.!8!independent!values!can!be!stored!for!each!relay.!The!scene!can!
be!specified!that!the!relay!‘open!contact’!(off),!‘close!contact’!(on)!or!‘keep!position’!its!state.!!
A!scene!is!activated!when!it!receives!its!scene!number!at!the!scene!object.!The!storing!of!the!current!
channel!values!is!carried!out!using!the!scene!object.!
For!example;!
Scene!
recall!
save!
Hex.!
Des.!
Hex.!
Des.!
1!
0x00!
0!
0x80!
128!
2!
0x01!
1!
0x81!
129!
3!
0x02!
2!
0x82!
130!
4!
0x03!
3!
0x83!
131!
5!
0x04!
4!
0x84!
132!
6!
0x05!
5!
0x85!
133!
7!
0x06!
6!
0x86!
134!
8!
0x07!
7!
0x87!
135!
9!
0x08!
8!
0x88!
136!
10!
0x09!
9!
0x89!
137!
11!
0x0A!
10!
0x8A!
138!
…!
…!
…!
…!
…!
63!
0x3E!
62!
0xE2!
190!
64!
0x3F!
63!
0xE3!
191!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!11!/!22!
!
4.3 Channel&General&&
!
((((((((((((!>*##$/(.$#$,*/(0*,*-$&$,1(
Contact'type'
((#",-*//2(%/"1$4(
*normally%open%
The!relays!of!a!switching!output!can!be!parameterized!as!normally!closed!or!normally!open.!This!
feature!offers!the!possibility!of!inversion!the!switching!state.!Important:!This!state!is!only!valid!for!
switch!communication!object.!Other!relay!function!always!works!normally.!!
Normally!closed!contact!
Switch!state!=!off!(0)!à!relay!contact!closed!!
Switch!state!=!on!(1)!à!relay!contact!open!
Normally!open!contact!
Switch!state!=!off!(0)!à!relay!contact!open!!
Switch!state!=!on!(1)!à!relay!contact!closed!
!!!
Send'switch'status'feedback'telegram'
((#"(
((*?&$,(%>*#+$(
((*?&$,(,$@6$1&(
*after%change%or%request%
The!switch!status!feedback!can!be!used!as!an!active!or!passive!communication!object.!Active!
message!object,!the!switch!status!telegram!is!transmitted!to!the!bus!automatically!when!a!relay!state!
changes.!Passive!status!object,!there!is!no!telegram!transmission!after!relay!state!changes.!!If!you!
want!to!learn!switch!status,!you!must!read!communication!object.!Communication!object!flags!are!
automatically!set!by!ETS.!!
NOTE:!Switching!state!changes!by!manual!operation!are!not!detected.!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!12!/!22!
Create'status'object'“Status'Switch”'
3yes(
!!no%
If!this!parameter!select!‘yes’,!ETS!create!another!communication!object!for!use!only!status!switch.!
The!status!object!can!be!used!to!display!the!current!output!switching!status!on!a!display.!
Send'status'after'bus'voltage'return'
((((2$1(
!!*no%
You!can!use!this!parameter!to!send!the!switching!state!in!the!event!of!bus!voltage!recovery.!!
Behaviour'after'ETS'program'
3keep'position(
(("A$#(%"#&*%&(
!!close!contact%
After!ETS!programming,!relay!position!set!the!wanted!switching!position.!!
§ Set!the!parameter!to!“keep!position”!
In!this!setting,!the!relay!remains!in!the!current!state.!Any!manual!operation!occurs!in!the!
meantime!the!switch!actuator!return!its!old!position.!The!device!doesn’t!know!the!status!of!the!
relay.!!
§ Set!the!parameter!to!“open!contact”!or!“close!contact”!
The!relay!contact!open!or!close!after!bus!voltage!return.!!
Behaviour'bus'voltage'failure'
3keep'position(
(("A$#(%"#&*%&(
!!close!contact%
When!the!bus!voltage!fails,!the!device!set!the!wanted!switching!state!of!the!output.!The!relay!can!be!
open,!close!or!keep!position!it!occupied!prior!to!the!failure.!At!the!same!time,!the!current!switching!
position!of!the!relay!is!stored!in!the!devices.!!
Behaviour'bus'voltage'return'
((B$$A(A"1'&'"#(
(("A$#(%"#&*%&(
((%/"1$(%"#&*%&(
*state%as%before%bus%voltage%failure%
When!the!bus!voltage!returns,!the!device!set!the!wanted!switching!state!of!the!output.!!
§ Set!the!parameter!to!“keep!position”!
In!this!setting,!the!relay!remains!in!the!current!state.!Any!manual!operation!occurs!in!the!
meantime!the!switch!actuator!return!its!old!position.!The!device!doesn’t!know!the!status!of!the!
relay.!!
§ Set!the!parameter!to!“open!contact”!or!“close!contact”!
The!relay!contact!open!or!close!after!bus!voltage!return.!!
§ Set!the!parameter!to!“state!as!before!bus!voltage!failure”!
If!the!parameter!set!to!“state!as!before!bus!voltage!failure”,!then!the!relay!is!set!to!the!value.!
The!value!stored!at!the!time!of!the!bus!voltage!failure.!!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!13!/!22!
!
4.4 Function&
!
((((C6#%&'"#(0*,*-$&$,1(
Above!function!parameters!can!be!set!for!each!channel.!These!functions;!
!
I. Staircase!
II. External!logic!
III. Internal!logic!
IV. Priority!
V. Threshold!
VI. Operating!hour!
VII. Sweep!
Please!find!description!of!these!functions!below.!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!14!/!22!
4.4.1 Staircase&Function&
!
(((((((=&*',%*1$(C6#%&'"#(0*,*-$&$,1(
In!order!to!use!staircase!function,!‘Staircase’!should!be!enabled!on!the!function!window.!Than!
required!parameters!and!communication!objects!will!be!visible.!The!staircase!function!can!be!
parameterized!for!each!channel.!!
Staircase!function!has!got!a!three!communication!object.!These!are!“Enable!staircase!function”,!
“Staircase!lighting!duration”!and!“Permanent!ON”.!
Duration'of'staircase'lighting'[min]/'[sec]'
D:35:;EDF-'#G(
30:<H((((((((F1$%G'
Staircase!function!on!time!is!calculated!by!“duration!of!staircase!lighting”.!Staircase!lighting!time!is!
defined!by!this!parameter.!At!the!end!of!the!on!time,!the!relay!off!or!active!the!staircase!warning!
functions.!
'Staircase'retrigger'
3not'retriggerable'
((2$1(,$&,'++$,*I/$(
((6A(&"(1&*',%*1$(/'+>&'#+(&'-$(;J(
((6A(&"(1&*',%*1$(/'+>&'#+(&'-$(KJ(
((6A(&"(1&*',%*1$(/'+>&'#+(&'-$(EJ(
((6A(&"(1&*',%*1$(/'+>&'#+(&'-$(<J'
This!parameter!defines!whether!the!staircase!on!time!can!be!retrigger!able!or!not!so!the!on!time!can!
be!extended!by!‘Enable!staircase!function’.!You!can!repeat!retrigger!function!until!the!repeater!count!
reached!the!maximum!value!(2x,!3x,!4x,!5x).!!If!the!parameter!selects!‘not!retriggerable’,!staircase!on!
time!doesn’t!extend.!!
Reaction'to'OFF'telegram'
3switch'off'
((L+#",$'
After!this!parameter!selected!‘switching!off’,!ignored!‘Enable!staircase!function’!communication!
object!‘disable’!command.!!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!15!/!22!
Staircase'time'can'be'changed'by'object'
((2$1(
3no'
‘Staircase!lighting!duration’!communication!object!is!visible!if!a!‘Staircase!time!can!be!changed!by!
object’!parameter!selects!‘yes’.!This!communication!object!is!2!byte.!The!value!defines!the!staircase!
on!time!in!second.!!
NOTE:!After!a!bus!voltage!fails,!staircase!on!time!returns!default!value!(Duration!of!staircase!lighting).!
Restart'staircase'after'“Permanent'ON”'
((2$1(
3no'
If!this!parameter!is!selected!‘yes’,!receive!‘Permanent!ON’!communication!object!after!restart!
staircase!function.!!
Activate'pre-warning'time?'
((2$1(
3no'
The!warning!function!can!be!activated!by!this!parameter!select!‘yes’.!Then,!you!can!adjust!pre-
warning!time,!number!of!pre-warning!and!time!for!pre-warning!interval.!The!warning!function!is!for!
warning!that!the!staircase!lighting!time!run!out!and!the!lights!are!switched!off!soon.!In!the!warning,!
lights!short!turn!off.!Switch!status!is!ON!until!finish!warning!time.!!
Pre-warning'time'Minutes'(0…59)'
Second'(0…59)'
3D:<H'
!!D:330:<H'
How!long!the!lights!shall!be!switched!on!in!the!period.!!
Number'of'pre-warning'(1…10)'
8:32:8D'
%
Enter!the!number!of!how!many!blink!doing!in!the!warning.!!
Time'for'pre-warning'intervals''
Seconds'(0…59)'
D:33:<H'
%
How!long!the!lights!shall!be!switched!off!in!the!period.!
Activate'on'delay'
((2$1(
3no'
This!parameter!is!used!to!delay!switch!off!position!before!staircase!start.!!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!16!/!22!
4.4.2 External&Logic&Function&
!
MJ&$,#*/(N"+'%(0*,*-$&$,1(
Logic!function!can!be!used!independently!for!each!output.!With!this!function,!the!‘Switch’!object!can!
be!logically!linked!with!the!‘External!logic!input’.!Channel!relay!switch!a!result!of!the!logic!operation.!
For!example!‘Switch’!object!value!1!and!‘External!logic!input’!object!value!0!relay!switch!as!a!result!of!
1!&!0!operation.!!
External'logic'function'type'
((3AND(
((((OP(
((((QOP'
This!parameter!selects!the!type!of!logic!function!between!‘Switch’!and!‘External!logic!input’!objects.!!
Invert'result'
((2$1(
3no'
If!you!want!to!inverted!logic!function!result,!you!should!select!‘yes’.!
Logic'object'value'after'bus'voltage'return'
(((R8S(
3”0”'
This!parameter!defines!the!value!of!the!‘External!logic!input’!object!after!bus!voltage!return.!!
NOTE:!The!values!of!the!‘External!logic’!communication!objects!doesn’t!store!at!the!bus!voltage!
failure.!
! !

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!17!/!22!
4.4.3 Internal&Logic&Function&
!
L#&$,#*/(N"+'%(0*,*-$&$,1(
You!can!enter!the!opening!or!closing!scenario!of!the!channel.!In!this!function,!each!relay!can!be!
switched!only!one!time!because!this!reaction!protects!the!devices!from!infinite!loop.!An!internal!logic!
function!can!be!parameterized!separately!for!each!output.!The!relay!of!the!channel!doesn’t!
participate!to!the!scenario.!
Relay'1…8'state'
3don’t'care(
(("??(
''on'
To!create!scenario!to!open!or!close!channel!relay,!positions!of!other!channels!of!the!switch!actuator!
are!set!with!these!parameters.!The!channels!that!doesn’t!need!to!participate!this!scenario!should!be!
left!don’t!care.!
!
4.4.4 Priority&Function&
If!the!priority!function!is!enabled,!‘Forced!positioning’!communication!object!is!visible.!It!hasn’t!got!
any!parameter.!This!is!the!standard!forced!position!working.!!
Bit!1!!
Bit!0!
Function!
0!
0!
forced!positioning!not!active!–!normal!control!
0!
1!
forced!positioning!not!active!–!normal!control!
1!
0!
Forced!positioning!active!–!switch!off!
1!
1!
Forced!positioning!active!–!switch!on!
!
!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!18!/!22!
4.4.5 Threshold&Function&
!
(((T>,$1>"/4(0*,*-$&$,1(
The!function!can!be!configured!1!byte!or!2!byte.!The!value!of!Threshold!input!communication!object!
falls!below!or!exceeds!a!limit!of!threshold!value.!Then!the!relay!position!can!be!changed!by!this!way.!!
Object'size'
31'byte(
((;(I2&$'
The!threshold!value!function!data!type!determined!here.!All!of!the!parameters!associated!with!it!
which!will!change.!!
Threshold'value'
D:*128:;<<((((((((((U?",(8(I2&$V(
D:*20000:W<<K<(U?",(;(I2&$V'
Threshold!limit!value!enters!here.!This!parameter!is!dependent!‘Object!size’!parameter.!
Threshold'reaction'
*OFF'(0)'below'threshold,'ON'(1)'above'threshold'
((OX(U8V(I$/"Y(&>,$1>"/4Z(OCC(UDV(*I"5$(&>,$1>"/4'
This!parameter!determines!the!switch!state.!If!the!value!of!the!‘Threshold!input’!communication!
object!value!bellows!or!above!the!threshold!limit!value,!the!relay!switched!on!or!off!position.!!
Threshold'value'can'be'changed''
by'object'
''2$1'
3no'
If!the!parameter!selects!‘yes’,!‘Threshold!value’!communication!object!is!visible.!Threshold!value!can!
be!changed!by!this!object.!!
Threshold'hysteresis'
''2$1'
3no'
Hysteresis!is!dependence!of!a!system!not!only!its!current!value!but!also!on!its!past!value.!!
If!the!parameter!selects!‘yes’;!
!

Product Manual SW108 and SW104
EAE KNX Switch Actuator PM R2.0
!
©EAE!Technology!! ! ! www.eaetechnology.com!! ! ! Page!19!/!22!
Hysteresis'percentage'(1…10)'
[8:3%5:[88'
'
!
For!example:!Hysteresis!percentage!parameter!selected!%10.!You!can!see!this!state!below!graphic.!
Threshold!hysteresis!value!measure!formula!100!*!10!/!100!=!10!and!threshold!high!and!low!limit!100!
+-!10.!
!
(T>,$1>"/4(.,*A>'%(
!
This manual suits for next models
1
Table of contents
Other EAE Controllers manuals
Popular Controllers manuals by other brands

SANKI
SANKI P212-F instruction manual

Demasled
Demasled GSM-L10 user manual

SWARCO
SWARCO McCain Omni eX quick start guide

Isimet
Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

Honeywell
Honeywell HC900 installation and replacement

EuroLite
EuroLite TP-310 user manual