manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eaton
  6. •
  7. Work Light
  8. •
  9. Eaton AtLite SELDWTA29SD Series User manual

Eaton AtLite SELDWTA29SD Series User manual

Sure-Lites
AtLite
Installation Instructions for the Sure-Lites
SELDWTA29SD/SELDWA50SD/
ATLELDWTA100SD/ATLELDWA300SD series
Emergency Light with Self Diagnostics
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be observed including the following:
•READ AND FOLLOW ALL SAFETY INSTRUCTIONS
•Do not use in hazardous locations, or near gas or electric
heaters.
•Do not let power supply cords touch hot surfaces.
•Use caution when servicing batteries. Battery acid can
cause burns to skin and eyes. If acid is spilled on skin or in
eyes, flush acid with fresh water and contact a physician
immediately.
•Do not use this equipment for other than the intended use.
•Installation is to be performed only by qualified personnel.
•Install in accordance with National Electric Code and local
regulatory agency requirements.
•The use of accessory equipment not recommended by the
manufacturer may cause an unsafe condition.
•Equipment should be mounted in locations and at heights
where it will not readily be subjected to tampering by un-
authorized personnel.
•SAVE THESE INSTRUCTIONS
Maximum Mounting Height for SELDWTA29SD series: 8.6 ft.
Maximum Mounting Height for SELDWA50SD series: 18.8 ft.
INSTALLATION
1. De-energize the circuit at the junction box (J-box) where
the emergency light is to be installed.
2. Open the emergency light by inserting a flat screwdriver in
the two slots on the side of the unit, then turning to sepa-
rate housing from the backplate.
3. To mount to a junction box - Knock out/drill out the appropriate
mounting pattern and the wire pass hole in the backplate
and the back gasket to fit the J-box being used.
4. To mount to conduit – Unscrew the ½” NPT plug located
at the top of the fixture and screw in the user-supplied
conduit hub.
5. Once the backplate is secured, the housing can be held
in place during installation with the help of the grounding wire
(see Fig. 1 next page).
6. Connect the incoming wires to the SELDWTA29SD/
SELDWA50SD/ATLELDWTA100SD/ATLELDWA300SD series
power supply wires using the wire nuts provided. Connect the
green grounding wire for the housing. Connect the white wire to
neutral. If using 120V, connect the black wire to the hot lead. If
using 277V, connect the orange wire to the hot lead. Cap the
unused lead. Secure the emergency light to the wall and/or
junction box using installer supplied hardware.
7. Complete the battery connection and snap the cover onto
the backplate.
8. Energize AC supply. The test button should illuminate, and
LED heads will illuminate briefly when the test button is
pushed.
9. Adjust the heads as needed. The SELDWTA29SD/
SELDWA50SD/ATLELDWTA100SD/ATLELDWA300SD series
lenses utilize a highly directional beam, and the lenses can be
rotated to adjust the beams to the front or sides of the fixture
(see Fig. 2 next page).
WARNING
Risk of Fire / Electric Shock
If not qualified, consult an electrician.
WARNING
Risk of Electric Shock
Disconnect power at fuse or circuit breaker before installing
or servicing.
OPERATION
The Sure-Lites Eagle Eye Self Diagnostics is continuously
monitoring your emergency fixture, and will signal any
failure through the 3 color indicator LED.
INITIAL OPERATION
When the unit is first powered up, it will go into a 24 hour
fast charge, indicated by the indicator LED pulsing green.
Once the unit has fully charged, it will perform a self calibration,
after which the LED will change to steady green,
indicating the unit is fully charged and float charging the
battery to maintain readiness.
AUTOMATIC TESTING
The unit will perform a battery capacity, lamp/LED, and
charge circuit test every 30 days for 30 seconds. During
this time, the indicator LED will change to a steady yellow.
It will perform a full battery capacity (90 minute) test once
per year. During this time, the indicator LED will change to
a blinking yellow.
MANUAL TESTING
•10 Second “Installation” test – Press and release the
test button once during fast charge (blinking green) to
initiate a 10 second quick test. The sign will switch to
emergency mode for 10 seconds allowing the installer
to verify proper installation of the unit, and the LED
indicator will turn solid yellow.
•30 Second Test - Press and release the test button once
during float charge (steady green). The indicator LED will
turn steady yellow to indicate the unit is performing a 30
second test of the batteries and lamps/LEDs.
•90 Minute Test - Press and release the test button a
second time during a 30 second test (steady yellow) to
change to a 90 minute test. During this test, the LED indi-
cator will change to blinking yellow, and the circuit will per-
form a full battery capacity, charge circuit, and LED test.
•Cancelling Test – Press and release the test button
during the 90 minute test (flashing yellow) to return the
fixture to its original state (fast charge or float charge).
LASER TEST
The
SELDWTA29SD/SELDWA50SD/ATLELDWTA100SD/
ATLELDWA300SD series
is equipped with a Laser Test
function, that allows the unit to be manually tested without
the need to physically press the test button. Shining a laser
pointer in the hole marked “LASER TEST” on the bottom of
the unit has the same effect as a press and release of the
test button.
CLEARING FAILURE CODES
•A battery failure (LED two blink red) can be cleared by
replacing the battery. Disconnecting the battery and AC
power, or performing a full 90 minute discharge, will reset
the error code, however, it will return if the battery is faulty.
•Charge Circuit (LED three blink red) and lamp/LED failure
(LED four blink red) will clear when the unit successfully
passes a manual or automatic 30 second test.
INDICATORS
LED Off - No power to unit, emergency mode.
LED Steady Green - Unit is fully charged and is float charging
the battery to maintain readiness.
LED Green Pulse - Unit is in a 24 hour fast charge of the bat-
tery.
LED Two Blink Red - Battery has failed a capacity test, or the
battery is disconnected. See “Clearing Failure Codes” above.
LED Three Blink Red - Battery charge circuit has failed. See
“Clearing Failure Codes” above.
LED Four Blink Red - Lamps have burned out, or on an EXIT/
Combo, 50% or more of the LEDs have failed. See “Clearing
Failure Codes” above.
LED Steady Yellow - 30 second test or 10 second quick test
(Fast Charge only).
LED Blinking Yellow - 90 minute test
MAINTENANCE
None required. Replace the batteries as needed according
to ambient conditions. Equipment should be tested every
30 days in accordance with local codes.
NOTE: Servicing of any parts should be performed by qualifi
ed personnel. Only use replacement parts supplied by Eaton
Lighting. Use of unauthorized parts may void the warranty.
CAUTION: This equipment is furnished with a sophisticated
low voltage battery disconnect to protect the battery
from over discharge after its useful output has been used.
Allow 24 hours recharge time after installation or power
failure prior to 90 minute testing.
TROUBLE SHOOTING GUIDE
1. If LED heads or charge indicator LED does not illuminate,
check the following:
2. Check AC supply – verify that unit has 24 hour AC supply.
3. Unit is shorted or battery is not connected.
4. Battery discharged. Permit unit to charge for 24 hours and
then re-test.
5. If following the above trouble shooting hints does not solve
your problem, contact your local Eaton Lighting represen-
tative for assistance
SELDWA50SD/ATLELDWA300SD SELDWTA29SD/ATLELDWTA100SD
The SELDWTA29SD/SELDWA50SD/ATLELDWTA100SD/ATLELDWA300SD series
Green(Grounding wire) Green(Grounding wire)
SCHEMATIC
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
eaton.com/lighting
© 2015 Eaton
All Rights Reserved
Printed in USA
Eaton is a registered trademark.
All trademarks are property of
their respective owners
SELDWA50SD/ATLELDWA300SD
SELDWTA29SD/ATLELDWTA100SD
LED DRIVER
LED DRIVER

This manual suits for next models

3

Other Eaton Work Light manuals

Eaton HALO HU2012PS2P930MBR User manual

Eaton

Eaton HALO HU2012PS2P930MBR User manual

Eaton Cooper Lighting Might D Light LED140 User manual

Eaton

Eaton Cooper Lighting Might D Light LED140 User manual

Eaton ALL-PRO WL2540LP User manual

Eaton

Eaton ALL-PRO WL2540LP User manual

Eaton CEAG Style Variant 29011 Service manual

Eaton

Eaton CEAG Style Variant 29011 Service manual

Eaton CEAG W 276.3 LED Service manual

Eaton

Eaton CEAG W 276.3 LED Service manual

Eaton Might-D-Light Mini LED125B User manual

Eaton

Eaton Might-D-Light Mini LED125B User manual

Eaton ALL-PRO WL2540LST User manual

Eaton

Eaton ALL-PRO WL2540LST User manual

Eaton Exit Cube Service manual

Eaton

Eaton Exit Cube Service manual

Eaton Metalux 14SP4240RT User manual

Eaton

Eaton Metalux 14SP4240RT User manual

Eaton PXLED User manual

Eaton

Eaton PXLED User manual

Eaton Sure-Lites ADX142857 User manual

Eaton

Eaton Sure-Lites ADX142857 User manual

Popular Work Light manuals by other brands

Grote 79100 installation guide

Grote

Grote 79100 installation guide

Schumacher Electric SL28B manual

Schumacher Electric

Schumacher Electric SL28B manual

LUMEN CENTER ITALIA TRYLON LED Assembly istructions

LUMEN CENTER ITALIA

LUMEN CENTER ITALIA TRYLON LED Assembly istructions

Philips LivingColors 6917167PH brochure

Philips

Philips LivingColors 6917167PH brochure

Seto RP110 LED ___ DIM instructions

Seto

Seto RP110 LED ___ DIM instructions

Westinghouse 63156 instruction manual

Westinghouse

Westinghouse 63156 instruction manual

Spectro-UV SPECTROLINE uVision Series manual

Spectro-UV

Spectro-UV SPECTROLINE uVision Series manual

Philips LivingColors 6914748PH brochure

Philips

Philips LivingColors 6914748PH brochure

Matco Tools MWLCR4 instruction manual

Matco Tools

Matco Tools MWLCR4 instruction manual

BGS technic 85353 instruction manual

BGS technic

BGS technic 85353 instruction manual

kobi SOLAR LED CLAVO manual

kobi

kobi SOLAR LED CLAVO manual

Worx WU024 manual

Worx

Worx WU024 manual

Bayco SL-1514 instruction manual

Bayco

Bayco SL-1514 instruction manual

EINHELL TE-CL 18/2000 LiAC Original operating instructions

EINHELL

EINHELL TE-CL 18/2000 LiAC Original operating instructions

UNILITE HT-450 quick start guide

UNILITE

UNILITE HT-450 quick start guide

Saber Compact ATD-80477 owner's manual

Saber Compact

Saber Compact ATD-80477 owner's manual

Allen + Roth SLL10JJ manual

Allen + Roth

Allen + Roth SLL10JJ manual

RUSTA 77260017 manual

RUSTA

RUSTA 77260017 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.