manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EBS
  6. •
  7. Marine Equipment
  8. •
  9. EBS M7000 User manual

EBS M7000 User manual

This manual suits for next models

1

Popular Marine Equipment manuals by other brands

POWERWINCH 825 Operation manual

POWERWINCH

POWERWINCH 825 Operation manual

JRC JLN-628 brochure

JRC

JRC JLN-628 brochure

DIGITAL YACHT PilotLink2 Product handbook

DIGITAL YACHT

DIGITAL YACHT PilotLink2 Product handbook

Clarion CMS2 Owner's manual & installation manual

Clarion

Clarion CMS2 Owner's manual & installation manual

Kongsberg M3 Bathy installation manual

Kongsberg

Kongsberg M3 Bathy installation manual

NPK SCS-1002 operating manual

NPK

NPK SCS-1002 operating manual

Furuno FE-800 installation manual

Furuno

Furuno FE-800 installation manual

Harken 1561 instructions

Harken

Harken 1561 instructions

Simrad DD15 manual

Simrad

Simrad DD15 manual

Notifier FS-BSO Installation and maintenance instructions

Notifier

Notifier FS-BSO Installation and maintenance instructions

Raymarine ST40 Quick reference guide

Raymarine

Raymarine ST40 Quick reference guide

Raymarine Maxiview ST80 Owner's handbook

Raymarine

Raymarine Maxiview ST80 Owner's handbook

E2S E2XS112UL Instructions/service manual

E2S

E2S E2XS112UL Instructions/service manual

GUIDANCE MARINE 20- Series Installer's guide

GUIDANCE MARINE

GUIDANCE MARINE 20- Series Installer's guide

R2Sonic 2026 Operation manual

R2Sonic

R2Sonic 2026 Operation manual

COBHAM SAILOR 6000 installation manual

COBHAM

COBHAM SAILOR 6000 installation manual

Raymarine ST60 Tridata Owner's handbook

Raymarine

Raymarine ST60 Tridata Owner's handbook

Furuno Navtex NX-700-A Operator's manual

Furuno

Furuno Navtex NX-700-A Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

M7000
BM7000
Installation manual
(piezo version only)
M7000 acoustic & flash sounder
PIEZOELECTRIC, OUTDOOR, WITHOUT BACK-UP
FOR 12 V INTRUSION SYSTEMS
BM7000 acoustic & flash sounder
PIEZOELECTRIC, OUTDOOR, WITH BACK-UP
FOR 12 V INTRUSION SYSTEMS
We are very thankful that you have chosen our new sounder.
Its beautiful and unique shape will distinguish your installations. And it helps you to
install the sounder straight…
There are two models: piezoelectric and dynamic. This manual refers to the piezoelectric one.
The sounder needs 0,5 Amps approximately when in action. Please check if the intrusion panel can give it.
It is recommended to install the sounder:
¾Close to the panel to avoid significant voltage drops on wires,
¾High enough to make the sounder difficult to reach.
Installation
Before you take the ladder…
1. Unscrew the central mounting screw and remove the cover.
2. Selection of acoustic tone
You can select one of three tones using a jumper marked S1/S2/S3. Default is S1. This is the loudest tone as well. No
jumper is the same as S1.
To listen to the tones:
¾Connect power (0V = GND, +13,8V),
¾Give 0V (GND) to the S input for several seconds,
¾Repeat with all S1/S2/S3 positions.
This is a test method only! Do not use it during a normal operation!
3. Selection of controls
Think it over carefully! To select the control you have to cut a jumper(s).
This is a reliable method resistant to all weather conditions but the undo function is difficult…
To switch the tone (or lamp) on you can give positive signal (nominal value is +12V) or negative one (0V = GND) or
remove such signals.
You have two control inputs for siren and lamp separately. You can use different signals or the same ones. You
can short circuit the inputs or leave them separately.
To select the control signal for the siren… Cut the jumper(s)
Active state: + 12V - control signal + 12V gives the tone
Non active states: 0V (GND) or high impedance (break) JS1 and S
Active states: lack of + 12V (break or 0V)
Non active state: + 12V *- control signal + 12V blocks JS1
Active state: 0V (GND) - control signal 0V gives the tone
Non active states: + 12V *or high impedance (break) JS2
Active states: lack of 0V (break or + 12V)
Non active state: 0V (GND) - control signal 0V blocks JS2 and S
*It is a good idea to use positive signal as non-active one. You can easily monitor the line in such mode. The 4,7 k
Ω
resistor is installed as EOL in the sounder. If your control panel needs smaller EOL you can add a resistor between S and
GND inputs. The formula to calculate it is as follows:
4,7 x EOL
R = ----------------------
4,7 - EOL
R is the value of additional resistor (in k
Ω
) to add.
EOL is the value your panel expects (in k
Ω
).
To select the control signal for the lamp… cut the jumper(s)
All options as above for the siren. Notes referring
to line monitoring are the same.
as above, but jumpers are
marked L, JL1 and JL2
On the ladder...
The sounder is equipped with one lamp, which should look down.
4. Position the sounder on the wall. The cables should go thru the hole on the left side of the sounder. Mark the place of the upper
mounting screw.
5. Drill the hole 12 mm dia. for upper mounting screw. Insert the plastic plug (delivered with the sounder). Mount the sounder.
6. Position the sounder. Mark 3 remaining holes.
7. Drill the holes, insert the plugs, mount the sounder firmly.
8. Connections
In the table below you can see the description of the connector of the sounder.
SL GND +13,8 SAB (2 terminals) R (2 terminals)
siren control
signal
lamp control
signal
ground
(supply
negative)
supply
positive
sabotage line (tamper),
polarity not important
EOL of sabotage
line
Connect:
¾first EOL of sabotage line
¾then sabotage line,
¾controls,
¾Power supply.
9. Fit the cover.
Main technical parameters
Power supply (nominal 13,8V) 9 – 15V
Current consumption (at 13,8V)
Quiescent
Alarm (acoustic only)
Alarm (optical only)
Alarm (acoustic and optical)
10 mA
200 mA
400 mA
600 mA
Control input current +/-3 mA
Connectors with screws
Weather protection of the pcb special resin
Acoustic signal piezoelectric driver
Tone choosing jumper, 1 of 3
Tone 1 117 dB, at 1 m
Tone 2 116,5 dB, at 1 m
Tone 3 116 dB, at 1 m
Optical signal 4 Philips mini bulbs, 12V, 5W
Time of the flash 0,25 s
Frequency of the flashes 1 Hz
Colour red
Protections Tamper line with EOL according to panel
specification
Detection of foam
Detection of opening the housing
Detection of pulling the sounder from the wall
Housing Polycarbonate
Diameter 24 cm
Environmental conditions
Operating temperature -25
÷
+ 70 deg. C
Storage temperature -25
÷
+ 70 deg. C
Humidity 100%