AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL#: 6.5GB-ILP Maximum Input Rang
(Btu per hour): 170,000
SERIAL#: Minimum Input Rang
(Btu per hour): 17,000
GAS TYPE: LIQUID
PROPANE ONLY Minimum Inlet Gas
Pressure:
8.0” W.C.
(1.99 kPa)
VOLTAGE: 120 Volts Maximum Inlet Gas
Pressure:
13’’ W.C.
(3.23 kPa)
FREQUENCY: 60 Hz Manifold Pressure: 6.67” W.C.
(1.66 kPa)
AMPS: Less than 10 Amperes Maximum Working
Pressure: 150 PSI
RECOVERY RATING:
As used in this standard, the quantity of water obtained by multiplying the manufacturer’s input
rating in Btu per hour by thermal efficiency and dividing the product by 8.25 Btu per gallon. This is
based on a 100°F (37.8°C) temperature rise, and a nominal specific heat for water of 8.25 Btu per
gallon per degree F.
Not recommended in excess of 2,000 ft. Above sea level Category III Type B Water Heater
CANADIAN HIGH ALTITUDE RATING
Altude 0-2000 feet
Input (btu/hr) 170,000
Manifold pressure (in. W.C.) 6.67
CSA/ANSI 221.10.3 CSA 4.3-2021 SUITABLE FOR WATER (POTABLE) HEATING ONLY
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance
This appliance must be installed in accordance with local codes
or, in the absence of local codes, the Naonal Fuel Gas Code,
ANSI Z223.1/NFPA 54 or the CSA B149.1, Natural Gas and
Propane Installaon Code
The unit must be installed on a fire-retardant area and must be away from all combustible materials. Clearance should be 10in to
the left and right side of combustible materials, 16 in. above, 12 in. above the floor, and 6 in. to the front.
This water heater requires a special venting system. Refer to the installation instructions for parts list and methods of installation.
The temperature and pressure relief valve provided by the manufacturer shall be installed at the time of installation of the heater in
the location specified by the manufacturer. Local codes shall govern the installation of relief devices. For safe operation of the
water heater, the relief valve must not be removed or plugged
INDOOR USE ONLY
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
CHAUFFE-EAU INSTANTANÉ AUTOMATIQUE
MODÈLE # : 6.5GB-ILP Puissance Maximum
d’Entrée 170,000
SÉRIE # : Puissance Minimum
d’Entrée 17,000
TYPE DE GAZ : PROPANE
LIQUIDE SEULEMENT Pression minimale
d’arrivée de gaz
8.0” W.C.
(1.99 kPa)
Tension : 120 Volts Pression maximale
d’arrivée de gaz
13’’ W.C.
(3.23 kPa)
Fréquence : 60 Hz Pression d’admission 6.67” W.C.
(1.32 kPa)
Ampères : Moins de 10 Ampères Pression de travail
maximale 150 PSI
Note de Récupéraon:
Telle qu'utilisée dans la présente norme, la quantité d'eau obtenue en multipliant l'indice
d'apport du fabricant en Btu par heure par l'efficacité thermique et en divisant le produit
par 8,25 Btu par gallon. Ceci est basé sur une augmentation de température de 100°F
(37,8 ° C) et une chaleur spécifique nominale pour l'eau de 8,25 Btu par gallon par degré F.
Non recommandé à plus de 2000 pieds au-dessus du niveau de la mer. Chauffe-eau De Catégorie III Type B
CANADIENNE ALTITUDE NOTE HAUT
Altude 0-2000 feet
Input (btu/hr) 170,000
Manifold pressure (in. W.C.) 6.67
CSA/ANSI 221.10.3 CSA 4.3-2021 ADAPTÉ À L’EAU (POTABLE) CHAUFFAGE SEUL
POUR VOTRE SÉCURITÉ
Ne pas entreposer ou uliser de l’essence ou d’autres
vapeurs et liquides inflammables à proximité de cet
appareil ou de tout autre appareil
Cet appareil doit être installé conformément aux codes
locaux ou , en l’absence de codes locaux , le Naonal Fuel
Gas Code , ANSI Z223.1 / NFPA 54 ou le CSA B149.1 , gaz
naturel et propane Code d’installaon
L'unité doit être installée sur une surface ignifuge et doit être éloignée de toutematière combustible. Le dégagement doit être de 10
po à gauche et à droite des matériaux combustibles, de 16 po au-dessus, de 12 po au-dessus du plancher et de 6 po à l'avant.
Ce chauffe-eau nécessite un système de ventilation spécial. Reportez-vous aux instructions d'installation pour la liste des
pièces et les méthodes d'installation.
La soupape de décharge de température et de pression fournie par le fabricant doit être installée au moment de l'installa on de
l'appareil de chauffage à l'emplacement spécifié par le fabricant. Les codes locaux doivent régir l'installa on des disposi fs de
décharge. Pour un fonc onnement sécuritaire du chauffe-eau, la soupape de décharge ne doit pas être enlevée ou bouchée.
UTILISATION À L'INTÉRIEUR SEULEMENT
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL#: 6.5GB-ING Maximum Input Rang
(Btu per hour): 170,000
SERIAL#: Minimum Input Rang
(Btu per hour): 17,000
GAS TYPE: NATURAL GAS ONLY Minimum Inlet Gas
Pressure:
3.5” W.C.
(.87 kPa)
VOLTAGE: 120 Volts Maximum Inlet Gas
Pressure:
10.5” W.C.
(2.61 kPa)
FREQUENCY: 60 Hz Manifold Pressure: 3.05’’ W.C.
(0.76 kPa)
AMPS: Less than 10 Amperes Maximum Working
Pressure: 150 PSI
RECOVERY RATING:
As used in this standard, the quantity of water obtained by multiplying the manufacturer’s input
rating in Btu per hour by thermal efficiency and dividing the product by 8.25 Btu per gallon. This is
based on a 100°F (37.8°C) temperature rise, and a nominal specific heat for water of 8.25 Btu per
gallon per degree F.
Not recommended in excess of 2,000 . Above sea level Category III Type B Water Heater
CANADIAN HIGH ALTITUDE RATING
Altude 0-2000 feet
Input (btu/hr) 170,000
Manifold pressure (in. W.C.) 3.45
CSA/ANSI 221.10.3 CSA 4.3-2021 SUITABLE FOR WATER (POTABLE) HEATING ONLY
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
This appliance must be installed in accordance with local codes
or, in the absence of local codes, the Naonal Fuel Gas Code,
ANSI Z223.1/NFPA 54 or the CSA B149.1, Natural Gas and
Propane Installaon Code.
The unit must be installed on a fire-retardant area and must be away from all combustible materials. Clearance should be 10in to the
left and right side of combustible materials, 16 in. above, 12 in. above the floor, and 6 in. to the front.
T
his water heater requires a special venting system. Refer to the installation instructions for parts list and methods of installation.
The temperature and pressure relief valve provided by the manufacturer shall be installed at the time of installation of the heater in
the location specified by the manufacturer. Local codes shall govern the installation of relief devices. For safe operation of the
water heater, the relief valve must not be removed or plugged.
INDOOR USE ONLY
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
CHAUFFE-EAU INSTANTANÉ AUTOMATIQUE
MODÈLE # : 6.5GB-ING Puissance Maximum
d’Entrée 170,000
SÉRIE # : Puissance Minimum
d’Entrée 17,000
TYPE DE GAZ : GAZ
NATUREL SEULEMENT Pression minimale
d’arrivée de gaz
3.5” W.C.
(.87 kPa)
Tension : 120 Volts Pression maximale
d’arrivée de gaz
10.5” W.C.
(2.61 kPa)
Fréquence : 60 Hz Pression d’admission 3.45’’ W.C.
(0.86 kPa)
Ampères : Moins de 10 Ampères Pression de travail
maximale 150 PSI
Note de Récupéraon:
Tel qu’ulisé dans la présente norme, la quanté d’eau obtenue en mulpliant la valeur nom
inale d’entrée du fabricant en Btu par heure par l’efficacité thermique et en divisant le produit
par 825 BTU par gallon. Ceci est basé sur un élévaon de température de 100 ° F, et une
spécificaon thermique nominale de l’eau de 8,25 BTU par gallon par degré F.
Non recommandé à plus de 2000 pieds au-dessus du niveau de la mer. Chauffe-eau De Catégorie III Type B
CANADIENNE ALTITUDE NOTE HAUT
Altude 0-2000 feet
Input (btu/hr) 170,000
Manifold pressure (in. W.C.) 3.45
CSA/ANSI 221.10.3 CSA 4.3-2021 ADAPTÉ À L’EAU (POTABLE) CHAUFFAGE SEUL
POUR VOTRE SÉCURITÉ
Ne pas entreposer ou uliser de l’essence ou d’autres
vapeurs et liquides inflammables à proximité de cet
appareil ou de tout autre appareil
Cet appareil doit être installé conformément aux codes locaux
ou , en l’absence de codes locaux , le Naonal Fuel Gas Code
, ANSI Z223.1 / NFPA 54 ou le CSA B149.1 , gaz naturel et
propane Code d’installaon
L'unité doit être installée sur une surface ignifuge et doit être éloignée de toutematière combustible. Le dégagement doit être de 10 po à
gauche et à droite des matériaux combustibles, de 16 po au-dessus, de 12 po au-dessus du plancher et de 6 po à l'avant.
Ce chauffe-eau nécessite un système de ventilation spécial. Reportez-vous aux instructions d'installation pour la liste des
pièces et les méthodes d'installation.
La soupape de décharge de température et de pression fournie par le fabricant doit être installée au moment de l'installa on de l'appareil
de chauffage à l'emplacement spécifié par le fabricant. Les codes locaux doivent régir l'installa on des disposi fs de décharge. Pour un
fonc onnement sécuritaire du chauffe-eau, la soupape de décharge ne doit pas être enlevée ou bouchée.
UTILISATION À L'INTÉRIEUR SEULEMENT