Content....................................................................................................................02
1.Product Introduce ..............................................................................................04
2.Fixture Size..........................................................................................................04
3.Parts Introduce................................................................................................ ...05
4.Safety Information..............................................................................................05
4.1 Anti-high temperature....................................................................................................06
4.2 To prevent falling wounding…………………………………………………………...06
4.3 UA protection…………………………………………………………………………..06
4.4 Prevention of electric shock…………………………………………………………….06
4.5 To prevent burning or fire………………………………………………………………06
5.Packing and Shipping ........................................................................................06
5.1 Attachment .....................................................................................................................06
5.2 About Device Package....................................................................................................07
5.3 Unpacking.......................................................................................................................07
6. Installation Standards .................................................................................................07
6.1 Rigging Installation ........................................................................................................07
6.2 Equipment Fixed.............................................................................................................07
6.3 Equipment Connection................................................................................................... 08
6.4 Cable Connection……………………………………………………………………….09
7.AC Power...........................................................................................................................09
7.1 Voltage, Fuse Specification………………………………………………………….....09
7.2 Power Connection.........................................................................................................10
8. Control Panel Operate………………………………………………………………...11

9. Technical Specification………………………………………………………..............12
10. DMX Control Channel Mode……………………………………………………….13
11.Led Position……………………………………………………………………16
12. Routine Maintenance…………………………………………………………17
STATEMENT
The product is good packing when ship out the factory. All users should strictly abide by the
warnings and instructions stated in this manual, any damage and results due to misuse and the
neglect of this operating manual will be excluded from the deal responsibility this manual will not
informed in additionally if have technical changes.
About the latest software, hardware, documents and other information, please log in our company
website.
1. Production Introduce
Thank you for choose this LM1915 products, this model is the newest led moving head light
which is the latest development of the smart, efficient products, beautiful shape, smooth R & D,

combined with the advanced technology of today's stage lighting products with international
advanced electronic control technology and excellent user-friendly industrial design.
This LM1915 Led light, use 19pcs high brightness 15w RGBW 4 IN 1 LED source, By
careful arrangement and design, make the R,G, B,W mixing evenly and colour is pure. Through
the built-in microprocessor control, Use the high precision of constant current control mode, the
R.G.B.W. can realize independent 0-255 of brightness adjustment, rich color changes. Through
the menu calls the built-in program, for scenario editor and setting sound, master-slave control
mode, can do rainbow, variable strobe and electric dimming effect.
LM1915 has quick response speed, seismic, impact resistance, good heat dissipation. Long
using life (the life of the LED is over 100000 hours) no radiation, high efficiency and energy
saving, low energy consumption, the real green products. Accept international DMX512 signal
mode.
LM1915 applications very widely, installation is simple and can be used for lighting in large
fixed stage, the background wash, large-scale theatrical performances, stadium lighting, temporary
stage shows, television stations, conference center, professional theaters, dance halls, bars, small
theatrical performances, and public environment illumination.
2. Fixture Size
Dimension:365(L)×256(W)×476(H)mm
3. Parts Introduce

4. SAFETY INFORMATION
Safety Warning: This product is only suitable for professional use, and does not apply to security
for other purposes. When you got the lights, please check the package whether have any damage
caused by transportation. If there is any damage, do not use this fixture, and please contact the
dealer or manufacturer as soon as possible. This product is only suitable for indoor, IP20
protection class. Lamps should be kept dry to avoid Moisture, overheating or dusty environment.
Prevent lamps come into contact with water or any other liquid. The use of this product should pay
attention to: fire, heat, electric shock, ultraviolet radiation, the lamp to explode or Shedding caused
serious or fatal injury. Please read the instructions before use energized or installing. Follow
through the operation of security methods and pay attention to the warning signs on the
specification and equipment.
4.1 ANTI-HIGH TEMPERATURE
ta=40°C
Please don’t use the equipment if the temperature above 40℃
Head
Cover
Lens
Component
PCB
Board
Arm
Shell
Handle
Touch
Screen
Horizontal
Cover
Die casting
aluminum radiator
Base
Shell
Display
Shell
Control
Wheel
Head
Back
Cover
Focus lens
component
Touch Screen
Battery Button

4.2 TO PREVENT FALLING WOUNDING
When Hang the fixture, please must verify that the facilities to be able to withstand at least 10
times or more weight of fixtures.
Please make sure the Mounting hardware is strong enough no any damage, and insurance for
the safety rope as auxiliary security fixed in other facilities will need to verify before installation.
Installing or removing the equipment, to make the pulley below the work location
4.3 UA PROTECTION
Forbid straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
Do not use the equipment without the lens screen and the lid;
The lens and the light head covers should be timely replaced if any damage to rupture.
4.4 PREVENTION OF ELECTIC SHOCK
The electrical connection must only be carried out with corresponding qualifications;
Before installing, make sure you use the power voltage lamps must comply with the
identified power, voltage and have an overload or leakage protection;
Each fixture must be properly grounded, installed in accordance with the relevant standards;
Cut off the power when stall or replace the lamp and the fuse;
Forbid using the fixture in storm or wet environment.
4.5 TO PREVENT BURNING OR FIRE
1. The fixture can't be mounted directly on the surface of ordinary combustible material.
2. The equipment must be installed away from inflammable and explosive materials.
3. The highest temperature is 40 ° C when the equipment is in stable state.
4. The equipment can not have an obstacle at least in the range of 0.5 meters.
5. Do not replace the non-original parts.
5. Packing and Shipping
5.1 ATTACHMENT
The LM1915 packed with fly-case of four in one, or carton box.
Attach follow accessory.
Content
Quantity
User Manual
1
DMX Cable
1
Safety Rope( charge)
1
5.2 About Device Package
1. Before packed, make sure power is off, and wait for at least 6mins for cooling down.

2.Clean the dust on the light.
3.After packed by plastic bag, high-lift the fixture with two handles besides the product. put
the product into the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the
fly-case.
5.Fly-case only up stacked two layers. Prohibited upside down.
5.3 UNPACKING
Note: Before unpacking check the damage is whether due to the transportation or not, if you find
any such damage, please do not use this item, and contact with the dealer or manufacturer as soon
as possible.
1. Open the fly-case, and discover the inside plastic bag.
2. High-lift the product by two handles beside the bottom base and move it out.
6. INSTALLSTRANDARD
Please ensure that make regular security checks for the lights and installation accessories.If lack
of these working conditions and professional level, please let the relevant professional person do,
unprofessional incorrect operation can lead to life-threatening.
The equipment suitable environment temperature range is 0OC - 40OC, don’t use it in too high or
too low temperature. When the equipment is on installation, dismounting, removing or
repairing,please don't stay in the right below of the fixture. The operator must ensure that the
fixture is a secure connection. Please let professionals to check its electrical parameters before
installation. Make sure the related experts check these installation once a year.
6.1 Rigging Installation
LM1915 can put on the stage or install on the bracket in any direction, the rapid locking
system can lock it on the bracket fast and easily according to the following picture 2 direction.
6.2 EQUIPMENT FIXED
1. Before installation must verify the fast lock is keep in good state, and can withstand at least
10 times the weight of product. Verify that the building can withstand at least 10 times of
the total weight of the product and accessory equipments.
2.Use the bolt and Nuts of M12 lock the hooks and fixture.
3. Fix the hang fixture into the hole, which located on the base of the light.
Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener in
the same method.

As the pictures show, the two square holes in the center of the base is the safety rope junction.
4. Using the safety cable which can withstand 10 times the weight of the equipment.
5. Make sure the X,Y protect locks are opened, Verify that within 0.5 meters there is no
combustibles .
6.3 EQUIPMENT CONNECT
Attention! One product only can accept one input and one output.
LM1915 has DMX input and output 3pin and 5pin connection socket.
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin
3connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data. 24AWG cable is
suitable for more than 300 meters long-distance signal transmission and must add\
DMX 512 signal amplifier.
Do not use two outputs to separate the connection, if separate a continuous connection
to branch, DMX512 splitter is necessary.

Attention! vertically up to put the fixture, the shortest safe distance between the
fixtures must be≥900 mm,the installation layout diagram as shown in the picture.
To prevent the reflection and interference of receiving the control signals, we must
install a terminal plug at the end of each branch of 3pin or 5pin output socket. Terminal plug
(welding a 0.25W,120Ωresistor between the 2 and 3 pin of 3pin or 5 pin socket.
6.4 CABLE CONNECTION
Attention! Signal wires connection is the X type connection.
X connection - if the fixture external cables damaged, the wires should use the manufacturer or
its service agent offered.
Connect the DMX data: from the controller to the nearest controller equipment 3pin or 5pin
socket, and then from this equipment output connected to the next equipment input, like this
continuous connecting, finally the output of the terminal equipment for the data cable insert a
terminal plug.
If use DMX512 distributor, the controller connect to the DMX512 distributor’s input firstly,
then connect the next equipment from the output of the distributor, according to this method,
Finally match the terminal plug.
7. AC power..
7.1 VOLTAGE, FUSE SPECIFICATION
Input Voltage
Fuse
200-240V
5A 5×20(Main fuse)
100-120V
10A 5×20(Main fuse)
7.2 Power Connection
The equipment must be operated by professionals; Make sure that the voltage of

power supply must be comply with the voltage identified on the lamp, and must have an
overload or leakage electrical protection.
ATTENTION!
The equipment directly connected to the power supply, Don't connect to the silicon box color
system, otherwise it will damage the equipment.Factory has equipped the standard 3 pin plug
socket. Connect the power supply as below table. Yellow and green wire could be connect to
ground. If the cable of the fixture is damaged, replacement should be operate by factory or qualified
staff.
Wire Colour
Plug
Mark
Brown
Live wire
L
Blue
Null
N
Yellow+Green
Ground wire
8. CONTROL PANEL MENU OPERATE
1: The indicating arrow in the right below is enter the menu (click the menu).
2: The touch screen display have four operation key: Exit, Upward, Downward, Enter, press it will
execute orders accordingly.
3: Can change the parameter Settings directly on the touch screen.
4: Also can use the wheel on the left side of touch screen to change the parameter Settings.
5: Can use the built-in battery by the left button of touch screen, change the parameter
Settings.When using the built-in battery for power supply, the green Indicator lights up.
6: The equipment have built-in temperature sensor, the temperature will display on the bottom left
corner of touch screen. When over the rated temperature, the equipment will start the automatic
protection function.
7: When the equipment receive the DMX512 signal,the blue light on the top right lights up, the
left side show have connected the XLR Socket..
CONTROLPANELMENU OPERATE
Address
DMX Address number set
001-512
Transfer Rate
029
Data
506
Signal quality
100%
Start Code
000
Fixed ID set
0-4096
Return
Special
White Balance
Off
Open
White Balance Red
(0-100%)0-255
White Balance Green
(0-100%)0-255

White Balance Blue
(0-100%)0-255
White Balance White
(0-100%)0-255
Dim Mode
Fast
Slow
ChunMode
Smal
Stan
Exte
RunMode
DMX
Auto
Musc
SigClear
Open
Off
Signal Reset
Open
Off
Rainbow
Exec
Annu
Return
InfoSee
Total Tim
00048:00
WorkHour
00000:03
Times
0000:61
ClearTim
-- -- --
ClearTim
-- -- -
Touch Screen_Control
Vtft.01(Software version)
XY _Control
(Software version)
LED _Control
(Software version)
Return
Control
Channel 01
(25%) 64
Channel 02
(50%) 127
Channel 03
(100%) 255
... ... ...
... ... ...
Channel118
(25%) 64
Channel119
(50%) 127
Channel120
(100%) 255
Display
ShowReve
Natu
Revl
Language
Chin
Engh
BrigSett
0%-100%
Backligh
Ligh
90s
MenuBack
Off
60s
Return

XY Setup
X Reverse
Off
Open
Y Reverse
Off
Open
XY Speed
Fast
NORM
Slow
X Angle
540°
360°
XY Fback
Open
Off
Pan
0-255
Tilt
0-255
Focus
0-255
Return
9. Technical specification
product specification:
1:Power consumption:400W
2: LED Quantity:19pcs 4 in 1 leds(RGBW)
3:Light Souce:Taiwan
4:2.8-inch touch screen display, Can be set up very intuitive personalization capabilities.
5:The super quality lens with focusing was imported from France Gaggione.
6:Single Lens Angle: 8 degree
7:Beam/ZoomAngle: 10-50 degrees, three linear motor adjust the lens angle.
8:Control Mode:Simple mode, Standard mode, Extended mode
9:Each led RGBW can be individual control,256 level of brightness control.
10:With sound and master-slave mode control function
11:Many strobe and rainbow effect.
12: With rich built-in single control settings program,every color and gobo can be adjusted.
Red(255)×Green(255)×Blue(255)×White(255)
Every background color of the built-in program can be adjusted Red(255)×Green(255)
×Blue(255)×White(255)
13:By using constant current control of each color, its brightness maintain on the same level no
matter in single fixture control or multiple fixtures control.
14:Pan scanning use 3phase motor:540º 8Bib(16Bitscanning precision),
15:Tilt scanning use 3phase motor:245º 8Bib(16Bitscanning precision),
16: Pan and Tilt adopt photoelectric reset system, can automatically inspect and reset,
17:DMX512 signal reception
18:Built-in temperature detection protection function.
19:Using APFC power factor correction function on the switching power supply, power
factor >0.98.
20: Working Voltage:AC:100V-240V,50-60Hz.

21:The maximum allowable temperature while working :40ºC.
22: IP Rate:IP20.
23:Size:337×256×352mm.
24:15.2Kg.
25: Pass CE standard and GB7000.217-2008, GB7000.1-2007 standard
26:Color:Black
10. DMX Control Channel Mode
Three control models
1: Simple mode 2:Standard mode 3:Extended mode
Simple
mode
Standard
mode
Extended mode
DMX Value
Description
Channel 1
Channel1
Channel1
0-255
Red(darkest ——brightest)
Channel2
Channel2
Channel2
0-255
Red Fine
Channel3
Channel3
Channel3
0-255
Green(darkest ——brightest)
Channel4
Channel4
Channel4
0-255
Green Fine
Channel5
Channel5
Channel5
0-255
Blue(darkest ——brightest)
Channel6
Channel6
Channel6
0-255
Blue Fine
Channel7
Channel7
Channel7
0-255
White(darkest ——brightest)
Channel8
Channel8
Channel8
0-255
White Fine
Channel9
Channel9
Channel9
0-255
Color temperature control
Channel10
Channel10
Channel10
Colour macro
1-4
Colour macro off
5-9
Colour1:White
10-14
Colour2:DirtyWhite
15-19
Colour3:AliceBlue
20-24
Colour4:DarkSteelBlue
25-29
Colour5:Deeplavender
30-34
Colour6:LilacTint
25-39
Colour7:DaylightBlue
40-44
Colour8:BastardAmber
45-49
Colour9:DeepOrange
50-54
Colour10:PaleGold
55-59
Colour11:Apricot
60-64
Colour12:BrightBlue
65-69
Colour13:Speciallavender
70-74
Colour14: PaleLavender
75-79
Colour15: BrightPink
80-84
Colour16: Mauve
85-89
Colour17: LeafGreen
90-94
Colour18: DarkBlue

95-99
Colour19: PeacockBlue
100-104
Colour20: Magenta
105-109
Colour21: DarkPink
110-114
Colour22: MiddleRose
115-119
Colour23: LightSalmon
120-124
Colour24: EnglishRose
125-129
Colour25: LightRose
130-134
Colour26: LightOrange
135-139
Colour27: Straw
140-144
Colour28: LightAmber
145-149
Colour29: DarkYellowGreen
150-159
Colour30: SkyBlue
160-169
Colour31: Lavender
170-174
Colour32: LightLavender
175-179
Colour33: PinkCarnation
180-184
Colour34: MediumPink
185-189
Colour35: LightPink
190-194
Colour36: SunriseRed
195-199
Colour37: DarkAmber
200-204
Colour38: MediumAmber
205-215
ColourForward Jump:Fast-Slow
216-228
ColourForward Jump stop
229-239
ColourForward Jump:Slow-Fast
240-245
Random Colour:Slow speed
246-250
RandomColour:Mid-Speed
251-255
RandomColour:Fast Speed
Channel11
Channel11
Channel11
Strobe
0-19
No strobe
20-49
Strobe ON
50-64
Conventional Strobe Fast-Slow
65-69
Strobe ON
70-84
Strobe turn on pulse Fast-Slow
85-89
Strobe ON
90-104
Strobe turn off pulse
Fast-Slow
105-109
Strobe ON
110-124
Random Strobe Fast-Slow
125-129
Strobe ON
130-144
Random turn on Fast-Slow
145-149
Strobe ON
150-164
Random turn off pulse
Fast-Slow
165-169
Strobe ON

170-184
Pulse Strobe
185-189
Strobe ON
190-204
Random pulse Strobe
Fast-Slow
205-209
Strobe ON
210-224
Orthodox Gradients Fast-Slow
225-229
Strobe ON
230-244
Pulse Fast-Slow
245-255
Strobe ON
Channel12
Channel12
Channel12
0-255
Master dim
Channel13
Channel13
Channel13
0-255
Master dim Fine
Channel14
Channel14
Channel14
0-255
Pan motor control
Channel15
Channel15
Channel15
0-255
Pan Fine
Channel16
Channel16
Channel16
0-255
Tilt motor control
Channel17
Channel17
Channel17
0-255
Tilt Fine
Channel18
Channel18
Channel18
0-255
Function Setting
Channel19
Channel19
Channel19
0-255
Reset control
Channel20
Channel20
Channel20
0-255
Focus
Channel21
Channel21
Channel21
0-255
LED graphic display
Channel22
Channel22
0-255
Auto- program selection
Channel23
Channel23
0-255
Auto- program speed setting
Channel24
Channel24
0-255
Auto- program fade-in
Channel25
Channel25
0-255
Auto- program Red
Channel26
Channel26
0-255
Auto- program Green
Channel27
Channel27
0-255
Auto- program Blue
Channel28
Channel28
0-255
Auto- program White
Channel29
Channel29
0-255
Auto- program Focus
Channel30
Channel30
0-255
Backlight dimming
Channel31
Channel31
0-255
Reserve
Channel32
Channel32
0-255
Reserve
Channel33
Channel33
0-255
Reserve
Channel34
Channel34
0-255
Reserve
Channel35
Channel35
0-255
Reserve
Channel36
0-255
Led1 single control_Red
Channel37
0-255
Led1 single control_Green
Channel38
0-255
Led1 single control_Blue
Channel39
0-255
Led1 single control_White
... ... ...
... ... ...
... ... ...
Channel108
0-255
Led19 single control_Red
Channel109
0-255
Led19 single control_Green
Channel110
0-255
Led19 single control_Blue
Channel111
0-255
Led1 9 single control_White

Remark:Reset Channel Value, reset it after it stay the effect value 5 seconds.
11.Led Position
12. Routine Maintenance
Cleaning and maintenance
LM1915 need do daily cleaning and maintenance, the equipment life time is greatly depends
on the operating environment, please consult the technical department for professional advice,
submit the repair and maintenance to the professional technician.
Attention! Too much dust, smoke flow, the damage by unnormal use, are not covered under

warranty.
Warning! Pls turn off the power supply before you open any cover.
Fixture Cleaning
Optical components need to be clean gently, coating surface is very fragile, it is easy to scratch,
keep the acrylic plate clean, or will affect the brightness of the fixture, don't use destructive
solvent, otherwise it will damage the plastic or coating.
Clean the optical element
1: after turning off the power, open the cover.
2: Using a vacuum cleaner or pressure blow down gently blowing off the dust.
3: With No bouquet cotton paper or using cotton cloth with water or distilled water to wipe the
granular material, do not wipe the surface, use the pressure gas blow away the dust.
4: with dip with ethylene propylene glycol cotton cloth or No smell of cotton paper to remove the
dust and residues, also can use glass cleaner, but must use distilled water to remove residues, wipe
from the center to both sides, then wipe it dry with a soft cotton cloth.
Clean the fan and the air hole
With a soft brush, cotton paper, the air cleaner or pressure fan get rid of the dust from the fans and