Eden SOLO User manual

Access control
SOLO / SOLO 3000
Biometric reader with RS485 output
Technical manual

Technical manual SOLO/SOLO3000 –V1.5 p.2/12
Contents
Contents ......................................................................................................................... 2
Acknowledgement ......................................................................................................... 3
Information and recommendations.............................................................................. 4
Technical characteristics.............................................................................................. 5
1) SOLO/SOLO3000.................................................................................................. 5
2) Compatibility.......................................................................................................... 5
Wiring diagram............................................................................................................... 6
1) Connecting reader on C1P2FX control unit ........................................................... 6
2) Connecting reader on C4PLUSFX control unit ...................................................... 7
3) Connecting reader on GENIUS control unit........................................................... 8
Connectors blocks......................................................................................................... 9
Check list....................................................................................................................... 10
Notes.............................................................................................................................. 11

Technical manual SOLO/SOLO3000 –V1.5 p.3/12
Acknowledgement
Dear client,
You have just purchased a “SOLO/SOLO3000” fingerprint identification reader built by the
company EDEN INNOVATIONS.
The entire EDEN INNOVATIONS team would like to thank you for your interest as well as
your confidence in our security solution.
We hope that you will be completely satisfied with the level of security it provides for your
company’s premises.
Should you have any comments, please contact us via our web site at
www.eden-innovations.com
The EDEN INNOVATIONS team.

Technical manual SOLO/SOLO3000 –V1.5 p.4/12
Information and recommendations
o Pursuant to European directive UTE C00-200, incorporating directives 89/336 EEC and 92/31
EEC, SOLO/SOLO3000 complies with the following standards:
• NF EN 50081-1 governing electromagnetic radiation, and
• NF EN 50082-1 governing electromagnetic susceptibility.
o Cabling recommendations: the cables used to connect readers, the network and other
peripherals must be installed in accordance with the instructions for Level 2 (protected
environment) of standard NF EN 61000-4-4.
o This product must be installed by an approved company. Incorrect installation and usage
may result in electric shock or fire. Before installing the product, read the technical information
and comply with the recommendations.
o Once the power is turned off, all the internal capacitors will discharge themselves to a
safe level after 60 seconds under normal conditions. However, in the event of a power
failure, the charge may be maintained for much longer and suitable.

Technical manual SOLO/SOLO3000 –V1.5 p.5/12
Technical characteristics
1) SOLO/SOLO3000
Maximum power consumption ........300mA @12V
Power supply voltage......................9 –14VDC
Weight.............................................195 g
Housing dimensions........................121 x 78 x 39 mm
Operating temperature....................- 20°C to + 50°C
........................................................-4°F to +122°F
Fingerprints SOLO..........................500 templates
Fingerprints SOLO3000..................3000 templates
2) Compatibility
Software:
SENATORFX.NET..........................V1.1.6.0 or later
SENATORFX....................................V5.0.11 or later
Hardware:
C1P2FX ..........................................V2.4 or later
C4PLUSFX .....................................V4.0 or later
GENIUS..........................................V1.0 or later

Technical manual SOLO/SOLO3000 –V1.5 p.6/12
Wiring diagram
1) Connecting reader on C1P2FX control unit
Data sheet :
Be sure to use the same pair for A and B
Be sure to separate the supply from the bus RS485
Characteristic: Sensitive connection
Screen: Mandatory
To achieve 1200m (2730 ft), you need to install a 120resistor at each end of the network
between points A and B (see above).
Caution: The total length must not exceed the recommended distance.
A
B
A
B
SYT recommended
1200m (2730 ft) Max
Ø 0.6 mm (1/30 in)
2 pairs recommended
RS485
-
+
POWER SUPPLY
12Vcc

Technical manual SOLO/SOLO3000 –V1.5 p.7/12
POWER
SUPPLY
12Vcc
2) Connecting reader on C4PLUSFX control unit
(?) Data sheet :
Be sure to use the same pair for A and B
Be sure to separate the supply from the bus RS485
Characteristic: Sensitive connection
Screen: Mandatory
To achieve 1200m (2730 ft), you need to install a 120resistor at each end of the network
between points A and B (see above).
Note: The total length must not exceed the recommended distance.
A
B
A
B
SYT recommended
1200m (2730 ft) Max
Ø 0.6 mm (1/30 in)
2 pairs recommended
-
+
RS485

Technical manual SOLO/SOLO3000 –V1.5 p.8/12
3) Connecting reader on GENIUS control unit
(?) Data sheet:
Be sure to use the same pair for A and B
Be sure to separate the supply from the bus RS485
Characteristic: Sensitive connection
Screen: Mandatory
To achieve 1200m (2730 ft), you need to install a 120resistor at each end of the network
between points A and B (see above).
Note: The total length must not exceed the recommended distance.
A
B
A
B
SYT recommended
1200m (2730 ft) Max
Ø 0.6 mm (1/30 in)
2 pairs recommended
Power Supply
+12Vcc
+
-
RS485

Technical manual SOLO/SOLO3000 –V1.5 p.9/12
Connectors blocks

Technical manual SOLO/SOLO3000 –V1.5 p.10/12
Check list
SOLO / SOLO 3000
Serial number :
ID number :
Gasket :
Torx bit :
Torx screw :
Bag :
Wall seal :

Technical manual SOLO/SOLO3000 –V1.5 p.11/12
Technical Support :
Notes
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------------------------------

Zone Commerciale et Artisanale
670, route de Berre
13510 EGUILLES
France
www.eden-innovations.com
This manual suits for next models
1
Table of contents
Other Eden IP Access Controllers manuals
Popular IP Access Controllers manuals by other brands

Alarm Lock
Alarm Lock Trilogy DK3000 Series installation instructions

David-Link
David-Link DL-AP KIT installation guide

Nice
Nice C2 PRO Instructions and warnings for installation and use

Altronix
Altronix TROVE Mercury Series T3MK75F16 installation guide

Digiplex
Digiplex Paradox ACM12 Installation instructions and instructions for use

Soyal
Soyal AR-721H manual