In this part, the detector mounting is explaned. Please do not start the
mounting operation before understanding the system, parts and the working
principle of the system. You are recommended to start mounting after reading
the warning and the points to take into consideration.
WARNING
Anti-static measures should be taken before touching electronic materials.
Mounting and maintenance should be done by authorized personnel. The
failures to cause damage after interventions to be made the device before
reading the user manual completely, can exclude the device outside the scope
of warranty.
Wall Mounting
First of all, open the cover of the detector.
Make the cabling of the places where 20mm cable sleeves to come.
Find the 4 pieces mounting places shown with number 1.
Choose a clean and smooth wall at eye level.
Select a clean and smooth wall for eye level. Pay attention to mount a place
without air current, fan and vibration. It is not recommended to be mounted
closer to devices with radio frequency. Pay attention to be mounted to a
suitable place for calibration and maintenance. Mount from the required
places by using M4x30 mm screw and Ø 6mm socked for the panel mounting.
8
MOUNTING AND CABLING
CO
Gas
Detector