4 NON-SCRATCH PADS ON THE BACK OF METER
HARD COAT OR SOFT COAT LOW E APPLICATIONS
ULTRA-SENSITIVE CIRCUITRY
SIMPLE BATTERY TEST
NO ADJUSTMENTS OR CALIBRATIONS NECESSARY
SMALL, PORTABLE CONVENIENT SIZE
GENERAL DESCRIPTION:
FEATURES:
MODEL #CM1030
LOW E CONTACT METER
RELATED PRODUCTS FROM EDTM, INC.
EASY-TO-READ
INDICATOR
01/2001 cm1030\opman01.cdr
CM1030 WARRANTY
The manufacturer warrants all models of the CM1030 to be free from defects in material
and workmanship under normal use and service as specified within the operator's
manual. Themanufacturershallrepairorreplacetheunitwithinninety(90)daysfromthe
original date of shipment after the unit is returned to the manufacturers factory, prepaid
by the user, and the unit is disclosed to the manufacturers satisfaction, to be thus
defective. This warranty shall not apply to any unit that has been repaired or altered
other than by the manufacturer. The aforementioned provisions do not extend the
original warranty period of the unit which has been repaired or replaced by the
manufacturer. Batteriesarenotcoveredbywarranty.
EDTM, Inc. assumes no liability for the consequential damages of any kind through the
use or misuse of the CM1030 product by the purchaser or others. No other obligations or
liabilities are expressed or implied. All damage or liability claims will be limited to an
amountequaltothesalepriceoftheCM1030.
CONVENIENT BATTERY
REPLACEMENT
SIMPLE BATTERY-TEST
PUSH-BUTTON
BATTERY REPLACEMENT
The CM1030 is powered by a 9 volt battery. To test the battery voltage, simply push the
Battery Test button on the front of the meter. If the indicator lights, the battery voltage is
sufficient to operate the meter. If the indicator appears dim, you may choose to
replace the battery. To replace the battery, remove the battery cover near the
bottom of the meter and replace with a new battery. Alkaline batteries will provide the
longest service, but are not required for this product.
The CM1030 is a simple instrument that detects any conductive
surface, including Low E coatings on single sheets of glass. The low-
cost tester has 4 non-scratch pads on the back-side of the meter that
allow you to test for conductive coatings (VIA CONTINUITY). Simply
pressthemeteragainstapieceofglasstodetermineifthesurfaceyou
aretouchingcontainsanyconductive(LowE)coatings.
NEAR FAR CLEAR
YELLOW
RED
GREEN
ALL LIGHTED
THE LOW-E COATING
IS ON THE
NEAR PANE
THE LOW-E COATING
IS ON THE
FAR PANE
THE WINDOW IS
CLEAR OF ANY
LOW-E COATING
THE ETEKT+ IS
CONTACTING THE
LOW-E COATED
SURFACE
CONTACTING
LOW E
(Surface 2) (Surface 3) (No Low E) (Surface 1)
"ETEKT+" DUAL PANE LOW E COATING DETECTOR (MODEL# AE1600)
KEEP THE COMPETITIVE EDGE WITH PRODUCTS FROM
745 Capital Commons Drive
Toledo, Ohio 43615 USA
PHONE: (419) 861-1030 FAX: (419) 861-1031
WWW.EDTM.COM Email: [email protected]
01/2001 cm1030/opman02.cdr
APPLICATIONS
The CM1030 is a simple instrument that detects any conductive
surface,includingLowEcoatingsonsinglesheetsofglass.
The meter has a unique design that allows you to easily test hard coat
(pyrolytic) or soft coat (sputter) Low E coatings. Because of the ultra-
sensitivedesign,themeterisevencapableofdetectingmostcoatings
thatareprotectedbyathinprotectivedielectriccoating.
The CM1030 is the ideal product for the manufacturing environment.
For production environments where hand-held products tend to
disappear and get abused, the low cost CM1030 is a great addition.
Due to the simplicity of the meter, production personnel do not require
extensivetrainingtounderstandthemetersindication.
TheCM1030isgreatforidentifyingtheorientationoftheLowEglassasit
is being placed into the washers or assembled into insulating glass
assemblies. It also can be valuable in edge deletion applications,
where the operator must confirm the Low E side of the glass. All Low E
handlers in the production environment should be equipped with this
lowcostassistant.
Because of its professional appearance and low price, the CM1030
provides a GREAT sales aid to be distributed to your customers. Help
your customers reduce their mistakes in handling Low E glass. Private
labelingisavailableforthisproduct. ContactEDTMforinformation.
TESTINGSEALEDINSULATINGUNITS
The CM1030 must physically come into contact with the conductive
(Low E) coating in order to detect it (continuity measurement).
Therefore the CM1030 can NOT be used to test IG units that have
alreadybeenassembled. Forapplicationswhereyouareworkingwith
sealedinsulatingglass(IG)units,upgradetothe"ETEKT+"Low ECoating
Detector (EDTM Model# AE1600). For sealed insulating units, the
AE1600 can take measurements without physically touching the
conductivecoating. ThisoffersatremendousadvantageifasealedIG
unitmustbetestedfortheinvisibleLowEcoating,eitherinthefactoryor
inthefield.
OPERATINGTHEMETER
The back-side of the meter contains four (4) non-scratch nickel-plated
pads. These pads are used to contact the coating or glass substrate
thatisbeingtested. Tooperatethemeter,simplypressthebackside of
the meter firmly against the glass. The four pads should directly
contact the glass substrate being tested. If you are touching the
conductiveLowEcoating,the indicatorwilllighttosignalthecoatingis
onthetopsurface.
If the meter does not detect a conductive coating (LOW E), then flip
thepiece ofglass overandtakeanotherreading. Iftheindicatordoes
not light on either side of the glass, the glass is clear glass without any
conductivecoatings(NOLOWE)
DoNOTslidethemeter aroundthe glass,asthis couldpotentially leave
streaks on the glass substrate. Simply apply a firm pressure on the
meter, and it will identify the presence of conductive coatings. If the
glass is covered with a powder separator, it may be necessary to take
several readings to confirm the pads are contacting the glass directly,
and not being insulated from the glass by the powder separator. It is
recommended that you clear the powder from a section of the glass
beforetakingareading.
DoNOTpushthe"Battery Test" push-buttonwhile takinga reading. The
Battery Test button will automatically turn on the indicator. This button
should only be pushed when the user wants to test the strength of the
battery.
The meter is powered by a 9 volt battery inside the battery
compartment. DoNOTapplyanyexternalvoltagesourcestothepads
ofthemeter,asthiswilldamagetheelectronics.
Reduce costly mistakes in manufacturing
Hard coat or soft coat Low E applications
Non-scratch pads protect Low E
Private labeling available
Identify Low E in production easily
GREAT quantity discounts!!
Ultra-sensitive design detects ALL conductive coatings
Offer as a promotional tool to satisfy customer concerns
Equip ALL production personnel with this LOW-COST tester

Other EDTM Measuring Instrument manuals

EDTM Glass-Chek ELITE GC3200 User manual

EDTM

EDTM Glass-Chek ELITE GC3200 User manual

EDTM WP4500 User manual

EDTM

EDTM WP4500 User manual

EDTM SP2065 User manual

EDTM

EDTM SP2065 User manual

EDTM Glass-Chek PRO User manual

EDTM

EDTM Glass-Chek PRO User manual

EDTM GLASS-CHEK+ GC2001 User manual

EDTM

EDTM GLASS-CHEK+ GC2001 User manual

EDTM TINT-CHEK PRO TC3800 User manual

EDTM

EDTM TINT-CHEK PRO TC3800 User manual

EDTM MG1500 User manual

EDTM

EDTM MG1500 User manual

EDTM GC3000 User manual

EDTM

EDTM GC3000 User manual

Popular Measuring Instrument manuals by other brands

Picotest P2104A Documentation

Picotest

Picotest P2104A Documentation

Tymate M7-3 user manual

Tymate

Tymate M7-3 user manual

wtw Multi 3430 operating manual

wtw

wtw Multi 3430 operating manual

ARAG DigiWOLF 4627 Series Installation, use and maintenance

ARAG

ARAG DigiWOLF 4627 Series Installation, use and maintenance

GQ Electronics EMF-360V2 user guide

GQ Electronics

GQ Electronics EMF-360V2 user guide

Extech Instruments CO230 user guide

Extech Instruments

Extech Instruments CO230 user guide

Keysight PD1500A System installation guide

Keysight

Keysight PD1500A System installation guide

ABB FEX300 Original instruction

ABB

ABB FEX300 Original instruction

MASHIN VAT-650 user guide

MASHIN

MASHIN VAT-650 user guide

ATI Technologies Q45D manual

ATI Technologies

ATI Technologies Q45D manual

Zenner WPD installation manual

Zenner

Zenner WPD installation manual

kowatec IRF150 user manual

kowatec

kowatec IRF150 user manual

PASCO WA-7428 Product guide

PASCO

PASCO WA-7428 Product guide

ESD SYSTEMS SPl-20686 Operation installation and maintenance

ESD SYSTEMS

ESD SYSTEMS SPl-20686 Operation installation and maintenance

TPS WP-80M manual

TPS

TPS WP-80M manual

Setra Systems Power Patrol Operator's guide

Setra Systems

Setra Systems Power Patrol Operator's guide

Hanna Instruments HI 991301 instruction manual

Hanna Instruments

Hanna Instruments HI 991301 instruction manual

Tecnologic TRH 12 manual

Tecnologic

Tecnologic TRH 12 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.