eeese Emma 2568 User manual

User manual
Dehumidier
Emma
Art. 2568
Thank you for choosing this product.
Please read this instruction manual before using it.

2 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 3
DANSK.............................................................. 4
SVENSKA ........................................................ 29
SUOMI............................................................... 54
NORSK.............................................................. 79
ENGLISH.......................................................... 104
DEUTSCH........................................................ 129
NEDERLANDS............................................... 154
POLSKI.............................................................. 179

104 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Table of Contents
1. Safety Instructions............................................................................................................................ 105
2. Parts List ................................................................................................................................................. 107
3. Continuous Drainage ........................................................................................................................ 109
4. Prior to Operation................................................................................................................................ 109
5. Operation Instructions ..................................................................................................................... 110
6. Cleaning the dehumidier .............................................................................................................. 117
7. Storage..................................................................................................................................................... 118
8. Display error codes............................................................................................................................ 118
9. Trouble Shooting................................................................................................................................. 119
10. Technical Specications ................................................................................................................. 121
11. Service...................................................................................................................................................... 121
12. Warranty .................................................................................................................................................. 122
13. Responsible Disposal........................................................................................................................ 123
14. Warning on Refrigerant R290...................................................................................................... 123
15. Connection to WIFI............................................................................................................................. 124
Please read the user manual before any use, refer to the
corresponding section in this user manual. Save it for future
reference. We reserve the right for any error in text or images
and any necessary changes made to technical data.
Recycle unwanted materials instead of disposing of them.
All appliances and packaging should be sorted and tendered
at a regional recycling centre and be processed in an
ecological manner.
The product conforms to the applicable European and
other directives.

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 105
UK
1. Safety Instructions
Warning
This appliance is intended for use in a domestic environment only. Any other use
is not recommended by the manufacturer and may cause re, electrical shocks
or other person injury and property damage. Never try to dismantle or repair the
machine yourself. The appliance shall be installed in accordance with national wir-
ing regulations. The machine is designed A-weighted sound pressure level below
70dB. Check the voltage and make sure it meets the technical specication of the
machine. This machine can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved.
Cautions Wet hands not allowed Warning
Power Cord
Do not pull the
power cord in
order to unplug
the device from
the socket.
Do not use
the appliance
in overloaded
extension cord.
Do not put any
heavy objects
on the power
cord in order
to avoid safety
hazard.
Do not use the
appliance if its
socket holes
cannot rmly
hold a plug.
Do not attempt
to change the
power cord,
contact the
authorized
service centre
for repair.
Do not touch
the plug with
wet hands in
order to avoid
electric shock.

106 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Unplug the
product im-
mediately if it
emits strange
noises, odours
or smoke. Please
pull out the plug
during lightning
storms. Unplug
the product
when it is not
in use.
The socket has
to be earthed
and appropriate-
ly secured.
Placement
Do not put am-
mable and ex-
plosive objects
around the appli-
ance in order to
avoid re.
Do not use
the appliance
in swimming
pool or similar
facilities in order
to avoid safety
hazard.
Do not use the
appliance in a
draughty place
or next to a radi-
ator or heating
appliance.
Place the appli-
ance on a stable,
at surface. The
machine must
always stand
upright.
During Use
Before moving
the dehumidier
please turn o
the power,
unplug the
power cord and
make sure that
the water tank
is empty
Do not pour
water into the
appliance in
order to avoid
malfunction.
Children shall
not play with
the machine.
Never insert for-
eign objects into
the machine.
Do not put any
heavy objects
on the appliance
in order to avoid
malfunction.
Never sit on the
product.

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 107
UK
Do not push
the appliance
over or let the
appliance suer
strong impact
in order to avoid
malfunction.
The appliance
must not be
covered when
being used.
Do not put
hands on the air
outlet in order
to avoid injury or
malfunction.
2. Parts List
Components
1. Air Outlet
2. Pre Filter
3. Drainage Outlet
4. Water Tank
5. Castors
6. Handle
7. Rear Cover
8. Power Cord
9. Control Panel
10. Front Cover
1
2
3
4
5
8
6
7
9
10
1
2
3
4
5
8
6
7
9
10

108 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Control panel
11. Power Button
12. Timer O Button/ Wi-Fi Button
13. Manual Dehumidifying Button
14. Timer Indicator
15. Tank Full Indicator
16. Defrost Indicator
17. Ionizer Indicator
18. Low Fan Speed Indicator
19. High Fan Speed Indicator
20. Fan Speed Button / Child Lock Button
21. Ionizer Button
22. Mode Button
23. Manual Dehumidifying Indicator
24. Auto Dehumidifying Indicator
25. Laundry Drying Indicator
26. Humidity Reading
27. Sleep Indicator
28. Air Purifying Indicator
29. Wi-Fi Indicator
22 2 1 20 13 12 11
23 24 2825 26 27
19 1 8 1 7 16 15 14
29
Drainage
30. Drainage Outlet
31. Drainage Pipe
Drain hose
not included
30 31

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 109
UK
3. Continuous drainage
Continuous drainage option allows easy removal of collected water instead of manually
emptying from the water tank when the environment is very high humidity.
1. Remove the rubber plug covering the drain hose connection.
2. Connect a suitable drain hose (14mm inner diameter) to the drainage outlet.
Ensure that the hose is secure and tight to prevent leakage.
3. Always make sure the drainage hose is not blocked or obstructed to maintain
a smooth ow.
Please always make sure the pipe is going downwards, and is not blocked or kinked.
Drain hose is not included, but as a extra purchase. Art. no. 2558
4. Prior to operation
• Check the dehumidier for any transport damages. In case of damage, you should
contact our service line immediately.
• Place the dehumidier in an upright position on a stable, at surface.
• Make sure that the mains lead is easily accessible and is not damaged by sharp
edges or is crushed in any way during use.
• Ensure the dehumidier is at a safe distance at least 50 cm away from a wall
or furniture and has air space on all sides.
• The machine must stand upright for at least 1 hour before it is used for the rst time
• If any part of your house suers from severe humidity, the dehumidier can be
placed there rst and then moved to another part of the house later.
• Ensure the power supply is in correspondence with the value on the nameplate
and power outlet needs to be grounded.
• Ensure the water tank is correctly tted before the dehumidier can be switched on.
• If the dehumidier is turned o and then turned back on again immediately, it will
take approximately 3 minutes to reach full power (compressor back to work).
• If the dehumidier is switched o by a power cut, it will automatically switch back
on once the power is restored.
• The dehumidier works best at normal room temperature, its eiciency is reduced
if the ambient temperature falls to below 15°C.
• Turn on the power and run the machine as per instructions below.

110 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
≥20cm
≥50cm
≥20cm
≥20cm
≥20cm
5. Operation instructions
Connect the power plug to the correct power supply; the machine will enter into
standby with “beeping” sound.
Desired setting will be conrmed 3 seconds after the operation.
Switch On / Switch O The Unit (Power button)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
1. Connect the mains lead to socket.
2. Press Power button (A) once to turn on the unit. By default, it runs on
Manual Dehumidifying Mode with high fan speed.
3. Press Power button (A) once again to turn o the unit. It will stop working, but the
fan will work for some seconds to blow out the hot air inside the unit.

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 111
UK
Auto shut-o timer function (Timer button)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Timer Button (A) to select your preferred timer hour from 00-24-00.
To cancel the timer function, switch o the unit and switch in on again. Or press
the timer button and hold it down for 3 seconds. Repeat it one more time.
Humidity setting (Manual button)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Humidity Setting Button (A) to select the desired maximum level of humidity
between the following CO-30%-35%-40%-45%-50%-55%-60%-65%-70%-75%-80%-CO.
CO stands for continuous non-stop dehumidication regardless of ambient humidity.
At manual mode, all buttons are enabled

112 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Fan speed option [Fan Speed button]
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Fan Speed Button (A) to select your preferred fan speed setting of low and
high to meet the dierent usage requirements.
Fan Speed Button is invalid at laundry drying mode, auto mode and defrost mode.
Ionizer function [Manual button]
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
The ionizer creates negative ions that attach to positive charged molecules such as dust,
bacteria, pollen, smoke, and other allergens. These molecules attach to each other into
bigger molecules that cannot oat in the air and falls to the ground.
Press the Ionizer Button (A) to activate the ionizer function.
The ionizer mode will be o automatically when the fan stops working.

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 113
UK
Auto dehumidifying function [Mode button]
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Mode Button (A) to select the Auto Dehumidifying Mode.
The unit runs automatically accordance to the ambient humidity detected below.
The Fan Speed Button is disabled in this mode.
Ambient RH% detected Compressor Fan Speed Level
RH%>65% Working High
55%≤RH%≤65% Working Low
RH%<55% Stops Working Low
RH = Relative humidity
Multifunction optional [Mode button]
Laundry Drying Mode
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Mode Button (A) 2 times to select Laundry Drying Mode (B).
The unit runs in continuous dehumidication with high fan speed for 6 hours,
then turns o automatically. The Fan Speed Button is disabled in this mode.

114 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Sleep Mode
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Mode Button (A) 3 times to select Sleep Mode (B).
The unit runs with a designated humidity setting of 55% along with low fan speed.
All indicators will be o 5 seconds after the setting is completed. Touch any button
to activate the light, and to operate as usual. The Fan Speed Button is enabled.
After 30 seconds the lights will be o, If no further operation. If the water tank
is full on sleep mode, the full water tank indicator will always be on.
Air Purifying Mode
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Mode Button (A) 4 times to select Air Purifying Mode (B).
The unit runs with high fan speed without dehumidifying.
The Fan Speed Button is enabled.
With the additional purchase of a HEPA lter, the dehumidier can be upgraded to
a 2-in-1 hybrid model - a combined dehumidier and air purier.
With a HEPA lter (extra purchase), you add the possibility of improving the air
quality in the room. A HEPA lter helps against the accumulation of dust, pollen and
other allergens, and reduces allergic reactions. In addition, the lter removes mold
spores, bacteria and viruses from the air. A HEPA lter can not be washed.

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 115
UK
Safety childlock function
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
To prevent the mishandling by young children, the unit is equipped with a childlock
function. Press the Fan Speed Button (A) for 2 seconds to lock all buttons with
a beeping sound. The same operation can unlock it.
Safety childlock function can be set at standby mode and working mode,
but can’t be activated when the water tank is full.
Wi-Fi Function (Timer button)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
Press the Timer Button (A) for 2 seconds to activate the Wi-Fi function and enter into
the network mode. During the network conguration, the Wi-Fi indicator (B)
ashes quickly and after the Wi-Fi is connected, the icon is on and stops ashing.
See below section Connection to Wi-Fi for detalied settings. When the machine
is in network mode, press the timer button for some seconds to disconnect
the WiFi connection.

116 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Auto shut o with full water tank indicator
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
When the water tank becomes full during normal use, the unit will go into standby mode
automatically and the Full Tank Indicator (A) will show. After emptying the tank, the unit
will go on to the previous mode.
Except for the power button, all other buttons are disabled in this state.
If the water tank is removed or not placed properly, the above described will occur.
Low temperature defrost mode
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(B)
(B)
(B)
(B)
When the ambient temperature is too low, the dehumidier will enter into
the Defrost Mode. The unit runs with high fan speed without dehumidifying.
Fan speed button is disabled in this state.

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 117
UK
Memory function
1. If the unit is unplugged directly or due to power failure, reconnect the unit to the
power supply and the dehumidier will run with the mode prior to the shutdown.
The timer setting will be kept.
2. Press the power button to switch o the dehumidier, and then press the power
button to switch it back on. The dehumidier will run with the mode prior to the
shutdown. The timer setting will be canceled.
2. Switch o the dehumidier and unplug the power cord. Then reconnect the power
supply and switch on the dehumidier. It will run as factory preset mode the rst time
you received the dehumidier.
6. Cleaning the dehumidier
When used regularly, the lter may become clogged with dust and particles. To ensure
the eectiveness of the dehumidier, it is recommended to clean the unit at least every
two weeks:
Switch the device o and remove the plug from the socket
before cleaning.
Clean the housing with a soft, dry cloth. Vacuum clean
the air inlet and outlet grilles of the dehumidier. If the
device is extremely dirty, use a mild cleaning agent.
Wipe the dehumidier with a slightly damp cloth. Remove
the water tank and wash it by hand using a mild detergent.
Rinse it with clean water
Note: Do not spray water directly onto the unit.
Cleaning and user maintenance shall not be made by children
without supervision.

118 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Cleaning the Pre Filter
1. Remove the pre lter frame from the back.
2. Wash the pre lter frame carefully in warm water,
use a mild detergent if necessary. (Max. 40°C)
Note: DO NOT wash the pre lter in a dishwasher.
3. Rinse the pre lter in clean water and let it dry
before reinserting it.
4. Fit the pre lter frame back onto the unit.
Note: DO NOT use the dehumidier without
the pre lter in place.
7. Storage
If the dehumidier will not be used for a long period of time, take the following steps:
1. Remove the plug from the socket and empty the tank, make sure the tank and the
dehumidier is completely dry. This may take a couple of days.
2. Clean the pre lter.
3. Check the dehumidier for perfect condition to ensure a safe use of it after a long
period of storage.
4. Pack the device with the suitable packaging.
5. Store the dehumidier in a dust-free location, and out of direct sunlight.
Preferably covered with a sheet of plastic.
8. Display error codes
Please contact our eeese service line if any of the error codes below appears.
DISPLAY
CODE E1 E2 L3 L4
Error The temperature
sensor error
The humidity
sensor error
The air inlet
temperature is
too high >42°C
The air inlet
temperature is
too low <0°C
Display Flash every
30 seconds
Flash every
30 seconds Slow ash L3 Slow ash L4
What is
happening
The device works
normally.
The device
works normally,
but can’t set
the humidity
The compressor
stops working, fan
works at low fan
speed. 10 mins later,
if the temperature
decreases to below
40°C, the device will
work normally.
The compressor
stops working,
fan works at
low fan speed.
10 mins later, if
the temperature
increases to
above 2°C, the
device will work
normally.

MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps 119
UK
9. Trouble Shooting
Check the following before contacting technical support .
PROBLEM POSSIBLE CAUSE SOLUTION
The dehumidier
will not switch on
The power is not connected
Insert the plug into the wall
outlet and make sure the
power is on
The water tank is full Empty the tank
The tank has not been replaced
correctly Replace the tank
The set humidity level has been
reached Lower the humidity level
Power plug or cord damaged Contact an authorized
service centre for repair
Water removal
capacity is too low
Runtime is too short Be patient and wait
The ambient temperature
or humidity is too low
It is normal that the device
does not dehumidify in
these conditions
The device works,
but reduces the
relative humidity
insuiciently
The room is too big
We recommend using a
dehumidier with a greater
capacity
There is too much ventilation
Reduce the ventilation
(e.g. close windows and
shut doors)
The air lter is clogged Clean the Pre-lter
The humidity is higher than
the ambient humidity
Set the humidity lower
than ambient humidity
The humidity is
not reducing
The dehumidier has not been used long enough
The ambient temperature is too low
The surrounding humidity level is too low
The ambient humidity level is lower than the desired humidity
level set
The air lter frame is dirty Clean the pre-lter frame
Dehumidier is
blowing out warm
air
The dried air is passed over heating
coils before it is blown into the
room as part of the dehumidifying
process
This is normal,
a dehumidier is not
an air cooler
The display is not
showing the
humidity set point
The display shows the room relative
humidity not the set point
Press the humidity control
button once to see the
target relative humidity

120 MV-2568-03-2023 eeese-aircare.com © All rights eeese air care aps
UK
Water on oor
There is residual water in tank, and
the device is lurched too much by
moving
Be careful when moving
the tank
Water in tank
overows
The water tank may be
damaged.
Contact our eeese
customer service
Float for water auto-sensor
is not in place
Internal drainage passage
is blocked or obstructed
The dehumidier
is noisy
The pre-lter is blocked or the
device is on an uneven surface
Clean the pre-lter or put
the device on a at surface
Loose or foreign particles inside
the unit Contact our eeese
customer service
Sound of owing refrigerant
Error code E1: Temperature sensor error
E2: Humidity sensor error
Contact our eeese
customer service
Table of contents
Languages:
Other eeese Dehumidifier manuals
Popular Dehumidifier manuals by other brands

Beko
Beko DRYPOINT RS HP50 NA Series Instructions for installation and operation

SMC Networks
SMC Networks IDF60-20-A Operation manual

Fisher
Fisher F-DRY200AE owner's manual

GE
GE AHR30LM Dimensions and installation information

Morris
Morris MDD-10251W user manual

Anden
Anden A130F Installation and operating instructions

Arrow Pneumatics
Arrow Pneumatics BP-123 THROUGH BP-725 Instruction & maintenance manual

DAVIS
DAVIS Air-Dryr 1000 instructions

Danby
Danby DDR6511R1 Owner's use and care guide

Deltech
Deltech SPX FLOW HG Series instruction manual

Fortress Technologies
Fortress Technologies FDH3816 user manual

Beurer