Quick Guide
Clinican PCA Delivery

Review Preprogrammed Infusion Parameters � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �3
Change Infusion Parameters � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �4
Review Infusion Parameters During Infusion � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �5
Deliver Patient Bolus � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �6
Deliver Clinician Dose � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �7
Quit Clinician Dose� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �8
Start Loading Dose� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �9
Quit Loading Dose � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
This quick guide provides guidelines for the basic functionalities of the Avoset infusion pump, please refer to the user
manual and the training materials terms of use on our website: www.eitanmedical.com/term_training_materials/
Table of Content
PCA Infusion - Basic Functions
Avoset Quick Guide | Clinican PCA Delivery

3 | Avoset Quick Guide | Clinican PCA Delivery
Review Preprogrammed Infusion Parameters
Press the
REVIEW
multi-
function button to see the
infusion parameters
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
5th parameter:
The time between boluses
in which the user cannot
initiate a bolus
1st parameter (optional):
The drug concentration
3rd parameter:
The infusion rate between
boluses
2nd parameter:
The total volume to be
infused during the infusion
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
Based on the infusion programming, additional parameters may be displayed. Refer to the User Manual for further information.
Back to main display
(
REVIEW
option is available
again)
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
4th parameter:
The volume to be infused
in a single patient bolus
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
4.O
PRESS START
MEDICATION
REVIEW
1OO.O
4.O
PRESS START
MEDICATION
REVIEW
1OO.O
CONCENTRATION
1 MG/ML
NEXTBACK
4.O
CONTINUOUS
RATE
NEXTBACK
2.O
BOLUS AMOUNT
NEXTBACK
1OO
VTBI
NEXTBACK
OO:1S
LOCKOUT
DURATION
NEXTBACK
HOURS MINUTES
EDIT
EDIT
mg/h
mg/h
mg/h mg

4 | Avoset Quick Guide | Clinican PCA Delivery
Change Infusion Parameters
4. To edit the displayed parameter, use the
/ keys, and press
OK
. To keep the
parameter unedited, press
SKIP
1. If the infusion is
running, press to
pause the infusion
2. Press the
EDIT
multi-
function button
7. Press to resume
the infusion
8. Back to running
continuous rate
5. Press
NO
to nish
editing, or press
YES
to edit additional
parameters
6. Review the edited
parameters, to conrm
press
CONFIRM
, to
change press
EDIT
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
SET CONTINUOUS
DOSE RATE
SKIPBACK
4.O
mg/h
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2.O
SET CONTINUOUS
DOSE RATE
OKBACK
mg/h
3. The pump prompts
you to enter password.
Use the / keys
to set the three digits
and press the
OK
multi-function button
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
**O
ENTER PASSWORD
OKCLEAR
Editing a PCA infusion is possible before the infusion started or when the continuous rate is paused.
The changes apply to the current infusion and future repeated infusions.
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
4.O
MEDICATION
INFO
9S
EDIT
mg/h
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
4.O
MEDICATION
INFO
9S
C DOSE
mg/h
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2.O
MEDICATION
INFO
9S
EDIT
mg/h
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2.O
MEDICATION
INFO
9S
C DOSE
mg/h
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
EDIT MORE
PARAMETERS
NOYES
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2.O
CONFIRM CONT.
DOSE RATE
CONFIRMEDIT
The parameters that can be edited on the pump are: Continuous
Dose Rate, Bolus Amount and Lockout Duration, to edit other
parameters send a new program from the PC programming tool.
mg/h
mg/h

5 | Avoset Quick Guide | Clinican PCA Delivery
Review Infusion Parameters During Infusion
Press the
INFO
multi-
function button to
see the infusion
parameters
1st parameter:
Time remaining until a
bolus can be delivered.
*When a bolus is
available, this parameter
is not presented
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2nd parameter:
The total volume
infused so far
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
3rd parameter:
The remaining
volume
to be infused
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
Back to main display
(
INFO
option is
available again)
7th parameter:
The volume to be
infused in a single bolus
5th parameter:
The number of
requested boluses
and given boluses
6th parameter:
Continuous Rate
4th parameter:
The time elapsed since
bolus history was last
cleared
8th parameter (optional):
The drug concentration
Press
DONE
to nish
reviewing the
parameters
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
Bolus History Parameters
Based on the infusion programming, additional parameters may be displayed. Refer to the User Manual for further information.
Tip: long press on the
NEXT
multi-function button will return to home screen
BOLUS REQ.2
BOLUS GIV.1
NEXTCLEAR
4.O
CONTINUOUS
RATE
NEXT
2.O
BOLUS AMOUNT
NEXT
9S
CONCENTRATION
1 MG/ML
DONE
4.O
MEDICATION
INFO
9S
9S.O
VTBI
NEXT
S.O
VOLUME INFUSED
NEXT
OO:OS
LAST CLEAR OF
BOLUS HISTORY
NEXT
HOURS MINUTES
OO:12:S1
BOLUS
LOCKED OUT FOR
NEXT
HOURS MINUTES
C DOSE
SEC
mg/h
mg/h mg
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
4.O
MEDICATION
INFO
9S
C DOSE
mg/h

6 | Avoset Quick Guide | Clinican PCA Delivery
Deliver Patient Bolus
After delivering a bolus, a lockout period between boluses prevents the user
from requesting additional bolus until the lockout period elapses.
1. Press to initiate a bolus
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2. Bolus delivery indication
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
NORMAL SALINE
EDIT REVIEW
200
499.5
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
4.O
MEDICATION
INFO
98.S
DELIVERING
BOLUS...
98.2
BOLUS IS
LOCKED OUT
OK
CLINIC.B.
97.9
mg/h
Pressing the key will prompt this notication

7 | Avoset Quick Guide | Clinican PCA Delivery
Deliver Clinician Dose
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
5. Clinician dose delivery
indication
1. Press the
C DOSE.
multi-
function button to start
setting the clinician dose
3. Use the / keys
to change the value. Press
the
OK
multi-function
button to approve and
proceed
4. Press the
YES
multi-
function button to approve
and start delivering
clinician dose
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
4.O
MEDICATION
INFO
99.9
2.O
SET CLINICIAN
DOSE
OKBACK
DELIVERING
C.DOSE...
INFO
2.O
GIVE CLINICIAN
DOSE
YESNO
C DOSE
Clinician dose is an optional way for the clinician to add dose for the patient during a PCA treatment.
**O
ENTER PASSWORD
OKCLEAR
1.87
mg/h mgmg
2. The pump prompts you
to enter password. Use the
/ keys to set the
three digits and press the
OK
multi-function button

8 | Avoset Quick Guide | Clinican PCA Delivery
Quit Clinician Dose
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2. Press the
QUIT
multi-
function button to quit the
Clinician dose
3. Press the
YES
multi-
function button to quit the
Clinician dose
4. Press the
YES
multi-
function button to resume
the continuous rate
1. Press to pause the
Clinician dose
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
DELIVERING
C
.
DOSE
INFO
1.87 99.S
C.DOSE PAUSED
INFOQUIT
QUIT CLINICIAN
DOSE
YESNO
RESUME
CONT.RATE
YESNO
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
5. Back to running
continuous rate
4.O
MEDICATION
INFO
99.S
C DOSE
mg/h

9 | Avoset Quick Guide | Clinican PCA Delivery
Start Loading Dose
A Loading Dose is an optional clinician dose given when starting the rst infusion right after programing.
Loading Dose is part of the program and is available only when the rst infusion is delivered.
When repeating the same infusion, the infusion will start with the continuous rate.
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
2. Loading Dose delivery
indication
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
1. Press to start the
Loading Dose
DELIVERING
L.DOSE. . .
INFO
99.S
4.
O
PRESS START
MEDICATION
REVIEW
1OO
EDIT
mg/h

10 | Avoset Quick Guide | Clinican PCA Delivery
Quit Loading Dose
1. Press to pause the
Loading Dose
2. Press the
QUIT
multi-function
button to quit Loading Dose 3. Press the
YES
multi-function
button 4. Back to continuous rate
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
+
–
START
BOLUS
PRIME
PAUSE
ON/OFF
GO
RUN
ALARM
DELIVERING
L.DOSE. . .
INFO
99.S
4.
O
MEDICATION
INFO
99.S
LOADING DOSE
PAUSED
INFO
99.S
QUIT
QUIT
LOADING DOSE
?
YESNO EDIT
mg/h

11 | Avoset Quick Guide | Clinican PCA Delivery
This page is left intentionally blank
Disclaimers

Eitan Medical Ltd.
29 Yad Haruzim St.
P.O. Box 8639
Netanya 4250529, Israel
REPEC
Avoset English Clinician Quick Guide PCA | 15132-048-0005-UM, Rev.02
MedNet EC-REP llb GmbH
Borkstrasse 10
48163 Münster, Germany
Other manuals for avoset
1
Table of contents
Other eitan medical Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Nonin
Nonin 8000AA quick guide

RHINO
RHINO OLYMPUS ENF-VH2/V4 Cleaning & Disinfection Guide

AQUA-RELIEF
AQUA-RELIEF ARS-2000D operating instructions

OrthoSensor
OrthoSensor VERASENSE user guide

DeVilbiss Healthcare
DeVilbiss Healthcare 7305 Series Instruction guide

Richard Wolf
Richard Wolf 2271 instruction manual

E-Pill
E-Pill MedSmart Voice Plus instruction manual

Stryker
Stryker IsoFlex LAL 2860 Operation & maintenance manual

Accu-Chek
Accu-Chek D-TRONplus Reference manual

Ossur
Ossur LOCKING KNEE Instructions for use

OAKWORKS
OAKWORKS QuickLock instructions

Instrumentarium
Instrumentarium ORTHOPANTOMOGRAPH OP300 quick guide