manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elkay
  6. •
  7. Chiller
  8. •
  9. Elkay ERW32-1C User manual

Elkay ERW32-1C User manual

Other Elkay Chiller manuals

Elkay ECP8*1H Series Installation manual

Elkay

Elkay ECP8*1H Series Installation manual

Elkay HRC4-19-1C User manual

Elkay

Elkay HRC4-19-1C User manual

Elkay ECH8*1F Installation manual

Elkay

Elkay ECH8*1F Installation manual

Elkay ER2 Installation manual

Elkay

Elkay ER2 Installation manual

Elkay ECU8 1H Series Installation manual

Elkay

Elkay ECU8 1H Series Installation manual

Elkay ER19 User manual

Elkay

Elkay ER19 User manual

Elkay ECH8 1J Series Installation manual

Elkay

Elkay ECH8 1J Series Installation manual

Elkay ER10*1D User manual

Elkay

Elkay ER10*1D User manual

Elkay ECP8-2GQ Installation manual

Elkay

Elkay ECP8-2GQ Installation manual

Elkay ECP8 1H Series Installation manual

Elkay

Elkay ECP8 1H Series Installation manual

Elkay HRC32W User manual

Elkay

Elkay HRC32W User manual

Elkay HRC30-1B User manual

Elkay

Elkay HRC30-1B User manual

Elkay ECH8 2K Series Installation manual

Elkay

Elkay ECH8 2K Series Installation manual

Elkay ECP8 2H Series Installation manual

Elkay

Elkay ECP8 2H Series Installation manual

Elkay ERC8-1B/2B User manual

Elkay

Elkay ERC8-1B/2B User manual

Elkay ER5 Series Instructions for use

Elkay

Elkay ER5 Series Instructions for use

Elkay ECU8*1H Series Installation manual

Elkay

Elkay ECU8*1H Series Installation manual

Elkay ER10.2C User manual

Elkay

Elkay ER10.2C User manual

Elkay ECU8*1B Installation manual

Elkay

Elkay ECU8*1B Installation manual

Elkay ERS1 1E Series Installation manual

Elkay

Elkay ERS1 1E Series Installation manual

Elkay HRC2-10-1D User manual

Elkay

Elkay HRC2-10-1D User manual

Elkay ERS1 2E Series Installation manual

Elkay

Elkay ERS1 2E Series Installation manual

Elkay ER194H Installation manual

Elkay

Elkay ER194H Installation manual

Elkay ER52Y Installation manual

Elkay

Elkay ER52Y Installation manual

Popular Chiller manuals by other brands

Trane RTAA-70 Installation & maintenance guide

Trane

Trane RTAA-70 Installation & maintenance guide

Carrier Omnizone 50BVC Installation, Start-Up, Service and Controls Operation and Troubleshooting

Carrier

Carrier Omnizone 50BVC Installation, Start-Up, Service and Controls Operation and Troubleshooting

York YGWH 115 Installation, commissioning & operation

York

York YGWH 115 Installation, commissioning & operation

Galletti PERFORMA MPE Series Technical manual

Galletti

Galletti PERFORMA MPE Series Technical manual

SMC Networks HRR Series manual

SMC Networks

SMC Networks HRR Series manual

Daikin EWAQ016CAW Installation and operation manual

Daikin

Daikin EWAQ016CAW Installation and operation manual

Trane CVHE Troubleshooting

Trane

Trane CVHE Troubleshooting

Moffat Friginox TSR-11SC Specification sheet

Moffat

Moffat Friginox TSR-11SC Specification sheet

Gree GWH07AGA-K6DNA1C Service manual

Gree

Gree GWH07AGA-K6DNA1C Service manual

MP Systems PURGE Series manual

MP Systems

MP Systems PURGE Series manual

Penguin COLD THERAPY CHILLER owner's manual

Penguin

Penguin COLD THERAPY CHILLER owner's manual

Telemark TVP-2000 Operation, installation and service manual

Telemark

Telemark TVP-2000 Operation, installation and service manual

TICA MINI VRF CHR Series Installation & operation manual

TICA

TICA MINI VRF CHR Series Installation & operation manual

MAXA A68 Installation and operation manual

MAXA

MAXA A68 Installation and operation manual

AERMEC NRL FC 2000 installation manual

AERMEC

AERMEC NRL FC 2000 installation manual

SABROE ChillPAC operating manual

SABROE

SABROE ChillPAC operating manual

Aqua Optima Corona Instructions for use

Aqua Optima

Aqua Optima Corona Instructions for use

Nordcap SKF 5 GN 1 manual

Nordcap

Nordcap SKF 5 GN 1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

97657C (REV. G - 8/03)
ERW32-1C
1. This unit is intended for remote installation only. It is important to insure proper ventilation. A minimum of 6 inches
(152mm) to the front must be maintained, and 6 inches (152mm) to the rear of the unit.
2. This chiller has been designed for use with potable water and includes an o-ring seal on the drain plug. This
fitting should be replaced if the unit is to be used with more aggressive fluids.
3. Installer to provide air gap at condenser water outlet to comply with local plumbing specifications.
4. Connecting lines to be made of copper. Thoroughly flush all lines to remove all foreign matter before connecting to
cooler. If flushing does not remove all particles, a water strainer should be installed in the supply line.
5. Connect cooler to building supply with a shut-off valve and install a union connection between the valve and the
cooler.
6. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate.
Never wire the compressor directly to the power supply.
ERW32-1C
Refrigeration Packages
Installation Instructions
LEGEND
A = 3/8" O.D. TUBE WATER INLET
B = 3/8" O.D. TUBE WATER OUT
C = TEMPERATURE ADJUSTMENT
D = ELECTRICAL
E = 3/8" O.D. TUBE TANK DRAIN
F = 3/8" O.D. TUBE CONDENSER WATER OUTLET
G = 3/8" O.D. TUBE CONDENSER WATER INLET
H = FREEZE CONTROL
INSTALLATION
NOTICE: This water cooler must be connected to the water supply using a dielectric coupling.
97657C (REV. G - 8/03)
ERW32-1C
DESCRIPTION
28165C
28218C
28166C
28032C
23158C
26701C
34783005
35882C
66633C
36034C
30768C
35985C
35984C
35989C
35988C
35990C
30039C
50196C
66624C
70772C
66621C
70020C
66623C
30040C
36045C
70482C
70274C
70483C
35895C
1
2
3
4
5
6
7
8
9
10
11
*12
13
14
15
16
18
19
20
21
22
23
24
25
26
27
28
29
30
PART NO.
BOX - INSULATION
BASE ASSY
PANEL
PANEL - FRONT/REAR
COVER - INSULATION BOX
CABINET
WASHER - LOCK
CONTROL - COLD
CONDENSER ASSY
CSIR BOX ASSY
SOLENOID VALVE
COMPRESSOR SERVICE PAK
OVERLOAD
GASKET - TERM COVER
OVERLOAD SPRING
BALE STRAP
ELECTRICAL BOX
GROMMET - COMPRESSOR MTG
EVAPORATOR ASSY
EVAPORATOR DRAIN PLUG
DRIER
NUT
HEAT EXCHANGER
ELECTRICAL BOX COVER
OVERLOAD COVER
MALE CONNECTOR FITTING
SLEEVE-COMPRESSOR
ELBOW FITTING
FREEZE CONTROL
ITEM NO.
PARTS LIST
*INCLUDES COMPRESSOR, CSIR BOX ASSY, & OVERLOAD. IF UNDER
WARRANTY REPLACE WITH SAME COMPRESSOR USED IN
ORIGINALASSEMBLY.
NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF THE ABOVE
WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE
MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF
REPLACEMENT PART.
NOTE: FOR USE WITH PHOTO PROCESSING APPLICATIONS,
ADJUST THERMOSTAT TO WARMER SETTINGS.
ELKAY MANUFACTURING COMPANY2222 CAMDEN COURTOAK BROOK, IL 60521630.574.8484TELEX: RCA 289234
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
The grounding of electrical equipment such as telephone, computers, etc., to water
lines is a common procedure. This grounding may be in the building, or may occur
away from the building. This grounding can cause electrical feedback into a water
chiller, creating an electrolysis which causes a metallic taste or an increase in the
metal content of the water. This condition is avoidable by using the proper materials
indicated below. Drain fittings which are provided by the installer should be plastic to
electrically isolate the chiller from the building plumbing system.
Temperature Control: Factory set for 50°F water under normal conditions. To
adjust water temperature, turn screw on Item No. 8 clockwise for colder, counter
clockwise for warmer.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with
a brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no
cold water and compressor cycling on the overload protector.
Lubrication: Motors are lifetime lubricated.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free
plug which utilizes an o-ring seal. To remove plug from cooler, relieve water
pressure, pull the collar towards the fitting and pull the fitting off the tube. To install
plug, push fitting straight onto tubing until it reaches a positive stop, approximately
3/4.
IMPORTANT! INSTALLER PLEASE NOTE:
TROUBLE SHOOTING & MAINTENANCE
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which
cooler is connected. A steady stream flow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
TUBE IS SECURED
IN POSITION
SIMPLY PUSH IN
TUBE TO ATTACH
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
19, 28
21 11 9
1
564
7, 20, 23
822
2
3
13, 14, 15, 16, 26
10
24
12
27, 29
18, 25
30