ELPRO ECOLOG-PRO 2PTR User manual

PM | MASCHL
1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 1 / 15
ECOLOG-PRO
Radio Modules
ECOLOG-PRO 2PTR
ECOLOG-PRO 1THR
Operation Manual

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 2 / 15
Contents
1. System Overview.............................................................................................................................. 4
2. Measurement Module ECOLOG-PRO 2PTR...................................................................................... 5
3. Measurement Module ECOLOG-PRO 1THR ..................................................................................... 8
4. Disposal .......................................................................................................................................... 12
5. Declaration of Conformity.............................................................................................................. 13

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 3 / 15
Conformity and Symbols Used
Hereby, ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 2PTR
868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available in chapter 5 of this document or at the following internet address:
https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOG-
PRO_2PTR_DOC_Conformity_1000279V01.pdf
Hereby, ELPRO-BUCHS AG declares that the radio equipment type ECOLOG-PRO 1THR
868 MHz is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity
is available in chapter 5 of this document or at the following internet address:
https://www.elpro.com/fileadmin/Docs/Quality_Documents/ECOLOG-
PRO_1THR_DOC_Conformity_1000281V01.pdf
Above mentioned products operate in the 863-870MHz band with a maximum radiated output power
of +11.6dBm.
ECOLOG-PRO 2PTR 915 MHz and ECOLOG-PRO 1THR 915 MHz
Above mentioned devices comply with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Above mentioned devices operate in the 902-928MHz band with a maximum radiated output power
of +4dBm.
ECOLOG-PRO 2PTR 915 MHZ contains
FCC ID: S9NSPSGRFC
IC: 8976C-SPSGRFC
ECOLOG-PRO 1THR 915 MHz contains
FCC-ID: S9NSPSGRFC
IC: 8976C-SPSGRFC
Devices have to be disposed of according to WEEE (Waste Electrical and Electronic Equipment,
2002/96/EC).

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 4 / 15
1. System Overview
The ECOLOG-PRO measurement and communication modules described in this document
are used for temperature monitoring. The measured values are transmitted to a monitoring software
(ELPRO Cloud), which stores and analyzes the data, provides alerts if alarm limits are violated, and
generates reports. The system provides superior visibility and transparency in meeting GxP
requirements. The sensor-based monitoring software is easily accessible via a web browser and is also
used to configure the measurement modules and sensors.
The following pages contain key features and technical specifications of ECOLOG-PRO 2PTR and
ECOLOG-PRO 1THR. In addition, you will find information on how to connect the modules.
For detailed software and connection support, please visit our online knowledge base:
https://www.elpro.cloud/support/elpro-cloud
* module covered in this document

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 5 / 15
2. Measurement Module ECOLOG-PRO 2PTR
Functional characteristics:
ECOLOG-PRO 2PTR is a measurement module with two external temperature sensors. Communication
from this module with the ECOLOG-PRO RBR is via radio signal.
Power supply
3 AA Alkaline batteries
SAFETY INSTRUCTIONS!
Improper use or misuse of batteries may result in leakage of battery fluid or, in
the worst case, explosion and/or fire. Please note:
Always choose the correct type of battery that best suits your intended
use (see 'Measurement range').
So that battery status can be determined correctly, always insert new,
unused batteries when changing batteries.
Never insert different types of batteries into the device at the same
time.
All batteries should be replaced at the same time. Mixing old and new
batteries may cause the batteries to leak and damage the product.
Make sure that the battery contacts and mating contacts in the device
are clean before inserting the batteries.
Make sure that the batteries are inserted properly i.e. observe polarity
(+ and -).
Remove the batteries if you are not going to use the product for a
longer period of time to avoid damage from leakage. Leaking or
damaged batteries can cause acid burns on skin contact. When handling
damaged batteries, you should wear protective gloves.
Remove expired batteries immediately from the device.
Do not disassemble batteries, do not short-circuit them and do not
throw them into fire. Never try to charge non-rechargeable batteries.
There is a danger of explosion!
Keep batteries out of reach of children. Do not leave batteries lying
around as they may be swallowed by children or pets.
Battery life
14 months (provided that the module's radio connection is stable and that the
defined temperature range (see below) is maintained)
Measurement range
-200 °C..+200 °C
Measurement resolution
0.1 °C
Measurement accuracy
+/-0.2 °C
Logging and communication interval
1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software (ELPRO
Cloud)
NOTE: Logging interval will impact battery life
Channels
2 independent temperature channels with separately connected sensors
Probe type
External 4-wire Pt100 probe

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 6 / 15
Probe connection
Standard probe: Pt100 temperature sensor, 3m cable, no shielding
Extension: maximum 17 meters, no shielding
Memory capacity
43'000 measurement values
Environmental storage temperature /
humidity
-10 °C..+50 °C
10 %RH..90 %RH, non-condensing
Environmental operating temperature
/ humidity
0 °C..+40 °C
10 %RH..90 %RH, non-condensing
Operating altitude
This device must not be used at altitudes higher than 2000 meters above sea
level.
ID number
"Q" followed by a 6-digit number; the ID number is used to identify the module in
the ELPRO Cloud software.
Radio connection to communication
module
Available in two versions: 868 MHz (Europe) or 915 MHz (US)
Note: Only the supplied antenna may be used.
Left LED (Link):
Red flashing light: ECOLOG-PRO 2PTR is active but is not connected to a
communication module (ECOLOG-PRO RBR)
Green flashing light: ECOLOG-PRO 2PTR is active and connected to a
communication module (ECOLOG-PRO RBR)
The interval of the flashing light is 10s.
Right LED (Data):
Red flashing light: Measurement on one or both channels has started. There are
one or more failures in measurement.
Green flashing light: Measurement on one or both channels has started.
Everything is OK.
The interval of the flashing light is 10s.

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 7 / 15
How to connect
Make sure that you have defined the sensor's settings in the ELPRO Cloud software and that the "Add
sensor" wizard shows the image displayed above. This gives you a 10 minutes time frame to connect
your module via the following steps:
1. Remove the screw on the front and open the measurement module's cover.
2. Insert the three AA batteries.
3. Bring the measurement module ECOLOG-PRO 2PTR in close proximity (approximately 10 cm) to an
ECOLOG-PRO RBR connected to ELPRO Cloud.
4. Press and hold the "Connect" button inside the measurement module for more than 3 seconds. The
left LED will blink red 3 times.
4a. Wait until the left LED starts flashing red (once per second).
4b. A successful connection will be indicated by the left LED illuminating in green for 10 seconds.
Afterwards, the left LED will be flashing green every 10 seconds.
5. Close the communication module's cover and tighten the screw. Place the module in its intended
location (e.g. storage room, next to your ultra-freezer or cryo container, etc.).

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 8 / 15
3. Measurement Module ECOLOG-PRO 1THR
front view bottom view
Functional characteristics:
ECOLOG-PRO 1THR is a measurement module with one external combination probe for temperature
and relative humidity. Communication from this module with the ECOLOG-PRO RBR is via radio signal.
Power supply
3 AA Alkaline batteries
SAFETY INSTRUCTIONS!
Improper use or misuse of batteries may result in leakage of battery fluid or, in
the worst case, explosion and/or fire. Please note:
Always choose the correct type of battery that best suits your intended
use (see 'Measurement range').
So that battery status can be determined correctly, always insert new,
unused batteries when changing batteries.
Never insert different types of batteries into the device at the same
time.
All batteries should be replaced at the same time. Mixing old and new
batteries may cause the batteries to leak and damage the product.
Make sure that the battery contacts and mating contacts in the device
are clean before inserting the batteries.
Make sure that the batteries are inserted properly i.e. observe polarity
(+ and -).
Remove the batteries if you are not going to use the product for a
longer period of time to avoid damage from leakage. Leaking or
damaged batteries can cause acid burns on skin contact. When handling
damaged batteries, you should wear protective gloves.
Remove expired batteries immediately from the device.
Do not disassemble batteries, do not short-circuit them and do not
throw them into fire. Never try to charge non-rechargeable batteries.
There is a danger of explosion!
Keep batteries out of reach of children. Do not leave batteries lying around as
they may be swallowed by children or pets.
Battery life
14 months (provided that the module's radio connection is stable and that the
defined temperature range (see below) is maintained)

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 9 / 15
Measurement range and accuracy
Sensor data (page 11)
Measurement resolution
0.1 °C
Logging and communication interval
1, 2, 3, 5, 10, 15, 20, 30, 60 minutes; user programmable via software (ELPRO
Cloud)
NOTE: Logging interval will impact battery life
Channels
2 channels (1x temperature / 1x humidity)
Probe type
Digital probe
Probe connection
Digital 3-PIN combination probe
Extension: maximum 30 meters, no shielding
Memory capacity
43'000 measurement values
Environmental storage temperature /
humidity
-10 °C..+50 °C
10 %RH..90 %RH, non-condensing
Environmental operating temperature
/ humidity
0 °C..+40 °C
10 %RH..90 %RH, non-condensing
Operating altitude
This device must not be used at altitudes higher than 2000 meters above sea
level.
ID number
"R" followed by a 6-digit number; the ID number is used to identify the module in
the ELPRO Cloud software.
Radio connection to communication
module
Available in two versions: 868 MHz (Europe) or 915 MHz (US)
Note: Only the supplied antenna may be used.
Left LED (Link):
Red flashing light: ECOLOG-PRO 1THR is active but is not connected to a
communication module (ECOLOG-PRO RBR)
Green flashing light: ECOLOG-PRO 1THR is active and connected to a
communication module (ECOLOG-PRO RBR)
The interval of the flashing light is 10s.
Right LED (Data):
Red flashing light: Measurement on one or both channels has started. There are
one or more failures in measurement.
Green flashing light: Measurement on one or both channels has started.
Everything is OK.
The interval of the flashing light is 10s.

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 10 / 15
How to connect
Make sure that you have defined the sensor's settings in the ELPRO Cloud software and that the "Add
sensor" wizard shows the image displayed above. This gives you a 10 minutes time frame to connect
your module via the following steps:
1. Remove the screw on the front and open the measurement module's cover.
2. Insert the three AA batteries.
3. Bring the measurement module ECOLOG-PRO 1THR in close proximity (approximately 10 cm) to an
ECOLOG-PRO RBR connected to ELPRO Cloud.
4. Press and hold the "Connect" button inside the measurement module for more than 3 seconds. The
left LED will blink red 3 times.
4a. Wait until the left LED starts flashing red (once per second).
4b. A successful connection will be indicated by the left LED illuminating in green for 10 seconds.
Afterwards, the left LED will be flashing green every 10 seconds.
5. Close the communication module's cover and tighten the screw. Place the module in its intended
location (e.g. laboratory, storage room, etc.).

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 11 / 15
Sensor data
Dimensional view of the two variants: temperature / humidity sensor
Part. No. 802209
Temperature & humidity sensor, capacitive
This sensor is designed to monitor storage rooms, laboratories or for general
room-climate monitoring.
Specifications
Measurement range
Humidity: 20 %RH..80 %RH
Temperature: -20 °C..80 °C
Humidity accuracy
15.0 °C..30.0 °C
±2.0 %RH
Temperature accuracy
65.0 °C..80.0 °C
±0.5 C
0.0 °C..64.9 °C
±0.3 C
-20.0 °C..-0.1 °C
±0.5 C
Drift Humidity sensor
Typically 3.0 %RH / year
Part. No. 802071
Temperature / humidity sensor, electrolytic
This sensor is designed for:
Environments with aggressive gases at high temperature and air humidity
(stability chambers, incubators)
Low-temperature environments (refrigerator)
High-precision measurements of ±0.5 %RH
Specifications
Measurement range
Humidity: 0 %RH..100 %RH
Temperature: -20 °C..80 °C
Humidity accuracy
50.0 °C..80.0 °C
±2.5 %RH
30.0 °C..49.9 °C
±0.8 %RH
15.0 °C..29.9 °C
±0.5 %RH
0.0 °C..14.9 °C
±0.8 %RH
-20.0 °C..-0.1 °C
±2.5 %RH
Temperature accuracy
70.0 °C..80.0 °C
±0.2 C
0.0 °C..69.9 °C
±0.1 C
-20.0 °C..-0.1 °C
±0.2 C
Drift Humidity sensor
Typically 1.0 %RH / year

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 12 / 15
4. Disposal
a) Product
Electronic devices are recyclable and do not belong in the household waste.
Dispose of the product at the end of its service life in accordance with applicable
laws. Remove any batteries and dispose of them separately from the product.
b) Batteries
You are legally obliged to dispose of all used batteries according to applicable laws;
disposal via household waste is prohibited. Batteries categorized as containing
hazardous material are marked with the adjacent symbol, under which is printed
the chemical symbol for the heavy metal (Cd = cadmium, Hg = mercury, Pb = lead)
used. You can dispose of used batteries at collection points in your local
community. Please help protect our environment and dispose of batteries properly.

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 13 / 15
5. Declaration of Conformity

1000465V01 DOC - ECOLOG-PRO 2PTR and 1THR - Operation Manual_EN.docx | Page 14 / 15
This manual suits for next models
1
Table of contents
Other ELPRO Control Unit manuals