ELRO FZ5002R User manual

INTENDED USE: FIRE SAFETYESSENTIAL CHARACTERISTICS: PASSED Nominal acvaon condions / Sensivity, Response delay (response me) and Performance under fire condion - Operaonal reliability - Tolerance to supply voltage - Durability of operaonal reliability and response delay, temperature resistance, vibraon resistance, humidity resistance, corrosion resistance, electrical stability. Instrucon manualEN Smoke alarm Heat detecon, wireless connected Anleitungshandbuch DE Rauchwarnmelder Wärmemeldung, Drahtlos verbunden GebruiksaanwijzingNL Rookmelder Hiedetece, sraadloos koppelbaar Manuel d'ulisaonFR Détecteur de fumée Détecon de chaleur, sans fil connectéEU - QUALITY-1-Home is not a place, it’s a feelingFZ5002R
Attic / DachbodenZolder / Grenier
Ground floor / ErdgeschossBegane grond / Rez de chausséeFirst floor / Erste EtageEerste verdieping / Premier étageMinimumExtraEntree0359
DoP: FZ5002R-01
17 FZ5002REN 14604:2005 + AC:2008Fire SafetyImporter: ELRO Europe | www.elro.euPostbus 9607 - Box E8001006 GC Amsterdam The NetherlandsManufacturerSiterwell Electronics CO., Limited No.666 Qingfeng Road, Jiangbei District, Ningbo, Zhejiang Province, China 315034 DE - Symbole: Recycling und Entsorgung: Das WEEE-Symbol (a) bedeutet, dass dies Produkt und seine Batterien separat von anderem Haushaltsmüll entsorgt werden muss. Wenn das Ende der Produktlebensdauer erreicht ist, bringen Sie das Produkt zur kommunalen Sammelstelle um eine sichere Entsorgung oder Recycling zu gewährleisten. Schützen Sie Umwelt und menschlichen Gesundheit und gehen Sie verantwortlich mit natürlichen Ressourcen um! Lesen Sie vor Gebrauch das Anleitungshandbuch (b) und heben Sie diese auf, um eine sichere Nutzung und Wartung zu gewährleisten. Herunterladen (c) Leistungserklärung (DoP). Hiermit erklärt ELRO Europe, dass der Funkanlagentyp FZ5002Rder Richtlinie 2014/53/EU entspricht. Der vollständige Text der EU-Konformitätserklärung ist unter der folgenden Internetadresse verfügbar: www.elro.eu/compliance Warnung: Um Verletzungsgefahren vorzubeugen muss dies Gerät sicher nach Anleitungshandbuch an der Decke montiert werden. Batterien dürfen keiner starken Hitze ausgesetzt werden, wie z.B. durch direkte Sonnen-einstrahlung, Feuer, etc. Batterielebensdauer verkürzt sich ohne monatlichen Test. Von der Klimaanlage/Belüftung fernhalten. Nicht bemalen oder das Gerät abdecken. Bitte beachten Sie örtlichen Vorschriften.Problembehandlung: Fehlalarme werden meist durch Staub oder Dunst ausgelöst. Im Zweifelsfall: Verlassen das Gebäude und Maßnahmen ergreifen! Zusätzliche Montagehinweise: Flure mit max. Breite 3m: Max. 15m zwischen 2 Meldern. Max. 7,5m zur Stirnfläche des Flures und Melder In Kreuzungs-, Einmündungs- und Eckbereichen von Fluren. Galerien: Länge und Breite >2m und >16m², weiterer Rauchwarnmelder unterhalb Galerie. Anteiligen Dachschrägen: Horizontale Decke ≤1m breit, wie bei Dachschrägen. Horizontale Decke >1m breit, wie bei horizontale Decken.NL - Symbolen: Recycling en afvoer: Het WEEE-symbool (a) betekent dat dit product en batterijen gescheiden van huishoudelijk afval moeten worden afgevoerd. Als dit product het einde van zijn levensduur bereikt, breng je het naar een aangewezen afvalinzamelpunt in de buurt om een veilige afvoer of recycling te garanderen. Bescherm milieu en volksgezondheid, ga verantwoordelijk met natuurlijke hulpbronnen om! Lees de handleiding (b) voor gebruik en bewaar hem op een veilige plek voor toekomstig gebruik en onderhoud. Download (c) Verklaring van Prestaties (DoP). Hierbij verklaar ik, ELRO Europe, dat het type radioapparatuur FZ5002R conform is met Richtlijn 2014/53/EU. De volledige tekst van de EU-conformiteitsverklaring kan worden geraadpleegd op het volgende internetadres: www.elro.eu/compliance Waarschuwingen: Om verwondingen te voorkomen, moet dit apparaat stevig aan het plafond bevestigd zijn volgens de installatievoorschriften. Batterijen mogen niet blootgesteld worden aan extreme hitte zoals zonlicht en vuur. Levensduur batterij verkort zonder maandelijkse testen. Niet monteren in de nabijheid van airconditioning/ventilatie. Verf of bedek het apparaat niet. Raadpleeg de lokale voorschriften. Probleemoplossing: Vals alarm wordt vaak veroorzaakt door stof of stoom. Bij twijfel: Verlaat het pand en onderneem actie! Aanvullende installatieinstructies: Gangen met max. breedte 3m: Max. 15m tussen 2 detectoren. Max 7,5m afstand tot voorzijde en detectors in hoeken en kruisingen van gangen. Galerijen: Lengte en breedte >2m en >16m², extra detector onder galerij. Gedeeltelijke dakhelling: Vlak plafond ≤1m breed, beschouw als hellend dak. Vlak plafond >1m breed, beschouw als vlak plafond. EN - Symbols: Recycling and disposal: The WEEE symbol (a) means that this product and batteries must be disposed separately from other household waste. When it reaches its end of life, take it to a designated waste collection point in your area to guarantee a safe disposal or recycling. Protect the environment, human health and natural resources! Read the manual (b) before use and store it in a safe place for future use and maintenance. Download (c) Declaration of Performance (DoP). Hereby, ELRO Europe declares that the radio equipment type FZ5002R is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.elro.eu/compliance Warnings: To prevent injury, this apparatus must be securely attached to the ceiling in accordance with the installation instructions. Batteries shall not be exposed to excessive heat such as sunshine and fire. Battery lifetime shortens without monthly test. Keep away from air conditioning/ventilation. Do not paint or cover alarm. Consult local regulations. Troubleshooting: False alarm is often caused by dust or steam. In case of doubt: Leave the building and take action! Additional mounting instructions: Corridor max width 3m: Max 15m between 2 alarms. Max. 7,5m to front side and alarms at edges/crossings of corridors. Galleries: Length and width >2m and >16m², additional alarms below gallery. Partial roof slopes: Flat ceiling ≤1m wide, consider as roof slope. Flat ceiling >1m wide, consider as flat ceiling.FR - Symbols: Recyclage et mise au rebut: Le symbole WEEE (a) signifie que ce produit et batteries ne doivent pas être jeté avec les ordures. Une fois le produit arrivée en fin de vie, déposez-la au centre de tri le plus proche de chez vous, où elle sera mise au rebut ou recyclée en toute sécurité. Protéger l'environnement, la santé des personnes et des ressources naturelles! Veuillez lire attentivement le manuel (b) avant utilisation et le conserver à un endroit sûr. Déclaration de Performance (c) (DoP). Le soussigné, ELRO Europe, déclare que l'équipement radioélectrique du type FZ5002R est conforme à la directive 2014/53/UE. Le texte complet de la déclaration UE de conformité est disponible à l'adresse internet suivante: www.elro.eu/compliance Avertissements: Pour éviter toute blessure, cet appareil doit être solidement fixé au plafond conformément aux instructions d'installation. Les piles ne doivent pas être exposées à une chaleur excessive comme l'ensoleillement et le feu. Durée de vie de la batterie raccourcit sans test mensuel. Tenir à l'écart de l'air conditionné/ventilation. Ne pas peindre ou couvrir un appareil. Consultez les règlements locaux. Dépannage: Fausse alarme est souvent causée par la poussière ou la vapeur. En cas de doute: Quittez le bâtiment et prendre des mesures! Instructions de montage supplémentaires: Couloir max. largeur 3m: Max 15m entre 2 détecteurs. Max. 7,5m à l'avant et détecteurs aux bords / traversées de couloirs. Galeries: Longueur et largeur >2m et >16m², détecteurs supplémentaire en dessous de la galerie. Inclinaisons partielles du toit: Plafond plat ≤1m large, considérons comme une pente de toit. Plafond plat >1m large, considérons comme un plafond plat.(a)(b)Download(c)
Document nr.: FZ500221R_MNL | Revision nr. : 11 | Revision date: 28-9-2020Max. transmission power: 10dBmMax. Emissionsleistung: 10dBmMax. puissance de transmission: 10dBmMax. radiofrequent vermogen: 10dBmFrequency: 868MHz.

85dB(A)+1x 50 sec1RemoveEnernenVerwijderenRererWhen LED OFFWenn LED AUS istWanneer LED UITLorsque LED OFFClear code - Code löschen Code wissen - Effacer le code Press and holdDrücken und haltenHoud ingedruktAppuyez et maintenezInsert baeriesBaerien einlegenPlaats baerijenInsérer des piles234Release and press againFreigeben und erneut drückenLaat los en druk opnieuwRelâchez et appuyez nouveau85dB(A)= ü1. Content - Inhalt - Inhoud - Contenu2. Acvate / Replace - Akvieren / Ersetzen - Acveren / Vervangen - Acvé / Remplacer3. Tesng - Prüfung - Testen - Testez4. Connect/Learning - Verbinden/Lernen - Koppelen/Inleren - Connexion/Apprenssage Press Druck Druk Appuyer Press Druck Druk Appuyer 3x3x85dB(A) = üAB5a Rooms - Zimmer - Kamers - Chambre Min 50cm Min 50cm XX0-20°1/21/2Min. 1x / 40 m²Height - Höhe - Hoogte - Hauteur max. 6m5b Roof - Dach - Dak - Toit5c Beams - Balken - Balken - Poutres6. Test & clean - Testen & reinigen Test & reinigen - Testez & neoyage7. Hush-Stummschalten-Uitstellen-Pause
Min 50cm Min 50cm
X20°>
XX
ü
20°>Min. 1x / 20-40 m²0,2m
>
üü
X
ü
0,2m>Test not okay, replace alarmTest nicht ok, Melder ersetzen!Test niet goed, vervang detector!Test échoue, remplacez le détecteur!1x MONTH123456781017161514131211242322212019183130292827262591x / 16sec10 min85dB(A)!EN Low baery alert? Replace baery and test! (see 2 and 3). Mute warning for 10 hours: press test buonDE Niedriger Baerie-Alarm? Baerien austauschen und Testen! (Sehe 2 und 3). Stummschaltung für 10 Stunden: Drücken Sie die TesasteNL Melding lage baerijspanning? Vervang baerijen en test! (zie 2 en 3). Melding dempen voor 10 uur: druk op de testknop FR Alerte de baerie faible? Remplacez la pile et test! (voir 2 et 3). Averssement de mise en sourdine pendant 10 heures: appuyez sur le bouton de test.
85dB(A)-2-2x 1,5V DC AA
Other ELRO Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

Arrowhead Alarm Products
Arrowhead Alarm Products VST-LS881AH Operation

Hochiki
Hochiki FireNET L@titude Series Information guide

Siemens
Siemens 5TC1292-6 user manual

Safetec
Safetec SDS-2/6 Additional Fault Finding Instructions

C-TEC
C-TEC FP4E installation instructions

LST
LST AO-55000-620 Specification sheet