Important safety information
Read this manual before attempting to install the device!
Failure to observe recommendations included in this manual may be
dangerous or cause a violation of the law. The manufacturer, Elektroniksystem i
Umeå AB will not be held responsible for any loss or damage resulting from not
following the instructions of this operating manual.
•The device must not be dismantled or modified in any way.
•The device is only intended for indoor use. Do not expose it to moisture.
•The device is not intended to be used as a reference sensor, and
Elektroniksystem i Umeå AB will not be held liable for any damage which
may result from inaccurate readings.
•The battery should be removed from the device if it is not to be used for
an extended period. Otherwise, the battery might leak and damage
the device. Never leave a discharged battery in the battery
compartment.
•The device must never be subjected to shocks or impacts.
•To clean the device, wipe with a soft moistened cloth. Use another soft,
dry cloth to wipe dry. Do not use any detergent or alcohol to clean the
device.
Disposal note in accordance with ElektroG and WEEE Directive
2012/19/EU
The device, as well as all the individual parts, must not be disposed of
with household waste or industrial waste. You are obliged to dispose of
the device at the end of its service life in accordance with the
requirements of ElektroG in order to protect the environment and to reduce
waste through recycling. For additional information and how to carry out
disposal, please contact the certified disposal service providers. The sensors
contain a lithium battery, which must be disposed of separately.

3
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Contents
Description......................................................................................................................................... 4
Main features of EMS Door ...................................................................................................... 5
Installation.......................................................................................................................................... 6
Door activity sensor.................................................................................................................... 7
Sensor configuration........................................................................................................................ 8
NFC Configuration....................................................................................................................... 8
Over the air configuration .......................................................................................................... 8
Application parameters............................................................................................................... 8
Sensor behavior................................................................................................................................ 9
NFC Read / Write ........................................................................................................................ 9
Sensor startup ...........................................................................................................................10
Sampling mode / Periodic measurement .............................................................................11
Schedule Transmission.............................................................................................................11
Opening activity (Reed switch) ..............................................................................................12
Specifications ..................................................................................................................................13
Sensor payload format .............................................................................................................13
Regulations......................................................................................................................................14
Legal Notices .............................................................................................................................14
Federal Communication Commission Interference Statement..........................................14
Non-modifications Statement .................................................................................................14
Caution ........................................................................................................................................15
Industry Canada Statement.....................................................................................................15
Declaration of conformity ........................................................................................................15

4
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Dimensions of the EMS Door sensor (mm)
Description
EMS Door is a subtle indoor sensor LoRaWAN® wireless network. It is equipped
with a reed switch and an accelerometer and is designed to function as an
opening activity sensor. It will detect when an object has been opened or moved.
The small size is ideal for mounting on door frames, windowpanes, cabinets and
much more. This is a two-piece device with one sensor and one smaller magnet.
EMS Door is equipped with NFC (Near Field Communication) and can easily be
configured from a smartphone.
The barcode contains DevEUI and sensor type. This label is located at the back
of your device.
Dimensions of the magnet (mm)

5
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Main features of EMS Door
•Compatible with LoRaWAN® specification 1.0.3
•Detects acceleration
•Detects opening activity (Reed Switch)
•Easy installation
•Easy configuration
•May be installed on any flat surface
•Battery-powered
•Long-range communication
•Configurable over NFC
•Configurable over the air
•Ten years of battery life*
•Supported channel plans: US902-928, EU863-870, AS923, AU915-
928, KR920-923, RU864, IN865 & HK923
•CE Approved and RoHS compliant
*Depending on settings and environmental factors

6
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Installation
1. Remove the back panel of the sensor with a small screwdriver.
2. Install the battery. The EMS requires one AA battery. The battery type is
3.6V Lithium Battery (ER14505).
Caution: Using a battery other than the one provided may result in loss of performance and
battery life, and also damage to the device. Dispose of properly, observing environmental
protection rules.
3. Mount the back panel on the surface using the adhesive tape.
4. Attach the cover to the back panel.

7
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Door activity sensor
Make sure that the magnet part is mounted on the “door”(the part that is going to
open) and the sensor part is mounted on the frame. For double doors, put one part on
each door (see image).
The reed switch is on the end of the sensor without the stripe. The magnet needs to
face this side of the sensor (see image).
The distance between magnet and sensor should, if possible, not exceed 10mm. Make
sure that the magnet and reed switch are mounted next to each other. Detection range
will be affected by the materials of the door and frame, different materials result in
different ranges.

8
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Sensor configuration
All sensor settings can be configured via a smartphone application with NFC
(Near Field Communication) or over the air via the network server and downlink
data to the sensor. The sampling rate, spreading factor, encryption keys, port,
and modes can be changed. All sensor settings can be locked from the server or
NFC to make end-users unable to read or change settings on the sensor.
NFC Configuration
1. Download ELSYS “Sensor Settings”application from Google Play or App
Store (from iOS 13) and install it on a smartphone or tablet. The device
must support NFC.
2. Enable NFC on the device and start the application.
3. Place your device on top of the EMS sensor to connect with the NFC
antenna.
You may need to remove the top cover and battery to get connection.
4. Remove the device. Current settings will be displayed in the application.
5. Use the application to change any settings if needed.
6. Quickly tap the device on top of the EMS to give the new settings to the
sensor. Make sure that the application confirms your new settings.
7. Wait for the sensor to reboot (5 sec), indicated by the LED flashing. Sensor
settings have been updated.
See the section “Help”in the application for more information.
Over the air configuration
All settings may be configured over the air via your LoRaWAN® infrastructure.
Please visit the support section on our webpage for more information regarding
downlink protocol.
Application parameters
All parameters for the “Sensor settings” application can be found in our settings
document. Please visit the support section on our webpage for more information.

9
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Sensor behavior
NFC Read / Write
1. When reading or writing NFC
configuration data to the sensor, it starts
a timer and delays its action 5 seconds.
2. After the delay, the sensor determines if
the NFC data has changed or not. If the
data has changed, the sensor reboots
and starts from power-up.
3. Write your settings in the application
and then locate the NFC antenna of the
phone and sensor. Keep the two
devices close and don’t move them to
get the best connectivity as possible
when writing or reading data to the
sensor. Bad connection can be caused
by long distance, wrong location, or
rapid movement.
4. When you have written data to the sensor, let the sensor reboot and restart
before trying to write again.
You should always validate your settings by reading the NFC data after the
sensor has restarted.

10
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Sensor startup
1. When the sensor starts up, it loads
configuration from the internal memory and
merges it with user configuration.
2. When the configuration is done, the sensor
writes the new settings to the NFC chip. The
sensor always writes new configurations to the
NFC chip when something changes in the
sensor or if NFC data is corrupted by an NFC
writer or phone. The sensor always writes the
new configuration to NFC chip at startup.
3. When the configuration is done, the sensor
tries to join the network if OTAA (Over the Air
Activation) is enabled.
4. The sensor LED flashes orange when it tries to
join a network. It will try to join every 10
seconds initially. This interval will increase to
save battery, at most up to one time per hour.
5. After successful connection to a network, the
sensor sends a settings packet and enters
sampling mode.

11
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Sampling mode / Periodic
measurement
The sensor makes periodic
measurements according to the user
configurations.
Schedule Transmission
The sensor transmits the data
according to the user
configurations.

12
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Opening activity (Reed switch)
When the reed switch changes state from
closed to open, the activity is added to a
pulse counter that keeps track of the
number of opening events. The number
of the pulse counter and the current
state is added to the data packet.
If the state is changed from open to
closed, the pulse counter remains
unchanged and only the state and
current number of counts is added to the
data packet.
After values has been added to the
packet, the EMS schedules a
transmission.

13
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Specifications
Sensor payload format
The device uses the standard ELSYS payload format. Please see the specified
document on our webpage.
Power supply:
3.6V DC
Battery type:
AA 14505 (Li-SOCI2)
EU directives compliance:
RoHS 2011/65/EU
WEEE 2012/19/EU
Radio protocol:
LoRaWAN®
Radio frequency band:
US902-928, EU863-870, AS923,
AU915-928, KR920-923, RU864, IN865
& HK923
Range:
8 km*
Operating conditions
0 to 40 °C
0 to 85 % RH (non-condensing)
Accelerometer detection level
Configurable via NFC and downlink conf.
Dimensions
21.2 x 74.9 x 21.8 mm
Battery life
Up to 10 years**
*Measured with settings: SF10, 868 Mhz. The range can be greater or less, depending on terrain and building
structure.
**Depending on settings and environmental factors.

14
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Regulations
Legal Notices
All information, including, but not limited to, information regarding the features,
functionality, and/or other product specification, are subject to change without
notice. ELSYS reserves all rights to revise or update its products, software, or
documentation without any obligation to notify any individual or entity. ELSYS
and ELSYS logo are trademarks of Elektroniksystem i UmeåAB. All other brands
and product names referred to herein are trademarks of their respective holders.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, according to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Non-modifications Statement
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.

15
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.
This device and its antenna(s) must not be co-located or operating in
conjunction with any other antenna or transmitter except in accordance with FCC
multi-transmitter product procedures.
Industry Canada Statement
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Declaration of conformity
Hereby, Elektroniksystem i UmeåAB declares that ERS complies with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
Table of contents
Other Elsys Accessories manuals

Elsys
Elsys EMS Series User manual

Elsys
Elsys ELT-2 HP User manual

Elsys
Elsys ERS CO2 User manual

Elsys
Elsys EMS Desk User manual

Elsys
Elsys ECO Series User manual

Elsys
Elsys ERS Eye User manual

Elsys
Elsys ELT-2 User manual

Elsys
Elsys ERS User manual

Elsys
Elsys ERS User manual

Elsys
Elsys ERS2 Series ERS2 Lite User manual