Elumen8 Alu Quad Par 64 User manual

Order code: ELUM114
Alu HEX Par 64
(12 x 12W 6in1 colour LEDs RGBWAUV)
User Manual

www.prolight.co.uk Alu HEX Par 64 User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablevoltageisbetween
100~240V,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• WARRANTY:Oneyearfromdateofpurchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.prolight.co.uk Alu HEX Par 64 User Manual
3
Product overview & technical specications
Housing12x12Whex-colourLEDs,theAluHEXPar64
givessmoothcolourmixingfromrichsaturatedhuesto
subtlepastelshades.Theseunitshaveruggedhousingand
featurea25°beamangle.The4pushbuttonLEDmenu
allowsforeasyaccesstothefunctionsincludingDMX,
master/slave,soundactiveandstandalone.
•2yearwarranty
•12x12W6in1colourLEDs(RGBWAUV)
•Beamangle:25°
•3.6kHzrefreshrate
•DMXchannels:1/3/4/5/6/7/8or9selectable
•Staticcolour,colourchange,colourfade,auto,
soundactiveandmaster/slavemodes
•0-100%dimmingandvariablestrobe
•4pushbuttonmenuwithLEDdisplay
•3-pinXLRin/outsockets
•PowerCONin/outsockets
•Fancooled
•OptionalBarnDoors(ELUM041C)
Alu HEX Par 64
Specications Alu HEX Par 64
Powerconsumption 150W
Powersupply 100~240V,50/60Hz
Dimensions 300x280x240mm
Weight 5.3kg
Ordercode ELUM114
0m 1m 2m 3m 4m 5m
25° - Lux 22250 5600 2500
25°
1360 930
300mm
280mm

www.prolight.co.uk Alu HEX Par 64 User Manual
4
DMX channel mode:
OperatinginDMXcontrolmodegivestheuserthegreatestexibilitywhenitcomestocustomising
orcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthextureandeach
xtureindependently.
ToaccesstheDMXchannelmode,pressthe“MODE”buttonontherearoftheunittoshow“CH:01”
ontheLEDdisplay,thenusethe“UP”and“DOWN”buttonstosetthedesiredDMXaddressofeither
1,3,4,5,6,7or9DMXchannelmodes.
Tosettheunitsaddress,pressthe“MODE”buttonontherearoftheunittoshow“ADDR:001”onthe
LEDdisplay,thenusethe“UP”and“DOWN”buttonstosetthedesiredaddressfrom“001” - “512”.
Pressthe“ENTER”buttontoconrmanysettings.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Technical specications
Operating instructions
01-Bracket
02-Brackettighteningknobs
03-Earthpoint
04-Safetyeye
05-LEDdisplay
06-Functionbuttons
07-DMXinputsocket
08-DMXoutputsocket
09-PowerCONinsocket
10-PowerCONoutsocket
11-Fuse2A240V
Inthebox:1 x xture,
1 x 13A powerCON
mains cable &
1 x user manual
www.prolight.co.uk
MODE ENTER UP DOWN
FUSE
2A/250V
SAFETY
EYE
DMX
IN
DMX
OUT
POWER IN POWER OUT
PUSH
ALU HEX
PAR 64
06 040611
03 09 07 08 10
0102

www.prolight.co.uk Alu HEX Par 64 User Manual
5
Channel Value Function
1000-255 Masterdimmer(0-100%)
2
000-255colourmacro
000-016 Red
017-033 Green
034-050 Blue
051-067 White
068-084 Amber
085-101 UV
102-118 Yellow(R-255,G-200,A-255)
119-135 Cyan(G-255,B-255)
136-152 Lavender(R-170,B-210)
153-169 Brightgreen(G-255,A-180)
170-186 Magenta(R-255,B-90,UV-255)
187-203 Turquoise(G-255,B-180,UV-255)
204-220 Orange(R-200,A-200)
221-237 Coolwhite(R-70,G-190,B-255,A-200)
238-255 Warmwhite(R-230,G-255,B-255,A-255,W-255)
2 channel mode:
Channel Value Function
1000-255 Masterdimmer(0-100%)
2000-255 Flash(speed0-100%,1Hz-20Hz)
3000-004 Blackout
005-010 Red
011-015 Green
016-020 Blue
021-025 White
026-030 Amber
031-035 UV
036-040 Yellow(R-255,G-200,A-255)
041-045 Cyan(G-255,B-255)
046-050 Lavender(R-170,B-210)
051-055 Brightgreen(G-255,A-180)
056-060 Magenta(R-255,B-90,UV-255)
061-065 Turquoise(G-255,B-180,UV-255)
066-070 Orange(R-200,A-200)
071-075 Coolwhite(R-70,G-190,B-255,A-200)
076-080 Warmwhite(R-230,G-255,B-255,A-255,W-255)
081-150 Colourjumpingspeed.Slowest(081)changesevery8secs,Fastest(150)changesevery0.3secs
151-220 Colourfadingspeed.Slowest(151)changesevery8secs,Fastest(220)changesevery0.3secs
221-255 Soundcontrol(micsensitivity)
3 channel mode:

www.prolight.co.uk Alu HEX Par 64 User Manual
6
Channel Value Function
1000-255 Red(0-100%)
2000-255 Green(0-100%)
3000-255 Blue(0-100%)
3 channel mode:
Channel Value Function
1000-255 Red(0-100%)
2000-255 Green(0-100%)
3000-255 Blue(0-100%)
4000-255 White(0-100%)
4 channel mode:
Channel Value Function
1000-255 Red(0-100%)
2000-255 Green(0-100%)
3000-255 Blue(0-100%)
4000-255 Amber(0-100%)
4 channel mode:
Channel Value Function
1000-255 Red(0-100%)
2000-255 Green(0-100%)
3000-255 Blue(0-100%)
4000-255 White(0-100%)
5 000-255 Amber(0-100%)
5 channel mode:
Channel Value Function
1000-255 Red(0-100%)
2000-255 Green(0-100%)
3000-255 Blue(0-100%)
4000-255 White(0-100%)
5 000-255 Amber(0-100%)
6 000-255 UV(0-100%)
6 channel mode:
Channel Value Function
1000-255 Masterdimmer(0-100%)
2000-255 Flash(speed0-100%,1Hz-20Hz)
3000-255 Red(0-100%)
4000-255 Green(0-100%)
5 000-255 Blue(0-100%)
6 000-255 White(0-100%)
7 000-255 Amber(0-100%)
8 000-255 UV(0-100%)
9 000-004 Blackout
005-010 Red
011-015 Green
016-020 Blue
021-025 White
026-030 Amber
031-035 UV
036-040 Yellow(R-255,G-200,A-255)
041-045 Cyan(G-255,B-255)
046-050 Lavender(R-170,B-210)
051-055 Brightgreen(G-255,A-180)
056-060 Magenta(R-255,B-90,UV-255)
061-065 Turquoise(G-255,B-180,UV-255)
066-070 Orange(R-200,A-200)
071-075 Coolwhite(R-70,G-190,B-255,A-200)
076-080 Warmwhite(R-230,G-255,B-255,A-255,W-255)
081-150 Colourjumpingspeed
Slowest(081)changesevery8secs
Fastest(150)changesevery0.3secs
151-220 Colourfadingspeed
Slowest(151)changesevery8secs
Fastest(220)changesevery0.3secs
221-255 Soundcontrol(micsensitivity)
9 channel mode:

www.prolight.co.uk Alu HEX Par 64 User Manual
7
Master/slave mode
Tosetthemasterunit,pressthe“MODE”buttonontherearofthemasterunitthenselectyour
desiredprogram.Tosetinslavemode,pressthe“MODE”buttonontherearoftheunitandsetthe
addresstoshow“SLAVE MODE”ontheLEDdisplay.Theunitwillnowruninsequencewiththemaster
unit.
Sound active mode:
Toaccessthesoundactivemode,pressthe“MODE”buttonontherearoftheunittoshow“SOUND”
ontheLEDdisplay.Theunitwillnowbeinsoundactivemode.Press“ENTER”thedisplaywillash,
nowusethe“UP”and“DOWN”buttonstosetthesoundsensitivitylevelfrom“SENS:00” - “SENS:31”
(00 = low, 31 = high).
Pressthe“ENTER”buttontoconrmanysettings.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Static colour mix mode:
Toaccessthestaticcolourmode,pressthe“MODE”buttontoshow“1.STATIC”ontherearoftheunit.
Youcanthenusetheenterbuttontoselectandsetthedesiredcoloursandbrightnessfor
R,G,B,W,AandUVfrom“00” - “99”.Youcanthensetthestrobespeedfrom“F00” - “F99”.
Pressthe“ENTER”buttontoconrmanysettings.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Built-in programs mode
Toaccessthebuilt-inprogramsmode,pressthe“MODE”buttonontherearoftheunittoshowoneof
thefollowingonthedisplay:
“2.CHANGE”willshowontheLEDdisplayforthe30colourschangemode.
“2.CHANG6”willshowontheLEDdisplayforthe6colourschangemode.
“04.DREAM”willshowontheLEDdisplayforthecolourfademode.
Ontheabove3optionsyoucanthensetthedesiredcolourchangespeedfrom“SP01” - “SP99”andthe
strobespeedfrom“F00” - “F99”.
Pressthe“ENTER”buttontoconrmanysettings.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.

www.prolight.co.uk Alu HEX Par 64 User Manual
8
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk Alu HEX Par 64 User Manual
9
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk Alu HEX Par 64 User Manual
10
Optional accessories
Pleasecontactyourlocalretailertopurchasetheseaccessories.
Optional eLumen8 Alu Tri Barn Door
Order code: ELUM041C
Optional LEDJ Alu Par 64 Series
Floor Bracket
Order Code - LEDJ119
Optional Cases
Order codes: Twin - CASE17
Twin - CASE16
Tokeepup-to-dateonthelatestaccessoriesandproduct
rangeadditionspleasevisitwww.prolight.co.uk

www.prolight.co.uk Alu HEX Par 64 User Manual
11
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.

www.prolight.co.uk Alu HEX Par 64 User Manual 12
Other manuals for Alu Quad Par 64
1
Table of contents
Other Elumen8 Floodlight manuals

Elumen8
Elumen8 ELUM062 User manual

Elumen8
Elumen8 ELUM053 User manual

Elumen8
Elumen8 Endura WW100 User manual

Elumen8
Elumen8 ZF LED Zoom Fresnel ELUM090 User manual

Elumen8
Elumen8 ELUM054A Plasma 3K RGB User manual

Elumen8
Elumen8 ELUM042 User manual

Elumen8
Elumen8 ELUM121 User manual

Elumen8
Elumen8 Tri Pixel Panel 25 ELUM085 User manual

Elumen8
Elumen8 Alu Quad Par 64 User manual

Elumen8
Elumen8 Stage Par 220 User manual