Elumen8 ELUM054A Plasma 3K RGB User manual

ELUM054A
User Manual
Please read the user manual before use

!!!
!
1A!
Table of Contents
1,Safety Information…………………………………………………. 2
2,Rear Panel…………………………………………………………. 4
3,Preparation for Use ………………………………………………...4
4,Main Functions ..………………………………………………….. 5
5,Remote Control…………………………………………………….8
6,Technical Specification…………………………………………….15

!!!
!
2A!
1. Safety Information
Warning: This product is for professional use only! It is not for
household use.
The Plasma 3K RGB presents risks of lethal or severe injury due to fire
and heat, electric shock, ultraviolet radiation, and falls. Flashing light is
also known to trigger epileptic seizures in persons who are
photosensitive. Read this manual before powering or installing the fixture,
follow the safety precautions listed below and observe all warnings in this
manual and printed on the fixture.
Noted: high voltage on the LED board!
High power strobe, so please avoid extended periods of
continuous flashing
To guard against electric shock
!Do not remove the rear cover: there are no user-serviceable parts inside.
!Always ground (earth) the fixture.
!Use only a source of AC power that complies with local building and electrical
codes and has both overload and ground-fault protection.
!Do not expose the fixture to rain or moisture.
To guard against UV radiation, burns, and fire
!Never operate the fixture with the front glass open, missing or damaged.
!Do not stare directly into the light. Never look at an exposed LED while it is lit.
!Never attempt to bypass the fuse. Always replace defective fuses with ones of the
specified type and rating.
!Verify that the power feed cable is rated for the current draw of all connected
fixtures.
!Keep all combustible materials (for example fabric, wood, paper) at least 0.5 meters
away from the fixture.
!Keep flammable materials well away from the fixture.
!Minimum distance to illuminated surface is 10 meters.
!Provide a minimum clearance of 30cm around fixture air vents.
!Never place filters or other materials over the front glass cover.

!!!
!
3A!
!The exterior of the fixture can reach high temperatures. Allow the fixture to cool for
at least 15 minutes before handling.
!Do not modify the fixture or install anything other than genuine parts.
!Do not operate if the ambient air temperature (Ta) exceeds 40° C (104° F).
To guard against falls
!When suspending the fixture above ground level, verify that the structure can hold
at least 10 times the weight of all installed fixtures.
!Verify that all external covers and rigging hardware are securely fastened and use
an approved means of secondary attachment such as a safety cable.
!Block access below the work area whenever installing or removing the fixture.
To guard against epileptic seizure
!Do not operate the fixture near stairways.
!Provide advance notice that strobe lighting is in use.
!Avoid extended periods of continuous flashing, particularly at frequencies of 10 to
20 flashes per second.

!!!
!
4A!
2. Rear Panel
1, Circuit!Breaker
2, Main Power
3. LED display
4, Menu /UP/DOWN/ Enter button
5, DMX signal/ Flash indicator
6, DMX input/output
3. Preparation for Use
INSTALLATION
The Plasma 3K RGB may be installed in any orientation. The mounting bracket provides
five 12 mm holes for direct fastening or attachment of rigging clamps.

!!!
!
5A!
4. MAIN FUNCTION
Press MENU button to enter the function, then use the UP/DOWN or MENU
buttons to select the function you want. Press the ENTER button to confirm
your selection. Wait for 30 seconds to return to the main menu or hold the
MENU button for 1 second.
The main menu as follows:
DMX 512 address setting
Select ADDR option and the display will blink, press the ENTER button to
confirm your selection. You can check the current DMX address on the
display. The DMX address can be changed by pressing the UP/DOWN
buttons and then press the ENTER button to confirm your selection. Wait for
30 seconds to return to the main menu or hold the MENU button for 1
second.

!!!
!
6A!
Channel mode setting
Select the CHND option and press the ENTER button to confirm your
selection. Change the channel mode from (1/2/3/4/6/7) channels by pressing
the UP/DOWN buttons. Press the ENTER button to confirm your selection.
Wait for 30 seconds to return to the main menu or hold the MENU button for
1 second.
LED display setting
Select the LED option and press the ENTER button to confirm your selection.
You can view the current ON/OFF status of the LED display now. You can
change its status by pressing the UP/DOWN buttons and then press the
ENTER button to confirm your selection. If you choose OFF, the LED display
will blackout after I minute. Wait for 30 seconds to return to the main menu or
hold the MENU button for 1 second.
LED display direction setting
Select the DISP option and press the ENTER button to confirm your
selection. Select the DISP / DSIP by pressing the UP/DOWN button. Press
the ENTER button to confirm your selection. Wait for 30 seconds to return to
the main menu or hold the MENU button for 1 second.
White Balance
Select the BALA option and press the ENTER button to confirm your
selection. Select the RED,GREEN,BLUE by pressing the UP/DOWN buttons.
Press the ENTER button to confirm your selection then adjust the balance
address by using the UP/DOWN buttons. Press the ENTER button to confirm.
Wait for 30 seconds to return to the main menu or hold the MENU button for
1 second.

!!!
!
7A!
Test setting
Select the TEST option and press the ENTER button to confirm your
selection. The flash indicator will light up and the unit will run an automatic
test . Once the self-test has finished it will return to the test menu. Wait for
30 seconds to return to the main menu or hold the MENU button for 1
second.
Temperature
Select the TEMP option and press the ENTER buttons and the display will
show the temperature of unit. Wait for 30 seconds to return to the main menu
or hold the MENU button for 1 second.
Defaults
Select the DEF option and press the ENTER buttons. Use the UP/DOWN
buttons if you would like reset defaults,or not. Press the ENTER
button to confirm your selection. Wait for 30 seconds to return to the main
menu or hold the MENU button for 1 second.
Fixture Hours
Select the FHRS and press the ENTER button to confirm. The display will
now show the number of working hours of the unit. To go back to the
previous functions without any changes press the MENU button.
Check the version number
Select the UER and press the ENTER button to confirm. You can now view
the current version number e.g. (b 10/v 10) and check it by using the
UP/DOWN buttons. Wait for 30 seconds to return to the main menu or hold
the MENU button for 1 second.

!!!
!
8A!
5. Remote Control
1"Channel"Mode"
Channel"
Value"
Function"
1"
0-5!
Blackout!
6-250!
Flash!rate,!slow!to!fast!
251-255!
Continuous!”Blinder”effect!
2"Channel"Mode"
Channel"
Value"
Function"
1!
0-5!
Blackout!
6-255!
Flash!rate,!slow!to!fast!
2!
Flash!intensity!
!!!!0-5!
Blackout!
6-255!
Minimum!to!maximum!
3"Channel"Mode"
Channel"
Value"
Function"
1!!Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
2!!Flash!duration!
0-255!
0-650!ms@50!Hz!AC,!or!0-530!ms@60!Hz!AC!
3!!!Flash!rate!
0-5!
No!flash!(single!flash!with!ch.!1)!
6-255!
0.5-25!Hz@50!Hz!AC,!or!0.6-30!Hz!@60!Hz!AC!

!!!
!
9A!
"
4"Channel"Mode"
Channel"
Value"
Function"
1!!Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
2!!Flash!duration!
0-255!
0-650!ms@50!Hz!AC,!or!0-530!ms@60!Hz!AC!
3!!Flash!rate!
0-5!
No!flash! ! (single!flash!with!ch.!1)!
6-255!
0.5-25!Hz@50!Hz!AC,!or!0.6-30!Hz!@60!Hz!AC!
4!
Special!effects!
0-5!
No!effect!
6-50!
Ramp!up!
51-100!
Ramp!down!
101-150!
Ramp!up-down!
151-200!
Lightning!
201-255!
Random!
"
6"Channel"Mode"
Channel"
Value"
Function"
1(R)Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
2!(G)Flash!intensity!
0-5!
Blackout!

!!!
!
10A!
6-255!
Minimum!to!maximum!
3!(B)Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
4!
(RGB)Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
5!!Flash!duration!
0-255!
0-650!ms@50!Hz!AC,!or!0-530!ms@60!Hz!AC!
6!!Flash!rate!
0-5!
No!flash!(single!flash!with!ch.!1)!
6-255!
0.5-25!Hz@50!Hz!AC,!or!0.6-30!Hz!@60!Hz!AC!
7"Channel"Mode"
"
Channel"
Value"
Function"
1!(R)Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
2!(G)Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
3!(B)Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
4!
(RGB)Flash!intensity!
0-5!
Blackout!
6-255!
Minimum!to!maximum!
5!!Flash!duration!
0-255!
0-650!ms@50!Hz!AC,!or!0-530!ms@60!Hz!AC!

!!!
!
11A!
6!Flash!rate!
0-5!
No!flash! ! (single!flash!with!ch.!1)!
6-255!
0.5-25!Hz@50!Hz!AC,!or!0.6-30!Hz!@60!Hz!AC!
7!
Special!effects!
0-5!
No!effect!
6-50!
Ramp!up!
51-100!
Ramp!down!
101-150!
Ramp!up-down!
151-200!
Lightning!
201-255!
Random!
"
"
DMX CONTROL SUMMARY
Built-in effects
Six programmed effects are available on channel 4 in the 4-channel DMX mode,
and channel 7 in the 7-channel DMX mode, The effects may be altered using
the intensity, duration, and rate controls.
!Ramp up: Light gradually increases in intensity, and then blacks out.
!Ramp down: Light flashes to full intensity, and then gradually fades.
!Ramp up-down: Light gradually increases and decreases.
!Lightning: The flashes simulate lightning. Duration is not adjustable.
!Random flash: Light flashes randomly with variable rate and intensity. Multiple
units flash independently of each other.

!!!
!
12A!
Single Flash
To trigger single flashes, start with the intensity and flash rate at 0 and then set
the intensity on channel 1. When the value of channel 1 is changed, the light
will flash once with the programmed intensity, duration, and effect.
6. Technical Specifications
Approved AC power . . . . . . . . . .. . . . . . . . . . . . . . . . . . .100 - 240 V nominal, 50/60 Hz
Total Power consumption. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200W
AC mains power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . …………….. . . . . . 1.5 m2
LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ……. . . . . …… 3w/297pcs LED
Dimension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486×154×295mm
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. .8.0kg
Ambient air temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .40° C (104° F)
Short-circuit protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . 15 amp
Safety Installation Distance
Minimum distance to combustible materials. . . . . . . . . . . . . . . . . . . . . . . . ……0.5 m
Minimum distance to illuminated surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . …10m

!!!
!
13A!
Innovation, Quality, Performance
Table of contents
Other Elumen8 Floodlight manuals

Elumen8
Elumen8 ELUM121 User manual

Elumen8
Elumen8 ELUM062 User manual

Elumen8
Elumen8 Beam 1RE User manual

Elumen8
Elumen8 ZF LED Zoom Fresnel ELUM090 User manual

Elumen8
Elumen8 ELUM042 User manual

Elumen8
Elumen8 Tri Pixel Panel 25 ELUM085 User manual

Elumen8
Elumen8 Alu Quad Par 64 User manual

Elumen8
Elumen8 Alu Quad Par 64 User manual

Elumen8
Elumen8 ELUM053 User manual

Elumen8
Elumen8 Endura WW100 User manual