Elumen8 ZF LED Zoom Fresnel ELUM090 User manual

Order codes:
ELUM090 - 100W 3200K WW Version
ELUM091 - 100W 6000K CW Version
ELUM092 - 150W 3200K WW Version
ELUM093 - 150W 6000K CW Version
ZF LED Zoom Fresnel
User Manual

www.prolight.co.uk ZF LED Zoom Fresnel User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thislightingxtureisforprofessionaluseonly-itis
notdesignedfororsuitableforhouseholduse.The
productmustbeinstalledbyaqualiedtechnicianin
accordancewithlocalterritoryregulations.Thesafetyof
theinstallationistheresponsibilityoftheinstaller.The
xturepresentsrisksofsevereinjuryordeathduetore
hazards,electricshockandfalls.
• Warning!RiskGroup2LEDproductaccordingto
EN62471.Donotviewthelightoutputwithoptical
instrumentsoranydevicethatmayconcentratethebeam.
• WARRANTY:Twoyearsfromdateofpurchase.

www.prolight.co.uk ZF LED Zoom Fresnel User Manual
3
Product overview & technical specications
TheZFLEDZoomFresnelisloadedwitha100W(150W)cool(warm)whiteLED,producinganoutputsimilartoa
650W(1000W)lamp.Controloftheunitisfacilitatedviaa4buttonmenuandLCDdisplay,whilstthebeamangle
canbemanuallyadjustedbetween12°and60°.Eightdimmercurvesareincludedformaximumexibility.
Thewholextureisenclosedinarobustchassis,andissuppliedwithlterframeandbarndoor.
•1x100WwarmwhiteCOBLED(3200K)-ELUM090
•1x100WcoolwhiteCOBLED(6000K)-ELUM091
•1x150WwarmwhiteCOBLED(3200K)-ELUM092
•1x150WcoolwhiteCOBLED(6000K)-ELUM093
•Manuallyadjustablebeamangle:12°-60°
•CRI>95
•1.6kHzrefreshrate
•DMXchannels:1or2selectable
•0-100%dimming
•4dimmingcurvesinbothLEDandhalogenproles:
Linear,squarelaw,inversesquarelawandS-curve
•4pushbuttonmenuwithLCDdisplay
•PowerCONinputputput/output
•5-PinXLRinput/output
•3-PinXLRinput/output
•Temperaturecontrolledfancooling
•Handleonrearpanel
•Filterframeandbarndoorsincluded
ZF LED Zoom Fresnel
Specications ZF LED Zoom Fresnel
Powerconsumption 120W-100WVersion
Powerconsumption 170W-150WVersion
Powersupply 100~240V,50/60Hz
Dimensions 430x270x340mm
Weight 7.3kg
Ordercode ELUM090-100WWWVersion
Ordercode ELUM091-100WCWVersion
Ordercode ELUM092-150WWWVersion
Ordercode ELUM093-150WCWVersion
0m 1m 2m 3m 4m 5m
60°
12°
20600
8630
5160
2160
2290
958
1290
539
825
345
12° - Lux
60° - Lux
100W WW
20000
7880
5000
1970
2220
875
1250
492
800
315
12° - Lux
60° - Lux
100W CW
24400
10200
6090
2560
2710
1140
1520
641
975
410
12° - Lux
60° - Lux
150W WW
33800
14800
8450
3690
3760
1640
2110
922
1350
590
12° - Lux
60° - Lux
150W CW
425mm
345mm

www.prolight.co.uk ZF LED Zoom Fresnel User Manual
4
DMX channel mode:
OperatinginDMXcontrolmodegivestheuserthegreatestexibilitywhenitcomestocustomising
orcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthextureandeach
xtureindependently.
Toaccessthe1channelDMXmode,pressthe“MENU”buttonontherearoftheunittoshow
“DMX-1CH”ontheLCDdisplay.Thextureisnowin1Channelmode.Nowusethe“UP”and“DOWN”
buttonstosetthedesiredDMXaddressforthe1Channelmode.
Toaccessthe2channelDMXmode,pressthe“MENU”buttonontherearoftheunittoshow
“DMX-2CH”ontheLCDdisplay.Thextureisnowin2Channelmode.Nowusethe“UP”and“DOWN”
buttonstosetthedesiredDMXaddressforthe2Channelmode.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Technical specications
Operating instructions
01-Earthpoint
02-LCDdisplay
03-Functionbuttons
04-3-PinDMXinput
05-3-PinDMXoutput
06-5-PinDMXinput
07-5-PinDMXoutput
08-PowerCONinput
09-PowerCONoutput
10-FuseT3.15A250V
11-Adjustablezoomknob
Inthebox:1 x xture,
1 x 13A powerCON
mains cable &
1 x user manual
DMX INPUT
DMX OUTPUT
DMX INPUT
DMX OUTPUT
FUSE: T3.15A 250V
(T6.3A 125V)
ZOOM
POWER INPUT
100-240V~50/60Hz
POWER OUTPUT
100-240V~50/60Hz
www.prolight.co.uk
ZF Zoom Fresnel
MENUINFO UP DOWN
0507 1011
06 04 0102 03
09 08

www.prolight.co.uk ZF LED Zoom Fresnel User Manual
5
Manual dimming mode:
Toaccessthesoundactivemode,pressthe“MENU”buttonontherearoftheunittoshow“WhiteSet”
ontheLCDdisplay.Theunitisnowinmanualdimmingmode.Nowusethe“UP”and“DOWN”buttonsto
setthebrightnessfrom“0” - “255”(0 = LED off, 255 = LED at full brightness).
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Dimming curves
Toaccesstheunitsdimmercurves,pressthe“MENU”buttonontherearoftheunittoshow
“Led Linear”ontheLCDdisplay.Nowusethe“UP”and“DOWN”buttonstosetthedimming
curverequired.
“Led Linear”-LEDLineardimmingcurve
“Led Square”-LEDSquaredimmingcurve
“Led InvSquar”-LEDInverseSquaredimmingcurve
“Led S-Curve”-LEDS-Curvedimmingcurve
“Halgen Linear”-HalogenLineardimmingcurve
“Halgen Square”-HalogenSquaredimmingcurve
“Halgen InvSquar”-HalogenInverseSquaredimmingcurve
“Halgen S-Curve”-HalogenS-Curvedimmingcurve
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Channel Value Function
1 000-255 Masterdimmer(0-100%)
2000-014 DimmingCurves(setviaunit)
015-044 LinearHalogendimmingcurve
045-074 SquareHalogendimmingcurve
075-104 InverseSquareHalogendimmingcurve
105-134 S-curveHalogendimmingcurve
135-164 LinearLEDdimmingcurve
165-194 SquareLEDdimmingcurve
195-224 InverseSquareLEDdimmingcurve
225-255 S-curveLEDdimmingcurve
2 channel mode:
Channel Value Function
1 000-255 Masterdimmer
(0-100%)
1 channel mode:
Pleasenote:Dimmingcurvesfor
1channelmodecanbesetvia
internalmenu.

www.prolight.co.uk ZF LED Zoom Fresnel User Manual
6
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk ZF LED Zoom Fresnel User Manual
7
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk ZF LED Zoom Fresnel User Manual
8
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
This manual suits for next models
3
Table of contents
Other Elumen8 Floodlight manuals

Elumen8
Elumen8 Alu Quad Par 64 User manual

Elumen8
Elumen8 Tri Pixel Panel 25 ELUM085 User manual

Elumen8
Elumen8 Beam 1RE User manual

Elumen8
Elumen8 ELUM053 User manual

Elumen8
Elumen8 Endura WW100 User manual

Elumen8
Elumen8 ELUM042 User manual

Elumen8
Elumen8 ELUM054A Plasma 3K RGB User manual

Elumen8
Elumen8 Alu Quad Par 64 User manual

Elumen8
Elumen8 ELUM121 User manual

Elumen8
Elumen8 Stage Par 220 User manual