Introduction
This s w i t c h is m a n a g e d redundant r i n g Ethernet s w i t c h with
8x10/100/1000Base-T(X) ports and 12x100/1000Base-X SFP ports. With
completely support of Ethernet Redundancy protocol, World’s fastest
Ethernet Redundant Ring (recovery time < 30ms) and MSTP (RSTP/STP
compatible) can protect your mission-critical applications from network
interruptions or temporary malfunctions with its fast recovery technology.
o o
And support wide operating temperature from -40 C to 75 C. The switch
can also be managed centralized and convenient by Open-Vision, Except
the Web-based interface, Telnet and console (CLI) configuration.
Therefore, the switch is one of the most reliable choice for highly-managed
and Fiber Ethernet application.
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient: If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Mechanical Loading: Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven mechanical
loading.
Reduced Air Flow: Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Circuit Overloading: Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
Safety & Warnings
Dimension
Panel Layouts
1. Power LED
2. PWR1 LED
3. PWR2 LED
4. R.M. status LED
5. Ring status LED
6. Faulty relay indicator
7. Console port
8. Link/action LED for Gigabit Ethernet ports
9. Speed LED for Gigabit Ethernet ports
10. Gigabit Ethernet ports
11. SFP port
12. Link/Act LED for SFP port
13. Reset button
Package Contents
Contents
DIN-rail Kit
HN G9812
Pictures Number
X 1
X 1
Front View
Top Panel
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
QIG
Console Cable
X 2
X 1
X 1
Wall-mount Kit
108.5
88.0
48.3
17.5
87.9
7
1
2
3
4
5
6
Rear View
1 2
PWR -1PWR -2
1A@ 24V
DC 48 V
V2- V 2+ V1- V1 +
Fau lt
1
1. Wall-mount screw holes
2. Din-rail screw holes
2
1. Terminal blocks: PWR1, PWR2
(12-48V DC), Relay
2. Ground wire.
1
Installation
the middle of the back panel.
clicks into the rail firmly.
Step 1: Slant the switch and screw the Din-rail kit onto the back of the switch, right in
Step 2: Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
DIN-rail Installation
Step 3: Insert a screw head through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the screws for added stability.
correct locations of the four screws.
Step 1: Screw the two pieces of wall-mount kits onto both ends of the rear panel of the
switch. A total of six screws are required, as shown below.
Step 2: Use the switch, with wall mount plates attached, as a guide to mark the
Wall-mounting
12
Network Connection
The IGS-9812GP has standard
Ethernet ports. According to the
link type, the switch uses CAT 3, 4,
5,5e UTP cables to connect to any
o t h e r n e t w o r k d e v i c e s ( P C s ,
ser ver s, swi tch es, rou ters , or
hubs). Please refer to the following
table for cable specifications.
Cable Types and Specifications:
154.0
96.4
10
8
9
11
10/100 Base-T(X) RJ-45 Port
Pin Number Assignments
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
13
94.0
124.0
48.0
58.0
40.0
15.514.5
7.50
Ø5.00
Ø8.00
80.50
62.0
49.67
Ø4.00
Ø4.00
PWR
PWR1
PWR2
10/10 0/100 0T
G8
G6
G4
G2
G12
G11
G10
G9
100/1 000X
G7
G5
G3
G1
G13
G14
G15
G16
G17
G18
G19
G20
100/1000X
Unit =mm (Tolerance ±0.5mm)
HN G9812
20-Port managed Gigabit
Quick Install Guide
Hatteland Technology AS | www.hattelandtechnology.com | Enterprise no: NO974533146 INB101592-1
PWR
PWR1
PWR2
10/100/1000T
G8
G6
G4
G2
G12
G11
G10
G9
100/1000X
G7
G5
G3
G1
G13
G14
G15
G16
G17
G18
G19
G20
100/1000X
Rev. 1 - 14 Feb 2020

Resetting
To reboot the switch, press the Reset button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the Reset button for 5 seconds.
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1 TD+(transmit) RD+(receive)
2 TD-(transmit) RD-(receive)
3 RD+(receive) TD+(transmit)
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit)
7 Not used Not used
8 Not used Not used
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assignment (RJ45-DB9 cable) RJ45 pin assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3 TxD PIN#3 TxD PIN#3 TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Wiring
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
PWR-1PWR-2
1A@24V
V2- V2+ V 1- V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI).
Run the ground connection from the ground screws to the grounding surface prior to connecting
devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer to the
following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password
(both are admin). After logging in, you should
see the following screen. For more information
on configurations, please refer to the user
manual. For information on operating the switch
using ORing’s Open-Vision management utility,
please go to ORing website.
Follow the steps to set up the switch:
Po w er
Redun dant I nput p ower
Power c onsu mpti on(Typ. )
Du al DC in puts . 12~4 8VDC o n 6-pi n term ina l b loc k
10 Wat ts
Ov erlo ad cur rent p rot e cti o n Pr esen t
Ph y sical C h aract e risti c
En clos ure IP -30
Di mens ion (W x D x H ) 96. 4 (W) x 10 8.5( D) x 154 (H) mm ( 3.8 x 4 . 26 x 6. 06 inc h)
RS -232 S eria l Cons ole Port
Sw itch P rope rtie s
Sw itch l aten cy: 7 u s
Sw itch b andw idth : 40G b ps
Ma x. Num ber of Ava ilab le VLA Ns: 40 95
VL AN ID Range : VID 1 to 4 094
IG MP mul tica st gro ups: 1 28 for e ach VL AN
Port rate li miti ng: Us er Def ine
Se curi ty Fe atur es
De vice B indi ng sec urit y fea t ure
En able /dis able p orts , MAC ba sed po rt sec urit y
Port ba sed ne twor k acce ss con trol ( 802. 1x)
MA C-b ased a uthe ntic atio n (802 .1x)
VL AN (80 2.1Q ) t o segr egat e and se cure n etwo rk tr affi c
SN MPv3 e ncry pted a uthe ntic atio n and ac cess s ecur ity
Ht tps / SS H enh a nce n e two r k sec urit y
Web an d CLI au then tica tion a nd aut hori zat i on
IP s ourc e guar d
So ftwa re Fe atu r es
ST P/RS TP/M STP (I EEE 80 2.1D /w/s )
Redun dant R ing (O -Rin g) wit h reco ver y time l ess th an 30m s
TOS/D iffs erv su ppor ted
Qu alit y of Ser vice ( 802. 1p) f o r rea l -ti m e tra ffi c
VL AN (80 2.1Q ) with V LAN ta ggin g
IG MP Sno opin g
Ap plic atio n-ba sed Qo S mana geme nt
DO S/DD OS aut o prev ent i on
Port co nfig ura tion , stat us, st atis tics , moni tori ng, se curi ty
DH CP Ser ver/ Cli e nt/ Rel ay
SM TP Cli ent
Mo dbus TCP
NT P serv er
Ne twor k Red unda ncy
RS -232 i n RJ45 c onne ctor w ith co nsol e cabl e. Ba u d rat e sett ing: 1 152 0 0bp s , 8, N, 1
Weig ht (g) 12 10 g
Ju mbo frame Up t o 9.6K B ytes
Weig ht (g) 71 0 g 74 0 g72 2 g 73 5 g 73 5 g 74 0 g
En v ironm e ntal
o o
-4 0 to 85 C (- 40 to 1 8 5 F)St ora g e Tem peratur e
o o
-4 0 to 75 C (- 40 to 1 6 7 F)
Op era t ing Tempe rat ure
5% t o 95% No n-co nden singOp era t ing H umid ity
MT B F 670, 184h rs
1000Base-T MDI/MDI-X
Pin Number MDI port MDI-X port
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
LED Color Status Description
PWR Green On DC power on
PWR1 Green On DC power module 1 activated
PWR2 Green On DC power module 2 activated
R.M Green On Ring Master
On Ring enabled
Ring Green Blinking Ring structure is broken (i.e. part of the ring is
disconnected)
Fault Amber On Faulty relay (power failure or port disconnected)
10/100/1000Base-T(X) Gigabit Ethernet ports
On Port link up
LNK/ACT Green
Blinking Data transmitted
Green On Port link at 1000Mbps
Amber On Port link at 100Mbps
Speed
Green/Amber Off Port link at 10Mbps
SFP
On Port link up
LNK/ACT Green
Blinking Data transmitted
1000Base-T RJ-45 Port
Pin Number Assignment
1 BI_DA+
2 BI_DA-
3 BI_DB+
4 BI_DC+
5 BI_DC-
6 BI_DB-
7 BI_DD+
8 BI_DD-
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45
Specifications
In t erfac e 8x10/100/1 0 00Base-T(X ) & 1 2x100/1000 B ase-X SFP
Ph y sical P o rts
Te c hnolo g y
Et hern et Sta ndar ds
IE EE 802 .3 for 1 0Bas e-T
IE EE 802 .3u fo r 100B ase-T X and 10 0Ba s e-F X
IE EE 802 .3ab f or 100 0Bas e-T
IE EE 802 .z for 1 000B ase-X
IE EE 802 .3x fo r Flow c ontr ol
IE EE 802 .3ad f or LAC P (Lin k Aggr egat ion Co ntro l Pro t oco l )
IE EE 802 .1p fo r COS (C lass o f Serv ice)
IE EE 802 .1Q fo r VLAN Tagg ing
IE EE 802 .1w fo r RSTP ( Rap id Spa nnin g Tree P roto col)
IE EE 802 .1s fo r MSTP ( Mult iple S pann ing Tree Pr o toc o l)
IE EE 802 .1x fo r Auth enti cati on
IE EE 802 .1AB f or LLD P (Lin k Lay er Dis covery Pr otoc ol)
10 /100 /100 0Bas e-T(X ) Por ts
in R J45 Au to MDI /MDI X
MA C Tab le 8K
Pr iori ty Que ues 8
Pr oces sing Stor e-an d-Forward
8
10 0/10 00Ba se-X wit h SFP po rt 12
Rever se pol arit y pro t ect ion Pre s ent
Fa u lt cont a ct
Relay Relay out put to c arry c apac ity of 1 A at 24V DC
Wa r ranty 5 y ears