Emerson Fisher Type 289P User manual

Introduction
This installation guide provides instructions for
installation, startup and adjustment. To receive a
copy of the instruction manual, contact your local
Sales Office or view a copy at www.fisher.com.
For further information refer to: Type 289P
Instruction Manual, D102680X012.
PED Categories
This product may be used as a pressure accessory
with pressure equipment in the following Pressure
Equipment Directive categories. It may also be used
outside of the Pressure Equipment Directive using
sound engineering practice (SEP) per table below.
For information on the current PED revision see
Bulletin: D103053X012.
PRODUCT SIZE CATEGORIES FLUID TYPE
DN 25 / NPS 1 SEP 1
Specifications
Maximum Relief (Inlet) Pressure(1)(2)
1 NPT: 3.4 bar / 50 psig over relief set pressure or
7.6 bar / 110 psig whichever is lower
2 NPT: 1.0 bar / 15 psig
Relief Set Pressure Ranges
1 NPT
Type 6358B Pilot: 0.69 to 6.9 bar / 10 to 100 psig
2 NPT
Type 6365 Pilot: 35 mbar to 0.14 bar /
14 in. w.c. to 2 psig
Type 6368B Pilot: 0.14 to 0.69 bar / 2 to 10 psig
Proof Test Pressure
All Pressure Retaining Components have been
proof tested per Directive
Temperature Capabilities(1)
Nitrile (NBR): -29 to 82°C / -20 to 180°F
Fluorocarbon (FKM): -18 to 149°C / 0 to 300°F
Installation
!
WARNING
Only qualified personnel shall install
or service a relief valve. Relief
valves should be installed, operated
and maintained in accordance with
international and applicable codes and
regulations and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If using a relief valve on a hazardous
or flammable fluid service, personal
injury and property damage could
occur due to fire or explosion
of vented fluid that may have
accumulated. To prevent such injury
or damage, provide piping or tubing to
vent the fluid to a safe, well-ventilated
area or containment vessel. Also, when
venting a hazardous fluid, the piping
or tubing should be located far enough
away from any buildings or windows
so to not create a further hazard and
the vent opening should be protected
against anything that could clog it.
Personal injury, equipment damage
or leakage due to escaping fluid
or bursting of pressure-containing
parts may result if this relief valve is
overpressured or is installed where
service conditions could exceed the
limits given in the Specifications
section or where conditions exceed
any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage,
provide pressure-relieving or
pressure-limiting devices (as required
by the appropriate code, regulation
or standard) to prevent service
conditions from exceeding limits.
Additionally, physical damage to the
relief valve could result in personal
injury and property damage due to
escaping fluid. To avoid such injury
and damage, install the relief valve in a
safe location.
Clean out all pipelines before installation of the
relief valve and check to be sure the relief valve
has not been damaged or has collected foreign
material during shipping. For NPT bodies, apply pipe
compound to the external pipe threads. For flanged
bodies, use suitable line gaskets and approved
piping and bolting practices. Install the relief valve
in any position desired, unless otherwise specified,
but be sure flow through the body is in the direction
indicated by the arrow on the body.
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
2. Relief pressure plus maximum allowable build-up over setting.
Type 289P
Installation Guide
D102680X014
English – July 2017
Note
It is important that the relief valve be
installed so that the vent hole in the
spring case is unobstructed at all times.
For outdoor installations, the relief valve
should be located away from vehicular
traffic and positioned so that water, ice
and other foreign materials cannot enter
the spring case through the vent. Avoid
placing the relief valve beneath eaves or
downspouts and be sure it is above the
probable snow level.
Note
Do not adjust main valve spring.
Overpressure Protection
Maximum inlet pressures depend upon body materials
and temperatures. Refer to the nameplate for the
maximum inlet pressure of the valve. The valve should
be inspected for damage after any overpressure
condition. Fisher™ relief valves are NOT ASME
safety relief valves.
Startup
The relief valve is factory set at approximately the
midpoint of the spring range or the pressure requested,
so an initial adjustment may be required to give the
desired results. With proper installation completed
and relief valves properly adjusted, slowly open the
upstream and downstream shutoff valves (if applicable).
Adjustment
To change the set pressure, remove closing cap
or loosen the locknut and turn the adjusting screw
clockwise to increase set pressure or counterclockwise
to decrease pressure. Monitor the set pressure with a
test gauge during the adjustment. Replace closing cap
or tighten the locknut to maintain the desired setting.
Taking Out of Service (Shutdown)
!
WARNING
To avoid personal injury resulting from
sudden release of pressure, isolate the
relief valve from all pressure before
attempting disassembly.
If pressure is introduced first to
the main valve before the pilot, the
main valve may go wide-open and
subject the downstream system to full
inlet pressure.
Parts List
1 NPT Type 289P Main Valve
Key Description
1 Body
2 Spring Case
3 Diaphragm Head
4 Spring Seat (1 NPT only)
5* Diaphragm
6 Adjusting Screw
7 Spring
8 Machine Screw / Cap Screw
9* Screen
10* Seat Ring (2 NPT only)
11* Gasket / Hex Nut
13 Snap Ring
14 Closing Cap (2 NPT only)
15* Gasket
16 Nameplate (1 NPT only)
17 Lower Spring Guide
18 Pitot tube or Stem
19* Gasket / Hex Nut
20* O-ring
21 O-ring Holder (1 NPT only)
22 O-ring Washer
23 Spacer
24 Hex Nut (1 NPT only)
26 Lower Diaphragm Head (for 2 NPT only)
27 Washer
28 Pipe Plug
29 Machine Screw
30* O-ring (1 NPT only)
31 Stem Guide Assembly
36 Pitot Tube Plug
37 O-ring (1 NPT only)
38* Gasket (2 NPT only)
50 Label
Type 6358B Pilot
Key Description
1 Pilot Body
2 Spring Case
3 Body Plug
4* Valve Plug and Stem Assembly
5* Diaphragm Assembly
6 Connector Cap
7 Spring
8 Spring Seat
9 Stem Guide
10 Adjusting Screw
11 Locknut
12 Closing Cap
13* Body Plug Gasket or O-ring
14 Valve Spring
16 Vent Assembly
17 Machine Screw
19* Closing Cap Gasket
20 Restriction
36* Stem Guide Gasket
37* Stem O-ring
* Recommended spare part
Type 289P
2
Type 6365 Pilot
Key Description
1 Body Assembly
2 Spring Case
3 Body Plug
4* Plug/Stem Assembly
5* Diaphragm Assembly (includes heat-treated
416 Stainless steel diaphragm plate)
6 Connector Cap
7 Control Spring
8 Spring Seat
9 Plug/Stem Guide
10 Adjusting Screw
11 Locknut
12 Closing Cap
13* Body Plug Gasket
14* Plug/Stem Spring
16 Type Y602-12 Vent Assembly
17 Machine Screw
19* Closing Cap Gasket
20 Restriction, Plated carbon steel
No. 70 drill size or 0.71 mm / 0.028 in. diameter,
standard (indicated by H for high gain stamped
on pilot body and yellow color code)
36* Connector Cap Gasket
Figure 2. 2 NPT Type 289P Main Valve Assembly
14A8406
26A0323
Figure 1. 1 NPT Type 289P Main Valve Assembly
APPLY LUBRICANT (L) / SEALANT (S)(1)
* Recommended spare part
1. Lubricant and sealant must be selected such that they meet the temperature requirements.
14 15
27
11
31
28
29
26
23
18
20
17
19
22
10
38
13
2
8
6
7
3
5
1
9
11
24
16
19
28
21
20
22
13
17
27
31
30
18
15
37
23
7
6
2
4
8
3
1
9
5
Type 289P
3
1
13
3
17
16
2
12
11 10
8
6
14
20
4
19
7
36
5
9
Figure 4. Type 6365 Pilot Assembly
12
10
19
8
6
5
14
9
37
3
13
1
4
20
16
36
7
2
11
17
Figure 3. Type 6358B Assembly
A6920
Type 289P
Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation
[email protected]
Emerson Automation Solutions
For further information on the current
PED revision see Bulletin: D103053X012
or scan the QR code.
Fisher.com
Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574
Europe
Bologna 40013, Italy
T +39 051 419 0611
Asia Pacic
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100
D102680X014 © 2009, 2019 Emerson Process Management Regulator
Technologies, Inc. All rights reserved. 01/19.
The Emerson logo is a trademark and service mark of Emerson
Electric Co. All other marks are the property of their prospective owners.
Fisher™ is a mark owned by Fisher Controls International LLC, a
business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes
only, and while effort has been made to ensure their accuracy, they are
not to be construed as warranties or guarantees, express or implied,
regarding the products or services described herein or their use or
applicability. All sales are governed by our terms and conditions, which
are available on request. We reserve the right to modify or improve the
designs or specications of our products at any time without notice.
Emerson Process Management Regulator Technologies, Inc does not
assume responsibility for the selection, use or maintenance of any
product. Responsibility for proper selection, use and maintenance of any
Emerson Process Management Regulator Technologies, Inc. product
remains solely with the purchaser.

Other manuals for Fisher Type 289P

1

Other Emerson Measuring Instrument manuals

Emerson Rosemount 8800D Series User manual

Emerson

Emerson Rosemount 8800D Series User manual

Emerson Rosemount CT5100 User manual

Emerson

Emerson Rosemount CT5100 User manual

Emerson Rosemount Analytical X-STREAM X2 Series User manual

Emerson

Emerson Rosemount Analytical X-STREAM X2 Series User manual

Emerson Micro Motion TA Series User manual

Emerson

Emerson Micro Motion TA Series User manual

Emerson MRLDS-250 User manual

Emerson

Emerson MRLDS-250 User manual

Emerson NGA 2000 TO2 User manual

Emerson

Emerson NGA 2000 TO2 User manual

Emerson Daniel Senior Orifice Fitting Series User manual

Emerson

Emerson Daniel Senior Orifice Fitting Series User manual

Emerson Fisher 4320 User manual

Emerson

Emerson Fisher 4320 User manual

Emerson Micro Motion 7827 Operation manual

Emerson

Emerson Micro Motion 7827 Operation manual

Emerson Rosemount 485 Annubar User manual

Emerson

Emerson Rosemount 485 Annubar User manual

Emerson Rosemount SOLU COMP II User manual

Emerson

Emerson Rosemount SOLU COMP II User manual

Emerson TopWorx 4310 User manual

Emerson

Emerson TopWorx 4310 User manual

Emerson Daniel PT Series User manual

Emerson

Emerson Daniel PT Series User manual

Emerson Rosemount 3051 Series User manual

Emerson

Emerson Rosemount 3051 Series User manual

Emerson Micro Motion FDM User manual

Emerson

Emerson Micro Motion FDM User manual

Emerson Daniel Series User manual

Emerson

Emerson Daniel Series User manual

Emerson Rosemount 9195 User manual

Emerson

Emerson Rosemount 9195 User manual

Emerson Rosemount FCL Series User manual

Emerson

Emerson Rosemount FCL Series User manual

Emerson Rosemount Analytical FCLi User manual

Emerson

Emerson Rosemount Analytical FCLi User manual

Emerson Rosemount Wireless Pressure Gauge User manual

Emerson

Emerson Rosemount Wireless Pressure Gauge User manual

Emerson Rosemount FCL User manual

Emerson

Emerson Rosemount FCL User manual

Emerson AMS 2140 User manual

Emerson

Emerson AMS 2140 User manual

Emerson 404B User manual

Emerson

Emerson 404B User manual

Emerson PENBERTHY H Series Manual

Emerson

Emerson PENBERTHY H Series Manual

Popular Measuring Instrument manuals by other brands

Eastron SDM220-Modbus user manual

Eastron

Eastron SDM220-Modbus user manual

Stanley STHT77498 manual

Stanley

Stanley STHT77498 manual

TFA 30.2033.20 instruction manual

TFA

TFA 30.2033.20 instruction manual

MICRO-EPSILON optoCONTROL 1202 instruction manual

MICRO-EPSILON

MICRO-EPSILON optoCONTROL 1202 instruction manual

Antylia Scientific Traceable 56000-10 quick start guide

Antylia Scientific

Antylia Scientific Traceable 56000-10 quick start guide

Vogtlin red-y compact Series operating instructions

Vogtlin

Vogtlin red-y compact Series operating instructions

OfiTE 900 instruction manual

OfiTE

OfiTE 900 instruction manual

Gossen MetraWatt DIGISIX 2 operating instructions

Gossen MetraWatt

Gossen MetraWatt DIGISIX 2 operating instructions

Bosch GRL 250 HV Original instructions

Bosch

Bosch GRL 250 HV Original instructions

Protimeter Digital Mini BLD5702 instruction manual

Protimeter

Protimeter Digital Mini BLD5702 instruction manual

TESTO 0600.9430 Instructions for use

TESTO

TESTO 0600.9430 Instructions for use

DAKOTA ULTRASONICS DX-1 manual

DAKOTA ULTRASONICS

DAKOTA ULTRASONICS DX-1 manual

Xylem Sensus Domo R Instructions for installation, use and maintenance

Xylem

Xylem Sensus Domo R Instructions for installation, use and maintenance

Omega FL-7600 Series Install manual

Omega

Omega FL-7600 Series Install manual

FLIR MR176 user manual

FLIR

FLIR MR176 user manual

Kompernass KH 3229 operating instructions

Kompernass

Kompernass KH 3229 operating instructions

Bühler technologies 222 AMEX Series Installation and operation instruction

Bühler technologies

Bühler technologies 222 AMEX Series Installation and operation instruction

Raritan PMC-1000 Quick setup guide

Raritan

Raritan PMC-1000 Quick setup guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.