To take a forehead temperature:
Infrared Forehead Thermometer
(4DET-306) Quick Start Guide
Detailed instructions are included in the packaging
If the body temperature is below 100°F
(38.7°C) you will hear one short beep and a
happy face will appear on the display.
If the body temperature is above 100°F
(38.7°C) you will hear one long beep
followed by three short beeps and a sad
face will appear on the display.
Press the power button , wait for 2 beeps.
Aim the thermometer at the center of the
forehead about 1 inch (2-3 cm) from the skin
and press the start button .
START
1
2
START
1
2
1” (2-3cm)
Temperature Taking Hints and Tips
• All body site temperatures are not the same. The
temperature taken at different sites on the body will vary
significantly. A forehead (temporal) temperature, for
example, is usually 0.5°F (0.3°C) to 1.0°F (0.6°C) lower
than an oral temperature.
• Make certain the thermometer is in FOREHEAD MODE.
• Non-contact infrared thermometers measure surface
temperature. Hold the device approximately 1 inch (2-3
cm) from the center of the forehead to capture just the
forehead temperature and not the temperature of other
surrounding objects.
• Always hold the thermometer and the forehead steady
when taking a reading. Do not move the thermometer
until you hear the final beep.
• The device is designed to be used indoors. Users and the
thermometer should be in the same ambient temperature
for at least 10 minutes before taking a reading.
• The tested individual should be away from extreme
temperatures for at least 10 minutes before taking a
measurement. Recent exposure to hot or cold
temperatures will impact your reading.
• Do not take temperatures with this thermometer near
places that are very hot, such as fireplaces and stoves.
• Remove hair, sweat, oils, cosmetics or dirt from the
forehead before taking a measurement. Wait at least 10
minutes after washing the forehead area before taking a
reading. Remove hats and wait 10 minutes before taking a
reading. Bangs may cause higher readings.
• The tested individual should not drink, eat, or be
physically active before/while taking the measurement.
PRODUCT FEATURES
Fast reading (approx.1 second)
No probe covers needed
Beeps when reading is complete
Mercury free
Stores 10 readings
Automatic shut-off
Fast reading (approx.1 second)
Beeps when reading is complete
Distributed by Cooper-Atkins
Emerson Commercial & Residential Solutions
33 Reeds Gap Road | Middlefield, CT 06455
T+800-835-5011 | F+860-347-5135
www.cooper-atkins.com | 67-1793 | 0520
Manufactured by JoyTech Healthcare Co., Ltd.
No.365, Wuzhou Road,
Yuhang Economic Development Zone,
311100, Hangzhou, China
T +86-571-81957767
Made in China
• Temporal artery temperature changes faster than a
temperature taken rectally, orally or under the arm. A
difference of 1°F (.6°C) is normal. Body temperature can
change throughout the day.
• Consistently low temperature readings may be caused by a
dirty instrument window. Use an alcohol wipe or a cotton
swab moistened with alcohol (70% isopropyl) to clean the
instrument window and housing. Gently wipe and let air dry.
DO NOT use any other cleaning liquids or immerse the
thermometer in water. Wait 10 minutes after cleaning to
take a temperature. See manual for complete cleaning
instructions.
• It is helpful to know each individual’s normal temperature
when they are well. This is the best way to accurately
diagnose a fever. To determine normal temperature, take
multiple readings when healthy. Re-measure with a
standard digital thermometer for confirmation. This
thermometer displays an oral equivalent temperature
reading. Oral readings are approximately 0.9°F (0.5 °C)
lower than a rectal digital measurement.
• When comparing temperature taken with different
thermometers at different sites, it is important to start with
the most accurate oral temperature that can be achieved.
Fast read digital thermometers use a method called “peak
hold” that is often less accurate than a digital thermometer
that needs to be held in the mouth for 60 seconds or more.
It is best to correlate other types of temperature taking to a
baseline oral temperature taken with accurate oral
thermometers, (those without the “peak hold” function).
The contents of this Quick Start Guide are provided by the manufacturer and are not to be construed as warranties or guarantees, express or implied, regarding the products or services described
herein or their use or applicability. Responsibility for proper selection, use and maintenance of product remains solely with the purchaser and end-user.
67-1793 Emerson is a trademark of Emerson Electric Co. ©2020. All rights reserved.

Other Emerson Thermometer manuals

Emerson Dixell XT11S User manual

Emerson

Emerson Dixell XT11S User manual

Emerson Cooper-Atkins 20200 User manual

Emerson

Emerson Cooper-Atkins 20200 User manual

Popular Thermometer manuals by other brands

optris CT Operator's manual

optris

optris CT Operator's manual

EUTECH INSTRUMENTS ECOSCAN TEMP JKT TEMPERATURE METER instruction manual

EUTECH INSTRUMENTS

EUTECH INSTRUMENTS ECOSCAN TEMP JKT TEMPERATURE METER instruction manual

Southwire 30010S operating instructions

Southwire

Southwire 30010S operating instructions

MARTINDALE DT73 instruction manual

MARTINDALE

MARTINDALE DT73 instruction manual

Explore Scientific WSH0002 instruction manual

Explore Scientific

Explore Scientific WSH0002 instruction manual

Traceable 4134 instructions

Traceable

Traceable 4134 instructions

CONDTROL IR-T1 user manual

CONDTROL

CONDTROL IR-T1 user manual

Westmark 1504 2280 manual

Westmark

Westmark 1504 2280 manual

BROWN 185109 Operation manual

BROWN

BROWN 185109 Operation manual

Triplett IRT227 user manual

Triplett

Triplett IRT227 user manual

Auriol H4286A Operation and safety notes

Auriol

Auriol H4286A Operation and safety notes

Temper Koban KTS-IR user manual

Temper

Temper Koban KTS-IR user manual

Velleman DVM105 user manual

Velleman

Velleman DVM105 user manual

Digimate FM35 operating instructions

Digimate

Digimate FM35 operating instructions

Walgreens IR1DA1 instruction manual

Walgreens

Walgreens IR1DA1 instruction manual

Braun ThermoScan PRO 6000 Cleaning and maintenance guide

Braun

Braun ThermoScan PRO 6000 Cleaning and maintenance guide

Wiselion WBS-T007 quick start guide

Wiselion

Wiselion WBS-T007 quick start guide

Microlife MT 16F1 quick start guide

Microlife

Microlife MT 16F1 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.