To take a forehead temperature:
Infrared Forehead Thermometer
(4DET-306) Quick Start Guide
Detailed instructions are included in the packaging
If the body temperature is below 100°F
(38.7°C) you will hear one short beep and a
happy face will appear on the display.
If the body temperature is above 100°F
(38.7°C) you will hear one long beep
followed by three short beeps and a sad
face will appear on the display.
Press the power button , wait for 2 beeps.
Aim the thermometer at the center of the
forehead about 1 inch (2-3 cm) from the skin
and press the start button .
START
1
2
START
1
2
1” (2-3cm)
Temperature Taking Hints and Tips
• All body site temperatures are not the same. The
temperature taken at different sites on the body will vary
significantly. A forehead (temporal) temperature, for
example, is usually 0.5°F (0.3°C) to 1.0°F (0.6°C) lower
than an oral temperature.
• Make certain the thermometer is in FOREHEAD MODE.
• Non-contact infrared thermometers measure surface
temperature. Hold the device approximately 1 inch (2-3
cm) from the center of the forehead to capture just the
forehead temperature and not the temperature of other
surrounding objects.
• Always hold the thermometer and the forehead steady
when taking a reading. Do not move the thermometer
until you hear the final beep.
• The device is designed to be used indoors. Users and the
thermometer should be in the same ambient temperature
for at least 10 minutes before taking a reading.
• The tested individual should be away from extreme
temperatures for at least 10 minutes before taking a
measurement. Recent exposure to hot or cold
temperatures will impact your reading.
• Do not take temperatures with this thermometer near
places that are very hot, such as fireplaces and stoves.
• Remove hair, sweat, oils, cosmetics or dirt from the
forehead before taking a measurement. Wait at least 10
minutes after washing the forehead area before taking a
reading. Remove hats and wait 10 minutes before taking a
reading. Bangs may cause higher readings.
• The tested individual should not drink, eat, or be
physically active before/while taking the measurement.
PRODUCT FEATURES
Fast reading (approx.1 second)
No probe covers needed
Beeps when reading is complete
Mercury free
Stores 10 readings
Automatic shut-off
Fast reading (approx.1 second)
Beeps when reading is complete
Distributed by Cooper-Atkins
Emerson Commercial & Residential Solutions
33 Reeds Gap Road | Middlefield, CT 06455
T+800-835-5011 | F+860-347-5135
www.cooper-atkins.com | 67-1793 | 0520
Manufactured by JoyTech Healthcare Co., Ltd.
No.365, Wuzhou Road,
Yuhang Economic Development Zone,
311100, Hangzhou, China
T +86-571-81957767
Made in China
• Temporal artery temperature changes faster than a
temperature taken rectally, orally or under the arm. A
difference of 1°F (.6°C) is normal. Body temperature can
change throughout the day.
• Consistently low temperature readings may be caused by a
dirty instrument window. Use an alcohol wipe or a cotton
swab moistened with alcohol (70% isopropyl) to clean the
instrument window and housing. Gently wipe and let air dry.
DO NOT use any other cleaning liquids or immerse the
thermometer in water. Wait 10 minutes after cleaning to
take a temperature. See manual for complete cleaning
instructions.
• It is helpful to know each individual’s normal temperature
when they are well. This is the best way to accurately
diagnose a fever. To determine normal temperature, take
multiple readings when healthy. Re-measure with a
standard digital thermometer for confirmation. This
thermometer displays an oral equivalent temperature
reading. Oral readings are approximately 0.9°F (0.5 °C)
lower than a rectal digital measurement.
• When comparing temperature taken with different
thermometers at different sites, it is important to start with
the most accurate oral temperature that can be achieved.
Fast read digital thermometers use a method called “peak
hold” that is often less accurate than a digital thermometer
that needs to be held in the mouth for 60 seconds or more.
It is best to correlate other types of temperature taking to a
baseline oral temperature taken with accurate oral
thermometers, (those without the “peak hold” function).
The contents of this Quick Start Guide are provided by the manufacturer and are not to be construed as warranties or guarantees, express or implied, regarding the products or services described
herein or their use or applicability. Responsibility for proper selection, use and maintenance of product remains solely with the purchaser and end-user.
67-1793 Emerson is a trademark of Emerson Electric Co. ©2020. All rights reserved.

Other Emerson Thermometer manuals

Emerson Cooper-Atkins 20200 User manual

Emerson

Emerson Cooper-Atkins 20200 User manual

Emerson Dixell XT11S User manual

Emerson

Emerson Dixell XT11S User manual

Popular Thermometer manuals by other brands

Extech Instruments 42511 user manual

Extech Instruments

Extech Instruments 42511 user manual

Kometec DOSTMANN ScanTemp RH 860 user manual

Kometec

Kometec DOSTMANN ScanTemp RH 860 user manual

Radiance instruments STD-RT806MAEB-RF Product user manual

Radiance instruments

Radiance instruments STD-RT806MAEB-RF Product user manual

TFA 30.3051 instruction manual

TFA

TFA 30.3051 instruction manual

Klein Tools IR1KIT instruction manual

Klein Tools

Klein Tools IR1KIT instruction manual

Hama TC-100 instruction manual

Hama

Hama TC-100 instruction manual

marsden UFR118 user manual

marsden

marsden UFR118 user manual

ThermoPro TP-03B instruction manual

ThermoPro

ThermoPro TP-03B instruction manual

LumaSense technologies E2T PULSAR 4 quick start guide

LumaSense technologies

LumaSense technologies E2T PULSAR 4 quick start guide

Refrigeration Innovation Thermo-Simple 1 version 2 manual

Refrigeration Innovation

Refrigeration Innovation Thermo-Simple 1 version 2 manual

Ideen Welt W240 instruction manual

Ideen Welt

Ideen Welt W240 instruction manual

Waeco AirConService TM-84N operating manual

Waeco

Waeco AirConService TM-84N operating manual

General IRT675 user manual

General

General IRT675 user manual

Fluke VT06 Safety information

Fluke

Fluke VT06 Safety information

Larson Electronics XLE-MD-TM-IR-R1 instruction manual

Larson Electronics

Larson Electronics XLE-MD-TM-IR-R1 instruction manual

az-instrument 8878 Operation manual

az-instrument

az-instrument 8878 Operation manual

Coitech E0139ST2 operating instructions

Coitech

Coitech E0139ST2 operating instructions

SKF TKTL 40 Instructions for use

SKF

SKF TKTL 40 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.