manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ENDA
  6. •
  7. Timer
  8. •
  9. ENDA ATM9321 User manual

ENDA ATM9321 User manual

ENDA ATM9321
ANALOG TIMER with DIGITAL DISPLAY
Control output state LED
(Light is on when control output is energized)
1. /2 ATM9321-E-09050219
Set key
Timer setting knob
Timer display
(minute)
Plastic injection presses, automatic bread making ovens, nylon bag machines,
shrink packing machines, furniture presses, industrial ovens, textile machines,
ironing presses and other time control applications.
Application Areas
Technical Specifications
Thank you for choosing ENDAATM9321 analog timer.
Read this document carefully before using this device. The guarantee will be
expired by damaging of the device if you don't attend to the directions in the user
manual. Also we don't accept any compensations for personal injury, material
damage or capital disadvantages.
* 96 x 96mm sized.
* Digital display for timer value.
* Selectable scale with 0 ... 9.99 or 0 ... 99.9 or 0 ... 999 minutes
* Selectable mode A (on-delay) and mode B
(off-delay) output functions.
* Start by start input.
* Reset by reset input.
* Easy setting procedure.
* Having CE mark according to European Norms.
ELECTRICAL CHARACTERISTICS
Supply voltage 24V AC %10, 50/60Hz or optinal230V AC +%10 -%20, 50/60Hz or 9-30V DC SMPS module.±
Power consumption Max. 6VA
2.5mm²'lik screw-terminal connections.
0 ... 9.99 or 0 ... 99.9 or 0 ... 999 minutes (selectable)
±1 digit
± ±%4 for analog scale, %0,5 for timer display (of full scale)
3 digits, 7.62mm, 7 segment red LED
Wiring
Scale
Sensitivity
Accuracy
Display
Data Retention
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
EEPROM (Min. 10 years)
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
Contact input (during min. 5ms.)
Contact input
HOUSING
Housing type Suitable for flush-panel mounting.
Dimensions W96xH96xD50mm
Weight Approx. 250g (after packing the device)
Enclosure material Self extinguishing plastics
CONTROL Mode A : Control output is energized after setting time is over
Mode B : Control output is energized during setting time. .
Output function
A/D converter 10 bits
OUTPUTS
Control output Relay : 250V AC, 2A(for resistive load), NO+NC or 12V DC 20mA logic output
Mechanical 30.000.000 operation; electrical 300.000 operation.
Life expectancy for relay
ENVIRONMENTAL CONDITIONS
Height Max. 2000m
80%, up to 31°C decreasing linearly 50% at 40°C
Ambient/storage temperature
Max. relative humidity 0 ... +50°C/-25 ... 70°C
Rated pollution degree According to EN 60529 Front panel : IP60
Rear panel : IP20
Dimensions 50mm
14mm
57mm
99mm
Flush mounting
clamp
Depth
Rubber
packing
Panel
Panel cut-out
105mm
90.5mm
Do not use the device in locations subject to corrosive and flammable gasses.
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
For removing mounting clamps: Push out the flush-mounting clamp in direction 1.
Then, pull out the clamp in direction 2.
12
INPUTS
Start input
Reset input
Setting value is
percentage of
the full scale.
50
10
0
ENDA
OUT
20
30
40
min
100 %
ATM9321
SET
90
80
70
60
50
10
0
ENDA
OUT
20
30
40
min
100 %
ATM9321
SET
90
80
70
60
1) Panel thickness should be
max. 10mm.
2) If there is no 60mm free
space at the back side of the
device, it would be difficult to
remove it from the panel.
Note :
english
Output Functions Connection Diagram
Supply Voltage Order Code
230V AC +%10 -%20
24VAC %10±
ATM9321
ATM9321-SSR
ATM9321-24
ATM9321-24-SSR
Control Output
Relay
Logic Output
Relay
Logic Output
ENDAATM9321 is intended for installation in control panels. Make sure that the device
is used only for intended purpose. The shielding must be grounded on the instrument
side. During an installation, all of the cables that are connected to the device must be
free of energy. The device must be protected against inadmissible humidity, vibrations,
severe soiling and make sure that the operation temperature is not exceeded. All input
and output lines that are not connected to the supply network must be laid out as
shielded and twisted cables. These cables should not be close to the power cables or
components. The installation and electrical connections must be carried on by a
4
5
2 3 4 5 6 7 8
ENDA INDUSTRIAL ELECTRONICS
ATM9321 ANALOG TIMER
SN: XXXXXXXXX
1 1 2 3 4 5 6 7 8
+
-
ENDA INDUSTRIAL ELECTRONICS
ATM9321-SSR ANALOG TIMER
SN: XXXXXXXXX
184-253VAC
50/60Hz 5VA
230V AC Supply
Switch
Cable Size: 1,5mm²
Fuse
F 100 mA 250V AC
Neutral
Line
SUPPLY:
NOTE :
Fuse should
be connected.
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
Power
When START input is triggered, timer starts running and control output is energized.
START
Control Output
Programming Diagram
RESET
T: Setting time (minute), Ta<T
START is triggered by rising edge and it is activated after 5ms.
NOTE:
MODE A
MODE B
If this message is seen, it means the device has
a calibration error. In this case, the device should
be sent to SiselA.Þ. or to a nearest ENDA local
representative for calibration and testing. When
this message is seen, the control output is
de-energized.
ERROR MESSAGE:
Power
When START input is triggered, timer starts running. Control output is energized after setting time is over.
START
Control Output
RESET
1) Mains supply cords shall meet the requirements of IEC 60227
or IEC 60245.
2) In accordance with the safety regulations, the power supply
switch shall bring the identification of the relevant instrument
Note :
While key is being turned left or right,
the parameters related to that menu appear.
To confirm the parameter, press key.
SET
If timer is energized by pressing set key, programming mode is entered.
NOTE :
Control output is off after setting time is over.
5ms 5ms
Ta
T
T
5ms
TT
9-30V DC SMPS ATM9321-24DC
ATM9321-24DC-SSR
Relay
Logic Output
SET
SET
SET
SET
SET
SET
SET
SET SET SET
SET
SET
SET
SET
SET
SET SET
SET Exit from programming mode
Run mode
Scale selection menu
Configuration menu for output function
Flash selection menu
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
/ D-72160 Horb a.NDettinger Str. 9 2. /2 ATM9321-E-09050219

This manual suits for next models

5

Other ENDA Timer manuals

ENDA EM4401 Series User manual

ENDA

ENDA EM4401 Series User manual

ENDA ATP4 User manual

ENDA

ENDA ATP4 User manual

ENDA PTM232 User manual

ENDA

ENDA PTM232 User manual

ENDA ETM1411 Series User manual

ENDA

ENDA ETM1411 Series User manual

ENDA ETM442 Series User manual

ENDA

ENDA ETM442 Series User manual

ENDA ETM742 Operating instructions

ENDA

ENDA ETM742 Operating instructions

ENDA ETM1411 User manual

ENDA

ENDA ETM1411 User manual

Popular Timer manuals by other brands

ELMARK VBRTV492 Operational guide

ELMARK

ELMARK VBRTV492 Operational guide

F&F PCZ-528.3 manual

F&F

F&F PCZ-528.3 manual

Power-flo PFDT owner's manual

Power-flo

Power-flo PFDT owner's manual

ANV APT2-S manual

ANV

ANV APT2-S manual

STARLANE CORSARO Installation and operation manual

STARLANE

STARLANE CORSARO Installation and operation manual

Rain Bird SST-900i Operation manual

Rain Bird

Rain Bird SST-900i Operation manual

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Anslut 006053 operating instructions

Anslut

Anslut 006053 operating instructions

Intermatic TN111 supplementary guide

Intermatic

Intermatic TN111 supplementary guide

Vista DTC-200 Installation and user instructions

Vista

Vista DTC-200 Installation and user instructions

claber Aqua-Home 4-6-8 user manual

claber

claber Aqua-Home 4-6-8 user manual

Toone ZYT22-AD quick start guide

Toone

Toone ZYT22-AD quick start guide

Tense ERD-48M instructions

Tense

Tense ERD-48M instructions

TFA 38.1029.02 instruction manual

TFA

TFA 38.1029.02 instruction manual

ALGE-Timing Timy manual

ALGE-Timing

ALGE-Timing Timy manual

UltraPro 40955 user manual

UltraPro

UltraPro 40955 user manual

F&F ASO-205 manual

F&F

F&F ASO-205 manual

Tamarack Technologies 42E724P Installation and operating instructions

Tamarack Technologies

Tamarack Technologies 42E724P Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.