ENDA EM4401 Series User manual

ENDA EM4401 DIGITAL TIMER
TECHNICAL SPECIFICATIONS
Note : Relay and S.S.OUT outputs are works synchronized. So, if OUT1 or OUT2 is relayed (on), SSR1 or SSR2 transistor operates.
1/7
Height Max. 2000m
Do not use the device in locations subject to corrosive and flammable gasses.
Max. humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
Ambient/Storage temperature
Relative Humidity
0 ... +50 / ° C -25... +70°C
Protection Class According to EN60529; Front panel: IP65 Rear panel : IP20
ENVIRONMENTAL CONDITIONS
Supply
Power Consumption Max. 5VA
2.5mm² Screw-terminal power connection, 1,5mm² Terminal plug-in signal connection.
Wiring
Date Retention
EMC
Safety Requirements
EN 61326-1: 2013 (Performance criterion B is satisfied for EN 61000-4-3)
EEPROM (Min. 10 years)
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
ELECTRICAL CHARACTERISTICS
230V AC , 50/60Hz or 24V AC ±%10, 50/60Hz or 9-30V DC / 7-24V AC ±%10 SMPS
INPUTS
Start, Gate, Reset input
Input types can be adjusted as PNP or NPN in “Programming Mode”.
Minimum pulse and void duration times can be adjusted between 5 and 100ms.
For PNP input types, active level is 5 to 30V pulse,
For NPN input types, active level is 0 to 2V pulse.
Mechanical 5.000.000, Electrical 200.000 operation.
Life expectancy for relay
SSR1, SSR2 output
OUTPUTS
Control output OUT1,OUT2
Open collector output (S.S. OUT): Max. 30V DC, 100mA
Auxiliary power supply
12V DC, max. 50mA (without regulation)
Accuracy
± % 0.01 ± 1ms
Housing Type Suitable for flush-panel mounting according to DIN 43 700.
Dimensions W48xH48xD87mm
Weight Approx. 230g (After packing)
Enclosure Materials Self extinguishing plastics
While cleaning the device, solvents (thinner, gasoline, acid etc.) or corrosive materials must not be used.
HOUSING
Mo Tu We Th Fr Sa Su
Out1
Out2
Out3
s
s
m
m
h
Mo
T
A
PRG
OUT
MODE
Tu We Th Fr Sa Su
h
Start
Reset
Gate
EM4401
ENDA
DIGITAL TIMER
0
EM4401-EN-01-180308
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18
Read this document carefully before using this device. The guarantee will be expired by device demages if you don't attend
to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital
disadvantages.
Thank you for choosing ENDA EM4401 Digital Timer.
ENDA
TM
Order Code : Em4401 - -
1 2
1 - Supply Voltage
230......230V AC
024......24V AC
SM......7-24VAC/9-30VDC
2 - ModBus
RS .........RS485 input
Blank .....N/A
(Specify at order)
48x48mm sized.
Easy to use .
9 Level time intervals. (Between 0-99.99sec. and 0-9999 hours).
Sensor type selection (PNP, NPN).
Selectable up / down counting direction.
Adjustable input signal pulse and void duration.
Memory option can be selected.
12 Different output mode.
Two N.O. contact output and two NPN 50mA SSR output with current limiting.
Display brightness can be adjusted.
P
2x4 line display.
arameter security can be adjusted.
Easy installation and service operations with terminal plug-in connectors.
Rs485 ModBus communication input. (Specify at order).
CE marked according to European Norms.
OUT1 : 250V AC, 10A (for resistive load), NO, NC - OUT2 :250V AC, 5A (for resistive load), NO

Mo Tu We Th Fr Sa Su
Out1
Out2
Out3
s
s
m
m
h
Mo
T
A
PRG
OUT
MODE
Tu We Th Fr Sa Su
h
Start
Reset
Gate
EM4401
ENDA
DIGITAL TIMER
0
TERMS
Two pieces (Green)
Three pieces (Green)
Indicates selected output mode number (Green)
Indicates setpoint name in SV indicator (Green)
7 Segment, 4 digits green LCD indicator (Character height 10mm)
Micro switch
( 5 ) SV Display
( 2 ) Output indicators
( 6 ) Input indicators
( 3 ) Output mode indicator
( 7 ) Key pad
( 4 ) setpoint information
( 1 ) PV Display
(1) Time value (in “Running Mode”)
Menu and Parameter name value (in “Programming Mode”)
(2) Indicates output status.
(6) Signal input status indicators.
(5) Setpoint or time value. (In “Running Mode”)
Parameter value (In “Programming Mode”)
(3) Output mode indicator. (In “Running Mode”)
(4) Timer setpoint selection indicator. (In “Running Mode”)
(7) Key pad.
(8) Counting direction indicator
Reset
Reset
Reset
Reset
TIME VALUE SETTINGS
s
s ss s s
s
s
s
s
s ss s s
s
s
s
m
m mm m m
m
m
m
m
m mm m m
m
m
m
h
h hh h h
h
h
h
T
T
T
T
T
TTT T T
A
A
A
A
A
AAA A A
PRG
PRG PRGPRG PRG PRG
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
h
h hh h h
h
h
h
Start
Start StartStart Start Start
Start
Start
Start
Reset
ResetReset Reset Reset
Reset
Reset
Reset
Gate
Gate
Gate
GateGate Gate Gate
Gate
Gate
Gate
2559
2559 25592559 2559 2559
2559
2559
2559
3000
3000 31003000 3100 3059
3500
4000
4500
1
1
1
2
2
111 1 1
0
0 00 0 0
0
0
0
Out2
Out2 Out2Out2 Out2 Out2
Out2
Out2
Out2
Out1
Out1 Out1Out1 Out1 Out1
Out1
Out1
Out1
SET
T
A
PRGPRG
2
T
A
PRGPRG
2
T
A
PRGPRG
1
Is any key
is pressed for 3
seconds?
YES
NO
After the T1 time is selected with key, by key is pressed and to be adjusted and selected left two digits of the T1 setpoint appears
by flashing. T1 time setpoint can be adjusted by using and keys for required value. By using key, toggles between right and
left two digits.
By using key, T1A, T2 and T2A time setpoints can be selected and can be adjusted like T1 time value.
If no key is pressed for 3 seconds, it returns to "Running Mode".
While in "Runnig Mode", by every pressing key, T1, T1A, T2 and T2A setpoints can be selected respectively.
Selected value is indicated by flashing. If no key is pressed for 3 seconds, it returns to "Running Mode".
T1A setpoint can be visible if Out Mode 9, A, and b is selected.
T2 setpoint can be visible if o.2.cn parameter is selected as t2.on , t2.oF or "Out Mode b" is selected.
T2A setpoint can be visible if o.2.cn parameter is selected as t2.on , t2.oF or "Out Mode 9", "Out Mode A" or
“Out Mode b" is selected.
When changes are made in t1.r , t1.L and t1.H parameters of T1 setpoint and if T1 setpoint is not in limits, T1 will be set
into the limits automatically.
When changes are made in t1A.r , t1A.L and t1A.H parameters of T1A setpoint and if T1A setpoint is not in limits, T1A will
be set into the limits automatically.
When changes are made in t2.r , t2.L and t2.H parameters of T2 setpoint and if T2 setpoint is not in limits, T2 will be set
into the limits automatically.
When changes are made in t2A.r , t2A.L and t2A.H parameters of T2A setpoint and if T2A setpoint is not in limits, T2A will
be set into the limits automatically.
T2 and T2A set values are can be visible if o.2.cn parameter is selected as t2.on , t2.oF or
"Out Mode b" is selected.
RUNNING MODE
SET
0
0
TIME VALUE SETTING POSITION
7 Segment, 4 digits green LCD indicator (Character height 7mm)
2/7
EM4401-EN-01-180308
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18 ENDA
TM

Between
0 min., 0.01sec
and
99 min., 59 sec.
Mo
Mo
Mo
Mo
Tu
Tu
Tu
Tu
We
We
We
We
Th
Th
Th
Th
Fr
Fr
Fr
Fr
Sa
Sa
Sa
Sa
Su
Su
Su
Su
Mo
Mo
Mo
Mo
Mo
PRG PRG PRG
PRG
PRG
PRG
PRG
PRG
PRG
Tu
Tu
Tu
Tu
Tu
We
We
We
We
We
Th
Th
Th
Th
Th
Fr
Fr
Fr
Fr
Fr
Sa
Sa
Sa
Sa
Sa
Su
Su
Su
Su
Su
t1.cn t2.cn o.cnF
o.1.cn
o.2.cn
o.1.o.t
o.2.o.t
S.mEm
d.cnF
t1o. n
oFF
Hold
Hold
no
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo Mo
Mo
Mo
Mo Mo
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu Tu
Tu
Tu
Tu Tu
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We We
We
We
We We
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th Th
Th
Th
Th Th
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr Fr
Fr
Fr
Fr Fr
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa Sa
Sa
Sa
Sa
Sa
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su Su
Su
Su
Su Su
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3
Out3 Out3
Out3
Out3
Out3
Out3
Out3
Out3
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
sss
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m m mm
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
Mo
T
T
T
T
T
T
T
T
T
T
T
T
T
TT
T
T
T
T
T
T
T
T
T
A A A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AA
A
A
A
A
A
A
A
A
A
PRG PRG PRG PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
PRG
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
OUT
MODE
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
Tu
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
We
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Th
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Fr
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Sa
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
Su
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
h
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset
Reset Reset
Reset
Reset
Reset
Reset
Reset
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
Gate
t1 ..r
i.flt t1.c..s
t.dir
d.mod
s.Cod
i.typ
d.lth
t2.c.s
o.cn.s
d.cn.s
D.aDr
P.r.Co
bauD
outm
t1A..r
t2 ..r
t2A..r
t1 .l
t1 .H
t2 .l
t2 .H
t1A.l
t1A.H
t2A.l
t2A.H
999. 9
00. 01
pY. Es
up
t1-1
0
npn
10
pY. Es
pY. Es
pY. Es
1
oFF
oFF
0
999. 9
999. 9
999. 9
00. 0
999. 9
00. 0
999. 9
00. 0
999. 9
00. 0
999. 9
1
1
1
1
1
1
1
1
1
1
1
1
1
12
2
1
1
2
2
1
1
2
2
8
8
8
8
8
8
8
8
8
8
8
8
8
8
0
8
8
8
8
8
8
8
8
8
8
8
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2 Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1
Out1 Out1
Out1
Out1
Out1
Out1
Out1
Out1
T1 L o w e r Limit Value
Timer1 setpoint lower limit
can be adjusted between
0 and t1 .H parameter.
T 1 S c a l e S e l e c t i o n
9 Different time periods can
be selected (See Table 1).
If this parameter changed,
t1.L and t1.H parameters
are changed automatically.
Timer1 Configuration Menu
Ou t mod e Se le ct io n
12 Different Out Mode can
be selected. (See graphic
tables )
for output types
Input Filter
0.001, 020, 050 and 0.100
second values can be selected.
Pulse and void time durations
must be greater than adjusted
i.FLt parameters for Start,
Gate and Reset inputs.
Timer Counting Direction
If up is selected, the timer
is counted up, if dn is
se le ct ed th e ti me r is
counted down.
Indicator Format
Sets the selection for the
desir ed param e ters fro m
indicating on top and bottom
display. (See table 2)
This parameter returns to
t1-1 position when outm,
o.1.cn and o.2.cn parameters
are changed. It must be
readjusted to the desired
position.
Security Menu
For accessing this menu,
this parameter must be entered.
Security code is 4400.
T1 (Timer1) Menu, Security Access Level
If nonE Menu invisible.
If P.YEs Modification can be done.
If P. no Only visible.
T2 (Timer2) Menu, Security Access Level
Menu invisible.
Modification can be done.
Only visible.
If nonE
If P.YEs
If P. no
o.cNF
If nonE
If P.YEs
If P. no
Menu, Security Access Level
Menu invisible.
Modification can be done.
Only visible.
d.cNF
If nonE
If P.YEs
If P. no
Menu, Security Access Level
Menu invisible.
Modification can be done.
Only visible.
Input Type Selection
nPn or PnP values can be
se le c t e d . S ta rt , G at e a n d
Rese t input t ypes w ill b e
changed according to th i s
parameter.
Display Brightness Selection
Display brightness can be
adjusted between 1 and 20.
Device Address
ModBus
Commun i cation
address can be
a d j u s t a b l e
b e t w e e n
1 and 247.
Panel Reset Control
If Off is selected, the
reset button not work.
If on is selected and
reset key is pressed for 1
second, timer is reset.
RS485 Baudrate
If oFF is selected ModBus
communication disable.
2400, 4800, 9600, 19200 and
38400 baudrate values can
be adjusted.
O u t 1 S e t t i n g s
May take the t1.on
an d t1.oF v a l u e s.
(For Out1 behavior type,
see out p ut grap hi c
tables.)
Out1 ON, timer settings
If HoLd is selected,
output is continuously
a c t i v a t e d . C a n b e
adjusted between 0.01
and 99.99 seconds.
(
)
For Out1 behavior type,
see o u t p ut g r a p h i c
tables.
Permanent Memory Parameters
If no is selected, in case of
power failure, timer and
switching (contact) settings
will be loss. If YES is
selected, in case of power
failure, last informations will
be stored and process
continues.
selected as t2.on ,
t2.oF or “Out Mode b"
is selected, this menu
can be visible.
If o.2.cn parameter is PRG
s.cnF
Su
Su
Su
Sa
Sa
Sa
Fr
Fr
Fr
Th
Th
Th
We
We
We
Mo
Mo
Mo
Tu
Tu
Tu
Out3
Out3
Out3
Out2
Out2
Out2
Out1
Out1
Out1
99.99s
t1-1
999.9s
t1.1A
t1-2
t1.2A
9999s
t2-2
9959s
t2.2A
999.9
t1.t2
9999
9959
999.9
9999
Between
0.01 sec. and 99.99 sec.
Timer1
Timer1
Timer2
Timer2
Timer1
Timer1
Timer1
Timer2
T1 set
T2 set
T1A set
T2 set
T2A set
T2A set
Between
0.1 sec. and 999.9 sec.
Between
1 sec. and 9999 sec.
Between
1 min. and 9999 min.
Between
0 hr., 01 min.
and
99 hr., 59 min.
Between
0.1 min. and 999.9 min.
Between
0.1 hr. and 999.9 hr.
Between
1 hr. and 9999 hr.
Parameter
Parameter
Adjustable Value
TOP
Display
BOTTOM
Display
m
h
h
h
m
m
m
PROGRAMMING DIAGRAM
h
s
m
Mo Tu We Th Fr Sa Su
8
m
A
h
1
Parameter Setting Diagram
h h h
t1A.l t1A.l t1A.l t1A.l
s s s
m m m
Mo Mo Mo
OUT
MODE
OUT
MODE OUT
MODE
OUT
MODE
Tu Tu TuWe We WeTh Th ThFr Fr FrSa Sa SaSu Su Su
150. 0
150. 0
160. 0
8 8 8
s s s
m m m
T T T T
A A A
PRG PRG PRG PRG
h h h
1 1 1
If held down key, left two digits of selected parameter flashes and by using keys,
desired values can be adjusted. If pressed key, right two digits are flashes and can be adjusted
like left digits.
If key is pressed and held 0.6 seconds, the value of the selected parameter increases rapidly. If
waited
enough,the value increases a hundred at each step. After 1 second, following the release of the key,
h
t1A.l
s
m
Mo
OUT
MODE
Tu We Th Fr Sa Su
165. 9
8
s
m
T
A
PRG h
1
160. 0
s
3/7
0 0 0 0
0
00000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
if key is pressed while holding key, the programming mode is entered.
Entering from the Programming Mode to the Running Mode:
If no key is pressed within 20 seconds during Programming Mode, the data is stored automatically and the Running Mode is entered. Alternatively, the same
function occurs first pressing key, Programming Mode is entered. Then keys are pressed, data is recorded and “Running Mode” is entered
Timer2 Configuration Menu Output Configuration Menu Device Configuration Menu Security Configuration Menu
T 1 A S c a l e S el e c t i o n
9 Different time periods can
be selected (See Table 1).
If this parameter changed,
t1A.L a n d t 1 A . H
p a r a m e t e r s
are changed automatically.
T1A Lowe r Limit Value
Timer1A setpoint lower limit
can be adjusted between
0 and t1 .A parameter.
T1 Upper Lim it Val ue
Timer1 setpoint upper limit
can be adjusted between
and
parameters.
t1 .L t1 .r
T1A Up p er Limit Value
Timer1A setpoint upper limit
can be adjusted between
and
parameters.
t1A.L t1A.r
T 2 S c a l e S e l c t i o n
9 Different time periods can
be selected (See Table 1). If
this parameter changed,
t2.L and t2.H parameters
are changed automatically.
T 2 A S c al e S e l ct io n
9 Different time periods
can be selected (See Table
1). I f thi s par ame ter
ch an ge d , t2 A . L a n d
t2A.H parameters are
T2 L o w e r Limit Value
Timer2 setpoint lower limit
can be adjusted between
0 and t2 .H parameter.
T2A Lower Limit Value
Timer2A setpoint lower
limit can be adjusted
between 0 and t2 .A
parameter.
T2 Upper Limit Value
Timer2 setpoint upper limit
can be adjusted between
and
parameters.
t2 .L t2 .r
T2A Upper Limit Value
Timer2A setpoint upper
limit can be adjusted
between and
parameters.
t2A.L t2A.r
O u t 2 S e t t i n g s
May take the
values. (For Out2
behavior type, see output
graphic tables.)
off, t1.on,
t1.oF, t2.on, t2.oF and
P.on
Out2 ON, Timer Settings
If HoLd is selected, output
is continuously activated.
Can be adjusted between 0.01
and 99.99 seconds. (
)
For Out2
be havior type, see output
graphic tables.
In this position, first key is
pressed and than key is
pressed for 4 seconds, d.PAr. is
0
seen on display and the device is
returned to factory settings.
Scale selection table.
TABEL 1
Parameter selection
table to display
TABLE 2
ATTENTION!
According to the
outm and o.2.cn
parameters some
d i s p l a y m o d e s
invisible
EM4401-EN-01-180308
ENDA
TM

Power Power
Power
Power
Power
Power
Power
Power
Power
Power
o2.cn. = t2.on
o2.cn. = t2.on
o2.cn. = t2.on
o2.cn. = t2.on
o2.cn. = t2.on
o2.cn. = t1.on
o2.cn. = t1.on
o2.cn. = t1.on
o2.cn. = t1.on
o2.cn. = t1.on
If o2.cn. = oFF , Out2 is cancelled
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.on
o2.cn = t1.on
o2.cn = t1.on
o2.cn = t1.on
o2.cn = t1.on
o2.cn = t1.on
o2.cn = t2.on
o2.cn = t2.on
o2.cn = t2.on
o2.cn = t2.on
o2.cn = t2.on
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o2.cn = t1.oF
o2.cn = t1.oF
o2.cn = t1.oF
o2.cn = t1.oF
o2.cn = t1.oF
o2.cn = t2.oF
o2.cn = P.on
o2.cn = P.on
o2.cn = P.on
o2.cn = P.on
o2.cn = P.on
o2.cn = off
o2.cn = off
o2.cn = off
o2.cn = off
o2.cn = off
o2.cn = t2.oF
o2.cn = t2.oF
o2.cn = t2.oF
o2.cn = t2.oF
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o2.cn. = t1.oF.
o2.cn. = t1.oF.
o2.cn. = t1.oF.
o2.cn. = t1.oF.
o2.cn. = t1.oF.
o2.cn. = t2.oF.
o2.cn. = t2.oF.
o2.cn. = t2.oF.
o2.cn. = t2.oF.
o2.cn. = t2.oF.
Start Start
Start
Start
Start
Start
T1 time
T1 time
T1 time
T1 time
T1 time
T2 time
T1 time
T1 time
T1 time
T1 time
T1 time
T1 time
T1 time
T1 time
T2 time
T2 time
T2 time T2 time
T2 time T2 time
Start
Start
Start
Start
Reset
Reset
Reset
Reset
Reset
Out1
Out1
Out1
Out1
Out1
Out1
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out1
Out1
Out1
Out1
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out1
Out1
Out1
Out1
Out1
Out1
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2 power on
Out2 power on
Out2 power on
Out2 power on
Out2 power on
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out1
Out1
Out1
Out1
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
T1
T1
T1
T1
T1
T1
T1
T1
T1
T1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
MODE 0
DELAY with CONSTANT
START ON and RESET
AFTER START
If o1.o.t or o2.o.t
is selected Hold,
output is generated
constantly until OFF
START Input or RESET
Input is taken from
OUT1 or OUT2.
If o1.o.t or o2.o.t
is selected Hold,
Periodically OUT1
is set to ON or OFF
with every
OUT2 is set to ON or OFF
with every T2 time.
T1 time ,
MODE 1
RESET and DELAY
with PULSE START ON
MODE 2
DELAY with START ON/OFF
MODE 3
RESET with START
and DELAY with START OFF
MODE 4
PERIODIC PROCESS
with START PULSE
Pulse output is taken
about o1.o.t lenght
from OUT1.
Pulse output is taken
about
from OUT2.
o2.o.t lenght
o1.cn = t1.on
Up timer is selected
Up timer is selected
Up timer is selected
Down timer is selected
Down timer is selected
Down timer is selected
DETAILED EXPLANATION OUTPUT TYPES GRAPHS - 1 FAST EXPLANATION
NOTE : If Gate in put is active , standby mode is switched in all operating mode. 4/7
TIMER1TIMER2TIMER1TIMER2TIMER1TIMER2TIMER1TIMER2TIMER1TIMER2
If o2.cn. = oFF , Out2 is cancelled
Up timer is selected
Down timer is selected
If o1.o.t or o2.o.t
is selected Hold,
output is generated
constantly until OFF
START Input or RESET
Input is taken from
OUT1 or OUT2.
Pulse output is taken
about
from OUT2.
o2.o.t lenght Pulse output is taken
about o1.o.t lenght
from OUT1.
Up timer is selected
Down timer is selected
If o2.cn. = oFF , Out2 is cancelled If o1.o.t or o2.o.t
is selected Hold,
output is generated
constantly until OFF
START Input or RESET
Input is taken from
OUT1 or OUT2.
Pulse output is taken
about
from OUT2.
o2.o.t lenght
Pulse output is taken
about o1.o.t lenght
from OUT1.
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
If o1.o.t or o2.o.t
is selected Hold,
output is generated
constantly until OFF
START Input or RESET
Input is taken from
OUT1 or OUT2.
Pulse output is taken
about
from OUT2.
o2.o.t lenght
Pulse output is taken
about o1.o.t lenght
from OUT1.
If o2.cn. = oFF , Out2 is cancelled
If o2.cn. = oFF , Out2 is cancelled
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
Pulse output is taken
about
from OUT2.
o2.o.t lenght
Pulse output is taken
about o1.o.t lenght
from OUT1.
T1 time
T1 time T1 time
T1 time T1 time T1 time T1 time
T2 time T2 time
EM4401-EN-01-180308

Power
Power
o2.cn. = t2.on
o2.cn. = t1.on
o1.cn = t1.on
o2.cn = t1.on
o2.cn = t2.on
o1.cn = t1.on
o1.cn = t1.oF
o2.cn = t1.oF
o2.cn = t2.oF
o1.cn = t1.oF
o2.cn. = t1.oF.
o2.cn. = t2.oF.
Start
T1 time
T2 time T2 time T2 time
Start
Reset
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
T1
T1
0
0
0
0
T2
T2
If o1.o.t or o2.o.t
is selected Hold,
Periodically OUT1 is
set to ON or OFF with
every T1 time,OUT2 is
set to ON or OFF with
every T2 time while
START signal is ON.
MODE 5
PERIODIC PROCESS with
CONSTANT START and
RESET AFTER START
Power
Power
Power
Power
o2.cn. = t2.on
o2.cn. = t2.on
o2.cn. = t1.on
o2.cn. = t1.on
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.on
o1.cn = t1.on
o2.cn = t1.on
o2.cn = t1.on
o2.cn = t2.on
o2.cn = t2.on
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o1.cn = t1.oF
o2.cn = t1.oF
o2.cn = t1.oF
o2.cn = t2.oF
o2.cn = t2.oF
o2.cn. = t1.oF.
o2.cn. = t1.oF.
o2.cn. = t2.oF.
o2.cn. = t2.oF.
Start
Start
Start
Start
T1 = a + b
T1 = a + b
T1 = a + b
T1 = a + b
T2 = a + c
T2 = a + c
Reset
Reset
Out1
Out1
Out1
Out1
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out1
Out1
Out1
Out1
Out2
Out2
Out2
Out2
Out2
Out2
Out2
Out2
T1
T1
T1
T1
0
0
0
0
0
0
0
0
T2
T2
T2
T2
If o1.o.t or o2.o.t
is selected Hold,
Constant output is
taken until RESET Input
is set to ON from
OUT1 or OUT2.
If o1.o.t or o2.o.t
is selected Hold,
Constant output is
taken until START Input
or RESET Input is set to
ON from OUT1 or OUT2.
MODE 6
TIMING with START
MODE 7
RESET with START
after TIMING with START
a
a
a
a
a
a
b
bd
d
d
b
b
c
c
delay
delay
delay
delay
delay
delay
DETAILED EXPLANATION FAST EXPLANATION
Power
Power
o2.cn. = t2.on
o2.cn. = t1.on
o1.cn = t1.on
o2.cn = t1.on
o2.cn = t2.on
o1.cn = t1.on
o1.cn = t1.oF
o2.cn = t1.oF
o2.cn = t2.oF
o1.cn = t1.oF
o2.cn. = t1.oF.
o2.cn. = t2.oF.
Start
T1 time
T2 time T2 time
Start
Reset
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
T1
T1
0
0
0
0
T2
T2
If o1.o.t or o2.o.t
is selected Hold,
OUT1 is set ON or OFF
about T1 lenght ,
OUT2 is set ON or OFF
about T2 lenght when
START Input is set to
ON .
MODE 8
SINGLE PERIOD TIMING
with START ON
Power
Power
o2.cn. = t2.on
o2.cn. = t1.on
o1.cn = t1.on
o2.cn = t1.on
o2.cn = t2.on
o1.cn = t1.on
o1.cn = t1.oF
o2.cn = t1.oF
o2.cn = t2.oF
o1.cn = t1.oF
o2.cn. = t1.oF.
o2.cn. = t2.oF.
Start
T1 time
T2 time T2A time T2 time
T1A time T1 time T1A time
Start
Reset
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
TIMER1 TIMER2 TIMER1 TIMER2 TIMER1 TIMER2 TIMER1 TIMER2 TIMER1
TIMER2
Out2
T1
T1A
T1A
T1
0
0
0
0
T2
T2A
T2A
T2
MODE 9
ON-OFF TIME
PERIODIC PROCESS
with START PULSE
OUTPUT TYPES GRAPHS - 2
5/7
o2.cn = off
o2.cn = off
o2.cn = off
o2.cn = off
o2.cn = off
Out2
Out2
Out2
Out2
Out2
o2.cn = P.on
o2.cn = P.on
o2.cn = P.on
o2.cn = P.on
o2.cn = P.on
Out2
Out2
Out2
Out2
Out2
Out2 power on
Out2 power on
Out2 power on
Out2 power on
Out2 power on
EM4401-EN-01-180308
T1 time T1 time T1 time
T1 time T1 time T1 time T1 time
Up timer is selected
Down timer is selected
If o2.cn. = oFF , Out2 is cancelled
Pulse output is taken
about
from OUT2.
o2.o.t lenght
Pulse output is taken
about o1.o.t lenght
from OUT1.
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
If o2.cn. = oFF , Out2 is cancelled
Up timer is selected
Down timer is selected
Pulse output is taken
about
from OUT2.
o2.o.t lenght
Pulse output is taken
about o1.o.t lenght
from OUT1.
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
If o2.cn. = oFF , Out2 is cancelled
Pulse output is taken
about
from OUT2.
o2.o.t lenght Pulse output is taken
about o1.o.t lenght
from OUT1.
If o2.cn. = oFF , Out2 is cancelled
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
T1 time
T1 time
T1 time
Pulse output is taken
about o1.o.t lenght
from OUT1.
Pulse output is taken
about
from OUT2.
o2.o.t lenght
T1 time T1 time
T1A time T1A time
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
If o2.cn. = oFF , Out2 is cancelled
NOTE : If Gate in put is active , standby mode is switched in all operating mode.

Power
Power
o2.cn. = t2.on
o2.cn. = t1.on
o1.cn = t1.on
o2.cn = t1.on
o2.cn = t2.on
o1.cn = t1.on
o1.cn = t1.oF
o2.cn = t1.oF
o2.cn = t2.oF
o1.cn = t1.oF
o2.cn. = t1.oF.
o2.cn. = t2.oF.
Start
T1 time
T1 time
T2 time T2A time T2-x
T1A time
T1A time
T1 time
T1 time T1-x
T1-x
Start
Reset
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
Out1
Out2
Out2
T1
T1A
T1A
T1
0
0
0
0
T2
T2A
T2A
T2
MODE A
ON-OFF TIME PERIODIC PROCESS
with CONSTANT START and
RESET with START OFF
DETAILED EXPLANATION FAST EXPLANATION
x = Unknown time
Power
Power
Power
o2.cn. = t2.on
ATTENTION! In order to choose this mode , . parameter must be setted to or .o2.cn t2.on t2.of
o1.cn = t1.on
o2.cn = t2.on
o1.cn = t1.on
o1.cn = t1.oF
o2.cn = t2.oF
o1.cn = t1.oF
o2.cn. = t2.oF.
Start
Start
Reset
Out1
Out2
Out2
Out1
Out1
Out2
Out1
Out2
Out2
T1
T1
T2
T2
T1A
T1A
T2A
T2A
0
0
MODE B
ON-OFF TIME
DOUBLE CONTACT
DOUBLE PERIODIC
PROCESS with
START PULSE
T1
time
T1
time T1A
time T1A
time
T2
time
T2
time
T2A
time
NOTE 2 : If o2.cn parameter is set to P.on , then Out2 output is activated and remains until power down.
In this setup , Out2 output is used in order to observe power state of timer. Other Out2 functions can not be used.
OUTPUT TYPES GRAPHS - 3
TIMER1
TIMER2TIMER1
o2.cn = off
Out2
o2.cn = P.on
Out2
Out2 power on
Up timer is selected
Down timer is selected
Up timer is selected
Down timer is selected
If o2.cn. = oFF , Out2 is cancelled
Up timer is selected
Down timer is selected
NOTE 1 : If Gate in put is active , standby mode is switched in all ‘‘Operating Mode’’.
Power Power
o2.cn. = t2.on
o2.cn. = t1.on
if o2.cn. = oFF Out2 is cancelled
o1.cn = t1.on
o1.cn = t1.on
o2.cn = t1.on
o2.cn = t2.on
o1.cn = t1.oF
o1.cn = t1.oF
o2.cn = t1.oF
o2.cn = t2.oF
o2.cn. = t1.oF.
o2.cn. = t2.oF.
Start Start
T1 = a + b
T1 = a + b
T2 = a + c
Reset
Out1
Out1
Out2
Out2
Out2
Out2
Out1
Out1
Out2
Out2
Out2
Out2
T1
T1
0
0
0
0
T2
T2
If o1.o.t or o2.o.t
is selected Hold ,output
is generated constantly
until ON START Input or
RESET Input is taken
from OUT1 or OUT2.
Up timer is selected
Up timer is selected
Down timer is selected
Down timer is selected
MODE C
RESET with START OFF
after TIMING with start
a
a
a
bd
d
d
b
c
delay
delay
delay
TIMER2 TIMER1
o2.cn = off
Out2
o2.cn = P.on
Out2
Out2 power on
Pulse output is taken
about o1.o.t lenght
from OUT1.
Pulse output is taken
about
from OUT2.
o2.o.t lenght
6/7
EM4401-EN-01-180308
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18 ENDA
TM

SENSOR CONNECTION SAMPLES
+ 12V
GND
+ 12V + 12V
1 1
1 1
1111
1111
12 12
12 12
13 13
13 13
14 14
14 14
15 15
15 15
16 16
16 16
2 2
2 2
3 3
3 3
4 4
4 4
5 5
5 5
6 6
6 6
7 7
7 7
8 8
8 8
9 9
9 9
10 10
10 10
230V AC Supply
230V AC Supply
230V AC Supply 230V AC Supply
Switch Anahtar
Cable size: 1,5mm² Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse
F 100 mA
250V AC
Typical connections for PNP sensor type Typical connections for NPN sensor type
PNP PROXIMITY SWITCH NPN PROXIMITY SWITCH
GND GND
Start Start
RESET RESET
START START
GATE GATE
OUT (Active level is sensor
supply voltage) OUT (Active level GND)
Flush
mounting
clamp
Panel
58mm
CONNECTION DIAGRAM
230V AC
or
21.6-26.4V AC
50/60Hz 5VA
SUPPLY :
NOTE :
48mm
DIMENSIONS
12
11
80mm
Connection
Cables
+0.6
45 mm
45 mm
+0.6
Panel cut-out
230V AC or 24V AC
Supply
1
1
51mm
Depth
87mm
2
Note :
Logic output of the device is not electrically isolated.
Therefore, the logic output terminals should not be
grounded when using grounded thermocouples.
1) Mains supply cords shall meet the requirements of
IEC60227 or IEC60245.
2) In accordance with the safety regulations, the power
supply switch shall bring the identification of the relevant
instrument and it should be easily accessible by the
operator.
Vida sıkma momenti
0.4-0.5Nm
For removing mounting clamps ;
Cihazın tümünde ÇİFT
YALITIM vardır.
Mo Tu We Th Fr Sa Su
Out1
Out2
Out3
s
s
m
m
h
Mo
T
A
PRG
OUT
MODE
Tu We Th Fr Sa Su
h
Start
Reset
Gate
Em4401
ENDA
DIGITAL TIMER
0
Switch
Fuse
F 100 mA
250V AC
Switch
Fuse
F 100 mA
250V AC
Cable size: 1,5mm²
Cable size: 1,5mm²
- Push the device in direction 1 as
shown in the figure.
- Then pull out the device in direction 2 .
Note :
1) While performing panel mounting,additional
space should be allocated for cables.
2) Panel thickness should be maximum 9mm.
3) If there is no 100mm free space at back
side of the device, it would be difficult to
remove it from the panel.
ENDA EM4401 is intended for installation within
control panels. Make sure that the device is used
only for intended purpose. The shielding
must be grounded on the instrument side.
installation, all of the cables that are connected to the
device must be free of electrical power. The device must
be protected against inadmissible humidity, vibrations,
severe soiling. Make sure that the operation
temperature is not exceeded. All input and output lines that
are not connected to
During an
the supply network must be laid out as
shielded and twisted cables. These cables should not be
close to the power cables or components. The installation
and electrical connections must be carried out by a qualified
staff and must be according to the relevant locally
applicable regulations.
Phase
Neutral
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
7/7
EM4401-EN-01-180308
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18 ENDA
TM
EM4401-230VAC
DIGITAL TIMER
INDUSTRIAL
ELECTRONICS
ENDA
SN: XXXXXXXXX
MADE IN TURKEY
SSR2 OUT
SSR1 OUT
RESET IN
START IN
GATE IN
GND
+12V 50mA
1
2
3
4
5
6
7
8
9
10
8 680407 718795
OUT1
OUT2
AC 250V 10A
RESISTIVE
LOAD
AC 250V 5A
RESISTIVE
LOAD
11
12
13
16
14
15
17
230V AC
50/60Hz 5VA
-
+RS- 485
A
B
RS-485 COM.
8 680407 718801
EM4401-230VAC-RS
DIGITAL TIMER
INDUSTRIAL
ELECTRONICS
ENDA
SN: XXXXXXXXX
MADE IN TURKEY
SSR2 OUT
SSR1 OUT
RESET IN
START IN
GATE IN
GND
+12V 50mA
1
2
3
4
5
6
7
8
9
10
OUT1
OUT2
AC 250V 10A
RESISTIVE
LOAD
AC 250V 5A
RESISTIVE
LOAD
11
12
13
16
14
15
17
230V AC
50/60Hz 5VA

Holding Register
addresses
Decimal (Hex)
Parameter
Number
Data
Type Data Content
Read / Write
Permission
Factory
Defaults
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
0000d (0000h) 10
30
100
1
1
0
0
0
0
9999
9999
0
0
0
1
0
0
0
0
1
3
1
1
1
1
0
1
10
9999
9999
15
0002d (0002h)
0003d (0003h)
0004d (0004h)
0005d (0005h)
0006d (0006h)
0007d (0007h)
0008d (0008h)
0009d (0009h)
0010d (000Ah)
0001d (0001h)
0011d (000Bh)
0012d (000Ch)
0013d (000Dh)
0014d (000Eh)
0015d (000Fh)
0016d (0010h)
0017d (0011h)
0018d (0012h)
0019d (0013h)
0020d (0014h)
0022d (0016h)
0021d (0015h)
1.1 Memory Map for Timer Holding Registers
H0
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
H16
H17
H18
H19
H20
H21
H23
H22
H24
H25
H26
H27
H28
H29
H30
Timer1 Configuration Parameters
Device Configuration
Security Parameters
Output Parameters
Setpoint for T1 time (Adjustable between 0-9999d. Format : BCD = 0-9999d)
E.g. : Adjusting for 259 seconds MSB = 02h, LSB = 59h
Minimum setpoint value limit for T1 time. (Format must be as in the H0 parameter)
Maximum setpoint value limit for T1 time. (Format must be as in the H0 parameter)
Outpu type parameter. Can be adjusted between 0 and 11. See graphic tables for output types
T1 (Timer1) Menu, security access level parameter. Adjustable between 0 and 2.
0 = Menu invisible, 1 = Modification can be done, 2 = Menu parameters only visible.
Display luminous intensity setting parameter. Can be adjusted between 1 and 20.
Display configuration parameter. Adjustable between 0 and 6. See TABLE 2 for selection.
Minimum puls duration time parameters for RESET, START and GATE inputs.
0 = 1ms, 1 = 20ms, 2 = 50ms, 3 = 100ms
OUT1 Configuration parameter. Can be adjusted between 0 and 2. See graphic tables for output types
Setpoint for T1A time ( Format must be as in the H0 parameter)
Setpoint for T2 time ( Format must be as in the H0 parameter)
Setpoint for T2A time ( Format must be as in the H0 parameter)
Setpoint for T1 time base
0 = 99.99sec, 1 = 999.9sec, 2 = 9999sec, 3 = 99m59sec, 4 = 999.9min
5 = 9999min, 6 = 99h59min, 7 = 999.9hr, 8 = 9999hr.
Setpoint for T1A time base. (Format must be as in the H2 parameter).
Word
0023d (0017h)
Word
0024d (0018h)
Word
0025d (0019h)
Word
0026d (001Ah)
Word
0027d (001Bh)
Communication speed for :
0 = 1200 bps, 1 = 2400 bps, 2 = 4800 bps, 3 = 9600 bps,
4 = 14400 bps, 5 = 19200 bps, 6 = 38400 bps, 7 = 57600 bps
Device address values for Modbus. (Adjustable between 1 and 247)
Word
0028d (001Ch)
Word
Word
0029d (001Dh)
0030d (001Eh)
1.2 Memory Map for Control Coils
Parameter
Number
Data
Type
R W
R W
R W
R W
R W
R W
C0
C1
C2
C3
C4
C5-C15
Timer counting direction (0 = Count UP ,1 = Count DOWN)
Data storage in case of power failure (Permanent memory parameters)
0 = Storing data enabled (Possible), 1 = Storing data disabled (Not Possible).
Sensor type selection. (0 = NPN ,1 = PNP)
Panel RESET activation. ( 0 = Reset key inactive, 1 = Reset key is active )
Reserve
Reserve
Bit
Bit
Bit
Bit
Bit
Bit
Coil Addresses
Decimal (Hex)
0
0
0
0
X
0
0000d (0000h)
0001d (0001h)
0002d (0002h)
0003d (0003h)
0004d (0004h)
0005d (0005h)
0015d (000Fh)
....... ......
Function control parameter.
If 23040d (5A00h) value is entered, device is returned to factory settings.
ENDA EM4401 DIGITAL TIMER MODBUS ADRESS MAP
Minimum setpoint value limit for T1A time. (Format must be as in the H0 parameter)
Maximum setpoint value limit for T1A time. (Format must be as in the H0 parameter)
Setpoint for T2 time base. (Format must be as in the H2 parameter).
Setpoint for T2A time base. (Format must be as in the H2 parameter).
Minimum setpoint value limit for T2 time. (Format must be as in the H0 parameter)
Maximum setpoint value limit for T2 time. (Format must be as in the H0 parameter)
Minimum setpoint value limit for T2A time. (Format must be as in the H0 parameter)
Maximum setpoint value limit for T2A time. (Format must be as in the H0 parameter)
OUT2 Configuration parameter. Can be adjusted between 0 and 4. See graphic tables for output types
OUT1 Contact output duration. Adjustable between 0.00 and 99.99 sec. ( 0 = Hold)
Format: BCD = 99h, MSB = 99h
E.g. : Adjusting for 12.50sec., MSB 12hr, LSB = 50hr
OUT2 Contact output duration. Adjustable between 0.00 and 99.99 sec. ( 0 = Hold)
(Format must be as in the H19 parameter)
T2 (Timer2) Menu, security access level parameter. Adjustable between 0 and 2.
0 = Menu invisible, 1 = Modification can be done, 2 = Menu parameters only visible.
Output configuration menu, security access level parameter. Adjustable between 0 and 2.
0 = Menu invisible, 1 = Modification can be done, 2 = Menu parameters only visible.
Device configuration menu, security access level parameter. Adjustable between 0 and 2.
0 = Menu invisible, 1 = Modification can be done, 2 = Menu parameters only visible.
Timer2 Configuration Parameters
Data Content
Read / Write
Permission
Factory
Defaults
1 / 2
EM4401-EN-01-180308
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
Barbaros Cad. No:18 ENDA
TM

R
R
R
R
1.3 Memory Map for Input Registerlers
Word
0000d (0000h)
I0 Timer1 time value (Must be read according to BCD format)
Word
Word
Word
0001d (0001h)
0002d (0002h)
0003d (0003h)
0007d (0007h)
0015d (000Fh)
I1
I2
I3
Timer2 time value (Format is as in the I0 parameter)
Out1 puls time value (Must be read according to BCD format. Sensitivity 0.00sn )
Out2 puls time value (Format is as in the I2 parameter)
1.4 Memory Map for Output Status Indicator Bits
R
R
R
R
R
R
R
R
OUT1 Output status (0 = OFF ,1 = ON)
OUT2 Output status (0 = OFF , 1 = ON )
Panel reset key status ( 0 = Reset key inactive, 1 = Reset key is active )
Reserve
Reset input status ( 0 = Reset input inactive, 1 = Reset input is active )
Gate input status ( 0 = Gate input inactive, 1 = Gate input is active )
Start input status ( 0 = Start input inactive, 1 = Start input is active )
Reserve
D0
D1
D2
D3
D4
D5
D6
D7-D15
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
(0000)h
(0001)h
(0002)h
(0003)h
(0004)h
(0005)h
(0006)h
1.5 Memory Map for Software Revision Input Registers
14
Word
Word
1
NOTE :
To view each word correctly by changing the byte sequences should be displayed as ASCII TEXT
Word
2
Word
3
Word
4
Word
5
Word
6
Word
7
Word
8
Word
9
Word
10
Word
11
Word
12
Word
13
Word
14
0920d (0398h)
Software
Revision
R
Software name and update date is in ASCII format and 14 word.
Example : EM4401-01 25 March 2016.
Memory Format :
E41-12r206
M4005Ma1.
...... .......
ENDA EM4401 DIGITAL TIMER MODBUS ADRESS MAP
Holding Register
addresses
Decimal (Hex)
Parameter
Number
Data
Type Data Content
Read / Write
Permission
Discrete input
addresses
Parameter
Number
Data
Type Data Content
Read / Write
Permission
2. MODBUS ERROR MESSAGES
Modbus protocol has two types error, communication error and operating error. Reason of the communication error is data corruption in transmission. Parity
and CRC control should be done to prevent communication error. Receiver side checks parity and CRC of the data. If they are wrong, the message will be
ignored. If format of the data is true but function doesn’t perform for any reason, operating error occurs. Slave realizes error and sends error message. Most
significant bit of function is changed '1' to indicate error in error message by slave. Error code is sent in data section. Master realizes error type via this
message.
Error Code Meaning
Name
ILLEGAL FUNCTION
ILLEGAL DATA ADDRESS
ILLEGAL DATA VALUE
01
02
03
The function code received in the query is not an allowable action for the slave. If a
Poll Program Complete command was issued, this code indicates that no program
function preceded it.
The data address received in the query is not an allowable address for the slave.
A value contained in the query data field is not an allowable value for the slave.
Device Address
Function Code
Beginning address
of coils.
Number of coils (N)
CRC DATA
MSB
LSB
MSB
LSB
LSB
MSB
Structure of command message (Byte Format)
(0A)h
(01)h
(04)h
(A1)h
(00)h
(01)h
(AC)h
(63)h
Device Address
Function Code
CRC DATA LSB
MSB
Structure of response message (Byte Format)
(0A)h
(81)h
(02)h
(B0)h
(53)h
Error Code
Message example;
As you see in command message, coil information of (4A1)h = 1185 is required but there isn’t any coil with 1185 address. Therefore error code with number (02)
(Illegal Data Address) sends.
ModBus Error Codes
2 / 2
EM4401-EN-01-180308
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Şerifali Mah. Y.Dudullu 34775
ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01