Step 1
Release the front half by loosen the screw from the boom of
the thermostat. Then carefully pull and separate the front part
away from the back-plate, inially from the lower part of the
thermostat.
Step 2
Place the front part of the thermostat in a safe place, to prevent
scratches and damage. Connect the wires in accordance with
the diagram on page 2. The wiring diagram must be followed.
Step 3
Screw the thermostat back-plate onto the recessed juncon box
in the wall. Use the supplied screws or the original screws of the
juncon box.
Step 4
When the back-plate is secure, ret the front part carefully to
the back-plate, starng with the upper part of the thermostat,
and gently ghten the boom retaining screw.
The thermostats is now ready to operate.
INSTALLATION INSTRUCTION
Thank you for the purchase of our product. Please read the
instrucon before mounng and installing.
The device is an electronic thermostat for temperature control
by means of NTC sensors, located either internally within the
thermostat or externally by sensors.
PRODUCT PROGRAM
T60-EH
Mul-funconal thermostat with built-in sensor and
ability of two external sensors, oor and/or air.
Without Wi-Fi funcon.
T60-EW
Mul-funconal thermostat with built-in sensor and
ability of two external sensors, oor and/or air.
With Wi-Fi funcon.
ES-T60 Accessory, external oor sensor probe, NTC 10 kΩ.
3 m connecon cable.
WARNING – Important Safety Instrucons
Disconnect the power supply before carrying out
any installaon or maintenance work,on this ther-
mostat and/or associated components.
The thermostat, and the associated components,
should only be installed by a qualied and autho-
rized electrician.
Electrical installaon must be in accordance with
appropriate naonal regulaons.
MOUNTING OF THE THERMOSTAT
The thermostat is designed to be ush mounted, and requires a
minimum 35 mm deep juncon box, recessed, within the wall.
PLACEMENT OF THE THERMOSTAT
The thermostat should be placed on the wall, approximately
1.5 m above the oor level, when the built-in sensor is used for
temperature regulaon. Ensure and allow free air circulaon
around it. Draught and direct sunlight, or other heat sources,
must be avoided. It can aect thermostat funcons.
When using a oor sensor, it is strongly recommended to follow
the underoor heang supplier’s advice and instrucons.
The sensor cable, of the accessory ES-T60, may be extended up
to 50 m by means of a separate two-core cable.