ENFORCER SD-6176-SSVQ User manual

Outdoor Piezoelectric
Request-to-Exit Pushbuttons
Manual
SD
-
6
176
-
SSVQ
Slim
line plate, manual override
SD
-
6276
-
SSVQ
Single
-
gang plate, manual override
SD
-
6176
-
SS1Q
Slimline plate, "EXIT/SALIDA"
SD-6276-SS1Q Single-gang plate, "EXIT/SALIDA"
SD
-
6176
-
SSQ
*
Slimline plate, "TOUCH/EXIT"
SD-6276-SSQ* Single-gang plate, "TOUCH/EXIT"
 Piezoelectric push buttons for indoor or
outdoor use (IP65, except models with
manual override button)
 LED ring around button changes from
green to red or red to green when the
button is pressed
 Timed or toggle output
 Available with separate manual override button
in case power to piezoelectric pushbutton fails
 SPDT Relay rated 2.5A@24 VAC/VDC with
two individually programmable outputs
(NO/NC)
*
Special order item. Please contact SECO-LARM.
5024193
Conforms to
UL
Std.
294
ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
2 SECO-LARM U.S.A., Inc
Specifications: Parts List:
Operating voltage
12~24 VDC
Current drain 40mA@12VDC
Contact
rating
2.5A@24 VAC/
VDC
Ring LED
Colors reversible via switch
Standby Red
Active Green
Output time
1~30 s, Toggle
Destructive attack level
Level I
Line security
Level I
Endurance level
Level I
Standby power
Level I
IP rating
IP65
Weatherproof
*
Operating temperature
32
°
~158
°
F (0
°
~70
°
C)
Plate material Stainless steel
Weight
Single
-
Gang
3.5
-
oz (99g)
Single
-
Gang
w/Manual Override
4
-
oz (113g)
Slimline 2.6-oz (74g)
Slimline
w/Manual Override
3.1
-
oz (88g)
*When properly installed †SD-6176-SSVQ and SD-6276-SSVQ only
Overview:
SD-6176-SSVQ and SD-6276-SSVQ with Manual Override button shown, other models similar.
‡SD-6176-SSVQ and SD-6276-SSVQ only
Installation:
1. Prepare wiring to provide 12~24 VDC power and connect devices to the relay outputs. Use only low-
voltage, power-limited/Class 2 power supply and low-voltage field wiring not to exceed 98.5ft (30m).
NOTE: The device includes one relay with two outputs. Outputs trigger simultaneously or independently.
To set the output modes, see "Configuring the Pushbutton: Relay Output Modes" on pg. 3.
2. Remove the plastic cover from the rear of the switch and carefully pierce the rubber grommet.
3. SD-6176-SSVQ and SD-6276-SSVQ: Wire the manual override button. See pg. 3.
4. Wire the switch according to the diagram on the right.
 Connect (-) and (+) to a 12~24 VDC power source.
 Connect other devices to Outputs 1 or 2.
5. Replace the plastic switch cover.
6. For weatherproof installation, use a waterproof backbox and
apply a bead of silicone sealant (not included) around the rim of the backbox and faceplate edge. Apply a
small amount of sealant below each screw head.
7. Screw the plate into the back-box, taking care not to crimp the wires and ensuring a good seal.
Single-Gang Slimline
41/2”
(114mm)
LED ring
Manual
override
button‡
Piezo-
electric
pushbutton
15/8” (42mm)
23/4” (70mm)
15/8” (42mm)
Side View Rear View
(Plastic switch
cover removed)
Relay adjustment
Output mode
selection
Terminal blocks
Manual override
button
‡
Buzzer adjustment
LED color
selection
Timer adjustment
1x
Piezoelectric
pushbutton
2x
Mounting
screws
2x
Override
wires†
1x
Manual
Terminal Block
1 2
ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
SECO-LARM U.S.A., Inc 3
Wiring the Manual Override: SD-6176-SSVQ and SD-6276-SSVQ Only
Connect the manual override button with the included wires.
NOTES
a. Remove the thin panel on the bottom of the plastic cover to allow wiring to pass through.
b. There is only one relay, wiring the button to either output will allow the other output to trigger simultaneously.
c. Do not connect the manual override button to more than one output.
d. When wiring for either N.O. or N.C., be sure to also set the Relay Output Mode to N.O., as described below.
If Relay Output Mode and override button wiring do not match, the product may not function as expected.
Configuring the Pushbutton:
1. Buzzer Output DEFAULT: ON
Use the buzzer output jumper JP3 to program the buzzer output.
Placing the jumper on the left turns the buzzer output ON. Placing the
jumper on the right turns the buzzer output OFF.
2. Relay Output Mode DEFAULT: N.O.
Outputs 1 and 2 can be set independently using jumpers
JP1 and JP2. Note: Both outputs trigger simultaneously.
Place the jumper on the right for N.O. operation and on the
left for N.C. operation.
3. LED Ring Colors DEFAULT: OFF
ON: LED is green while in standby and turns red when triggered.
OFF: LED is red while in standby and turns green when triggered.
4. Switch Output Type DEFAULT: Timer
TIMER: When set to TIMER, pressing the switch will trigger the relay for
the set duration. Set the time using the trimpot as described below.
TOGGLE: When set to TOGGLE, pressing the switch will cause the
relay to trigger until the switch is pressed again.
5. Output Duration Adjustment DEFAULT: 1s
Output duration is adjustable 1~30 seconds. (Must be set to ‘Timer’ in step 4)
Gently rotate the trimpot using a Philips head screwdriver.
Counterclockwise decreases the output time.
Clockwise increases the output time.
Wiring For N.O.:
Connect the two
wires between the
NO and COM
terminals of the
override button and
the Output 1 or 2
terminals on the
switch.
Wiring For N.C.:
Connect the two
wires between
the NC and COM
terminals of the
override button
and the Output 1
or 2 terminals on
the switch.
Manual
Override Button
N.C.
COM
N.O.
COM
ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
4 SECO-LARM U.S.A., Inc
Sample Installation: Electromagnetic Lock (Fail-Safe) with Strobe Light
NOTE: No wiring may exceed 98 ft (30m) in length.
California Proposition 65 Warning: These products may contain chemicals which are known to the State of California to
cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
IMPORTANT WARNING: For a weatherproof installation, ensure the unit is installed in a waterproof backbox, and that
the faceplate and faceplate screws are properly sealed. Incorrect mounting may lead to exposure to rain or moisture in
the enclosure which could cause a dangerous electric shock, damage the device, and void the warranty. Users and
installers of this product are responsible for ensuring this product is properly installed and sealed.
IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of
this product complies with all national, state, and local laws and codes. SECO-LARM will not be held responsible for the
use of this product in violation of any current laws or codes.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if
damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such
equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole
obligation of SECO-LARM and the purchaser’s exclusive remedy, shall be limited to the replacement or repair only, at
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM
reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints.
Copyright © 2023 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole
or in part, without the written permission of SECO-LARM.
SECO-LARM ® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
ENFORCER
Electromagnetic Lock
ENFORCER
LED Strobe Light
MI_SD-6x76-SSxQ_220908.docx
PI
H
W
K1

This manual suits for next models

5

Other ENFORCER Control Unit manuals

ENFORCER SA-025 User manual

ENFORCER

ENFORCER SA-025 User manual

ENFORCER SD-7202GC-PEQ User manual

ENFORCER

ENFORCER SD-7202GC-PEQ User manual

ENFORCER ST-BD01Q User manual

ENFORCER

ENFORCER ST-BD01Q User manual

Popular Control Unit manuals by other brands

Eaton 33 manual

Eaton

Eaton 33 manual

remel Xpect RSV Control Kit General information

remel

remel Xpect RSV Control Kit General information

Ducati Desmosedici 2008 installation instructions

Ducati

Ducati Desmosedici 2008 installation instructions

Arbor Technology Em104-a5362 Quick installation guide

Arbor Technology

Arbor Technology Em104-a5362 Quick installation guide

Bender ISOMETER iso685 -CN Series quick start guide

Bender

Bender ISOMETER iso685 -CN Series quick start guide

System Sensor M501MAP Installation and maintenance instructions

System Sensor

System Sensor M501MAP Installation and maintenance instructions

Grundfos Unilift AP12 Installation and operating instructions

Grundfos

Grundfos Unilift AP12 Installation and operating instructions

LS LSUM 051R3C 0166F EA user manual

LS

LS LSUM 051R3C 0166F EA user manual

Draper ER manual

Draper

Draper ER manual

SMART PCM11-i5 user guide

SMART

SMART PCM11-i5 user guide

Allen-Bradley ArmorBlock 1732E-8IOLM12R installation instructions

Allen-Bradley

Allen-Bradley ArmorBlock 1732E-8IOLM12R installation instructions

ST X-NUCLEO-LPM01A user manual

ST

ST X-NUCLEO-LPM01A user manual

Glenayre @ctiveLink User guide and technical information

Glenayre

Glenayre @ctiveLink User guide and technical information

AFRISO ACU 2030 user guide

AFRISO

AFRISO ACU 2030 user guide

Kramer TBUS-202xl user manual

Kramer

Kramer TBUS-202xl user manual

Burkert 3270 quick start

Burkert

Burkert 3270 quick start

Allen-Bradley OptiSIS 1711-P05SISID050S user manual

Allen-Bradley

Allen-Bradley OptiSIS 1711-P05SISID050S user manual

Komatsu D375A-5 Operation & maintenance manual

Komatsu

Komatsu D375A-5 Operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.