ENFORCER ENFORCER SK-B141-DQ User manual

Getting Started
:
Bluetooth
®
Access Controllers
The Bluetooth
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks
by SEC -LARM is under license. ther trademarks and trade names are those of their respective owners.
Get the complete Installation
Manual, SL Access
App User
Manual, and more at
SECO-LARM's website.
Download the SL Access™ app from the
corresponding store for your phone
(iOS 11.0 and above, Android 5.0 and above).
NOTES:
a. Be sure to set your smartphone to automatically download app updates so that you always have the
latest version of the app.
b. The app will appear in your device's default language if available. If the app does not support your device
language, it will default to English.
Quick Installation/Setup Guide
Bluetooth
®
Access
Control
lers
™
SL Access

ENFORCER Bluetooth
®
Access Controllers
2SECO-LARM U.S.A., Inc.
This manual is for installers looking to do a basic installation and setup of the ENF RCER Bluetooth
®
keypad/reader (SK-B141-DQ shown, others similar). For more in-depth installation and advanced
programming instructions, see the corresponding product page at www.seco-larm.com.
Quick Installation:
Remo e Back
Use the security screw bit to
remove the security screw and
remove the housing back.
Mark Holes for Drilling
Hold the back in the desired
mounting place, mark mounting
and wiring holes.
Drill Holes
Drill the five holes. The wiring
hole should be at least 11/4"
(3cm) in diameter.
At
least
11/4" (3cm)
5/16" (8mm)
Red
:
Power (+) polarity
insensitive
Black
:
Power (
–
) polarity insensitive
Yellow
:
NC (fail
-
safe)
White
:
C M
Blue
:
N (fail
-
secure)
Green
:
RTE
Green
:
RTE
Brown
:
Door Sensor
Brown
:
Door Sensor
Orange
:
Alarm
Orange
:
Alarm
1.
Feed Wires into Wall
Push connected wires through
the hole in the wall, taking care
not to loosen any connectors.
2.
Mount Back to Wall
Mount the back to the wall
using the supplied screws and
wall anchors or other screws.
3.
Mount Keypad to Back
Slide the device to engage the
tab on the top of the back, and
secure with the security screw.
Wir
e
the Keypad/Reader
Connect using the yellow for fail-safe and the blue for fail-secure locks. A diode is
also required for
DC and a varistor for maglocks or AC strikes. See full Installation Manual online for details.

ENFORCER Bluetooth
®
Access Controllers
SECO-LARM U.S.A., Inc. 3
SL Access
Quick Setup:
Understanding the SL Access Home Screen
"Login" icon "Device Name" "Settings" icon
"Current Device Distance"
with a number showing
"Locked" icon
"Auto Proximity Range"
showing the current setting
"Auto" selector
NOTES:
a. n opening the app, you may get a
message asking you to enable
Bluetooth. Bluetooth must be
enabled to use the app and the
device must be in range.
b. You may see the word
"Searching…" at the top of the
screen (see below
). Bluetooth has a
limited range of about 60 feet
(20m), but will be much less in
practice. Move closer to the device,
but if "Searching…," continues to
show you may need to exit and
reopen the app.
❽
App version number
Log In to the De ice
NOTES:
a. The administrator's ID is ADMIN
and cannot be changed.
b. The factory default passcode
should be changed from the
"Settings" page immediately for
better security (see pg. 4)
c.
Users will use the same app, and
will log in in the same manner
The home and login screens will
look the same, however their
functionality will be limited to
unlocking the door, choosing
"Auto," and adjusting their "Auto
Proximity Range" for the app's
"Auto" unlock feature.
1. From a position near the
device, click "Login" at the
top left of the home
screen.
2. Type "ADMIN" (case
sensitive) in the ID section.
3. Type the factory default
ADMIN passcode "12345"
as the passcode and click
"Confirm."

ENFORCER Bluetooth
®
Access Controllers
4SECO-LARM U.S.A., Inc.
SL
Access
Quick Setup (Continued):
Manage De ice and
Set De ice Settings
Below the function buttons are device settings
:
•Device name – give a descriptive name
•ADMIN passcode – change immediately
•ADMIN proximity card (except SK-B141-DQ)
•Door sensor – required for the door-propped-
open / door-forced-open alarm)
•utput mode (global) – timed relock, remain
unlocked, remain locked, or toggle
•Timed relock output time – 1~1,800 sec
•Number of wrong codes – Number that will
trigger a temporary device lockout
•Wrong code lockout time – how long the
device will remain locked out
•Tamper alarm – Vibration sensor
•Tamper vibration sensitivity – 3 levels
•Tamper alarm duration – 1~255 min
•Auto proximity range – for ADMIN app "Auto"
•Device time – automatically syncs with
ADMIN phone date and time
•Key tone - keypad sounds can be disabled
Four
function
buttons allow you to
:
•pen the user page to add or manage users
•View and download the audit trail
•Back up and restore device settings (also convenient for
replicating to another device).
Manage Users User Info Audit Trail
Add users by pressing the "Add"
button top right. Current users will
be listed in order of their addition
Edit users, add card/fob
(some
models), set access and override
global output mode
View last 1,000 events, save to
phone, email for archive
NOTICE:
The SEC
-
LARM policy is one of continual development and improvement. For that reason, SEC
-
LARM reserves the right to
change specifications without notice. SEC -LARM is also not responsible for misprints.
All trademarks are the property of
SEC -LARM U.S.A., Inc. or their respective owners. Copyright © 2020 SEC -LARM U.S.A., Inc. All rights reserved.
SECO-LARM
® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website:
www.seco
-
larm.com
Phone: (949) 261
-
2999 | (800) 662
-
0800
Email: sales@seco
-
larm.com
PIT
GW1
MQ_SKPR
-
Bxxx
-
xQ_200709.docx
Other ENFORCER IP Access Controllers manuals