ENFORCER SD-6176-SSQ User manual

Outdoor Piezoelectric
Request-to-Exit Pushbuttons
Manual
SD-6176-SSQ
Slimline plate, “TOUCH/EXIT”
SD-6176-SS1Q
Slimline plate, “EXIT/SALIDA”
SD-6176-SSVQ
Slimeline plate, manual override
SD-6276-SSQ
Single-gang plate, “TOUCH/EXIT”
SD-6276-SS1Q
Single-gang plate, “EXIT/SALIDA”
SD-6276-SSVQ
Single-gang plate, manual override
Piezoelectric push buttons for indoor
or outdoor use (IP65).
LED ring around button changes from
green to red or red to green when the
button is pressed.
Timed or toggle output.
Includes separate manual override
button in case power to piezoelectric
push button fails.
Relay rated 2A@30VDC with two
individually programmable outputs
(NO/NC).
Note: Products with model numbers that end with “Q” or that have a round green “Q” sticker are RoHS compliant.
ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
2SECO-LARM U.S.A., Inc
Specifications:
Operating voltage
12~24 VDC
Current drain
100mA@12VDC
Contact rating
2A@30VDC or 0.5A@125VAC
Ring LED
Colors reversible v a switch
Standby
Red
Active
Green
Output time
1~30 s, Toggle
IP rating
IP65
Operating temperature
32 ~158 F (0 ~70 C)
Plate material
Stainless steel
Weight
Single-Gang
3.5-oz (99g)
Single-Gang w/Manual
Override
4-oz (113g)
Slimline
2.6-oz (74g)
Slimline w/Manual
Override
3.1-oz (88g)
Parts List:
Piezoelectric push button........................... 1 x Mounting screws .................................. 2 x
Wires for manual override 1 ........................ 2 x Manual ................................................. 1 x
Overview:
SD-6176-SSVQ and SD-6276-SSVQ with Manual Override button shown, other models similar.
Installation:
1. Prepare wiring to provide 12~24 VDC power and connect devices to the relay outputs.
Note: The device includes one relay with two outputs. Outputs trigger simultaneously but can be
configured independently. To set the output modes, see Relay Output Modes on page 3.
2. Remove the plastic cover from the rear of the switch and carefully pierce the rubber grommet.
3. SD-6176-SSVQ and SD-6276-SSVQ: Wire the manual override button. See page 3.
4. Wire the switch according to the diagram on the right.
Connect (-) and (+) to a 12~24 VDC power source.
Connect other devices to Outputs 1 or 2.
5. Replace the plastic switch cover and screw the plate
onto the mounting surface.
1 SD-6176-SSVQ and SD-6276-SSVQ only.
Single-Gang
Slimline
41/2”
(114mm)
LED ring
Manual
override
button2
Piezo-
electric
pushbutton
15/8”(42mm)
23/4” (70mm)
15/8”(42mm)
Side View
Rear View
(Plastic switch
cover removed)
Relay adjust
Output mode
selection
Terminal blocks
Manual override
button2
Buzzer adjust
LED color
selection
Timer adjustment
Terminal Block
ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
SECO-LARM U.S.A., Inc 3
Wiring the Manual Override: SD-6176-SSVQ and SD-6276-SSVQ Only
Connect the manual override button with the included wires.
Notes
a. Remove the thin panel on the bottom of the plastic cover to allow wiring to pass through.
b. There is only one relay, wiring the button to either output will allow the other output to trigger simultaneously.
c. Do not connect the manual override button to more than one output.
d. When wiring for either N.O. or N.C., be sure to also set the Relay Output Mode to N.O., as described below.
If Relay Output Mode and override button wiring do not match, the product may not function as expected.
Configuring the Pushbutton:
1. Buzzer Output DEFAULT: ON
Use the buzzer output jumper JP3 to program the buzzer output.
Placing the jumper on the left turns buzzer output ON. Placing the
jumper on the right turns buzzer output OFF.
2. Relay Output Mode DEFAULT: N.O.
Outputs 1 and 2 can be set independently using jumpers
JP1 and JP2. Note: Both outputs trigger simultaneously.
Place the jumper on the right for N.O. operation and on the
left for N.C. operation.
3. LED Ring Colors DEFAULT: OFF
ON: LED is green while in standby, and turns red when triggered.
OFF: LED is red while in standby, and turns green when triggered.
4. Switch Output Type DEFAULT: Timer
TIMER: When set to TIMER, pressing the switch will trigger the relay for
the set time. Set the time using the trimpot as described above.
TOGGLE: When set to TOGGLE, pressing the switch will cause the
relay to trigger until the switch is pressed again.
5. Timer Adjustment DEFAULT: 1s
Output duration is adjustable 1~30 seconds. (Must be set to ‘Timer’in step 4)
Gently rotate the trimpot using a Philips head screwdriver.
Counterclockwise decreases the output time.
Clockwise increases the output time.
Wiring For N.O.:
Connect the two
wires between the
NO and COM
terminals of the
override button and
the Output 1 or 2
terminals on the
switch.
Wiring For N.C.:
Connect the two
wires between
the NC and COM
terminals of the
override button
and the Output 1
or 2 terminals on
the switch.
N.O.
COM
N.C.
COM
Manual
Override Button
ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
4SECO-LARM U.S.A., Inc
Sample Installation: Electromagnetic Lock (Fail-Safe) with Strobe Light
Also Available from SECO-LARM:
Electromagnetic
Locks
Request-to-Exit
Plates
No-Touch
Request-to-Exit
RF Wireless
Request-to-Exit
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship
while used in normal service for a period of one (1) year from the date of sale to the original consumer
customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the
unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by
or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and
workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be
limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be
liable for any special, collateral, incidental, or consequential personal or property damages of any kind
to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of
publication. However, the SECO-LARM policy is one of continual development and improvement. For
this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is
also not responsible for misprints or typographical errors.
Copyright ©2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced
or copied, in whole or in part, without the written permission of SECO-LARM.
SECO-LARM ®U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: [email protected]om
MiSD-6x73-SSxQ_1111.docx
PIHWK1
ENFORCER
Electromagnetic Lock
ENFORCER
LED Strobe Light

This manual suits for next models

5

Other ENFORCER IP Access Controllers manuals

ENFORCER SK-1131-SPQ User manual

ENFORCER

ENFORCER SK-1131-SPQ User manual

ENFORCER ENFORCER SK-B141-DQ User manual

ENFORCER

ENFORCER ENFORCER SK-B141-DQ User manual

Popular IP Access Controllers manuals by other brands

Soyal AR-888U manual

Soyal

Soyal AR-888U manual

Rosslare AYC-G60 Series Installation and programming manual

Rosslare

Rosslare AYC-G60 Series Installation and programming manual

Savi ST-656-I installation guide

Savi

Savi ST-656-I installation guide

Gallagher C300400 Installation notes

Gallagher

Gallagher C300400 Installation notes

Hafele WT 210 manual

Hafele

Hafele WT 210 manual

Isonas Pure IP Wiegand Reader Quick installation instructions

Isonas

Isonas Pure IP Wiegand Reader Quick installation instructions

Dahua DHI-DEE1010B-S2 user manual

Dahua

Dahua DHI-DEE1010B-S2 user manual

Pamex Kapture KA-WR1S User Manual & Implementation Guide

Pamex

Pamex Kapture KA-WR1S User Manual & Implementation Guide

Paxton ins-30093-EX quick start guide

Paxton

Paxton ins-30093-EX quick start guide

InVid Tech PAR-P2TEMPTABLET user manual

InVid Tech

InVid Tech PAR-P2TEMPTABLET user manual

ZKTeco Aurora T1 quick start guide

ZKTeco

ZKTeco Aurora T1 quick start guide

iDTRONIC ID LOCK 3000 manual

iDTRONIC

iDTRONIC ID LOCK 3000 manual

TECOM TS1067E manual

TECOM

TECOM TS1067E manual

Roger MC16 installation manual

Roger

Roger MC16 installation manual

Honeywell MPA2 Quick start up guide

Honeywell

Honeywell MPA2 Quick start up guide

FingerTec H3i user guide

FingerTec

FingerTec H3i user guide

Securi-Prod LK190 installation manual

Securi-Prod

Securi-Prod LK190 installation manual

Verkada AC12 install guide

Verkada

Verkada AC12 install guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.