ENFORCER IPV-PD88Q User manual

ENFORCER IP Surge Protector
4SECO-LARM U.S.A., Inc.
Wavy or ghost
video
image if connected
to an image processor (e.g., multiplexer
or DVR), but not if connected directly to
the monitor.
•Move the cable a ay from possible sources of interference.
•Replace the cable ith a ne cable.
•Ensure that the protected cable is as short as possible
Video image background flutters
bet een dark and light.
•Remove a local po er source, or adjust the monitor’s
brightness and contrast.
Video image is eak or faded.
•Reduce the cable length.
•Replace ith a higher-grade cable. Cat5 cable meets the
specifications in the manual. Cat6 cable allo s longer
range.
No video image. •Double-check that the cables ere connected properly.
•Run a continuity test on all ires in the cable.
Troubleshooting:
Also Available from SECO
-
LARM:
MilPV-PD88Q_1406.docx
PITSW4
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: .seco
-
larm.com
E-mail: sales@seco-larm.com
NOTICE
: The information and specifications printed in this manual are current at the time of publication. Ho ever, the SECO-
LARM policy is
one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications ithout notice.
SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2014 SECO-
LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in hole or in part, ithout the
ritten permission of SECO
-
LARM.
IMPORTANT
: Users and installers of this product are responsible for ensuring this product complies ith all national, state, and local
la s and statutes related to monitoring and recording audio and video signals. SECO-LARM ill not be held responsible for the use of this
product in violation of any current la s or statutes.
ARNING
:
Incorrect mounting hich leads to exposure to rain or moisture inside the enclosure could cause a dangerous electric shock,
damage the device, and void the arranty. Do not open the case of this device, as there are no field-serviceable components inside.
ARRANTY
: This SECO-LARM product is arranted against defects in material and orkmanship hile used in normal service for a
period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or
replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration,
improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating
properly as a result of causes other than defects in material and orkmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any
kind to the purchaser or anyone else.
Video Surge Protector
VS-1V12BQ
PoE Surge Protector
IPV-P188Q
HD
-
SDI Surge Protector
VS-1V22AQ
IPV-PD88Q
Manual
•
Helps prevent damage to sensitive computer or CCTV equipment
such as cameras, monitors, digital video recorders, video splitters,
PCs, servers or net orking hubs
•Intercepts repeated surges and spikes that could damage net ork
equipment
•Installs on Cat5e/6 4-pair UTP cable ith RJ45 jacks
•Passive operation – no external po er required
•Includes a grounding post
IP Surge Protector

ENFORCER IP Surge Protector
2SECO-LARM U.S.A., Inc.
Overview:
Specifications:
Introduction:
The ENFORCER IP Surge
Protector is a passive device that helps protect sensitive net orking
equipment from po er surges. The device can be deployed in ne installations or added to
existing ones.
The IPV-PD88Q IP Surge Protector should be installed bet een devices connected by Cat5e/6
4-pair UTP cable to protect against surges that could damage computer or video equipment.
NOTE
: For the best protection, installing t o surge protectors is recommended: one at each end of
the net ork cable.
Band idth
Up to
1GHz
Maximum input
7.6
Vp
-
p
Insertion loss
<0.2dB
Return loss
16dB@
100
Ω
Frequency response
Up to 3
dB
@113MHz
Insulation resistance
10,000
M
Ω
Maximum surge voltage
4 k
V
Discharging current
100A
Surge life
300
surges@
100A
Surge protection time
1ns
Surge resistance
0
Ω
Signal passing
capability
Breakdo n voltage
7.6V
Clamping voltage
10.0V
Connector
In
RJ45
Out
RJ45
Impedance
42
Ω
Dimensions
3
7
/
16
”x2
5
/
8
”x1
1
/
16
” (87x67x27 mm)
Weight
4.4
-
oz (
126g)
Material
Aluminum
Operating temperature
-
40
°~1
94° F (
-
40
°~
90° C)
Unprotected End
Protected
End
Top View
3
7
/
16
”
(87mm)
2
5
/
8
” (67mm)
2
5
/
8
” (67mm)
Mounting
Tab
To
Cat5e/6
Cable
To Protected
Device
Ground
1
1
/
16
”
(27mm)
ENFORCER IP Surge Protector
SECO-LARM U.S.A., Inc. 3
1x
IP Surge Protector
4x
Mounting Scre s
1x
12”
(
305mm
) Ground Cable
4x
Plastic Wall Anchors
Protecting Multiple Devices:
1.
Mount the IP Surge Protector as close as possible to the device to be protected.
2. Detach the Cat5e/6 cable from the device to be protected and attach to the “Unprotected” port
of the IP Surge Protector.
3. Attach an additional short Cat5e/6 cable bet een the device to be protected and the
“Protected” port of the IP Surge Protector. This cable should be as short as possible to connect
the t o devices. In addition the protected cables should not cross unprotected cables.
4. Use supplied ground cable to connect the ground (GND) terminal to earth ground. The system
should use a single ground point and the protected device should be isolated from ground.
Protecting a Single Device:
Installation:
NOTE
: These
instructions assume that
2
IP
devices
have
already
been
connected together.
Parts List:
Shortest
Possible
Cat5e/6 cable
Shortest
Possible
Cat5e/6 cable
Protected
End
Protected
End
IP S itch
(Protected)
IP Surge
Protector
Unprotected
End To ground
Original Cat5e/6 cable
To ground
IP Surge
Protector
IP Camera
(Protected)
Unprotected End
Shortest
Possible
Cat5e/6 cable
IP Surge
Protector
To ground
IP S itch
(Not Protected)
IP
Camera
(Protected)
Cat5e/6 cable
Protected End
1.
Mount the t o IP Surge Protectors as close as possible to each device to be protected.
2. Detach the Cat5e/6 cable from each device to be protected (such as an IP s itch
or IP camera)
and attach to the “Unprotected” port on its respective IP Surge Protector.
3. Using additional short Cat5e/6 cables, connect each device to be protected to the “Protected”
end of its respective IP Surge Protector. These cables should be as short as possible to
connect each device to its respective surge protector. In addition the protected cables should
not cross unprotected cables.
4. Use supplied ground cable to connect each IP Surge Protector’s ground (GND) terminal to
earth ground. The system should use a single ground point and the protected device should be
isolated from ground.
This manual suits for next models