enphase Q-CONN-3P-10F User manual

QUICK INSTALL GUIDE (Models Q-CONN-3P-10F and Q-CONN-3P-10M)
Install the Enphase Three-Phase
Field Wireable Connectors
Corporate Headquarters Contact Information
Enphase Energy Inc.
47281 Bayside Parkway
Fremont, CA 94538 USA
© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase
logo, Enphase Field Wireable Connector, and other trademarks or
service names are the trademarks of Enphase Energy, Inc. Data
subject to change. Rev02-11-12-2021.
PREPARATION
Check that you have Enphase Field Wireable Q Connectors for three-phase Q Cable
as needed for your installation. Both female and male connectors are sold in packs
of ten:
• Field Wireable Q connector for three-phase (female):
(Q-CONN-3P-10F)
• Field Wireable Q connector for three-phase (male):
(Q-CONN-3P-10M)
Make sure you have the following recommended tools:
• Screwdriver blade width 3.5mm, PH1 Screwdriver
• 30mm wrench
Use Enphase Field Wireable Q Connectors with three-phase Enphase Q Cable or eld cable to:
• Easily connect three-phase Q Cables without complex wiring
• Use a mated pair of connectors to end-feed the branch circuit with an AC connection
• Use mated pairs of connectors to connect with a remote part of the array
FEMALE CONNECTOR PARTS
MALE CONNECTOR PARTS
PARTS
*WARNING: Risk of equipment failure. Do not mix
male and female connector parts when assem-
bling connectors.
Technical Data
Degree of Protection IP66/IP68 (2m, 24h)
Nominal Current
(Observe derating, see
graph below)
Conductor cross section IEC/EN61984
6 mm235 A
4 mm232 A
2.5 mm224 A
Nominal Voltage 690 V
Rated Surge Voltage 6 kV
Pollution Degree 3
Operating temperature -40°C to +110°C
Material PPE
Enphase Customer Support: http://enphase.com/global/contact
1. Cable gland
2. Seal
3. Housing
4. Contact carriers
1. Cable gland
2. Seal
3. Housing
4. Contact carriers
1
2
3
4
N
3
4
3
2
1
IEC/EN61984

B) Connect the conductors to the contact carrier. Match the assign-
ment according to the label on the contact carrier.
* WARNING: Ensure that the correct connection for Line, Neutral,
Earth match according to the label on the contact carrier. In case
of mismatch, phase balance of system will be affected.
NOTE: For exible wires, we recommend using ferrules acc. to
DIN 46228 that are crimped with jointing clamp.
C) Torque the contact carrier screws to 1 Nm.
D) Push the contact carrier into the housing until it snaps in audibly.
E) Tighten the cable gland to a torque of 6.5 Nm.
* WARNING: Observe the permitted bending radius during installation.
The degree of protection might fail if the bend radius is exceeded.
A) Prepare the cable:
• Push the cable gland over the cable.
• If there are multiple seals, select a seal that ts your cable
diameter.
• Push the housing with seal over the cable.
• Strip 50mm from the cable.
• Shorten conductors N, L1, L2, and L3 by 8 mm, but keep PE (prot.
earth) at 50mm.
• Strip 12mm from the conductors.
ASSEMBLY
Follow the steps to assemble Enphase Field Wireable Q Connectors for three-phase connections.
FEMALE MALE
Loosening the cable
• Loosen the cable gland.
• Use the screwdriver to release the contact carrier on both sides.
• Pull the contact carrier from the housing.
• Loosen the screws on the contact carrier, and loosen the wires.
B
AB
A
B
B
30
4.5 Nm
rmin 4 xd
d
4.5 Nm
30
CLICK !
CLICK !
N
3
Click
Click
1 Nm
N
3
1 Nm
N
3
8
12
50
8
12
50

Enphase Customer Support: http://enphase.com/global/contact
- FIELD WIREABLE Q CONNECTORS - THREE-PHASE
Safety Symbols
+DANGER: This indicates a hazardous situation, which if
not avoided, will result in death or serious injury.
*WARNING: This indicates a situation where failure to
follow instructions may be a safety hazard or cause
equipment malfunction. Use extreme caution and follow
instructions carefully.
;WARNING: Risk of burn. Failure to follow instructions may
result in burn injury.
✓NOTE: This indicates information particularly important
for optimal system operation.
SAFETY
IMPORTANT SAFETY INSTRUCTIONS.
SAVE THIS INFORMATION.
Follow all safety and assembly instructions when installing En-
phase Field Wireable Q Connectors.
Safety Instructions
+DANGER: Risk of electric shock. Do not use Enphase
equipment in a manner not specied by the manufacturer.
Doing so may cause death or injury to persons, or dam-
age to equipment.
+DANGER: Risk of electric shock. Be aware that installation
of this equipment includes risk of electric shock. Do not
use without rst removing AC power from the Enphase
System. Disconnect the power coming from the photovol-
taics before servicing or installing.
+DANGER: Risk of electric shock. Risk of re. Before mak-
ing any connections verify that the circuit breakers are in
the off position. Double check all wiring before applying
power.
+DANGER: Risk of electric shock. Risk of re. Only use
electrical system components approved for wet locations,
including but not limited to conduit ttings.
+DANGER: Risk of electric shock. Risk of re. Only qualied
personnel should install, troubleshoot, or replace the
Enphase Field Wireable Q Connector.
+DANGER: Risk of electric shock. Improper use of the Field
Wireable Q Connector or its components may result in a
shock, re or explosion. To reduce these risks, disconnect
all wiring before attempting any maintenance.
+DANGER: Risk of electric shock. Risk of re. Ensure that all
AC and DC wiring is correct and that none of the AC wires
are pinched, shorted, or damaged.
+DANGER: Risk of electric shock. Risk of re. Do not
attempt to repair or alter the Enphase Field Wireable Q
Connector.
+DANGER: Risk of electric shock. Risk of re. Make sure the
conductors are not damaged. If the exposed wires are
damaged, the system may not function properly.
*WARNING: Risk of equipment damage. Enphase male and
female connectors must only be mated with the matching
male/female connector.
*WARNING: Risk of equipment damage. This product is
intended for operation with a maximum operating temper-
ature of 110ºC.
*WARNING: When installing the cabling, secure any loose
cable to minimize tripping hazard.
*WARNING: Before installing or using the Enphase Field
Wireable Q Connector, read all instructions and cautionary
markings in the technical description, on the Enphase
System, and on the photovoltaic (PV) equipment.
*WARNING: Never plug in or disconnect the connectors
under load. The connectors are not suitable for interrupt-
ing the current.
*WARNING: Without earthing connection.
✓NOTE: Using unapproved attachments or accessories
may result in damage or injury.
✓NOTE: When looping the Enphase Q Cable, do not form
loops smaller than 12 cm in diameter.
✓NOTE: Perform all electrical installations in accordance
with all applicable local electrical codes.
✓NOTE: To ensure optimal reliability and to meet warranty
requirements, install the Enphase Field Wireable Q Con-
nectors according to the instructions in this guide.
✓NOTE: Protection against lightning and resulting voltage
surge must be in accordance with local standards.
✓NOTE: The connector is considered to be in compliance
only when assembled in the manner specied by these
assembly instructions.
✓NOTE: For exible wires, we recommend using ferrules
acc. to DIN 46228 that are crimped with jointing clamp.
✓NOTE: Cable used with Enphase Field Wireable Q Connec-
tors must meet the following requirements:
• Min/max outer insulation diameter (including the
clear second insulator): 8mm / 21mm
• Wire size: 2.5mm2 to 6mm2
DISCONNECT (if needed)
To disconnect Enphase three-phase Field Wireable Q Connectors,
release the two connectors by pressing down the snap with a screw-
driver. You can then separate the connectors.
* WARNING: Never plug in or disconnect the connectors under
load. The connectors are not suitable for interrupting the current.
Enphase Article Number Enphase Product SKU Type Designation
150-00094 Q-CONN-3P-10F PRC 5-FC-FS6...
150-00093 Q-CONN-3P-10M PRC 5-FC-MS6...
This manual suits for next models
1
Other enphase Cables And Connectors manuals

enphase
enphase EP200G-LITKIT User manual

enphase
enphase Engage Cable User manual

enphase
enphase CT-200-SOLID User manual

enphase
enphase ET17-240-40 User manual

enphase
enphase Q Series User manual

enphase
enphase QD-CONN-10F User manual

enphase
enphase Q-CONN-3P-10F User manual

enphase
enphase Ensemble COMMS-KIT-01 User manual

enphase
enphase IQ Series User manual