Table of Contents
Important Safety Information .......................................................................................................................................... 5
Read this First.................................................................................................................................................. 5
Product Labels ................................................................................................................................................. 5
Safety and Advisory Symbols........................................................................................................................... 5
IQ 7 Microinverter Safety Instructions.............................................................................................................. 5
PV Rapid Shutdown Equipment (PVRSE) ....................................................................................................... 7
The Enphase IQ System................................................................................................................................................. 8
How the Enphase IQ Series Micros Work........................................................................................................ 9
System Monitoring ....................................................................................................................................... 9
Optimal Reliability ........................................................................................................................................ 9
Ease of Design............................................................................................................................................. 9
Planning for Microinverter Installation........................................................................................................................... 10
Compatibility................................................................................................................................................... 10
Grounding Considerations.............................................................................................................................. 10
Branch Circuit Capacity.................................................................................................................................. 11
Utility Service Requirements.......................................................................................................................... 11
Wire Lengths and Voltage Rise...................................................................................................................... 11
Lightning and Surge Suppression.................................................................................................................. 12
Parts and Tools Required............................................................................................................................................. 13
Enphase Equipment................................................................................................................................... 13
Other Items................................................................................................................................................ 13
Enphase Microinverter Installation................................................................................................................................ 14
Step 1: Position the Enphase Q Cable........................................................................................................... 15
Step 2: Position the Junction Box................................................................................................................... 15
Step 3: Mount the Microinverters ................................................................................................................... 16
Step 4: Create an Installation Map................................................................................................................. 17
Step 5: Manage the Cabling........................................................................................................................... 18
Step 6: Connect the Microinverters................................................................................................................ 18
Step 7: Terminate the Unused End of the Cable............................................................................................ 19
Step 8: Complete Installation of Junction Box................................................................................................ 20
Step 9: Connect the PV Modules................................................................................................................... 20
Step 10: Energize the System........................................................................................................................ 21
Set Up and Activate Monitoring...................................................................................................................... 21
Troubleshooting............................................................................................................................................................ 22
Status LED Indications and Error Reporting .................................................................................................. 22
LED Operation........................................................................................................................................... 22
DC Resistance Low –Power Off Condition ............................................................................................... 22
Other Faults ............................................................................................................................................... 23
Troubleshoot an Inoperable Microinverter...................................................................................................... 24
Disconnect a Microinverter............................................................................................................................. 25
Install a Replacement Microinverter............................................................................................................... 26
Ordering Replacement Parts.......................................................................................................................... 28
Enphase Q Cable Planning and Ordering...................................................................................................... 28
Connector Spacing Options ........................................................................................................................... 28
Cabling Options.............................................................................................................................................. 28
Enphase Q Cable Accessories....................................................................................................................... 29
Technical Data.............................................................................................................................................................. 30
Technical Considerations............................................................................................................................... 30
Specifications................................................................................................................................................. 31
IQ7-60-2-US Microinverter Specifications.................................................................................................. 31
IQ7PLUS-72-2-US Microinverter Specifications ........................................................................................ 34
IQ7X-96-2-US Microinverter Specifications ............................................................................................... 36