ENSIM SENSORS DX-ECAS Series User manual

KULLANIM
KILAVUZU
CAPASITIVE LEVEL SWITCH
DX-ECAS
Model :
Model : 07-2019-003
Information in this manual is reviewed and completely reliable. Responsibility is not assumed due to any typing error.
Products in this manual are available only for information purpose and they may be changed without notice.
DX-ECAS 101 / 102 / 103 / 107
DX-ECAS 202 / 203 / 204 / 205 / 20S
DX-ECAS 301 / 304 / 305 / 30D
DX-ECAS 408A
Models :
1
1783
Important Notes:
Used Symbols :
Table of Contents :
1. General Information ...........................................................................................................................................2
2. Installation ..................................................................................................................................................6
3. Failure Detection ..............................................................................................................................................19
4. Disassembly of Instrument ..................................................................................................................................19
5. Service ......................................................................................................................................................19
6. Recalibration...............................................................................................................................19
7. Repair.......................................................................................................................................................19
8. Disposal ..................................................................................................................................................19
9. Terms of Warranty .....................................................................................................................................19
10. Terms of Return ..............19
Please read this manual carefully before installation of the Capasitive level switch. User is responsible for
accidents and losses arising from failure to comply with the warnings in this manual.
In the event that Capasitive level switch. is broken, take measures in order to prevent accidents and losses which
can occur in its system.
There is not any fuse and circuit breaker on the instrument; they should have been added to the system
by the user.
This manual should be stored in an easily accessible place for subsequent use.
Do not operate the system before making assembly in compliance with the assembly chart related
to the instrument.
Do not make any modification on the instrument and do not try to repair it. Reparation should be made
by authorized service personnel.
The instrument's useful life, determined and announced by the ministry, is 10 years.
Products which do not contain label and serial number are considered to be excluded from the warranty scope.
: Caution : Note : Disposal
2
1. General Information :
1.1. Material Acceptance
DX-ECAS level switch is a capacitive level sensor for level measurement of conductive liquid, nonconductive liquid, granulated materials with
solid particles, adhesive and acid/basic liquids. When a material comes between electrode rod and tank wall, a capacitance change occurs and
when this change exceed adjustment threshold, contact output is delivered. Designed for difficult process conditions. Refrigerated models
can be manufactured for high temperature and pressure conditions. Calibrations of triggering point and relay operation range can be performed
by the user under workplace conditions. It can be connected horizontally or vertically.
1.2. Information about Areas of Use
Liquid tanks, food machines, cooling liquid tanks, shipping, glycol tanks, brine,
waste water tanks.
Oil tanks, CO2 liquid tanks, high temperature tanks, non-conductive liquids.
Grain stores, cement, sand feed, flour, milk powder, organic and plastic granule.
Sticky hot and high viscosity liquid, acid and chemical liquids.
Ambient Conditions: Relative Humidity: 0-98 %RH Ambient temperature: 60C (It is not used under -20 C)
1.3. Working Principle
Capacitance definition, assuming two parallel conductive plates are used;
Advantages:
Optionally high temperature-resistant
design.
Easy assembly and sensitivity
adjustment.
No need to clean.
Not affected by foam, liquid splash and
probe coating.
Can be mounted upside.
d
C
R
Metal Tank
S
Isolation
C: Capacity , Farad
S: Surface Area , m2
d: Distance , m
eo.er.S
d
C=
Capacity
Distance
Impedance
Distance
However, there are scarcely any sensor type which this definition can be pratically utilized.
Above Formula can no longer bi reliable especially when residual areas increase due to large
distance (d) (which is usually the case). Thus, measuring impedance for distance measurements
give more accurate results than capacitance measurement.
e
Impedance definition Z = R + jL + ( jC )-1
e
R is defined as real component and represent ambient conductivity.
3
Environment Pressure / Temperature Chart
-20 40 80 2000
16
25
Pprocess (bar)
Tprocess (°C)
Process Pressure / Temperature Chart
-40 150
With Cooling Apparatus
2.p.eo.er
In (b/a)
Impedance is calculated by this definition
C=
jLw second component is defined as inductive reactance. This component is present even if we perform capacitive
measurement. However we neglect this. Since we evaluate results based on electrostatic properties of the environment,
no error will occur. Resulting impedance definition is Z= R + (jC )-1.
e
Measurement is made by charge transfer in our capacitive sensors. Total impedance is defined as Z = V / I.
I (current) I = Q/t
Q (Coulomb)
T (sec)
Capacitive reactance we desire to measure is (jC )-1. Meaning that charge and impedance have the same phase.
To summarize, charge transferred to medium is directly proportional with capacitive reactance.
For sensors manufactured as coaxial;
a: Central electrode radius
b: Outer screen radius
L: length
e
e
Excitation applied between 10KHz250KHz based on length for all our models. ( =2xpxf)
Linearity error that may be caused by conductivity component (R) effect is prevented by electronic
circuit design and mechanical design. Reduced to a level lower than 1ppm, acceptable as zero.
40
80
0-40 100 200150 Tprocess (°C)
T Ambient (°C)
With Cooling Apparatus
4
1.4. Technical Specifications and Material Knowledge
1.5.Application Examples
ll 1/2 G Ex d llC Tx*1 Ga/Gb For Gas
ll 1/2 D Ex (ta/tb)*3 lllC Tx*2 For Dust
Have a look at the temperature class chart.
Certification
*
1 NONC x5 A/250VAC Relay
Opt. Peek, CeramicPTFE, PFA
Aluminum Injection - AlSi12Fe (Std)
Black (RAL.9005)
er
9-36 VDC
-1...25 bar (Depending on the model)
304 St.St. Opt. 316 St.St.
(-)40/(+)150°C (Depending on the model)
200°C with cooling apparatus
230°C with PEEK isolation
400°C with ceramic isolation
1,6
With LED-Power and Contact LED
Max. 1 W
Terminal
EMC, Low Voltage
285 g. for DX-ECAS 101
(-)20...(+)60°C
IP 66
Max. 40 NM
Max. 500V
Supply
Signal Output
Working Pressure
Min.Di-Electric Constant
Measurable Metarial
Connection Material
Display
Power Consumption
Protection Class(EN60529)
Test
Max. Tensile Force
Weight
Isolation Material
Housing Material
Working Temperature
Ambient Temperature
Electrical Connection
Isolation
Conductive liquids, refrigerants
Non-conductive liquids
Solids particulate materials
Adhesive and acid/basic liquids
AC/DC Relay
PLC
Light
Hooter
Max. 200°C
(With
cooling apparatus)
Solids
Particulate
Material
Adhesive
and
Acid / Basic Liquid
Conductive
Liquid
Low
Conductive
Liquid
1.8. Target Group
This operating manual has been prepared for qualified technical personnel.
1.9. Güvenlik Notlarý
Aþaðýdaki notlar operatör ve çevresinde oluþabilecek tehlikelerden kaçýnmak için
dikkate alýnmalýdýr.
Bu cihazýn kurulumu, kullanýmý ve bakýmý yalnýzca kullaným kýlavuzunu okumuþ ve iþ güvenliði konusunda bilgili kiþilerce yapýlmalýdýr!
Ýþ güvenliði, kaza önleme yönetmelikleri ve ulusal kurulum standartlarýna uyulmalýdýr.
Ürün yalnýzca belirtilen spesifikasyonlar dahilinde kullanýlmalýdýr!
Cihazý yalnýzca basýnç olmadýðýnda monte edebilirsiniz!
1.6. Label Information
Std. Package
1.7. Package and package contents
Please check whether you have taken delivery
of below listed content completely or not and check
its conformity with criterions in your order:
*Capasitive Level Switch
*This operating manual
5
:
:
:
:
:
Type : DX-ECAS 101-9-250-1-008-11-01-67-02-00/0
Power Supply
Output
Process Temp.
T (Ambient)
Serial Number
Level Switch
24VDC +/- %10
1 x 5A / 250VAC NO / NC
-40 / +150°C
-20...+60°C
IE18040002-0001
www.ensim.com.tr
MADE IN TURKIYE
1783
LONCA A.Þ. Ferhatpaþa Mah.Gazipaþa Cad. No:104A
34888 Ataþehir - ÝSTANBUL / TÜRKÝYE
Type B20x
www.ensim.com.tr
16A 240 VAC 50 / 60 Hz IE18030095-0014
S.No:
Model
Serial Number
Working Conditions
If the ATEX certificate metal label is damaged,
you can contact the manufacturer with the serial number.
Manufacturer Name Manufacturer Address
Note :
IE 18 04 0002 - 0001
DO NOT OPEN WHEN ENERGIZED
KEEP TIGHT WHEN CIRCUIT ALIVE
M3
Supply
Output
Working Temperature
TSE 18ATEX0099
ll 1/2 G Ex d llC Tx*1 Ga/Gb
ll 1/2 D Ex (ta/tb)*3 lllC Tx*2
Notified
Date Sign
Explosive Protection AreaProduct Name
Producer Website
Warning Symbols
Manufacturer
Brand
Product
Label
Metal
Label
Ground
Label
Model
Explosive
Protection Area
Serial
Number
Features
ATEX Classes
Product
Number
System
Number
Month
Year
Work
Order
6
1.10. Certifications and Approvals
:It shows that, product meets required conditions of EU with CE stamp
and stipulate that product passed quality assessment stages
TS EN 60079 - 0 : 2013
TS EN 60079 - 1 : 2014
TS EN 60079 - 31 : 2014
ATEX (2014 / 34 / AB) :
LVD (2014 / 35 / AB) :TS EN 61010 - 1 : 2012
TS 3033 EN 60529 : 1997
TS EN 61326 - 1 : 2013EMC (2014 / 108 / AT) :
Note: All the features and tests on this decument has manufactured with DX-ELS models at LONCA Inc.
1.10. Safety Ýnstructions (ATEX)
Safety instructions should be read and applied to the end.
-The following notes must be taken into attention to protect the operator and the enviroment from possible hazards.
-The device setup and maintenance of this device must be done by knowledgeable persons who has read the instructions and is familiar with
the safety at work.
-Ýt should be checked by the users that the products are fitted suitable to the zone maps.
-Work safety,must be observe by accident prevention regulations and national installation standards.
-The product should be used within the specification presented guideline.
-You can only mount the device when there is no presure.
-These safety instructions are protected in terms of 1 / 2 D and 1 / 1 G category for DX-ELS coded series and is compatible with
TSE 18ATEX0099 and CE certificate.
-The Label should be used in appropriate environments.
-Because the enviroment is max. 60 C you should choose a suitable cable for use.
-Do not over tighten the cable gland in order not to affect the IP protection class.
-Make sure the cable entry and plug is tightened right.
-Ground connection must be done properly and checked without energizing.
-Before starting use make sure the lid is fully closed and the set screw is tightened.
-DX-ELS models are metal protected.Ýt is Compatible with different supply voltages specified in the catalog.
- The metal enclosure must be in the 2D or 2G zone. The pipe and float section must be located in the 1D and 1G zone.
-Max. working temperature,max. Surface temperature can change depending on the model, Please read the document carefully before using.
-During the mounting it should be checked that there is no mechanical stress or deformation in the tank wall.When this happens, the sensor should
not be energized without the necessary correction measures.
-Check that the presure in the tank hasnt exceed the presure shown in the catalog.
-The mounting sensor must be mount properly in the tank filling system.In case it is not suitable, the sensor must be protected and the in-tank
apparatus must be protected.
-The sensor is designed to withstand the chemical effects of the materials.Check the suitability of different materials.
-The Sensors are in suitable storage conditions and protected from dust and damp.
-Device repairs should only be done at the manufacturer Lonca Inc.
-Protect the device from friction and cleaning should be done without water.
-In case of improper circuit conditions, the main energy must be completely disconnected and safety measures should be taken without replacing
the temperature circuit breaker with its backup.Changes should be made in a safe area.
7
1.12. ATEX Marking Sample Description
II 1/2 D Ex ta/tb IIIC T4 IP66
II 1/2 G Ex d IIC T4 IP66
Dust
Explosive Protection
Area
Equipment Group
Equipment Category
Explosive Atmosphere
Explosive Protection
Protection Type
Dust Type
Temperature Class
(Max. Surface Temperature)
Housing Protection Class
Gas
Explosive Atmosphere
Protection Type
Temperature Class
(Max. Surface Temperature)
Housign Protection Class
Equipment Group
Equipment Category
Explosive Protection
Gass Type
Explosive Protection
Area
8
L
Trigger Point
Feeling Area
Relay adjustable
operating (%50)
2. Installation :
2.1. General Notes :
The device installation is in 2014 / 34 / EU criteria to ensure the safety of atmosphere and people from explosions, must only be done by staff who
knows the safeguards.
Do not apply force to the instrument during the installation!
Do not use the Capacitive Level Switch with a greater pressure than recommended pressure.
Do not forget that instrument is precise, carry it carefully and prevent not to be damaged.
It should be guaranteed that there are not any magnetic particles.
The Max. working pesure should not be exceeded.
2.2. General Installation Stages
*Remove Capacitive Level Switch from the box carefully
*Check whether gasket is appropriate for fluid or not. If is not appropriate, contact with the producer.
*Then, apply below mentioned explanations according to structure of the design.
2.3. Special Notes
*Please ensure that there is no mechanical stress on the shaft following installation. Such case will cause slipping in thecharacteristic curve.
*Capacitive Level Switch must be placed upright or horizontal.
*Allocate valve certainly in the process connection while instrument is used.
*Allocate blowdown valve under bottom flange for blowdown.
*If instrument is mounted outside and if there is any danger of lightning or
excessive pressure, take preventive measures by taking necessary measures.
*In the operating conditions, Capacitive Level Switch may be hot according
to situation of fluid, in this case, do not touch the indicator, otherwise your skin is damaged.
*The grounding product must be done properly. (can be done outside or in housing)
2.4. Installation For Mechanical Connections
*Use appropriate O-Ring or gasket for tightness.
*Ensure that its surface is clean and smooth.
*Assemble the instrument manually.
*Connect the contacts as shown in the figure.
(For G1" max. 20 Nm, G 1 1/4, for G 1 1/2 max. 30Nm)
9
2.5. Electrical Installation
Make the electrical connection of the instrument according to details on its label, table and cable figures in this manual
9-36 VDC
NA
NK
Com
+-
2.6. Mechanical Parts
Insulated Probe
Cover
Elektronic Unit
Housing
Coaxial Probe
Cable Gland
Connection
Record
Chain
RlyLED: Relay active during normal operation; means operation continues during
calibration. Flashes continuously in normal operation mode if relay is
active and blinks in calibration mode. It is red colored.
PwrLED: Means there is no sensor failure during normal operation, and means
desired measurement values are saved in memory during calibration.
Operates by flashing. If light is continuous, it indicates failure. It is gren colored.
CAL - S Button: Used to acquire High Level-span-value during calibration.
CAL - Z Button: Used to acquire Low Level-zero-value during calibration.
TST Button: During normal operation, functions as Relay Test; during calibration,
performs saving to nonvolatile memory of Zero-Span, the values previously acquired
by S and Z button, function.
LVL - C Pot: Adjusts relay triggering point between Zero-Span values.
LVL - F Pot: Performs as fine tuning for triggering point. Adjustment field is equal
to +/- 5% of the point adjusted by C Pot (total 10%).
DIF Pot: Adjusts Release level of the relay activated by C/F Pot.
Highest adjustable value is equal to half (50%) of the operation region specified by
Z and S. Meaning that, when DIF Pot is at 100% and relay is pulled, the level to
release it shall be reduced as half of the total scale.
*
*
*
*
*
*
*
*
Indification and Calibtarion :
Note : It has been produced according to IPC A 600 class 2
conditions and tested with 100 % E-test. Moreover,
HASL (non-lead) surface test has been applied.
10
2.7. Mechanic Connections :
Flanged
b
D1
D
Hex
B
b
Thread
Clamp
b
D
Dairy d
d1
D
A
Material : 304 Stainless Steel
Welded manufacturing
Opens - Closes Hinged
To Protect Against external conditions.
Protection Case :
Housing :
MATERIAL PROTECTION
CLASS
TEMPERATURE
(oC)
TYPE
B20x
Aluminium
IP 66 -40...+200
SIZE
a x b (mm)
132 x 104
ORDER
CODE
25
Cooling :
27 Hex
PFA
L
68
For 200°C
1/2BSP
B20x
Alüminium
b
a
Ta
Factory Area
(Safe)
ZONE 21 / 1
or
ZONE 22 / 2
Tp
Process Side
(Explosive Enviroment)
ZONE 20 / 0
or
ZONE 21 / 1
or
ZONE 22 / 2
Order
Code
Dimension
B
Hex
[mm]
Stem Lenght
b [mm]
3/8BSP
1/2BSP
3/4BSP
1BSP
1 1/4BSP
1 1/2BSP
2BSP
50
50
50
50
50
60
70
20
14
14
23
23
23
23
(ISO228-1)
003
004
005
006
007
008
009
PN 16 D (mm)
DN25
DN32
DN50
DN80
DN100
165
140
165
200
220
85
100
125
160
180
D1 (mm) b (mm)
16
16
18
20
20
(ISO1092-1)Order
Code
103
104
106
108
109
PN 40 D (mm)
DN25
DN32
DN50
DN80
DN100
115
140
165
200
235
85
100
125
160
190
(ISO1092-1)
D1 (mm) b (mm)
18
20
20
20
24
Order
Code
303
304
306
308
309
150 LBS D (mm)
DN50
DN65
DN80
DN100
152,4
177,8
190,5
228,6
121
139,7
152,4
157,2
(ANSI B16.5)
D1 (mm) b (mm)
19
22,2
23,8
23,8
Order
Code
606
607
608
609
Dimension Dia. b
(mm)
DN32
DN50
DN65
50,5
64
91
15
17
17
(ISO2852)
D (mm)
851
852
853
Order
Code
D (mm)
DN40
DN50
DN100
56
68
121
48
61
114
d1 (mm) A (mm)
13
14
20
Dimension
DN40
DN50
DN100
Dimension
870
871
872
Order
Code
11
CONDUCTIVE LIQUIDS
Fully Insulated Rope
Conductive Tank
DX-ECAS 107
(-)1...+25 bar
(-)40...+150°C
L=250mm.(Std) Max. 1 m.
Fully Insulated Coaxial Probe
Insulated Tank
DX-ECAS 103
(-)1...+25 bar
(-)40...+150°C
Fully Insulated Rope
Conductive Tank
(-)1...+25 bar
(-)40...+150°C
L=1mt.(Std) Max. 16 m.
DX-ECAS 107
PFA
3/4BSP
50 Hex
L
St. St.
80
St. St.
Ø35
St. St.
1 1/2BSP
60 Hex
PFA
L
80
200
St. St.
St. St.
2BSP
70 Hex
Ø40
PFA
L
80
Aluminium Aluminium Aluminium
(-)1...+25 bar
(-)40...+150°C
DX-ECAS 101
L=250mm.(Std) Max. 4 m.
DX-ECAS 102
L=250mm.(Std) Max. 4 m.
(-)1...+25 bar
(-)40...+150°C
50 Hex
PFA
L
1/2BSP
Aluminium
70 Hex
L
2BSP
PFA
St. St.
Aluminium
L=1mt.(Std) Max. 32 m.
Fully Insulated Probe
Conductive Tank
Fully Insulated Coaxial Probe
Insulated Tank
2.8. Sample Models
12
LOW CONDUCTIVE LIQUIDS
L=1mt.(Std) Max. 16 m.
(-)1...+25 bar
(-)40...+150°C
DX-ECAS 204 DX-ECAS 204
L=1mt.(Std) Max. 32 m.
(-)1...+25 bar
(-)40...+150°C
DX-ECAS 205
L=250mm.(Std) Max. 6 m.
(-)1...+25 bar
(-)40...+150°C
Sample Models:
St. St.
1 1/2BSP
Ø35
St. St.
St. St.
60 Hex 50 Hex 1BSP
Ø12
Aluminium
St. St.
Ø40
Aluminium Aluminium
2BSP
70 Hex
80
L
L
PTFE
St. St.
200
St. St.
St. St.
L
DX-ECAS 202
L=250mm.(Std) Max. 4 m.
(-)1...+25 bar
(-)40...+150°C
DX-ECAS 203
L=250mm.(Std) Max. 1 m.
(-)1...+25 bar
(-)40...+150°C
50 Hex
L
3/4BSP
St. St.
70 Hex
L
2BSP
St. St.
Aluminium Aluminium
DX-ECAS 20S
Ýzolesiz Koaksiyel Prob
Ýletken / Yalýtkan Tank
L=250mm.(Std)
Max. 4 m.
(-)1...+25 bar
(-)40...+400°C
60 Hex
L
1 1/2BSP
St. St.
Aluminium
320
Ø38
Partly Insulated Coaxial Probe
Conductive / Insulating Tank
Partly Insulated Probe
Conductive Tank
Partly Insulated Rope
Conductive Tank
Partly Insulated Rope
Conductive Tank
Partly Insulated Coaxial Probe
Conductive / Insulating Tank
13
PTFE
Ø21
80
L
DX-ECAS 301
Compled Insulated Probe
Conductive Tank
L=250mm.(Std) Max. 1 m.
(-)1...+25 bar
(-)40...+150°C
SOLID PARTICLE LIQUIDS
50 Hex 1BSP
DX-ECAS 305
Partly Insulated Probe
Conductive Tank
L=250mm.(Std) Max. 6 m.
(-)1...+25 bar
(-)40...+150°C
St. St.
Antistatic
For Materials
DX-ECAS 304
L=1000mm.(Std) Max. 16 m.
(-)1...+25 bar
(-)40...+150°C
L=380mm.(Std) Max. 1 m.
(-)1...+25 bar
(-)40...+200°C
DX-ECAS 30D
Double Partly Insulated Probe
Insulating Tank
41 Hex
Ø21
1BSP
PTFE
PTFE
Ø12
80508050
L
Sample Models:
Aluminium
Aluminium
8050
L
50 Hex 1BSP
St. St.
PTFE
Aluminium
Ø12
St. St.
1 1/2BSP
80
Ø35
St. St.
St. St.
L
60 Hex
Aluminium
8050
Partly Insulated Rope
Conductive Tank
14
ADHESIVE AND ACID / BASIC LIQUIDS
Sample Models:
ECAS 408A
Double Probe (Single Fully Insulated)
Conductive / Insulating Tank
L=250mm.(Std) Max. 6 m.
(-)1...+25 bar
(-)40...+150°C
L
50 Hex 1BSP
St. St.
PTFE
St. St.
Aluminium
ECAS 408A
Double Probe (Single Fully Insulated)
Conductive / Insulating Tank
L=250mm.(Std) Max. 4 m.
(-)1...+25 bar
(-)40...+150°C
L
50 Hex 1BSP
PFA
St. St.
Aluminium
St. St.
L=250mm.(Std) Max. 1 m.
(-)1...+25 bar
(-)40...+150°C
ECAS 408A
Double Probe (Single Fully Insulated)
Conductive / Insulating Tank
PFAPFA
1BSP
St.St.
50 Hex
L
Aluminium
15
Temperature Class Table
STD.
MODEL
DX-ECAS
Without opening the cover
standby time 30min.
Working temperature (-)40...(+)150°C
30°C
40°C
50°C
60°C
150°C
150°C
150°C
150°C
60°C
67°C
75°C
88°C
(-) 20° C < T Ambient < (+) 30° C...(+) 60° C Working Temperature :(-) 40...(+) 150°C
DX-ECAS (Metal)
Thermal Protection Insurance is 105 °C
200°C
200°C
200°C
200°C
(-) 20° C < T Ambient < (+) 30° C...(+) 60° C Working Temperature :(-) 20...(+) 200°C
DX-ECAS (Metal + With Cooling)
30°C
40°C
50°C
60°C
42°C
46°C
56°C
68°C
T6
T6
T6
T6
T6
T6
T6
T5
2.9. Maximum Surface Temperature
T Ambient
MAX. AMBIENT TEMPERATURE
ZONE 21 / 1
T Process
MAX. PROCESS TEMPERATURE
ZONE 20 / 0
T Surface
MAX. SURFACE TEMPERATURE TEMPERATURE CLASS
T Ambient
MAX. AMBIENT TEMPERATURE
ZONE 21 / 1
T Process
MAX. PROCESS TEMPERATURE
ZONE 20 / 0
T Surface
MAX. SURFACE TEMPERATURE TEMPERATURE CLASS
2.10. Part Names
16
Cover Seal
Chain
Cover
Electronic Cart
Body
Product Label
Grounding Label
Body Set screw
Grounding Screw
Grounding Internal Bracket
Stopper
Cable Record
Metal Label
Body Seal
Grounding Screw
Grounding Outer Bracket
Connection Thread
Cover Set screw
Probe Isolation
Probe
O-Ring
Probe Tightening Nut
Probe Tightening Spring
PFA Pipe
17
2.11. Order Form
7
SAMPLE
Relay Output (NO/NC) (5A).............................11
8
Special........................................................x
HOUSING
9
INSULATION MATERIAL
10
CONNECTION MATERIAL
11
316 Stainless Steel.....................................02
Brass............................................................41
PVC.............................................................61
Polypropylene...................................................62
Delrin.................................................63
PVDF........................................................64
PBT.........................................................65
PTFE..................................................66
Special....................................................x
OPTIONAL
No...................................................................../ 0
13
Wall Apparatus......................................./ W
Special....................................................../ x
ELECTRICAL CONNECTION
With Terminal....................................................00
12
Special........................................................x
PROCESS TEMPERATURE
150°C Standard ..............................................0
200°C with Cooling Apparatus .........................1 (-)196°C For Cyrogenic Tank ...................2
230°C with Peek Insulated ...................3
400°C with Seramic Insulated ..................4
6
STEM LENGHT
5
CERTIFICATE
No........................................................................0
PROBE TYPE (MAX. LENGHT)
Conductive Liquids..............................................1
Low Conductive Liquids .................................2
MODEL DX-ECAS
SolidsParticulate Materials.......................3
Adhesive and Acid/Basic Liquids............4
(EN10204-3-1) Material Certification........1
........................................................................mm
PROBE DIAMETER (Ø)
........................................................................mm Special ...................................................... x
CONNECTION
OUTPUT
Special........................................................x
Aluminium Housing, B20x................................25
DX-ECAS 101 - 10 - 300- 0 - 006 - 11 - 25 - 66 - 02 - 00 / 0
For Cond. Liquid, L=300mm, 1 BSP, Relay Output, Aluminium Housing , Ø10 Probe
Thread (ISO 228-1) Clamp (ISO 2852) ISO Flange (1092-1) ASA Flange (B16.5) Special Flange
1/2 BSP..................04
3/4 BSP.................05
1 BSP.................06
1 1/2 BSP .............08
2 BSP.................09
1/2 NPT.........12
3/4 NPT.........13
DN25 - PN16 ... 21
DN50 - PN16 ... 23 DN25 - PN40 ... 26
DN32 - PN40 ... 27
DN50 - PN40 ... 28
DN80 - PN40 ... 29
DN100 - PN16 ... 30
Ø70 Flanged....71
Special...............x
DN50 - 150lb ... 41
DN80 - 150lb ... 43
DN100 - 150lb ... 44
Single Probe - Insulated (Max 4m) ............... 1
Single Probe - Coaxial (max 4 m) Ø38 ........ 2
Single Probe - Thin Coaxial (max 1 m), Ø21 ... 3
Rope -
Partly Insulated
(Max 32 m)...............4
Single Probe -
Partly Insulated
(Max 6 m) .... 5
Single Probe - High Temperature (Max 4m) ... 6
Rope - Fully Insulated (0 ... 32mt) ................... 7
Double Probe - Single Fully Insulated (Max 4m) .......................... 8A
Ceramic Partly Insulated Probe (Max 4 m) .......................... S
Double Fully Insulated Probe (Max 4 m) ................................... D
Special ................................................................................. x
PBT..................................................................65
PTFE.................................................................66
PFA............................................................67
PEEK..........................................................68
Polyamide..........................................69
Ceramic.............................................70
Rubber........................................81
FKM....................................................84
Special........................................................x
Please consider sample models when coding!.. (Lined spaces defines the standard code)
18
2.12. WARNING !!!
Please pay attention to following matters in order to operate your flow switch properly.
When connecting the switch to the tank
Connect with 20 degree angle.
Switch from 30 cm each other
do not connect close
Please keep away from magnetic materials
like iron board ; otherwise the
characteristics might be affected
Please do not dip cables
potting into liquids,otherwise
instulation problem may cause.
Do not fasten switch reversely ,
otherwise its characteristics
might be changed.
Please do not drop ,
otherwise the characteristics
might be changed.
Vibration might be caused instability.
Do not remove the plastic parts
of the bottom of the switch body ,
do not loosen.
Do not pull the cable strongly,
otherwise the characteristics
might be changed.
Do not fasten switch reversely ,
otherwise its characteristics
might be changed.
Do not connect the switch in reverse.
Their characteristics may vary.
Excess current , to be drawn as
a result of direct connection to motor,
may burn relay of switch
19
Your device must be repair only at an outhorized serviced.
3. Failure Delection
If you find an error, try to eliminate it by using this table or send the instrument to our service address for repair.
The instrument should be repaired only by authorized service! Serial number shall be indicated to the authorized service center.
4. Disassembly of Instrument
Instrument should be disassembled while feeding and pressure is not available!
5. Service
6. Re-Calibration
During long period usage of capacitive level switch, there might be deviations on measurements. In those cases, recalibration is recomended. Re-calibration could be made by your
technical staff or you could send to manufacturer company. According to IEC 60017, ex proof devices must be go through detailed inspection every 3 year from purchase
date.Respobsibility of inspections are belong to the user ( IEC: International Electrotechnical Commission)
7. Repair  Manufacturer Address
If irreparable breakdowns occur, the instrument should be sent to us for repair purpose. Before this, the instrument should be cleaned carefully and packaged
so as not to be broken. Furthermore, you should also add a detailed explanation which describes the breakdown while instrument is sent. If your instrument
contacts with harmful substances, decontamination report should be also sent additionally. In the event that instrument does not have any decontamination
report or our service department has doubts about instrument, repair process will not start until an acceptable report is sent.
8. Disposal
The instrument should be disposed according to 2002/96/EC and 2003/108/EC European Directives (waste electrical and electronic instruments).
Waste electrical and electronic equipment should not be mixed with domestic wastes!
If the instrument has contacted with harmful substances, special attention should be paid for its disposal!
9. Terms of Warranty
The instrument has warranty legally for 24 months after delivery date. Warranty demands are not accepted in case of inappropriate operation, damage on the
instrument or any modification on the instrument.
10. Terms of Return
In the return of materials, user should send an open list related to damage or problem, malfunction of the material to be returned or its operation in the different
modification, with the instrument. If it is required to return the material, used in the dangerous, corrosive or toxic fluid, in this case, used part should be cleaned
very carefully. Security of personnel should be ensured. All products to be returned should be sent to our company address, which
we have stated.
The instrument does not require maintenance. If it is desired, residue accumulated inside should be blown according to kind of fluid and instrument can be cleaned
with soft cleaning solutions. Measures should be taken during the disassembly.
If the instrument contacts with hazardous substances, necessary measures should be taken for decontamination!
Service -Manufacturer Company Name and Address:
LONCA PAZ. MAK. SAN. TÝC. A.Þ. Ferhatpaþa Mah. Gazipaþa Cad. No: 104A Ataþehir - ÝSTANBUL - TÜRKÝYE
Tel:+90 216 50 50 555 Faks:+90 216 515 45 84 E-Mail: [email protected] Web: www.ensim.com.tr
Power Led does not work.
* Supply voltage may not be work.
*Power led might be faulty.
* Electronic card might be faulty due to supply.
* The supply voltage must be checked.
* Please apply to service.
* Please apply to service.
Relay does not output * The applied process may not be suitable for the probe
* Grounding connection might be poor or disconnected
* The low voltage might be supply.
* Grounding might be done correctly.
* The applied process may not be suitable for the probe.
* The Teflon coating on the product probe might be
damaged.
* Grounding might be done correctly.
Relay provides continuous output.
Non-Calibration
* Trimpot might be deformed.
* The applied process may not be suitable for the probe.
* Grounding might be done correctly.
* Proper probe structure and product detection must be perfomed.
* The grounding connection check.
* Supply must be checked.
* Please check grounding line.
* Proper probe structure and product detection must be perfomed.
* Protection of external coatings of probes.
* Please check grounding line.
* Please apply to service.
* Proper probe structure and product detection must be perfomed.
* Please check grounding line.
Breakdown Probable cause Failure detection\correction

This manual suits for next models

14

Other ENSIM SENSORS Switch manuals

ENSIM SENSORS ELP User manual

ENSIM SENSORS

ENSIM SENSORS ELP User manual

ENSIM SENSORS ELS User manual

ENSIM SENSORS

ENSIM SENSORS ELS User manual

ENSIM SENSORS ELM Series User manual

ENSIM SENSORS

ENSIM SENSORS ELM Series User manual

ENSIM SENSORS ELT User manual

ENSIM SENSORS

ENSIM SENSORS ELT User manual

ENSIM SENSORS ELP Series User manual

ENSIM SENSORS

ENSIM SENSORS ELP Series User manual

ENSIM SENSORS EFS User manual

ENSIM SENSORS

ENSIM SENSORS EFS User manual

ENSIM SENSORS DX-ELT User manual

ENSIM SENSORS

ENSIM SENSORS DX-ELT User manual

ENSIM SENSORS ELC 21d User manual

ENSIM SENSORS

ENSIM SENSORS ELC 21d User manual

ENSIM SENSORS ISS 04 User manual

ENSIM SENSORS

ENSIM SENSORS ISS 04 User manual

ENSIM SENSORS ECAS 101 User manual

ENSIM SENSORS

ENSIM SENSORS ECAS 101 User manual

ENSIM SENSORS DX-ELF 101 User manual

ENSIM SENSORS

ENSIM SENSORS DX-ELF 101 User manual

ENSIM SENSORS DX-ELS User manual

ENSIM SENSORS

ENSIM SENSORS DX-ELS User manual

ENSIM SENSORS DX-ELS Series User manual

ENSIM SENSORS

ENSIM SENSORS DX-ELS Series User manual

ENSIM SENSORS DX-ELB 11 User manual

ENSIM SENSORS

ENSIM SENSORS DX-ELB 11 User manual

Popular Switch manuals by other brands

ETI MLBS S instruction manual

ETI

ETI MLBS S instruction manual

Omron D4CC - datasheet

Omron

Omron D4CC - datasheet

Gefen EXT-3GSDI-441 user manual

Gefen

Gefen EXT-3GSDI-441 user manual

Dell Networking S4148-ON Setup guide

Dell Networking

Dell Networking S4148-ON Setup guide

Divus Heartbeat quick start guide

Divus

Divus Heartbeat quick start guide

ACT AC7900 Quick install guide

ACT

ACT AC7900 Quick install guide

ESPRIT Elite Voltario T30 user manual

ESPRIT

ESPRIT Elite Voltario T30 user manual

Cisco SG 300-10 quick start guide

Cisco

Cisco SG 300-10 quick start guide

Nortel DMS-100 Series Maintenance manual

Nortel

Nortel DMS-100 Series Maintenance manual

NTI SE-15V-xx-L Installation and operation manual

NTI

NTI SE-15V-xx-L Installation and operation manual

Velux INTEGRA KLI 310 instructions

Velux

Velux INTEGRA KLI 310 instructions

Chipset Communication USB-DS22H Quick installation guide

Chipset Communication

Chipset Communication USB-DS22H Quick installation guide

GeoVision GV-POE0811 manual

GeoVision

GeoVision GV-POE0811 manual

Diodes PI5USB30213AXEA user manual

Diodes

Diodes PI5USB30213AXEA user manual

SmartVM PS/2 IP-KVM switch user manual

SmartVM

SmartVM PS/2 IP-KVM switch user manual

AAVARA PB9000W user guide

AAVARA

AAVARA PB9000W user guide

Spectrex Incite Fire SharpEye FS-1200 user guide

Spectrex

Spectrex Incite Fire SharpEye FS-1200 user guide

Castell KSS quick start guide

Castell

Castell KSS quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.