Enterasys VHIM100-S2MFX 100Base FX-SC Fiber
Switch Module provides fiber links from the Switch (or
connected stack) to remote sites. It contains two
100BASE-FX ports that can be connected to sites up to
2 km (1.24 miles) away with fiber cable.
Fiber Port LEDs
Port LEDs for the module are located on the front
panel of the switch. These LEDs provide port status for
“at-a-glance” network monitoring. The LEDs used may
vary for different switch models. The following table
details the indicator functions provided by the
VH-2402S:
Expansion Module LEDs
LEDs Condition Status
Link On A valid link has been established on
the port.
Flashing Port has been manually disabled, or
partitioned by the system due to
excessive errors.
Status On A module is installed in this slot.
Activity Flashing Traffic is passing through the port.
INSTALLING THE MODULE
CAUTION: The Uplink is designed to be used with the
Vertical Horizon Series products only. Do not try to
install this module in any other units.
Be sure to install the VHIM100-S2MFX module into the
appropriate slot on the switch. Refer to the product
Installation Guide for detailed information.
Equipment Checklist
After unpacking the VHIM100-S2MFX Switch Module,
check the contents of the box to be sure you’ve
received the following items:
•One VHIM100-S2MFX Switch Module
•This document
Handling the Module
CAUTION: The VHIM100-S2MFX Switch Module can
easily be damaged by electrostatic discharge.
To prevent electrostatic damage, observe the following
guidelines:
•Do not remove the module from its packaging until
you are ready to install it.
•Do not touch any of the module’s pins, connectors
or components.
•Hold the module only by its edges or front panel.
•Wear an anti-static wristband connected to a
suitable earth ground whenever handling the
module.
•Store or transport this module only in appropriate
anti-static packaging.
Instructions
CAUTION: The switch must be powered off before
installing or replacing any module.
1. Power off the switch: Disconnect the AC power
cord from the switch. If a redundant power unit
(RPU) is present, disconnect its DC cable
connection to the switch.
2. Remove network cables: If you are replacing a
module, remove the cable attached to the port on
the module.
3. Loosen the screws on the installed module or
slot faceplate: Using your fingers or a flathead
screwdriver, turn the screws securing the module
(or faceplate on the slot) in a counter-clockwise
direction until they are free of the chassis. Be sure
not to completely remove the screws from the
module or faceplate.
4. Remove the installed module or faceplate:
Firmly pull on the screws until the module is free of
the switch. Carefully slide the module straight out
of the slot.
Keep the original faceplate for future use. If you
should remove the module, replace the faceplate to
prevent dust and debris from entering the unit and
to maintain proper air flow.
5. Insert the new module into the switch: Holding
the new module with the text on the front panel
upright, carefully slide the module into the switch
slot and press gently until it snaps into place. Be
sure the new module’s front panel is flush with the
switch panel.
6. Secure the new module: Secure the new module
in place by screwing the attached screws clockwise
into the switch’s chassis. Tighten them enough to
secure the module, but not so tight as to prevent
them from being unscrewed by hand.
7. Connect the network cable: Connect fiber cable
to the port on the newly installed module. See
“Connectivity Guidelines”in this guide for further
information.
8. Power on the switch: Reconnect the previously
removed power sources to the switch. The switch’s
front-panel LEDs should indicate the status of the
new connection. Check the LED indicators for the
fiber port to ensure that they are operating
correctly. Refer to the table of LEDs in this guide
for a description of the LED indications. If the
module does not respond, see “Troubleshooting”
below.
More details concerning connection options and
network applications can be found in the product’s User
Guide. Information on the module’s configuration
options can be found in the Management Guide that is
included with the base unit.
TROUBLESHOOTING
If you experience any problems with the module, check
the following items before contacting Enterasys
Technical Support:
•Ensure the switch with the Fiber Switch Module is
powered up.
•Ensure that the device attached to the module is
powered up and operating correctly.
•Ensure that the module is properly seated in the
slot.
•Verify that the attached device is configured to
match the communication mode used by the
module (half or full duplex).
•Check the connectors on both ends of the cable to
be sure they are properly engaged. When attaching
fiber cable to an SC-type port, be sure the plug
clicks into place to ensure that it is properly seated.
•If you are using fiber optic cable with an ST-type
connector in conjunction with an SC-ST port
converter*, try switching the TX and RX connectors.
*You may use an SC-ST converter to attach fiber
cable with an ST-type connector to the SC-type
port on the Switch Module.
•Be sure the fiber terminators are clean. You can
clean the cable plugs by wiping them gently with a
clean tissue or cotton ball moistened with a little
ethanol. Dirty fiber terminators on fiber optic cables
will impair the quality of the light transmitted through
the cable.
SAFETY WARNING
Before installing or removing the VHIM100-S2MFX, first disconnect the
switch from the main power supply. For full safety instructions, please refer
to the user guide that accompanies the switch.
Warning:
Optical Safety for
Fiber Optic Modules
Never look at the transmit LED through a magnifying device while it is
powered on. Never look directly at the fiber TX port and fiber cable ends
when they are powered on.
Avertissment:
Ports pour fibres optiques -
sécurité sur le plan optique
Ne regardez jamais le voyant (DEL) d’émission en utilisant un dispositif
d’agrandissement, tant qu’il est sous tension. Ne regardez jamais
directement le port TX (Transmission) à fibres optiques et les embouts de
câbles à fibres optiques tant qu’ils sont sous tension.
Warnhinweis:
Faseroptikanschlüsse -
Optische Sicherheit
Niemals mit einem Vergrößerungsgerät ein Übertragungs-LED betrachten,
während dieses eingeschaltet ist. Niemals direkt auf den Faser-TX-
Anschluß und auf die Faserkabelenden schauen, während diese
eingeschaltet sind.
SPECIFICATIONS
Ports
2 100BASE-FX
Network Interface
SC connector, 1300 nm long-wavelength transceiver
62.5/125 or 50/125 micron multimode fiber cable
Switch Method
Store-and-forward
Queue Buffer
128 Kbytes
Size
4.82 x 3.57 x 1.08 in.
(12.25 x 90.70.5 x 2.74 cm)
Power Consumption
10.6W maximum
Temperature
Operating: 32°to 122°F (0°to 50°C)
Storage: -40°to 158°F (-40°to 70°C)
Humidity
Operating: 5% to 95%
Compliances
CE Mark
Emissions
FCC Class A
EN55022 (CISPR 22) Class A
VCCI Class A
C-Tick
Immunity
IEC 1000-4-2/3/4/6
Standards
802.3u Fast Ethernet
ISO/IEC 8802-3
CONNECTIVITY GUIDELINES
snoitacificepSdnasepyTelbaC
elbaCepyThtgneL.xaMrotcennoC
T-esaB01PTUmho-0015,4,3.taC).tf823(m00154-JR
XT-esaB001PTUmho-0015.taC).tf823(m00154-JR
XF-esaB001norcim521/5.26ro521/05
rebifedomitlumeroc
xelpudflaH).tf4.153,1(m214TSroCS
xelpudlluF)selim42.1(mk2TSroCS
rebifedom-elgnis521/01)tf404,61(mk5TSroCS
XS-esaB0001norcim521/5.26ro521/05
rebifedomitlumeroc
gniwollofehteeS
elbat
TSroCS
XL-esaB0001FMSroFMMgniwollofehteeS
elbat
TSroCS
snoitacificepSrebiFXS-esaB0001
retemaiDrebiF htdiwdnaBladoM egnaR
norcim521/5.26 mk/zHM061)m022-2(tf227-7
mk/zHM002)m572-2(tf209-7
norcim521/05 mk/zHM004)m005-2(tf1461-7
mk/zHM005)m055-2(tf5081-7
snoitacificepSrebiFXL-esaB0001
retemaiDrebiF htdiwdnaBladoM egnaR
FMM521/5.26 mk/zHM005)tf5081-7(m055-2
FMM521/05 mk/zHM004)tf5081-7(m055-2
mk/zHM005)tf5081-7(m055-2
FMS521/01A/N)tf404,61-7(mk5-m2
retemaiDkrowteNtenrehtEtsaFmumixaM
epyTretaepeR
rebmuNdna
riaPdetsiwT
XT-ESAB001
rebiF/riaPdetsiwT
XFdnaXT-ESAB001
IssalC1)tf656(m002)tf4.558(m8.062
IIssalC1)tf656(m002)tf6.2101(m8.803
IIssalC2)tf4.276(m502)tf1.907(m2.612
Note: Network diameter is defined as the wire distance between
two end stations in the same collision domain.
VHIM100-S2MFX
100BASE FX-SC
FIBER SWITCH MODULE
QUICK INSTALLATION GUIDE
9033637
E102000-R01
150527-102
NOTICE
Enterasys Networks reserves the right to make changes in specifications and other
information contained in this document without prior notice. The reader should in
all cases consult Enterasys Networks to determine whether any such changes have
been made.
The hardware, firmware, or software described in this manual is subject to change
without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY
INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES
WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS)
ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION
CONTAINED IN IT, EVEN IF NETERASYS NETWORKS HAS BEEN
ADVISED OF, KNOWN, OR SHOULD HAVE KNOWN, THE POSSIBILITY OF
SUCH DAMAGES.
2000 by Enterasys Networks, Inc., P.O. Box 5005, Rochester, NH 03866-5005
All Rights Reserved
Printed in Taiwan, R.O.C.
Order Number: 9033637 October 2000
Neterasys, Neterasys Networks, and Vertical Horizon are trademarks or registered
trademarks of Enterasys Networks, Inc.
Microsoft, Windows, Windows 95, Windows 98, and Windows NT are either
trademarks or registered trademarks of Microsoft Corporation.
Netscape and Netscape Navigator are trademarks of Netscape Communications
Corporation.
All other product names mentioned in this manual may be trademarks or registered
trademarks of their respective companies.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment uses,
generates, and can radiate radio frequency energy and if not installed in accordance
with the operator’s manual, may cause harmful interference to radio communica-
tions. Operation of this equipment in a residential area is likely to cause interfer-
ence in which case the user will be required to correct the interference at his own
expense.
WARNING: Changes or modifications made to this device which are not expressly
approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
INDUSTRY CANADA NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions
from digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les
limites applicables aux appareils numériques de la class A prescrites dans le
Règlement sur le brouillage radioélectrique édicté par le ministère des Communica-
tions du Canada.
VCCI NOTICE
EC CONFORMANCE DECLARATION
European contact: Enterasys Networks Limited
Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG13 2PZ, England
This information technology product complies with ISO/IEC Guide 22 and
EN45014. It conforms to the following specifications:
EN55022(1988)/CISPR-22(1985) Class A
EN50082-1: IEC 1000-4-2, 3, 4, 6
This information technology product complies with the requirements of the
Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and
carries the CE Mark accordingly.
Only qualified personnel should perform installation
procedures.

Other Enterasys Switch manuals

Enterasys Matrix E5 5H153-50-G User manual

Enterasys

Enterasys Matrix E5 5H153-50-G User manual

Enterasys Enterasys RoamAbout RBT-1002-EU How to use

Enterasys

Enterasys Enterasys RoamAbout RBT-1002-EU How to use

Enterasys Matrix 7H4385-49 Manual

Enterasys

Enterasys Matrix 7H4385-49 Manual

Enterasys Enterasys Matrix DFE-Gold Series User manual

Enterasys

Enterasys Enterasys Matrix DFE-Gold Series User manual

Enterasys Mid-Span Power Hub BL-6000ENT User manual

Enterasys

Enterasys Mid-Span Power Hub BL-6000ENT User manual

Enterasys SSR-GTX32-04 User manual

Enterasys

Enterasys SSR-GTX32-04 User manual

Enterasys Matrix 7G4280-19 Manual

Enterasys

Enterasys Matrix 7G4280-19 Manual

Enterasys 08H20G4-24 Manual

Enterasys

Enterasys 08H20G4-24 Manual

Enterasys RoamAbout RBT-4102-EU Instruction Manual

Enterasys

Enterasys RoamAbout RBT-4102-EU Instruction Manual

Enterasys Matrix DFE-Gold 4G4202-60 Manual

Enterasys

Enterasys Matrix DFE-Gold 4G4202-60 Manual

Enterasys Matrix 2G4072-52 User manual

Enterasys

Enterasys Matrix 2G4072-52 User manual

Enterasys 2H252-25R Operation manual

Enterasys

Enterasys 2H252-25R Operation manual

Enterasys Matrix-V V2H124-24 Manual

Enterasys

Enterasys Matrix-V V2H124-24 Manual

Enterasys SecureStack C2 C2G124-24 Manual

Enterasys

Enterasys SecureStack C2 C2G124-24 Manual

Enterasys Matrix 7H4202-72 Manual

Enterasys

Enterasys Matrix 7H4202-72 Manual

Enterasys Vertical Horizon VHIM1000-S1TX User manual

Enterasys

Enterasys Vertical Horizon VHIM1000-S1TX User manual

Enterasys SecureStack C2 C2G170-24 User manual

Enterasys

Enterasys SecureStack C2 C2G170-24 User manual

Enterasys Mid-Span Power Hub User manual

Enterasys

Enterasys Mid-Span Power Hub User manual

Enterasys SecureStack C3 C3G124-24 User manual

Enterasys

Enterasys SecureStack C3 C3G124-24 User manual

Enterasys Enterasys SecureStack B2 B2G124-24 Manual

Enterasys

Enterasys Enterasys SecureStack B2 B2G124-24 Manual

Enterasys Vertical Horizon VHIM100-S1SFX 100BASE FX-SC User manual

Enterasys

Enterasys Vertical Horizon VHIM100-S1SFX 100BASE FX-SC User manual

Enterasys I Series Manual

Enterasys

Enterasys I Series Manual

Enterasys Vertical Horizon VH-2402S2 Manual

Enterasys

Enterasys Vertical Horizon VH-2402S2 Manual

Enterasys RoamAbout RBT-8200 User manual

Enterasys

Enterasys RoamAbout RBT-8200 User manual

Popular Switch manuals by other brands

Kramer VS-21H-IR user manual

Kramer

Kramer VS-21H-IR user manual

H3C S9500 Series Operation manual

H3C

H3C S9500 Series Operation manual

evertz 7700 Series manual

evertz

evertz 7700 Series manual

Raisecom Gazelle S1020i-LI user manual

Raisecom

Raisecom Gazelle S1020i-LI user manual

QSFPTEK S5600-48T4X quick start guide

QSFPTEK

QSFPTEK S5600-48T4X quick start guide

Liebert Static Transfer Switch 2 Installation, operation & maintenance manual

Liebert

Liebert Static Transfer Switch 2 Installation, operation & maintenance manual

British General WPDD Technical data

British General

British General WPDD Technical data

HP 2600-PWR Series Guide

HP

HP 2600-PWR Series Guide

Allegion LCN 8310-805C manual

Allegion

Allegion LCN 8310-805C manual

Magnadyne Video Switching Center VCS-6 installation instructions

Magnadyne

Magnadyne Video Switching Center VCS-6 installation instructions

Broadrack Mars 8 user manual

Broadrack

Broadrack Mars 8 user manual

Ceiec Electric PMC-1220E user manual

Ceiec Electric

Ceiec Electric PMC-1220E user manual

DeviceWell HDS6112 user manual

DeviceWell

DeviceWell HDS6112 user manual

ANTAIRA LNX-0501G-SFP user manual

ANTAIRA

ANTAIRA LNX-0501G-SFP user manual

TRENDnet TPE-224WS - Web Smart PoE Switch user guide

TRENDnet

TRENDnet TPE-224WS - Web Smart PoE Switch user guide

Fore Systems ES-2810 user guide

Fore Systems

Fore Systems ES-2810 user guide

Parallax ATS 5070 FI Operator's guide

Parallax

Parallax ATS 5070 FI Operator's guide

Wolpertech 4045 manual

Wolpertech

Wolpertech 4045 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.