SVT innovations SVT-2 Series User manual

SVT-2 Outdoor Station B
User Manual
SVT-2 Outdoor Station B
2W12120
Please read this user manual prior to installing the system, and keep it well for future use.
Dan Smith

CONTENTS
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Specification ...................................................................................................... 2
4.Mounting .............................................................................................................. 2
4.1 Mounting Without Rain Guard ....................................................................... 2
4.2 Mounting With Rain Guard ............................................................................ 3
4.3 External Motion Detection............................................................................. 4
5.System Wiring and Connections ......................................................................... 4
5.1 Basic Connection........................................................................................... 4
5.2 Electric Lock Connection ............................................................................... 5
5.2.1 Door Lock Controlled with Internal Power ............................................ 5
5.2.2 Door Lock Controlled with Dry Contact ................................................ 5
5.3 Multi Outdoor Stations Connection ............................................................... 6
5.4 Multi Indoor Monitors Connection .................................................................. 7
5.4.1 Basic IN-OUT Wiring Mode ................................................................. 7
5.4.2 With DBC-4 Wiring Mode .................................................................... 8
6.Setup Instructions ........................................................................................... 9 - 14
6.3 Power Supply................................................................................................. 15
7.Cable Requirements ............................................................................................ 16

-1-
1.Parts and Functions
2.Terminal Descriptions
BUS
PL
S1+ S2+ S-
1 2
3
Lock Control
Jumper
PIR Motion
Detector Connect
Port
+12
V
GN
D
PI
R
L1L2
PL
S+S-
Main Connect
Port
[11] [10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rain cover
[11] Mounting hook
[12] Connection port
[13] Screw hole

-2-
3.Specification
4.Mounting
4.1 Mounting Without Rain Guard
145 - 165 cm
1
2
1 2 3 4
Lock Control Jumper: To select the lock type.
Motion Detector Connect Port: To connect external PIR motion detector.
Main Connect Port: To connect the bus line and the electronic locks.
•L1,L2: Connect to the bus line, no polarity.
•PL: External lock power input, connect to the power positive(power +).
•S+: Lock power(+) output.
•S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).
Power supply: Power
consumption:
Camera lens:
Lock Power supply:
Number of relay circuits:
Mounting:
Working temperature:
Protection:
Material:
Wiring:
Dimension:
DC 24V
Standby 0.8W; Working 3W
Color CMOS, 520TVL
1/4" camera, 115º wide angle
12Vdc, 280mA(Internal Power);
2(the second lock need external power to support)
Surface wall-mount
-4ºF ~ +131ºF | -20ºC ~ +55ºC
IP54
Zinc alloy panel
2 wires, non-polarity
176(H)×90(W)×27(D)mm(surface mounted)

-3-
4.2 Mounting With Rain Guard
12
Rainy cover
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
Main unit
3 4 5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
1.. Connect the cable correctly .
2.. Dr l holes in the wall to match the size of screw stoppers,then attach the rainy cover and
main unit to the wall, and the distance between the top of main unit and rain cover should be not
less than 3mm.
3.. Install the name plat
4. Attach the front panel to the main unit.
5.. Use the special screwdriver and the screws to fix the pan

-4-
4.3 External Motion Detection
5.1 Basic Connection
5.System Wiring and Connections
The door station is equipped with a terminal to
connect external motion detector.
If the external motion detector is connected
to the system,following functions will be effec-
tive:
If detect someone passing by, the door station
can be activated operation to unlock or turn
on light.
12V
Motion
detector
GND
PIR
BUS(IM) BUS(DS)
-
+
L1 L2 PL S+ S-
ID=0
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
SVT-2 PC6
AC~
100~240VAC

-5-
5.2 Electric Lock Connection
5.2.1 Door Lock Controlled with Internal Power
5.2.2 Door Lock Controlled with Dry Contact
1.Electronic lock of Power-on-to-unlock
type should be used.
2.The door lock is limited to 12V, and hold-
ing current must be less than 250mA.
3.The jumper should be placed on position
2 and 3 before connecting.
4.The door lock control is not timed from
Exit Button(EB).
5.The Unlock Mode must be set to 0 (by
default).
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
1.The external power supply must be used according to the lock.
2.The inside relay contact is restricted to
230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before
connecting.
4.Setup the Unlock Mode according to
different lock types.
•Power-on-to-unlock type:Unlock
Mode=0 (by default)
•Power-off-to-unlock type:Unlock
Mode=1
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
*A SVT-2 RCL lock connector is needed for 2nd lock connection.

-6-
5.3 Multiple Outdoor Stations Connection
100~240VAC
SVT-2 DBC4
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
SVT-2 PC6
AC~
ID=0
1st door station
ID=1
2nd door station
ID=2
3rd door station
ID=3
4th door station
L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S-
To monitors
•Max.4 outdoor stations can be connected to the system.
•Ensure to set the correct address for each outdoor station. Refer to Page X for more details
about the address setting of outdoor stations.

-7-
5.4.1 Basic IN-OUT Wiring Mode
5.4 Multiple Indoor Monitors Connection
ID=0
Optional modules
BUS(IM) BUS(DS)
SVT-2 PC6
AC~
100~240VAC
SCU TPS

-8-
5.4.2 Using SVT-2 DBC-4 distributor device - Wiring Mode
DBC4A1
A B C D
SVT-2 RCL SVT-2 DBC4
Impedance
OFF ON
switch
Code=1 Code=2
Code=3 Code=4
ID=0
Optional modules
SVT-2 BDU
85~260AC
SVT-2
DPS
SVT-2
PS5

-9-
Setup Instructions
6.
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
This section explains the settings of each
function,please refer to the following table:
To perform the settings for the function
you want,you should move away the metal
front panel. Please refer to the sketch
map.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sounding of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2Setting door station
calling mode Standard/Group calling mode Standard calling mode
3 Setting camera resolution High/Low High
4 Setting the unlock mode 0:opened/1:closed 0:opened
5 Setting the unlock time 01 to 99 seconds 1 seconds
6Setting the nameplate
illumination mode On/Off/Auto On
7Setting night view LED
illumination mode On/Off/Auto Auto
8 Setting ring-back tone
Ringing one time
Ring continuously
No ring-back tone
Ringing one time
9 Setting image display mode
Alternate switching mode
Zoom mode
Full screen mode
Alternate switching mode

-10-
Setting Door Station Address
Total 4 addresses can be configured. It can be modified either before or after installatio
0 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
Setting Door Station Calling Mode
A
Call buttonA: Call all monitors in group address from
00~15.(one of the monitor should be set to 00)
Group calling mode
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep+
Press KEY_1 button to
activate Standard calling
mode for door station.
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to activate Group calling
mode for door station.
Press KEY_1
To update this setting, please follow the steps:

-11-
Setting Unlock Mode
There are 2 unlock modes, Normally opened and Normally closed.
Normally opened is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
Setting Unlock Time
By default, the unlock time is 1s, but it can be changed,the setting range is 1s~99s.
Follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time.
• When entering time delayed setting, the buzzer sound one time every second.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.
• If setting mode has not been exited, you can change the address of door station by pressing KEY1~4
freely.
• The LED_NAME indicator will always blink until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button four times to exit out the setting mode manually.

-12-
Setting Nameplate Illumination Mode
There are 3 illumination modes for nameplate indicator, Normally on,Normally off and Auto.
Normally on is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally on.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_3 button again
and again to set the nameplate
illumination mode to Auto.
Press KEY_3
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.
Setting Night View LED Illumination Mode
There are 3 working modes for night view LED indicator, Normally on,Normally off and Auto.
Auto is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_4 button to set
the night view LED mode
to Normally on.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_4 button again
to set the night view LED
mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_4 button again
and again to set the night
view LED mode to Auto.
Press KEY_4
• If setting mode has not been exited, you can change the night view LED illumination mode by pressing
KEY4 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.

-13-
Setting Ring-back Tone
If allow ring-back tone, press the call button to call monitor, a ring-back call tone can be heard
from door station.
There are 3 ring-back call tones, Ringing one time,Ringing continuously and No ring-back
tone.
Ringing one time is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep+
Press KEY_1 button to set
the ring-back call tone ringing
one time.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to set the ring-back call tone
ringing continuously.
UNLOCK Indicator:ON
TALK Indicator:ON
Buzzer Beep, Beep,Beep
Press KEY_1 button again
and again to close ring-back
call tone.
Press KEY_1
• If setting mode has not been exited, you can change the ring-back tone by pressing KEY1 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button once to exit out the setting mode manually.

-13-
-14-
Each indoor monitor should be assigned with an address in the system.
SVT-2 Outdoor Station B (2W12120): A maximum of 16 indoor monitors can be connected to the
system. Program the indoor monitors with user codes 0 - 15.
Input No. User Code Input No. User Code Input No. User Code
8200 Code=0 8211 Code=11 8222 Code=22
8201 Code=1 8212 Code=12 8223 Code=23
8202 Code=2 8213 Code=13 8224 Code=24
8203 Code=3 8214 Code=14 8225 Code=25
8204 Code=4 8215 Code=15 8226 Code=26
8205 Code=5 8216 Code=16 8227 Code=27
8206 Code=6 8217 Code=17 8228 Code=28
8207 Code=7 8218 Code=18 8229 Code=29
8208 Code=8 8219 Code=19 8230 Code=30
8209 Code=9 8220 Code=20 8231 Code=31
8210 Code=10 8221 Code=21
*For additional settings, refer to the Indoor Monitor User Manual.
6.2 DIP Switches Settings of Indoor Monitor
There are 3 DIP switches in total. Bits 1 and 2 are reserved and must be on the default position.
The Bit 3 is used to configure the position of each indoor monitor in the connection line. It must be set
to ON if the indoor monitor is in the end of the line, parallel connection, or connected to a SVT-2
DBC-4 module. It must be set to OFF if the indoor monitor is in the middle of the line (daisy chain
connection)
1 2 3
ON
Bit
DIP1&2 Reserved. left to default.
Set to OFF. When the monitor is in the middle of the line in daisy chain connection.
Bit State Description
DIP3
1 2 3
ON
1 2 3
ON
Set to ON. When the montior is at the end of the line or connected to a SVT-DBC4.

-15-
6.3 Power Supply
Name Description Specifications
SVT-2 PC6
SVT-PS5
It provides power for the outdoor stations,
indoor monitors and other accessories. It
supports a maximum of 16 indoor monitors. It
must be used along with a SVT-DPS device.
It supplies power for the outdoor stations,
indoor monitors and other accessories. It
supports up to 8 indoor monitors.
Input Voltage: 100 ~ 240Vac
Input Frequency: 50 ~ 60Hz
Rated Output Voltage: DC 28V, 2V
Rated Output Current: 1.5A
Input Voltage: 100~120VAC (2.5A),
200 ~ 240VAC (1.5A)
Input Frequency: 50 ~ 60 Hz
Rated Output Voltage: 24Vdc
Rated Output Current: 4.5A

-16-
7.Cable Requirements
Using different cables may affect the maximum distance which the system can reach.
When Monitor quantity ≤ 2
Cable Usage A B
CAT5 cable (1 pair of wire per
conductor - must solder the ends)
200 feet
60 meters
14 AWG Speaker Wire
(Stranded non-shielded)
When Monitor quantity ≤ 16
328 feet
100 meters
260 feet
80 meters
393 feet
120 meters
A
B
SVT-2 PC6
Cable Usage A B
CAT5 cable (1 pair of wire per
conductor - must solder the ends)
200 feet
60 meters
14 AWG Speaker Wire
(Stranded non-shielded)
131 feet
40 meters
260 feet
80 meters
196 feet
60 meters

-17-

The design and specifications of this user manual can be changed without any notification to the user.
All copyright and interpretation rights are reserved to SVT Innovations Inc.
This manual suits for next models
2
Table of contents
Other SVT innovations Intercom System manuals

SVT innovations
SVT innovations SVT-IP A User manual

SVT innovations
SVT innovations SVT-4 Outdoor Station C User manual

SVT innovations
SVT innovations SVT-2 User manual

SVT innovations
SVT innovations SVT-SMART 500 User manual

SVT innovations
SVT innovations SVT-MF2 User manual

SVT innovations
SVT innovations SVT-MF4 User manual

SVT innovations
SVT innovations SVT-2 User manual