EOS SteamRock II Premium User manual

Druck-Nr.: 2902 5195
Stand: 06/22
EN
Made in Germany
EOS SteamRock II Premium
EOS SteamRock II Premium NC
Steam Generator for Steam Rooms
Installation Instructions for Retailers

EN-2 Installation Instructions - EOS SteamRock II Premium
Documentation
EN
Documentation
Manufacturer
Original installation instructions EN
Copyright for these installation instructions remains with
EOS Saunatechnik GmbH.
Copyright as per DIN ISO 16016:
The copying and distribution of this document, as well as the use and com-
munication of its contents without express authorisation, are not permit-
ted. Compensation will be claimed in the event of infringements.
All rights reserved with regard to patent claims or submission of design or
utility patent.
Characters, symbols and illustrations
Revision history
EOS Saunatechnik GmbH
Schneiderstriesch 1
35759 Driedorf, Germany
Tel. +49 2775 82-514
Fax +49 2775 82-431
Email servicecent[email protected]
Web www.eos-sauna.com
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step
Table title
Title of figure
Date Version Description
19 Jan. 2022 02.20 Temperature limit, PFC in case of malfunction, cover sheet: UKCA indicator
7 Jan. 2022 02.10 Correction of the jumper settings.
1 Sept. 2021 02.00 Technical modifications to the steam generator, chapter on service completely
revised.
1 Dec. 2020 01.20 Chapters Safety, Standards and regulations, and Potential-free contact updated
1 Apr. 2020 01.00 First version of SteamRock II Premium

EOS SteamRock II Premium - Installation Instructions EN-3
Contents
Documentation..................................................................................................EN-2
1 General safety instructions..........................................................................EN-6
1.1 Safety levels................................................................................................EN-6
1.2 Mounting and electrical installation .................................................EN-7
1.3 Operator instruction ...............................................................................EN-9
2 Identification.................................................................................................... EN-11
2.1 Information about the units.............................................................. EN-11
2.1.1 EOS SteamRock II Premium/
SteamRock II Premium NC................................................. EN-11
2.1.2 EmoTouch 3 control panel ................................................ EN-13
2.2 Intended use........................................................................................... EN-14
2.3 Models....................................................................................................... EN-15
2.4 Cabin volume for each output capacity........................................ EN-15
2.5 Water hardness ...................................................................................... EN-17
3 Description of the units .............................................................................. EN-18
3.1 EOS SteamRock II Premium............................................................... EN-18
3.1.1 Scope of delivery................................................................... EN-20
3.1.2 System overview without housing cover..................... EN-22
3.1.3 System overview with circuit board............................... EN-23
3.1.4 Connections on the base of the housing..................... EN-24
3.1.5 Connections on the vaporiser cover.............................. EN-25
3.1.6 Vaporiser opened.................................................................. EN-26
3.2 EmoTouch 3 ............................................................................................ EN-27
3.2.1 Control panel with housing .............................................. EN-27
3.2.2 Control panel circuit board ............................................... EN-28
3.3 Technical data ........................................................................................ EN-28
3.3.1 EOS SteamRock II Premium /
SteamRock II Premium NC................................................. EN-29
3.3.2 EmoTouch 3 ............................................................................ EN-30
3.3.3 Standards and regulations ................................................ EN-30
4 Installation ........................................................................................................ EN-31
4.1 Steam generator.................................................................................... EN-32
4.1.1 Requirements ........................................................................ EN-32
4.1.2 Mounting the steam generator ....................................... EN-33
4.2 Water and steam pipes ....................................................................... EN-37
4.2.1 Requirements......................................................................... EN-37
4.2.2 Connecting the water supply and drain outlet.......... EN-39
4.2.3 Mounting the steam pipe .................................................. EN-40

EN-4 Installation Instructions - EOS SteamRock II Premium
EN
4.3 Installation work inside the cabin ...................................................EN-44
4.3.1 Inserting the steam pipe into the cabin and
installing the steam outlet.................................................EN-45
4.3.2 Specifications for connecting cables .............................EN-46
4.3.3 Installing the temperature sensor...................................EN-46
4.3.4 Cabin lighting.........................................................................EN-48
4.3.5 Fan .............................................................................................. EN-49
4.3.6 Potential-free contact..........................................................EN-49
4.4 EmoTouch 3.............................................................................................EN-50
4.4.1 Requirements .........................................................................EN-51
4.4.2 Mounting the control panel..............................................EN-52
4.5 Electrical installation ............................................................................EN-58
4.5.1 Main circuit diagram 9 kW .................................................EN-58
4.5.2 Main circuit diagram 18 kW...............................................EN-59
4.5.3 Main circuit board assignments.......................................EN-60
4.5.4 Add-on board for water level control............................EN-61
4.5.5 Mains connection..................................................................EN-62
4.5.6 Adjusting the output ...........................................................EN-63
4.6 Energy-supplied and switched consumers .................................EN-64
4.6.1 Connecting a consumer......................................................EN-65
4.7 Data lines..................................................................................................EN-68
4.7.1 Connecting data lines..........................................................EN-68
4.7.2 Level sensor for essence (optional accessory)............EN-71
4.8 Closing the housing .............................................................................EN-72
5 Commissioning ...............................................................................................EN-74
5.1 Steam generator....................................................................................EN-74
5.2 EmoTouch 3 – program settings .....................................................EN-74
5.2.1 User interface icons ..............................................................EN-75
5.2.2 Switching on and off............................................................EN-76
5.2.3 Setup during commissioning or after a reset ............EN-77
5.2.4 Defining the light source manually................................EN-79

EOS SteamRock II Premium - Installation Instructions EN-5
6 Installing multiple cabins ......................................................................... EN-82
6.1 Configuration options......................................................................... EN-83
6.1.1 Configuring 1–8 steam rooms.......................................... EN-84
6.1.2 Configuration 2 – 1 steam room and 4 sauna
cabins ........................................................................................ EN-85
6.1.3 Configuring 3–2 steam rooms.......................................... EN-86
6.1.4 Configuring 4–2 steam rooms.......................................... EN-87
6.2 Control lines and cabin addresses .................................................. EN-88
6.3 Programming of the cabin address................................................ EN-90
6.4 Setting up a multi-cabin installation.............................................. EN-90
7 Cleaning and servicing................................................................................ EN-94
7.1 Regular maintenance........................................................................... EN-94
7.2 Servicing the vaporiser tank.............................................................. EN-95
7.3 Replacing the heating coils .............................................................EN-106
7.4 Resetting the safety temperature limiter ...................................EN-108
7.5 Troubleshooting..................................................................................EN-110
8 General terms and conditions of service .........................................EN-112
9 Disposal ............................................................................................................EN-115

1
EN-6 Installation Instructions - EOS SteamRock II Premium
General safety instructions
EN
General safety instructions
1.1 Mounting and electrical installation
CAUTION
Observe the various qualifications required for performing
installation, repair, and service work.
Qualified personnel
Cleaning and service work must be performed only by persons
with the following qualifications:
Qualified personnel: Persons who have been instructed by the distribu-
tor on how to perform service work.
Trained personnel: employees extensively trained by the distributor.
Authorised personnel: Persons with regulatory approval for a specific
field of work, e.g. electrical installations.
These installation instructions are intended for authorised person-
nel familiar with the laws and regulations applicable to electrical
installations at the installation site. Observe the following general
safety instructions during assembly, setup and commissioning.
Risk to life and limb
and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follo-
wing completion of the installation work.
The electrical installation of the steam generator and other
electrical systems or equipment with a fixed mains connection
must only be performed by a trained electrician from an au-
thorised electrical company.
Ensure compliance with the applicable standards and regula-
tions for electrical installation.
The system must be disconnected and removed entirely from
the mains supply before commencing installation and repair
work.
The housing cover must only be removed by a trained specia-
list.

EOS SteamRock II Premium - Installation Instructions EN-7
General safety instructions
Fire hazard from
overheating
Insufficient ventilation can lead to device overheating and fire.
Flammable parts must not exceed a temperature of 140°C when
the unit is operated as intended or in the event of a malfunction.
Do not install the steam generator and control panel in enclo-
sed cabinets or wood panelling.
Touchable glass surfaces on the outside of the cabins could re-
ach a maximum of 76°C. Attach safety systems if needed.
Observe the cabin manufacturer's safety and installation inst-
ructions.
Risk of burns Touching hot pipelines can result in skin burns.
Insulate hot device parts.
Insulate hot pipelines; they must not remain exposed.
Risk of poisoning
from steam
Descaler can react with other chemicals, which can create poiso-
nous steam.
Place the container for descaler only under the steam generator
and secure it so it does not tip.
Ensure that the container with descaler cannot be mistaken for
the container with essence.
When refilling a container, ensure that descaler is not poured
into the container for essence.
Never place containers with descaler close to other chemicals.
Never place other chemicals close to the container of descaler.
Risk of scalding Contact made with hot steam or hot water can result in scalding of
the skin.
The steam pipe must always have an unobstructed exit outlet in
the cabin so that excess pressure does not build up in the
vaporiser tank.
The hose for excess pressure and the drain outlet for emptying
the vaporiser tank must be routed in such a way that there is no
risk of scalding if hot water escapes unintentionally.
When commissioning, take measurements to ensure that the
set output does not heat the cabin to over 50°C.
Risk of chemical
burns
Descaler consists of an acidic solution, which can burn eyes and
skin.
Wear eye and skin protection when connecting the descaler
line and refilling descaler.
Clean contaminated clothing thoroughly.

EN-8 Installation Instructions - EOS SteamRock II Premium
General safety instructions
EN
Damage to the unit
due to high levels of
lime
Lime deposits clog the vaporiser tank, slowing down the transfer
of heat to the water. This can lead to malfunctions because of over-
heating and blockages in the drain. A water softening system does
not replace regular descaling.
Non-compliance with these guidelines resulting in damage to the
unit renders the warranty void.
Check the hardness of the water before installing the unit.
In locations where the water is high in calcium carbonate (abo-
ve 5° dH), a water softening system is recommended.
If the level on the hardness scale is 11° dH or above, connecting
a water softening system to the steam generator is recommen-
ded.
A water softening system is required if the steam generator is
used commercially.
Damage to the unit Corrosive or heavy saline atmospheres damage the contacts in the
control panel, in the relay box and in the sensors.
The control panel and sensors should not be installed in a cor-
rosive or heavy saline atmosphere.
1.2 Operator instruction
The technician and/or distributor must instruct the operator of the
steam generator in the general safety instructions when commis-
sioning the unit. The operating instructions must be given to the
operator.
Risk of electric shock A risk to life and limb from electric shock and fire arises in the event
of improper repair work. This risk also applies after work is comple-
ted.
The housing cover must only be removed by a trained specia-
list.
Repairs and installations must only be performed by a trained
specialist.
The system must be disconnected and removed entirely from
the mains supply before commencing repair work.
Use only original spare parts from the manufacturer.

EOS SteamRock II Premium - Installation Instructions EN-9
General safety instructions
Risk of burns and
chemical burns
Touching hot parts may lead to skin burns and chemical burns of
the skin.
The operator must be familiar with the unit's hot parts and be
able to identify them.
The operator must be familiar with the settings for the heat out-
put and/or steam supply and understand how it is controlled.
Health risks Spending time in a steam room can lead to serious health risks or
even death for persons with health impairments.
These persons must consult with a doctor before visiting a
steam room.
Equipment damage
due to overuse
The uninterrupted operation time of the sauna cabin(s) can lead to
property damage.
In a commercial steam room, the steam generator must be set
so that it turns itself off after a specific period of time.
If the steam generator does not shut itself off, usage must be su-
pervised at all times.
Inspect the cabin before each use.
Operation by
children or persons
with reduced mental
capacity
This unit should not be used by children or persons with reduced
mental capacity or limited physical or sensory abilities.
Children must be supervised to ensure they do not play with
the unit.
Operation of a sauna cabin and/or steam room must not be
started by persons with reduced mental capacity or limited
physical or sensory abilities unless they are supervised.
Children and persons who have not received proper instruction
must not clean or service the system.

EN-10 Installation Instructions - EOS SteamRock II Premium
General safety instructions
EN
1.3 Safety levels
Safety instructions and important operating instructions are classified.
Please familiarise yourself with the following terms and symbols:
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in
damage to the unit.
1.4 Standards and regulations
For an overview of the standards that were observed during design and
construction of the sauna heaters, please refer to the individual product's
technical data sheet that can be downloaded from www.eos-sauna.com.
Local regulations also apply to the installation and operation of heating,
sauna, and steam room systems.

2
EOS SteamRock II Premium - Installation Instructions EN-11
Identification
Identification
The SteamRock II Premium steam generator is available in the following
models:
EOS SteamRock II Premium:
Steam generator incl. EmoTouch 3 control panel.
SteamRock II Premium NC:
same as EOS SteamRock II Premium but without control panel.
This document always refers to both models wherever SteamRock is menti-
oned.
2.1 Information about the units
2.1.1 EOS SteamRock II Premium/SteamRock II Premium NC
Nameplate
The nameplate is attached to the underside of the base of the housing.
Steam generator nameplate (example)
A Name
B Model
C Item number
D Operating voltage (depending on
the model)
E Operating pressure in pascals (bar)
F Country of origin
G Manufacturer
H Manufacturing date
I Serial number
Dampfgenerator
Type EOS SteamRock II Premium (Generator)
Art.-Nr. 94 7664 00
400 V 3N AC 12-18 kW
0 Pa (0 bar)
Made in Germany
EOS-SAUNATECHNIK GmbH, 35759 Driedorf
S-No. 30.21 00001
A
B
C
D
E
F
G
H I

EN-12 Installation Instructions - EOS SteamRock II Premium
Identification
EN
Warnings on the steam generator
The following warnings have been affixed to the steam generator (in Ger-
man, English and Russian).
Warnings on the base plate
A
B
B
A
29345103 / 49.19
VORSICHT | CAUTION | Осторожно !
!
Gefahr der Beschädigung!
Beim Auslösen des Sicherheitstemperaturbegrenzers, 30 min. Abkühlzeit gemäß Gebrauchsanweisung einhalten!
Reset/Betätigung des Sicherheitstemperaturbegrenzers nur durch autorisiertes Fachpersonal !
Risk of damage!
By released thermal fuse limiter observe 30 min. cooling time according to the operating manual!
Reset of the thermal fuse limiter only by qualified authorized personnel!
Риск Повреждения!
В случае сраб. защиты от перегрева соблюсти паузу 30 мин. для охлаждения по инструкции.
Возврат предохранителя от перегрева в исходное положение только специалистом!
29344893 / 27.17
VORSICHT
Осторожно
CAUTION
Verbrennungsgefahr!
Heiße Oberächen.
Nicht berühren.
Риск ожога!
Горячие поверхности.
Избегать прикосновения.
Burn Hazard!
Hot surfaces.
Do not touch.
!

EOS SteamRock II Premium - Installation Instructions EN-13
Identification
2.1.2 EmoTouch 3 control panel
Software version R. 2.18 or higher must be installed in the EmoTouch 3
control panel. The software release can be checked in the control panel; for
more information, see the operating instructions.
The nameplate is attached to the back of the housing.
Nameplate for control panel for SteamRock Premium (example: 12–18 kW)
Requirements for operation
The control panel must be installed outside of the steam room only.
The mounting location must meet the following climate condition require-
ments:
Ambient temperature during operation 5°C to 40°C
Air humidity during operation 30% to 75% rel. air humidity
Storage temperature: 0°C to 60°C
A Name
B Model
C Item number
D Operating voltage (depending on
the model)
E Country of origin
F Manufacturer
G Manufacturing date
H Serial number
Dampfgenerator
Type EOS SteamRock Premium (Bedienteil)
Art.-Nr. 94 7664 00
400 V 3N AC 12-18 kW
0 Pa (0 bar)
Made in Germany
EOS-SAUNATECHNIK GmbH, 35759 Driedorf
S-No. 30.21 00001
A
B
C
D
E
F
G H

EN-14 Installation Instructions - EOS SteamRock II Premium
Identification
EN
2.2 Intended use
EOS SteamRock II Premium and SteamRock II Premium NC
The SteamRock II Premium and SteamRock II Premium NC steam genera-
tors are designed to produce steam for a steam room. They must only be
mounted on a wall.
The SteamRock II Premium is suitable for use with private or commercial
steam rooms.
Incorrect sizing of the steam generator output is considered improper
use.
The SteamRock II Premium is operated via the EmoTouch 3 control
panel, which is included in the scope of delivery.
The SteamRock II Premium NC is used in a multi-cabin installation and
controlled by the existing control unit.
EmoTouch 3 control panel
The EmoTouch 3 control panel is suitable for private and commercial use to
control steam rooms, infrared cabins and sauna cabins. It must be moun-
ted on a wall.
The EmoTouch 3 control panel can control up to 8 steam generators
and/or sauna cabins.
One relay box per sauna cabin is required for a multi-cabin installation
with sauna cabins.
Foreseeable misuse
The following are considered instances of foreseeable misuse:
The output of the steam generator cannot accommodate the cabin
volume. See 2.4 Cabin volume for each output capacity, EN-15.
The control and sensor cable plugs are plugged in incorrectly.
The cabin addresses are programmed incorrectly.
The unit is operated without knowledge of or compliance with the saf-
ety instructions.
Operating, service and maintenance requirements are not observed.
The unit is operated after technical or other modifications are made to
the steam generator.
The unit is operated by children or persons with reduced mental capa-
city or by persons who have not been thoroughly instructed in its use.
General safety instructions, EN-6

EOS SteamRock II Premium - Installation Instructions EN-15
Identification
2.3 Models
Depending on the size of the steam room, it is possible to install multiple
steam generators for one room. A single EmoTouch 3 control panel is
installed for controlling the steam generators. Up to 8 steam generators
and/or sauna cabins can be controlled by the control panel.
2.4 Cabin volume for each output capacity
The output capacity of the unit must be calculated for each installation
individually and account for the size of the cabin and the design.
The output capacity is calculated using the following formula:
Room volume [m³] x K1 x K2 = output capacity [kW]
The following applies:
Incorrectly calculating the output capacity can lead to malfunctions and
unit damage. This is not considered proper use.
Cabins of lightweight construction, e.g. acrylic elements
Model Output Steam production Fuse Weight
Type 1 3.0 kW 6 kg/h 3 x 16 A 28 kg
6.0 kW 8 kg/h
9.0 kW 12 kg/h
Type 2 9.0 kW 12 kg/h 3 x 35 A 30 kg
12.0 kW 16 kg/h
15.0 kW 20 kg/h
18.0 kW 24 kg/h
K1 0.75 Ventilated room
0.52 Unventilated room
K2 1.00 Cabins of lightweight construction, e.g. acrylic elements
1.25 Wall made of tiled rigid foam elements
1.50 Wall covering comprised of tiles on wall/concrete or similar
2.00 Solid wall made of concrete or similar with tiles, natural stone, in
particular load-bearing exterior walls that draw significant energy
Output Ventilated room (sqm) Unventilated room (sqm)
3 kW 4 6
6 kW 8 12
9 kW 12 17
12 kW 16 23
15 kW 20 29
18 kW 24 35

EN-16 Installation Instructions - EOS SteamRock II Premium
Identification
EN
Cabin wall made of tiled rigid foam elements
Wall covering comprised of tiles on wall/concrete or similar
Solid wall made of concrete or similar with tiles or natural stone
Output Ventilated room (sqm) Unventilated room (sqm)
3 kW 3 5
6 kW 6 9
9 kW 10 14
12 kW 13 18
15 kW 16 23
18 kW 19 28
Output Ventilated room (sqm) Unventilated room (sqm)
3 kW 3 4
6 kW 5 8
9 kW 8 12
12 kW 11 15
15 kW 13 19
18 kW 16 23
Output Ventilated room (sqm) Unventilated room (sqm)
3 kW 2 3
6 kW 4 6
9 kW 6 9
12 kW 8 12
15 kW 10 14
18 kW 12 17

EOS SteamRock II Premium - Installation Instructions EN-17
Identification
2.5 Water hardness
NOTICE
Damage to the unit
Lime deposits clog the vaporiser tank, slowing down the transfer
of heat to the water. This can lead to malfunctions because of over-
heating and blockages in the drain. An upstream water softening
system does not replace regular descaling and regular maintenan-
ce.
Non-compliance with these guidelines resulting in damage to the
unit renders the warranty void.
Check the hardness of the water before installing the unit.
In locations where the water is high in calcium carbonate (abo-
ve 5° dH), a water softening system is recommended.
If the level on the hardness scale is 11° dH or above, connecting
a water softening system to the steam generator is recommen-
ded.
A water softening system is required if the steam generator is
used commercially.
Water softening guidelines
Conversion table for units of water hardness
Water hardness Water softening system
1–5° dH No
6–10° dH Recommended
11–15° dH Required
16–20° dH Mandatory
> 20° dH Mandatory
°dH °e °f ppm mMol/L
German degree 1° dH = 1 1.2522 1.7848 17.848 0.17832
British degree 1 °e = 0.79862 1 1.4254 14.254 0.14241
French degree 1 °f = 0.56029 0.70157 1 10 0.1
Russian degree 1 °rH = 0.140 0.176 0.251 0.146 0.025
CaCO3(USA) 1 ppm = 0.056 0.07 0.1 1 0.01
mMol/L 1 mMol/L = 5.6077 7.0218 10.009 100.09 1

3
EN-18 Installation Instructions - EOS SteamRock II Premium
Description of the units
EN
Description of the units
3.1 EOS SteamRock II Premium
The SteamRock II Premium is available with an output power range of 3 to
18 kW. This output capacity can operate steam rooms with a size of 3 m3to
18 m3.
The vaporiser tank is surrounded by a housing. The back side of the
housing is made of sturdy aluminium. A housing cover made of plastic
completely covers the steam generator and the electronics.
Depending on the design, 3 or 6 heating coils of 3 kW each are mounted
on the cover of the vaporiser tank.
The installed descaling system detects and reports when descaling is
required. It starts working automatically once descaling begins.
The unit is equipped with an integrated essence dosing system with two
separate dosing pumps. Two separate pipes allow for 2 different essences
to be supplied directly into the steam pipe.
Vaporiser tank
The heating coils heat the water in the vaporiser tank and create steam.
The steam is released into the steam room without pressure. Excess pres-
sure builds up only if the steam pipe is blocked by condensation or objects
in the cabin.
Water supply line
The water supply is fed through a connection at the base of the housing
and separates into two lines above the base plate: one for supply and one
for rinsing.
The supply line automatically refills the water once the water level in
the vaporiser tank falls below a certain level. A rod electrode sends 2
signals to a double magnetic valve that opens the inlet. It then closes
the inlet once the required water level has been reached.
The rinsing line is automatically opened after descaling and closed
again after rinsing has been completed.
Excess pressure
The sealed relief valve has a factory setting of 0.8 bar. Any excess pressure
can escape through a drain pipe. This pipe must be connected to a drain.

EOS SteamRock II Premium - Installation Instructions EN-19
Description of the units
Descaling
The descaling pump draws the descaler from the descaler container
through a hose. The hose is fed from the descaling pump, makes a loop
through the housing floor back into the housing and along the vaporiser
tank upward. The hose is attached to a stainless-steel connector on the
cover of the vaporiser tank.
To descale the tank, the tank is filled with water and descaler is pumped
into the tank. Once the descaler has had a chance to interact, the water
with the descaler is drained again. Fresh water is sprayed into the tank
through the rinse line to mechanically break up and rinse out lime scale
residue in the drain.
A level sensor indicates if the descaler container is empty.
NOTICE
Damage to the unit due to improper descaling
The heating coils could be damaged if the steam generator is not
descaled on a regular basis. An upstream water softening system
does not replace regular descaling and regular maintenance.
Damages to the unit due to improper descaling are not covered by
the warranty.
Use descaler suitable for water kettles and observe the manu-
facturer's dosage instructions. EOS Saunatechnik recommends
its own descaler, EOS SteamClean.
Descale the steam generator regularly.
Essence dosing (optional accessory)
Essence is drawn from the essence container by one of the essence pumps
into the corresponding hose and through the housing floor outward to the
injection nozzle in the steam pipe. The injection nozzle is mounted in the
steam pipe as close to the cabin as possible. Dosing is controlled by set-
tings made on the control panel.
Two separate lines allow for two different essences to be supplied. A level
sensor indicates if one essence container is empty. The message does not
indicate which container is empty.
If an essence container from a different manufacturer is used, the level is
not checked. In this case, the connecting cable for the level sensor must be
jumpered on the circuit board.

EN-20 Installation Instructions - EOS SteamRock II Premium
Description of the units
EN
3.1.1 Scope of delivery
In addition to the EOS SteamRock II Premium steam generator, the scope of
delivery also includes the following:
EOS SteamRock II Premium scope of delivery
The following are also mounted on the steam generator:
1.5 m white hose for descaler
2 pieces 1.5 m red hose for essence
2 spare fuses for main circuit board (enclosed)
1 m white connecting cable for descaler level sensor
1 m red connecting cable for essence level sensor
A 5 L descaler container with level sensor
B 0.5 m connecting hose for 3/8"–3/4" water connection
C 2 piece 1 1/4" brass union on 35 mm for mounting the
steam pipe
D Installation and operating instructions
E EmoTouch 3 control panel with housing (contained
only in the scope of delivery for EOS SteamRock II Pre-
mium)
F Temperature sensor incl. 5 m connecting hose
G 2 brass injection nozzles for essence
H 5 m connecting hose from control panel to steam gene-
rator
I 2 removal tools for the EmoTouch 3 control panel (con-
tained only in the scope of delivery for EOS SteamRock II
Premium)
J Steam outlet, 1 1/4" external thread
K 1 m red cable with O-clamps for connecting two essen-
ce containers
L Four 5x40 screws with four F6 anchors for installing the
steam generator on the wall
E
A
B
C
D
F
G
H
KJ L
I
Other manuals for SteamRock II Premium
2
This manual suits for next models
1
Table of contents
Other EOS Iron manuals

EOS
EOS SteamTec Classic Planning guide

EOS
EOS SteamTec Premium Troubleshooting guide

EOS
EOS SteamTec II Basic User manual

EOS
EOS SteamRock Premium User manual

EOS
EOS SteamRock II Premium User manual

EOS
EOS SteamAttrac User manual

EOS
EOS SteamRock II Basic User manual

EOS
EOS SteamRock Basic User manual

EOS
EOS SteamRock II Premium User manual