4)Time Control
Control the load on/off time through setting real-time clock.
5) Intelligent Power Mode
When the battery voltage is lower than “Under Voltage Warning Recover Voltage (UVWR
adjustable)”, the intelligent power mode is enabled; at this time, the LED current
percentage will be automatically reduced in linear with the voltage drop of battery. When
the battery voltage is lower than “Under Voltage Warning Voltage (UVW adjustable)”, a
minimum LED current percentage (default 2%, adjustable) will be output. In addition, when
the battery voltage is higher than UVWR, the controller will exit the intelligent power mode.
NOTE:The load is ON when the controller power on 1seconds. After 1
seconds it will restore to set working mode.
NOTE:In the mode of Light ON/OFF and Light ON/Timer, the load is
turned on after 10Min. delay,the delay time can be set.
6. Setting Operation
7. Protection
When the battery is correct connecting, the
PV can be reversed.
The controller is not
damage
When the PV is not connecting, the battery
can be reversed.
The battery voltage reaches to the OVD
The battery voltage reaches to the LVD
Temperature sensor is higher than 65℃
Temperature sensor is less than 55℃
Libattery Low
Temperature★
Temperature sensor is less than the low
temperature value
Stop charging or
discharge
Temperature sensor is higher than the low
temperature value
Begin charging or
discharge
Load current ≥2.5 times rated current
One short circuit, the output is OFF 5s;
Two short circuit, the output is OFF 10s;
Three short circuit, the output is OFF 15s;
Four short circuit, the output is OFF 20s;
Five short circuit, the output is OFF 25s;
Six short circuit, the output is OFF
Output is OFF
Clear the fault:
Restart the controller
or wait for one
night-day cycle
(night time>3 hours).
Load Open
Circuit(Load over
voltage)
Max. load voltage≥68V
One open circuit, the output is OFF 5s;
Two open t circuit, the output is OFF 10s;
Three open circuit, the output is OFF 15s;
Four open circuit, the output is OFF 20s;
Five open circuit, the output is OFF 25s;
Six open circuit, the output is OFF 5s;
Seven open circuit, the output is OFF 5s
Output is OFF
(Cycle to perform)
★WARNING: If selecting a lithium battery, it must be set low temperature
value(LTV) according to the charging/ discharging temperature of lithium
battery; otherwise, the lithium battery will be damaged.
8. Troubleshooting
Charging LED
indicator off during
daytime when
sunshine falls on PV
modules properly
Confirm that PV and battery wire
connections are correct and tight
Min.9V can start up the
controller.
Measure battery voltage with
multi-meter. Min.9V can start up the
controller.
Battery LED
indicator green Fast
Flashing
①Disconnect the solar array and
measure the battery voltage whether
is too high; ②Change the controller;
③Change the battery
Battery LED
indicator red
When the battery voltage is restored
to or above setpoint (low voltage
reconnect voltage), the load work
Battery Status LED
indicator red
flashing
The controller will automatically stop
working. When the temperature is
below 50 ºC, the controller will resume
to work.
All the LED indicator
flashing(battery red
Check whether the battery voltage
match with the controller working
voltage. Please change to a suitable
battery or reset the working voltage
Powering on
normally, the load is
off
①The connecting
wires are error or
virtual connection
②Load mode is wrong
③The controller does
not match with the LED
light.
④Output short circuit
①Check the connecting cables
②Check the load mode and
parameter
③The voltage of LED light source is
not in the output voltage range of
controller
④Check the connecting cables and
LED light source
The dimming
function is invalid
The controller does not
match with the LED
light source. This
product is a step-up
current control, If input
voltage is lower than
the rated voltage, it is
not working.
①Replace the LED light
②Reduce system rated voltage grade
and replace the product model
For example 24V system change to
12V system, and replace the
corresponding controller.
①When the battery is over discharged, the battery indicator will be red and the load will be off
all the time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV). In
order to judge the system is normal or not, firstly measuring the battery voltage whether is
more than LVRV, if not, restarting the controller to detect the load whether it is normal.
WARNING: The LVRV can be set, but it must pay more attention that it
maybe damages the battery if the LVRV is too low.
9. Technical Specifications
◆The controller is not recognize system voltage and no temperature compensation
when the battery connect the lithium battery.
▼The parameters are 12V system at 25 ºC, please double the values in 24V system.
10. Disclaimer
This warranty does not apply under the following conditions:
Damage from improper use or use in an unsuitable environment.
PV or load current, voltage or power exceeding the rated value of controller.
The controller is working temperature exceed the limit working environment
temperature.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Any changes without prior notice! Version number:V1.8
Max. PV open circuit voltage
Battery input voltage range
(Max. Battery Voltage +2V)~60V
Load open circuit voltage
Maximum output efficiency
Output current
control accuracy
Lead-acid battery: Sealed(default)/Gel/Flooded/User
Lithium battery:LiFePO4/Li-NiCoMn/User
Sealed:14.6V; Flooded:14.8V;User:9-17V
Sealed:14.4V;Gel:14.2V;Flooded:14.6V;User:9-17V
Sealed/Gel/Flooded:13.8V;User:9-17V
Low Voltage
Reconnect Voltage▼
Sealed/Gel/Flooded:12.6V;User:9-17V
Under Voltage Warning
Recover Voltage▼
Sealed/Gel/Flooded:12.2V;User:9-17V
Under Voltage Warning
Voltage▼
Sealed/Gel/Flooded:12.0V;User:9-17V
Low Voltage Disconnect
Voltage▼
Sealed/Gel/Flooded:11.1V;User:9-17V
LiFePO4(4s):14.5V/Li-NiCoMn(3s):12.5V/User:9-17V
Low Voltage
Reconnect Voltage▼
LiFePO4(4s):12.8V/Li-NiCoMn(3s):10.5V/User:9-17V
Under Voltage Warning
Recover Voltage▼
LiFePO4(4s):12.8V/Li-NiCoMn(3s):12.2V/User:9-17V
Under Voltage Warning
Voltage▼
LiFePO4(4s):12.0V/Li-NiCoMn(3s):10.5V/User:9-17V
Low Voltage Disconnect
Voltage▼
LiFePO4(4s):11.1V/Li-NiCoMn(3s):9.3V/User:9-17V
Charge Circuit Voltage Drop
Working environment
temperature
PV/BAT:14AWG/2.5mm2
LOAD: 18AWG/1.0mm2
PV/BAT:12AWG/4.0mm2
LOAD:18AWG/1.0mm2
There are two methods that it can realize controller work
mode and parameters through IR function:
1) IR Remote Controller—RC-10
2) Super Parameter Programmer—FC-01
This method can realize one-key setting operation which is
suitable for bulk quantity products setting or applied in the
projects.
NOTE: Please refer to the user manual of handheld
device.